FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Food Automation - Service Techniques, Inc./
  3. UJ7-XWIRE-GATEWAY

UJ7-XWIRE-GATEWAYFood quality and supply chain monitor equipment

Food Automation - Service Techniques, Inc.
Food quality and supply chain monitor equipment - FCC ID UJ7-XWIRE-GATEWAY - Food Automation - Service Techniques, Inc.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Nov 20, 2011
Application Purpose
Original Equipment
Date of Application
Nov 14, 2011
Equipment Note
Food quality and supply chain monitor equipment
Frequency Range
2405.00000000 - 2480.00000000
Company
Food Automation - Service Techniques, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

InstallationGuide Xwi re TM Univ ersalSmartAdapterfo r Communications-Enabled Appliances Xwi re TM SmartBezelAdapterfor Process Con tro ll ers Xwi re TM SmartGatewayPC Adapter SmartAdapter SmartBezel Sm artGateway 24/7Toll- FreeTechnical Su pport 1-866- 840-4271 (fro m the U.S.,Canadaand th e Ca ribbean) Direct, Inc. www.MySCK.com SAVEtheseinstructions forfuturereference. 2 ©2008SCKDirect,Inc.229-51316RevFwww.MySCK.com Xwire TM Direct, Inc. NOTICE S SC K Di rect,Inc . is not liablefo r any use of product not in accor - dancewithSCKDire ct , In c.’sin sta llationandope ration instructions . BEFOREUSINGTHISEQUIPME NT, OR FO R ANYQUE STIONSON THE OPERATI ON OF THE APP LIANCE,CONSULTANDFOLLOW ALL INSTRUCTI ONSANDSAFETY WARNINGSFOUNDIN TH E APP LI - ANCEOPERATOR’SMA NUALSUPPLIEDFROMTHE MANUFACTUREROF THE APPLIANCE. CL EAN IN G Us in g a cl ean dampcloth,wipedownthe pro duct s whennece s- sary usinga commercialqualityfoodservice-a pproveddet er gent . DO NOTIMMERSE. NEVERuse chemicalor abrasive cleanerson SCK pro duct s. TOOLSRE QUI RED FOR IN STA LLATION Flat sc rewdriver(for SmartBezel) Plie rs (for SmartBezel) Phillipsscrewdriver (for SmartAdapt er) Drill bit: 3/ 16” if usinganc hor . #50 if in st allingint o metal(f or SmartAdapter) Chang es or modificationsnot express ly approvedby SCK Direct,Inc. co uld voi d the manuf acturer’swarran ty and th e use r's authorityto op erate th e equipment. NOTE: Th is equipment ha s beentestedand fou nd to com ply with the limitsfo r a ClassB digitaldevice,pursuant to Part 15 of the FCC Rules.Th ese li mitsare designedto pr ovid e reas ona ble prot ection againstharmful interferencein a res identialinstallation.This equi pmentgenerates,uses and can radiatera dio frequency en er - gy and,if notinstall ed andusedin accordance wi th th e instructions,maycau se harmful int erferenceto rad io communica- tion s. However,thereis no guarantee th at int erference will not occ ur in a parti cul ar installation.If this equ ipmentdoes cause harmful interferenceto rad io or television reception, wh ich can be determined by turningthe equ ipmentoff an d on, the useris encouraged to try to corr ect the interferenceby one or moreof the followingmeasures: Reor ien t or relo catethe receiving antenna . Increase th e separationbe tween theequipmentand receiver. Connect the equi pmentintoan outleton a circuit diff erent fromth at to whichthe receiver is co nnected. Consultthe de aler for help. TABLE OF CONTENTS Installation:WirelessSmartGateway Ada pt er . . . . . . . . . . . . . .3 Installation:Sm artBezel Ada pter for FASTVC- 210 & FAS T EM-99Controller s . . . . . . . . .4 Installation:Universa l SmartAdapter for FASTTRACKERTimers . . . . . . . . . . . . . . . . . . . . . . . . . .5 Installation:Universa l SmartAdapter for Fry ers & Ovens. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Ligh t Bar and LED StatusCh arts . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Troubleshooti ng . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Changingthe De faultPANID . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 3 ©2008SCKDirect,Inc.229-51316RevFwww.MySCK.com installationguide XwireWir eles s SmartGatewayAdapter REQUIREDPARTS (A)XwireWir elessSmartGateway Ada pter SCK Part No. 231- 60207-01 (B)USB Cable,5M SCK Part No. 141- 15734 INSTALLATION 1.Con nectUSB cableto the communicat ion por t on the Sma rtG ateway. 2.Pow er off the PC an d connectthe SmartGat ewayto an available USB po rt usingthe USB cable. NOT E : It’s importantto powerdownfor properco nfiguratio n. 3.Verifythe LE D seq uen ce on the Sma rtG ateway is cor rect per you r appl ica - tion by referring to the chartson page6. STE P 1 The Sm ar tGateway shouldbe installed first . 4 ©2008SCKDirect,Inc.229-51316RevFwww.MySCK.com Xwire TM Direct, Inc. Xwi re SmartBezel Adapter for FAST VC-210& FAST EM- 99 CONTR OLLERS REQUIRE D PART S (1)XwireSmartBezelAdapter SCK Part No. 231- 60206-01 (2)Self-tappingConnecto rs (included ) SCK Part No. 141- 51026 Qty. 2 IN ST ALLATION 1.Locatewiresnumbered1 and 3 in the 9-pincon nectoron the FASTVC- 210 or FAS T EM-99controllers. 2.Clamp self-tappingconnector to th es e wiresto providea 24VAC ou tputfo r the SmartBezel. 3.Connect the two spa de ter minalsto the pa ir coming from the SmartBez el. 4.Connect the 3-pinMolexconnector on th e SmartBezelto the 3- pin Mo lex on the controller. 5.Positionthe SmartBezelontothe frontof the FASTController. Carefullyplacethe fiv e SmartBezel wiresin to the channelon the FASTController. 6.Installthe FASTCon trol ler on the fryerand verifythe LED sequence is correctper yourapplicationby referringto the cha rts on page6. The FAST Controlleris now ready to be used as an SCK Xwi re wir eless de vice. STEP 2 The SmartBezel Adapter 5 ©2008SCKDirect,Inc.229-51316RevFwww.MySCK.com installationguide REQUIREDPARTS (A)XwireUniversalSmartAdapterfor FAS T TR ACKERTimers SCK Par t No. 231- 60208-01 (B)Har nessfo r Xwir e Universal SmartAdapter i.12” SCK Part No . 222-50700-01 ii.48” SCK Part No . 222-50700-02 (C)MountingKit. SCK Par t No. 213- 50761-01 If somethingis missing,pleasecall 1-866-840-4271(8:00a.m. - 5:00p.m.EST). INSTALLATION 1.Con nectha rnessto the communication porton top of the TRACKERTimer. 2.Con nectother end of harness to the Xwi re Un iversal SmartAdapter. Mountthe SmartAdapterus in g the supplied Velcro. Not e : Mount in a pl ace the SCK XwireSmartGatewaywill receivea si gnal . 3.Verifythe LE D seq uen ce on the Sma rtAd apteris cor rec t per yourapplication by referring to the charts on page6. XwireUniversal Smar tAdapter for (FA ST .) ® TRA CKER TM TIM ERS Th e TRACKERTimer is now ready to be used as an SCK Xwire wirelessdevice. REQUIREDPA RT S (A)XwireUni ve rsa l SmartAdapte r for Fryers an d Ove ns SCK Part No. 231-60208-01 (B)Self- tapping Connectors (in clud ed) SCK Part No. 141-51026 Qt y. 2 (C ) Harness:Choose One i.SCK Part No. 222-50702-01 ii . SCK Part No…

