FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Food Automation - Service Techniques, Inc./
  3. UJ7XWIRE-REPEATER

UJ7XWIRE-REPEATERFood quality & supply chain monitor equipment

Food Automation - Service Techniques, Inc.
Food quality & supply chain monitor equipment - FCC ID UJ7XWIRE-REPEATER - Food Automation - Service Techniques, Inc.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Nov 28, 2011
Application Purpose
Original Equipment
Date of Application
Nov 28, 2011
Equipment Note
Food quality & supply chain monitor equipment
Frequency Range
2405.00000000 - 2480.00000000
Company
Food Automation - Service Techniques, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

InstallationGuide SmartRepeater TM Device Direct,Inc. "...becauseyoucan'timprove whatyoudon'tmeasure" www.MySCK.com (Theseinstructionsshouldbesavedforfuturereference.) 2 ©20 08 SCK Direct, Inc. 229-51379 Rev A www.MySC K.com SmartRepeater TM Direct,Inc. NOTICES SC K Direct,Inc. is no t liable for any us e of pro duct no t in acc or - dancewith SC K Direct,Inc.’s installationand oper ati on instructions . CL EAN IN G Us in g a clean damp cloth, wipe downthe Smart Repeate r when necessaryusing a commercial qual ity foo dservice-approved detergent. DO NOT IMME RS E. NEVERuse chemicalor abras ive cleanerson the Smar tR epeater. TOOLSRE QUI RED FOR IN STA LLATION Drill Bit: 3/16” if using wall anc ho r, or #50 if in st alling int o metal Philli ps Screwdriv ers IN CLUDEDPARTS Pleaseco nfirm that these par ts have shi pped wi th your ord er: SmartRepeater:231-60233-01 MountingKit: 213- 50641 PowerSupplyMo untingKit: 213-50759-01 StrainRe lief Kit: 213-50760-01 If something is missing,pleasecall 1- 866-840-4271(8:00 a.m. - 5:00 p.m. EST). BEF ORE YOUINSTALL SmartRepeaters shouldbe ins talled af te r th e inst al la tio n of your SCK SmartDi rect 2 TM , SC K Kit chen Advisor TM , or (FAST.)Xwi re TM WirelessGateway. Changes or modifications not exp re ssly approvedby SCK Direct,In c. couldvoidth e user'saut hority to operatethe equipment. NOTE: Thi s eq uipm ent has been testedand foun d to comply wit h the lim its for a Cla ss B digita l devic e, pur sua nt to Pa rt 15 of the FCC Rules.Theselim its ar e de signedto pr ovid e reas ona ble pro tectionagainstharmful inte rfer ence in a resid en tia l ins tall a- tion . This equipment gener ates, uses an d can rad ia te radi o frequency energyand , if not installedan d used in accord ance wit h the instructions , may cause harm fu l interf er ence to ra di o com munications.However, ther e is no gu ara nt ee th at int erf er - ence will no t occur in a pa rticu lar install at ion . If thi s equ ipment does ca use harmfulinter fer ence to radio or tel evis ion rece pt ion , whichcan be dete rminedby turningth e equ ipmentof f an d on , the user is encouragedto try to corre ct th e int erf er en ce by one or more of the following measu res : Reor ien t or relo cate the receiv ing anten na . Increasethe separationbetween the equi pmen t and receiver. Conn ect the equipmentinto an ou tlet on a cir cuit di ff erent from th at to whichthe receiv er is co nnected. Consultthe de aler for help. This documentcontainscon fiden tial information. The dissemination, publication , copying,or duplicatio n of this documentor the sof tw are describedhereinwithoutprior writt en aut horizationis strictl y prohibit ed. POWERSUP PL Y 126-10033 PO WER CO RD OPT ION S 126- 10028:Po we r Cord U.S. 126- 10029:Po we r Cord Eur o, Round 126- 10030:Po we r Cord UK, Flat 3 ©2008 SCK Di rec t, Inc. 229-51379 Rev A www.MySC K.com ST RAINRELIEFSE TU P 1. Applythe su ppliedTy-wrapadhe sive-backed mou nt (150- 150 28) on the bottomside of the SmartR epeat er (1) on e inch from the powersupplyplug. 2. Run the su ppliedTy- wrap (150-15005R)thr ough one of the holes on the adhesivebac ked mount. 3. Plug the powersupplyinto the Sma rtR epe ater. Take th e powercord and Ty-wrapit so the powerco rd does not becomeunp luggedwhen mo untedon a surf ace. installationguide This documentcontainscon fidentialinfor matio n. The dissemination, publication , copyi ng, or duplicatio n of this documentor the softw are des cribedhereinwithoutprior writt en aut horizationis strictl y prohibited. MOUNTING IN STRUCTIONS 1. Choo se a lo cationfor the SmartRepeater to be inst all ed (within8 fee t of an outl et). Use the Smart Repe at er mount - in g bra cket templatefou nd in this gu ide to mark th e locationsof the 2 mo untingholes. View th e tentativepos itioningand ensu re the re are no lo ca - tion problems. Drill th e 2 pilo t holes . (If you are us in g the suppliedwall anchors,use a 3/16 bit. For mounting int o sheet metal,use a #50 bit.) Ins ert screwsinto th e mou nt in g brackethole s and tighten. 2. Clip the Sm art Repe ater into its brack et . 3. Plug the Sm artRepeater int o outlet . ALTERNATIVEMO UNTING OPT ION USING SUPPLIEDVELCRO 1. Choo se a lo cationto inst all the SmartRepe at er (within8 fe et of an outlet). 2. Cleanthe mou nting sur fac e and bac k of the Sm artRepeat er with the suppli ed alc oho l wipe. 3. Ad here one piece of the suppliedVel cro to the sur fa ce wh ere you want to mountthe Smar tRepe at er. Make sure the re will be no obs tru ction s onc e the SmartRepeateris mou nted. 4. Ad here the secondpiece of su ppliedVelcroto the ba ck sid e of the SmartRepeater. Then ad here the SmartRepea ter onto the mountinglocation. 5. Plug the Sm artRepeater int o outlet . 4 ©20 08 SCK Direct, Inc. 229-51379 Rev A www.MySC K.com Direct,Inc. This documentcontainscon fiden tial information. The dissemination, publication , copying,or duplicatio n of this documentor the sof tw are describedhereinwithoutprior writt en aut horizationis strictl y prohibit ed. SmartRepeater TM Sta tus LED Chart SignalLEDs Troubleshooting / LED Cod es SignalStr eng th In dic ato r IN DICATORCH ARTS LED ColorLED BlinkRateDescr ipt ion REDSolid On Device is connectedas a ro uter REDSlo w Device is wa iting for data from its pa rent node REDVery Fas t Device is communicat - ing with another devic e as a router.Signalbars shouldex ist . GRE ENSolid On Device is connectedas a coordinator GRE ENVery Fas t Device is communicat - ing with another devic e as a coordinator. Signal bars sh ould ex ist. LED Acti onDescri ption Strobeeffe ct using all LEDs Deviceis scanningthe channelsfor avai lable networks. LED s alt er nate bein g lit in seq ue nce for a per iod of time. A diagn osti c co mmandwas iss ued to this deviceto blink the LEDs in a reco g- nizablepatternfor a set amountof time . Bar sLink Quality NONE(0)No signalor No messagesrecei ved ONE (1)Mo deratesignal TWO(2)Good signal THR EE(3)Exc ellentsigna…

