Mod: MDM/011/M4 Rev 1 IDS GeoRadar User Guide QGG/2020/002 Rev. 1.1 RockSpot User Guide September 2020 Mod: MDM/011/M4 Rev 2 IDS GeoRadar User Guide QGG/2020/002 Rev. 1.1 1 Important Information about your Instrument Read and follow the Quick Guide before using the pr oduct or the accessories delivered with the product. ☞ Keep for future reference! Intended use The intended use is the real time detection of fast -moving geological event, such as rockfall, debris flow, snow avalanche, etc. in one of the following possible environments: • open pit mines and quarries • natural landslides • glaciers • snowy slopes • tailing dams. The product must not be disposed with household was te. Mod: MDM/011/M4 Rev 2 IDS GeoRadar User Guide QGG/2020/002 Rev. 1.1 Conformity to European regulations This equipment is compliant with the essential requ irements and other relevant provisions of Directive 2014/53/UE. The full Declaration of its Conformity can be found either on the CD or a separate document included with this product. This is a Class A product. In a domestic environmen t it may cause radio interference. If so, the user may need to take adequate measures. Conformity to U.S regulations. FCC Use limits The RockSpot sensor is granted by FCC approved, acc ording to the Code of Federal Regulations, Title 47, Chapter I, Subchapter D, Par t 90, Subpart F, Private land mobile radio services; Radiolocation Service. In order to use th e sensor in the US territory, a license of utilization must be obtained by FCC. The license ap plication can be submitted to the following website: http://wireless.fcc.gov/uls/index.htm?job=home Electronic This product poses no health and safety risk when o perated in the normal manner of the intended use. FCC statements: . This device complies with FCC Part 15. Ope ration is subject to the following two conditions: (1) this device may not cause interfere nce, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. . This device complies with Health Canada's Safety Code. The installer of this device should ensure that RF radiation is not emitted in e xcess of the Health Canada's requirement. Mod: MDM/011/M4 Rev 2 IDS GeoRadar User Guide QGG/2020/002 Rev. 1.1 Information can be obtained at http://www.hc - sc.gc.ca/ewh - semt/pubs/radiation/radio_guide-lignes_direct-eng.p hp. . Changes or modifications not expressly app roved by the party responsible for compliance could void the user's authority to opera te the equipment. . . This product complies with FCC and ISED ra diation exposure limits set forth for an uncontrolled environment. The antenna should be ins talled and operated with minimum distance of 30 cm between the radiator and your bod y. Conformity to Canada regulations. The RockSpot sensor is granted by ISED as a license exempt low power device, according to RSS-210 Issue 10, Annex F, F.1. Operating band is 1 0.50-10.55 GHz, with a maximum EIRP of 32.7dBm. Within the above mentioned limitation in t erms of band and emitted power, ROCKSPOT can be used in Canada, without any license . For more information about licensing procedure cont act IDS GeoRadar personnel. ISED Statements: . Cet appareil est conforme à FCC Partie15. Son utilisation est soumise à Les deux conditions suivantes: (1) cet appareil ne peut pas provoquer d'interférences et (2) cet appareil doit accepter Toute interférence, y compri s les interférences qui peuvent causer un mauvais fonctionnement du dispositif. . Cet appareil est conforme avec Santé Canad a Code de sécurité 6. Le programme d'installation de cet appareil doit s'assurer que l es rayonnements RF n'est pas émis au-delà Mod: MDM/011/M4 Rev 2 IDS GeoRadar User Guide QGG/2020/002 Rev. 1.1 de I'exigence de Santé Canada. Les informations peu vent être obtenues: http://www.hc- sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes _direct-eng.php . Les changements ou modifications non expre ssément approuvés par la partie responsable de la conformité pourraient annuler l'a utorité de l'utilisateur à utiliser cet équipement. . This device contains license-exempt transm itter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada 's license-exempt RSS(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interferenc e, including interference that may cause undesired operation of the device. . L'émetteur/récepteur exempt de licence con tenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement éco nomique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: 1. L'appareil ne doit pas produire de brou illage; 2. L'appareil doit accepter tout brouillag e radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. . Cet appareil est conforme aux limites d'ex position aux rayonnements de l’ISED pour un environnement non contrôlé. L'antenne doit être ins tallé de façon à garder une distance minimale de 30 centimètres entre la source de rayon nements et votre corps. Mod: MDM/011/M4 Rev 2 IDS GeoRadar User Guide QGG/2020/002 Rev. 1.1 Canadian Representative: Company Name: Leica Geosystems Ltd Company Number: 3177B Company Address: 1-3761 Victoria Park Ave City: Scarborough Province/State: Ontario Postal Code: M1W 3S2 Country: Canada Contact Name: Sudha Sachdeva Phone Number: +1 416 497 2463 Email: [email protected] Mod: MDM/011/M4 Rev 2 IDS GeoRadar User Guide QGG/2020/002 Rev. 1.1 1.1 Symbols Warning messages are an essential part of the Safet y Concept of the instrument. They appear wherever h azards or hazardous situations can occur. WARNING Indicates an imminently hazardous situation which, if not avoided, will result in death or serious inj ury. DANGER Indicates a potentially hazardous situation or an u nintended use which, if not avoided, c…
Text truncated - open the document above for the full version.