Text truncated - open the document above for the full version.

External Photos

TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-GATEWAY Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 XWIRE- GATEWAY Page 1 of 3 EUT: FAST Model: Xwire-Gateway 33_EME/I 01/29/2001 External Photos EUT Name: FAST EUT Model: Xwire-Gateway FCC ID: U7JXWIRE-GATEWAY FCC Title 47, Part 15, SubpartC, RSS-210 Issue 8 Prepared for: Stan Vreeland Food Automated Services Techniques Inc. (FAST) 905 Honeyspot Road Stratford CT, 06615 Tel: 203-380-3510 Fax: 203-377-8187 Prepared by: TUV Rheinland of North America 336 Initiative Dr Rochester, NY 14624 Tel: (585) 426-5555 Fax: (585) 568-8338 http://www.tuv.com/ Report/Issue Date: 21 September 2011 Report Number: 31053510.001 XWIRE- GATEWAY TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-GATEWAY Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 XWIRE- GATEWAY Page 2 of 3 EUT: FAST Model: Xwire-Gateway 33_EME/I 01/29/2001 External Photos: Figure 1: Front TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-GATEWAY Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 XWIRE- GATEWAY Page 3 of 3 EUT: FAST Model: Xwire-Gateway 33_EME/I 01/29/2001 Figure 2: Back