IDS GeoRadar s.r.l. - Codice Fiscale 02216580502 – VAT n° IT 02216580502 - RAEE N° IT16060000009358 Legal office Via Carducci n. 32, 20123 Milano (MI) Italy Registered at the Milano Chamber of Commerce, R.E.A. 2115412 - Pec [email protected] Share capital Euro 20.000 fully paid A company with a sole shareholder, subject to the coordination and control of Hexagon Geosystems Services S.p.a. Cornegliano Laudense (LO) Via Codognino 10, 26854, Cod. Fiscale 09430450966 Nemko Canada Inc 303 River Road Ottawa, Ontario, Canada K1V 1H2 Attn: Director of Certification Authority to Act as Agent On our behalf, I appoint Nemko Canada Inc. to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in Industry Canada’s regulations will have affixed to it a lab identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko Canada Inc, still resides with IDS GeoRadar srl, via Augusto Righi 6, 6A, 8 56121 Pisa (Italy). Dated this 16 th Day of June 2020 Agency agreement expiration date: 15 th of June 2021 By: Guido Manacorda Title: Director R&D On behalf of : (Company Name) IDS GeoRadar srl Telephone: + 39 050 8934269 IDS GeoRadar Headquarters Via A. Righi, 6, 6A, 8 56121 Pisa (PI) Italy Tel. +39.050.8934.100 Fax +39.050.7912.130 [email protected] www.idsgeoradar.com
IDS GeoRadar s.r.l. - Codice Fiscale 02216580502 – VAT n° IT 02216580502 - RAEE N° IT16060000009358 Legal office Via Carducci n. 32, 20123 Milano (MI) Italy Registered at the Milano Chamber of Commerce, R.E.A. 2115412 - Pec [email protected] Share capital Euro 20.000 fully paid A company with a sole shareholder, subject to the coordination and control of Hexagon Geosystems Services S.p.a. Cornegliano Laudense (LO) Via Codognino 10, 26854, Cod. Fiscale 09430450966 REQUEST FOR CONFIDENTIALITY Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: UFW-ROCKSPOT Product Name: ROCKSPOT Pursuant to FCC 47 CRF 0.457(d) and 0.459, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term Permanent External Photos Short Term Permanent Internal Photos (*) Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Permanent Test Setup Photos Short Term Permanent User’s Manual (*) According to FCC guide “726920 D01 Confidentiality Request Procedures v01r02” (April 8, 2016), we wish that all contents shown in the “internal photos” exhibit are subject to this Long Term Confidentiality request. Note: these materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. The devices pictured in the document “ROCKSPOT-Internal photos.pdf” are sealed and potted unit that cannot be opened after manufacturing without destroying the contents. Specifically, in order to view inside the product to which this request refers, one would have to carry out the following steps: 1. Use a special key to remove the screws securing the cover. This special key is not available to the general public. Moreover, these screws have to be removed in a specific order not to cause irreparable damages. The information on the removal order is available to IDS GeoRadar and to authorized repair centers only. 2. Inside the unit, electromagnetic absorbers cannot be removed without damage and will have to be replaced with new ones when re-assembling. This material is custom built and not available to the public or to a competitor. 3. De-solder the transmitter and the receiver from the antenna flares to initiate access to certain electronics of the antenna. Then carefully disconnect and withdraw the assemblies from the shield /construct assembly. When these steps are done improperly the electronics can be severely damaged. IDS GeoRadar has never released instructions on how to disassemble its units and does not answer questions on how to do so. This information is kept internal to the company. If a unit arrives at the company's repair facility IDS GeoRadar Headquarters Via A. Righi, 6, 6A, 8 56121 Pisa (PI) Italy Tel. +39.050.8934.100 Fax +39.050.7912.130 [email protected] www.idsgeoradar.com IDS GeoRadar s.r.l. - Codice Fiscale 02216580502 – VAT n° IT 02216580502 - RAEE N° IT16060000009358 Legal office Via Carducci n. 32, 20123 Milano (MI) Italy Registered at the Milano Chamber of Commerce, R.E.A. 2115412 - Pec [email protected] Share capital Euro 20.000 fully paid A company with a sole shareholder, subject to the coordination and control of Hexagon Geosystems Services S.p.a. Cornegliano Laudense (LO) Via Codognino 10, 26854, Cod. Fiscale 09430450966 showing evidence of such tampering, the company does not repair it, but charges the customer for a new unit plus freight costs. The Commission's posting of the photographs as well as of the schematics and components list, would allow a competitor to bypass this difficult and expensive disassembly. From the photographs, a competitor can also estimate: 1. the costs of manufacturing the printed circuit boards and mechanical housing; 2. the man-hours required to assemble the device; 3. any compatibility problems the manufacturer will have in designing new systems; and 4. the age of the electronic design (which gives valuable competitive information on upgrade and R&D efforts). Access to interior photographs would almost permit a competitor to conduct a complete reverse engineering, to the point of producing a schematic. We are also reminding that the unit will not be made available for sale to the general public. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Dated this 16 th Day of June 2020 By: Guido Manacorda Title: Director R&D On behalf of : (Company Name) IDS GeoRadar srl Telephone: + 39 050 8934269
N. Doc: NDAU/20XX/XXX IDSGRD_Mod: MDM/128/M2 rev1 07/08/2020 Unilateral Confidentiality Agreement This Agreement is made and entered into as of ........... (the “Effective Date”). BETWEEN IDS GeoRadar S.r.l. whose registered office is at Via Carducci no. 32 –20123 Milan, Italy (hereinafter referred to as "IDS GRD"), of the one part; AND .................., whose registered office is at ...................../who is resident at ................., [please fill in as appropriate and delete the inappropriate part] (hereinafter referred to as "Partner"), of the other part. WHEREAS Partner is and will be involved in a project concerning ....................... (hereinafter referred to as the "Project") during which IDS GRD will disclose its own and possibly third parties' proprietary or confidential information to Partner and IDS GRD wishes to protect such proprietary or confidential information; NOW THEREFORE IT IS HEREBY AGREED as follows: 1. In this Agreement the term "Proprietary Information" or "Confidential Information" shall mean any and all technical (including computer code, inventions, algorithms, know-how and ideas), business, financial, commercial and/or other information (whether in visual or machine readable form) disclosed by IDS GRD, as well as Proprietary Information disclosed orally, which was brought to the attention of Partner in any manner whatsoever, PROVIDED, HOWEVER that Pro- prietary Information shall not include any information which the Partner can show: (i) is in or comes into the public domain otherwise than through a breach of this Agree- ment or the fault of Partner; or (ii) has been lawfully received by Partner from a third party without restriction as to its use or disclosure; or (iii) was already in the possession of Partner free of any such restriction prior to receipt from IDS GRD; or (iv) was independently developed by Partner without making use of the Proprietary In- formation; or (v) has been approved for release or use (in either case without restriction) by written authorization of IDS GRD. 2. Partner undertakes: 2.1 to keep such Proprietary Information confidential; 2.2 not to use such Proprietary Information otherwise than for the purposes of the Project unless such use is specifically authorized in writing by IDS GRD; 2.3 not to disclose such Proprietary Information to any employees or affiliates of Partner (in- cluding persons employed by parents, subsidiaries or other affiliates under direct or indirect, com- mon control) other than those having a need to know for the purposes of the Project, and then only on the understanding that such persons are made aware of and undertake to observe the provisions of this Agreement; – 2 – N. Doc: NDAU/20XX/XXX IDSGRD_Mod: MDM/128/M2 rev1 07/08/2020 2.4 not to disclose Proprietary Information to any third party except for the purposes of the Project and with the prior written consent of IDS GRD or legal advisors, and then only on the un- derstanding that such third party is made aware of and undertakes to observe the provisions of this Agreement; 2.5 not to copy or reduce Proprietary Information to writing except as may be strictly necessary for the purposes of the Project; and 2.6 to notify IDS GRD immediately if it becomes aware that the Proprietary Information has been disclosed to or is in the possession of any person who is not authorized by this Agreement to receive the Proprietary Information; and 2.7 to return to IDS GRD on demand all copies of Proprietary Information reduced to writing (or other permanent form) and to destroy all notes and any other written reports or documents which may have been made by Partner to the extent they contain any part of or reference to the Proprietary Information in whole or part except as authorized in writing by IDS GRD or as is strictly necessary to complete any outstanding obligations relating to the Project whereafter such Proprietary Infor- mation shall be returned or destroyed as aforesaid. 3. Notwithstanding the foregoing, Partner shall be entitled to disclose Proprietary Information to the extent required by law, regulation or legal process, provided that, to the extent practical, Partner gives prior notice to IDS GRD of the reasons for and the proposed contents of such disclo- sure. 4. In providing Proprietary Information, IDS GRD makes no representation, warranty, assur- ance, or inducement, express or implied, as to its adequacy, sufficiency or freedom from defect of any kind. IDS GRD shall not be liable for the use of the Proprietary Information by the Partner. 