ID Label/Location Info

TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-GATEWAY Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 XWIRE- GATEWAY Page 1 of 2 EUT: FAST Model: Xwire-Gateway 33_EME/I 01/29/2001 Label Location EUT Name: FAST EUT Model: Xwire-Gateway FCC ID: U7JXWIRE-GATEWAY FCC Title 47, Part 15, SubpartC, RSS-210 Issue 8 Prepared for: Stan Vreeland Food Automated Services Techniques Inc. (FAST) 905 Honeyspot Road Stratford CT, 06615 Tel: 203-380-3510 Fax: 203-377-8187 Prepared by: TUV Rheinland of North America 336 Initiative Dr Rochester, NY 14624 Tel: (585) 426-5555 Fax: (585) 568-8338 http://www.tuv.com/ Report/Issue Date: 21 September 2011 Report Number: 31053510.001 XWIRE- GATEWAY TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-GATEWAY Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 XWIRE- GATEWAY Page 2 of 2 EUT: FAST Model: Xwire-Gateway 33_EME/I 01/29/2001 External Photos: Figure 1: Back

Internal Photos

TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-GATEWAY Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 XWIRE-GATEWAY Page 1 of 3 EUT: FAST Model: Xwire-Gateway 33_EME/I 01/29/2001 Internal Photos EUT Name: FAST EUT Model: Xwire-Gateway FCC ID: U7JXWIRE-GATEWAY FCC Title 47, Part 15, SubpartC, RSS-210 Issue 8 Prepared for: Stan Vreeland Food Automated Services Techniques Inc. (FAST) 905 Honeyspot Road Stratford CT, 06615 Tel: 203-380-3510 Fax: 203-377-8187 Prepared by: TUV Rheinland of North America 336 Initiative Dr Rochester, NY 14624 Tel: (585) 426-5555 Fax: (585) 568-8338 http://www.tuv.com/ Report/Issue Date: 21 September 2011 Report Number: 31053510.001 XWIRE-GATEWAY TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-GATEWAY Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 XWIRE-GATEWAY Page 2 of 3 EUT: FAST Model: Xwire-Gateway 33_EME/I 01/29/2001 Internal Photos: Figure 1: Internal View - Top TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-GATEWAY Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 XWIRE-GATEWAY Page 3 of 3 EUT: FAST Model: Xwire-Gateway 33_EME/I 01/29/2001 Figure 2: Internal View - Bottom