5. All intellectual property, whether registered or not, such as, but not limited to, patents, rights granted under patent licenses, know-how, trademarks and copyrights ("Intellectual Property") that may be associated with Proprietary Information that IDS GRD may disclose to Partner shall remain vested exclusively in IDS GRD at all times and nothing herein shall be construed, expressly or implied, as to transfer any of the Intellectual Property rights from IDS GRD to Partner. 6. Partner shall not assign its interest under this Agreement to another party without the prior written consent of IDS GRD. Any such assignment shall be void and of no effect. 7. Partner acknowledges that its obligations to protect all Confidential Information is essential to the business interests of IDS GRD and that the disclosure of such Confidential Information in breach of this Agreement would cause IDS GRD immediate, substantial and irreparable harm, the value of which would be very difficult to determine. Accordingly, the parties agree that, in addition to any other remedies that may be available in law, equity or otherwise for the disclosure or use of Confidential Information in breach or threatened breach of this Agreement, IDS GRD shall be en- titled to seek and obtain a temporary restraining order, injunctive relief or other equitable relief against the continuance of such breach or threatened breach of this Agreement, …
Text truncated - open the document above for the full version.
EXTERNAL PHOTOS
ROCKSPOT FCC ID: UFW-ROCKSPOT
IDS GeoRadar s.r.l. - Codice Fiscale 02216580502 – VAT n° IT 02216580502 - RAEE N° IT16060000009358 Legal office Via Carducci n. 32, 20123 Milano (MI) Italy Registered at the Milano Chamber of Commerce, R.E.A. 2115412 - Pec [email protected] Share capital Euro 20.000 fully paid A company with a sole shareholder, subject to the coordination and control of Hexagon Geosystems Services S.p.a. Cornegliano Laudense (LO) Via Codognino 10, 26854, Cod. Fiscale 09430450966 “ FCC ID: UFW-ROCKSPOT Product Name: ROCKSPOT TUNE UP INFORMATIONS ROCKSPOT is designed so that the switching range matches the alignment range. No tune up procedure is required by technicians or users after the equipment has left the factory to match its specifications on the working frequency. No manual trimmers or adjustments that can be manually done are implemented. Date: 16/06/2020 Company name IDS GeoRadar Srl Name and Surname Guido Manacorda Position/Function Director R&D Signature________________________ IDS GeoRadar Headquarters Via A. Righi, 6, 6A, 8 56121 Pisa (PI) Italy Tel. +39.050.8934.100 Fax +39.050.7912.130 [email protected] www.idsgeoradar.com
Manufacturer: IDS GeoRadar Srl Name: Oscar Frau Product: ROCKSPOT Title: Project Handler FCC ID: UFW-ROCKSPOT Signature: IC: 8991A-ROCKSPOT MPE limits for FCC, 1.1310 Mode Frequency Duty Cycle Power Antenna Gain EIRP 7 EIRP ERP EIRP 4 Distance D PD 8 PD Limit 9 Margin §90.103 (c)(13) EIRP Limit PD/PD Limit MHz % dBm dBi dBm mW dBm W cm mW/cm^2 mW/cm^2 dB W FMCW 1 10450 100 30,77 9,00 39,77 9484 37,62 1,19 30 0,8386 1,000 0,76 5 0,83859 1 Test Report n. 395212TRFWL; Power: p. 7; Gain: p. 7 4 EIRP at antenna port 7 EIRP = ( Power dBm + Antenna Gain dBi ) + 10 x Log ( Duty Cycle % / 100 ) 8 PD = EIRP / (4xπxD 2 ) 9 CFR 47 Part 1, §1.1310(e), table 1
Nemko Spa, 20853 Biassono (MB) - Italy. All rights reserved. T his publication may be reproduced in whole for non-commercial purposes as long as Nemko Spa is acknowledged as copyright owner and source of the material. Nemko Spa takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Nemko Spa accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. This test report may not be partially reproduced, except with the prior written permission of Nemko Spa. The test report merely corresponds to the test sample. The phase of sampling / collection of equipment under test is carried out by the customer. This Test Report, when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory, or by a laboratory having special agreement with Nemko. Report Reference ID: 395212TRFWL Test specification: Title 47-Telecommunication Chapter I - Federal Communications Commission Part 90 – Private Land Mobile Radio Services Subpart F – Radiolocation Service Applicant: IDS GeoRadar Srl – Via A. Righi, 1-2 – 56121 Pisa (PI) – Italy Apparatus: X-band Interferometric Doppler Radar Model: ROCKSPOT FCC ID: UFW-ROCKSPOT Testing laboratory: Nemko Spa Via del Carroccio, 4 – 20853 Biassono (MB) – Italy Name, function and signature Date Tested by: Tessa S. ( project handler) 2020-06-09 Reviewed by: P. Barbieri (verifier) 2020-06-09 Page 2 of 34 Report No. 395212TRFWL Table of contents Section 1: Report summary.......................................................................................................... 3 1.1 Test specification .................................................................................................................. 1.2 Statement of compliance ................................................................................................ 1.3 Exclusions ............................................................................................................................ 1.4 Registration number ............................................................................................................. 1.5 Test report revision history ................................................................................................ 1.6 Limits of responsibility ........................................................................................................... Section 2: Summary of test results ............................................................................................. 5 2.1 FCC Part 90, test results....................................................................................................... Section 3: Equipment under test (EUT) and application details ................................................ 6 3.1 Applicant details ................................................................................................................... 3.2 Modular equipment ............................................................................................................... 3.3 Product details ...................................................................................................................... 3.4 Application purpose .............................................................................................................. 3.5 Certification details ............................................................................................................... 3.6 Composite/related equipment ............................................................................................... 3.7 Sample information ............................................................................................................... 3.8 EUT technical specifications ................................................................................................ 3.9 Accessories and support equipment ..................................................................................... 3.10 Operation of the EUT during testing ...................................................................................... 3.11 EUT setup diagram ............................................................................................................... 3.12 Software version ................................................................................................................... Section 4: Engineering considerations ....................................................................................... 8 4.1 Modifications incorporated in the EUT .................................................................................. 4.2 Deviations from laboratory tests procedures ......................................................................... 4.3 Technical judgment ............................................................................................................... Section 5: Test conditions ........................................................................................................... 9 5.1 Deviations from laboratory tests procedures ......................................................................... 5.2 Test conditions, power source and ambient temperatures .................................................... 5.3 Measurement uncertainty ................................................................................................ 5.4 Test equipment ................................................................................................................... Section 6: Test results ................................................................................................................ 12 6.2 Clause 90.205 (r) and 90.103 (13) RF power output ........................................................... 6.2 Clause 90.103 (b) Occupied Bandwidth ........................................................…
Text truncated - open the document above for the full version.
Setup photos 395212TRFWL, 395212-1TRFWL Date of issue: June 9, 2020 Applicant: IDS GeoRadar Srl Via A. Righi 1-2 – 56121 Pisa – Italy Product name: ROCKSPOT Model: ROCKSPOT FCC ID: IC Registration number: UFW- ROCKSPOT 8991A- ROCKSPOT Report reference ID: 395212TRFWL, 395212-1TRFWL Page 2 of 3 Section 1. Radiated emission 1.1 Radiated emissions set-up for frequencies below 1 GHz Report reference ID: 395212TRFWL, 395212-1TRFWL Page 8 of 3 1.2 Radiated emissions set-up for frequencies above 1 GHz Report reference ID: 395212TRFWL, 395212-1TRFWL Page : of 3 Report reference ID: 395212TRFWL, 395212-1TRFWL Page ; of 3 Report reference ID: 395212TRFWL, 395212-1TRFWL Page 3 of 3 Section 2. Frequency stability
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 3 | 9 | 10.41 GHz - 10.49 GHz | 1.19 W | 83M7F1D | 28.8 ppm |

High Definition Ground Based SAR
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Ku-band radar sensor
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Cable locator transmitter
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Chaser XR GPR CHASERXR
Equipment Class
UWB - Ultra Wideband TransmitterGPR AM201
Equipment Class
UWB - Ultra Wideband Transmitter