Test Report

FCC ID: U7JXWIRE- GATEWAY Report No.: 31053510.001 XWIRE-GATEWAY.doc Page 1 of 39 The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not constitute authorization for the use of any TUV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. TÜV Rheinland Inc., 336 Initiative Drive, Rochester NY 14624, Tel: (585) 426-5555, Fax: (585) 253-1485 QF09G040 Revision 0 Electromagnetic Compatibility Test Report Prepared in accordance with FCC Part 15C and ANSI C63.10 On Wireless Kitchen Management System Gateway Food Automation – Service Techniques, Inc. (FAST) 905 Honeyspot Rd Stratford, CT 06615 Prepared by: TUV Rheinland of North America, Inc. FCC ID: U7JXWIRE- GATEWAY Report No.: 31053510.001 XWIRE-GATEWAY.doc Page 2 of 39 The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not constitute authorization for the use of any TUV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. TÜV Rheinland Inc., 336 Initiative Drive, Rochester NY 14624, Tel: (585) 426-5555, Fax: (585) 253-1485 QF09G040 Revision 0 Client: Food Automation – Service Techniques, Inc. (FAST) 905 Honeyspot Rd Stratford, CT 06615 Stan Vreeland 203-380-3510 / 203-377-8187 [email protected] Identification: Wireless Kitchen Management System Serial No.: 0LG10920001 Test item: Gateway Date tested: 12/2/2010 Testing location: TUV Rheinland of North America 336 Initiative Drive Rochester, NY 14624 U.S.A. Tel: (585) 426-5555 Fax: (585)-568-8338 Test specification: Emissions: FCC Part 15 subpart C FCC Part 15.249(a) FCC Part 15.205(a) FCC Part 15.215(a) FCC Part 15.249(a), FCC Part 15.215(c) FCC Part 15.249(3), FCC Part 2.1093, Test Result: The above product was found to be Compliant to the above test standard(s) tested by: Randall Masline reviewed by: Cecil Gittens 2 February 2011 Date Name Signature 2 February 2011 Date Name Signature Other Aspects: None Abbreviations: OK, Pass, Compliant, Complies = passed Fail, Not Compliant, Does Not Comply = failed N/A = not applicable NVLAP Lab Code (200313-0) Industry Canada BSMI US5253 34661C-1 SL2-IN-E-050R FCC ID: U7JXWIRE- GATEWAY Report No.: 31053510.001 XWIRE-GATEWAY.doc Page 3 of 39 The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not constitute authorization for the use of any TUV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. TÜV Rheinland Inc., 336 Initiative Drive, Rochester NY 14624, Tel: (585) 426-5555, Fax: (585) 253-1485 QF09G040 Revision 0 TABLE OF CONTENTS 1 GENERAL INFORMATION ......................................................................................................................... 4 1.1 SCOPE......................................................................................................................................................... 4 1.2 PURPOSE..................................................................................................................................................... 4 1.3 SUMMARY OF TEST RESULTS..................................................................................................................... 5 2 LABORATORY INFORMATION ................................................................................................................ 6 2.1 ACCREDITATIONS & ENDORSEMENTS........................................................................................................ 6 2.2 MEASUREMENT UNCERTAINTY EMISSIONS............................................................................................... 7 2.3 CALIBRATION TRACEABILITY.................................................................................................................... 8 2.4 MEASUREMENT EQUIPMENT USED............................................................................................................ 9 3 PRODUCT INFORMATION ....................................................................................................................... 10 3.1 PRODUCT DESCRIPTION............................................................................................................................ 10 3.2 EQUIPMENT MODIFICATIONS................................................................................................................... 10 3.3 TEST PLAN................................................................................................................................................ 10 4 EMISSIONS.................................................................................................................................................... 12 4.1 RADIATED EMISSIONS.............................................................................................................................. 12 4.2 FIELD STRENGTH OF FUNDAMENTAL AND HARMONIC EMISSIONS......................................................... 16 4.3 BAND EDGE REQUIREMENTS...........................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-GATEWAY Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 XWIRE-GATEWAY Page 1 of 4 EUT: FAST Model: Xwire-GATEWAY 33_EME/I 01/29/2001 Test Setup Photos EUT Name: FAST EUT Model: Xwire-GATEWAY FCC ID: U7JXWIRE-GATEWAY FCC Title 47, Part 15, SubpartC, RSS-210 Issue 8 Prepared for: Stan Vreeland Food Automated Services Techniques Inc. (FAST) 905 Honeyspot Road Stratford CT, 06615 Tel: 203-380-3510 Fax: 203-377-8187 Prepared by: TUV Rheinland of North America 336 Initiative Dr Rochester, NY 14624 Tel: (585) 426-5555 Fax: (585) 568-8338 http://www.tuv.com/ Report/Issue Date: 21 September 2011 Report Number: 31053510.001 XWIRE-GATEWAY TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-GATEWAY Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 XWIRE-GATEWAY Page 2 of 4 EUT: FAST Model: Xwire-GATEWAY 33_EME/I 01/29/2001 Test Setup Photos: Figure 1: Emissions at 3 meters TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-GATEWAY Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 XWIRE-GATEWAY Page 3 of 4 EUT: FAST Model: Xwire-GATEWAY 33_EME/I 01/29/2001 Figure 2: Emissions at O.A.T.S. TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-GATEWAY Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 XWIRE-GATEWAY Page 4 of 4 EUT: FAST Model: Xwire-GATEWAY 33_EME/I 01/29/2001 Figure 3: Temp Chamber

Contact Information

Applicant

Stanley Robert Vreeland(Hardware Engineering Manager)
[email protected]203-380-3510Fax: 203-377-8187

Test Firm

TUV Rheinland of North America Inc.Michael Moranha
[email protected]919-554-3668Fax: 919-554-3542

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.00 mW
Confidentiality
Long Term

Other Applications from Food Automation - Service Techniques, Inc.

Food quality & supply chain monitor equipment - FCC ID UJ7XWIRE-REPEATER - Food Automation - Service Techniques, Inc.
UJ7XWIRE-REPEATER

Food quality & supply chain monitor equipment

Nov 28, 2011

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Food quality & supply chain monitor equipment. - FCC ID UJ7-XWIRE-DIRECT - Food Automation - Service Techniques, Inc.
UJ7-XWIRE-DIRECT

Food quality & supply chain monitor equipment.

Nov 28, 2011

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Food quality & supply chain monitor - FCC ID UJ7-XWIRE-SENSOR - Food Automation - Service Techniques, Inc.
UJ7-XWIRE-SENSOR

Food quality & supply chain monitor

Nov 20, 2011

Equipment Class