Text truncated - open the document above for the full version.

External Photos

TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-REPEATER Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 XWIRE-REPEATER Page 1 of 2 EUT: FAST Model: Xwire-Repeater 33_EME/I 01/29/2001 External Photos EUT Name: FAST EUT Model: Xwire-Repeater FCC ID: U7JXWIRE-REPEATER FCC Title 47, Part 15, SubpartC, RSS-210 Issue 8 Prepared for: Stan Vreeland Food Automated Services Techniques Inc. (FAST) 905 Honeyspot Road Stratford CT, 06615 Tel: 203-380-3510 Fax: 203-377-8187 Prepared by: TUV Rheinland of North America 336 Initiative Dr Rochester, NY 14624 Tel: (585) 426-5555 Fax: (585) 568-8338 http://www.tuv.com/ Report/Issue Date: 4 November 2011 Report Number: 31053510.001 XWIRE-REPEATER TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-REPEATER Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 XWIRE-REPEATER Page 2 of 2 EUT: FAST Model: Xwire-Repeater 33_EME/I 01/29/2001 External Photos: Figure 1: Front Figure 2: Back

ID Label/Location Info

TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-REPEATER Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 XWIRE-REPEATER Page 1 of 2 EUT: FAST Model: Xwire-Repeater 33_EME/I 01/29/2001 Label Location EUT Name: FAST EUT Model: Xwire-Repeater FCC ID: U7JXWIRE-REPEATER FCC Title 47, Part 15, SubpartC, RSS-210 Issue 8 Prepared for: Stan Vreeland Food Automated Services Techniques Inc. (FAST) 905 Honeyspot Road Stratford CT, 06615 Tel: 203-380-3510 Fax: 203-377-8187 Prepared by: TUV Rheinland of North America 336 Initiative Dr Rochester, NY 14624 Tel: (585) 426-5555 Fax: (585) 568-8338 http://www.tuv.com/ Report/Issue Date: 21 September 2011 Report Number: 31053510.001 XWIRE-REPEATER TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-REPEATER Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 XWIRE-REPEATER Page 2 of 2 EUT: FAST Model: Xwire-Repeater 33_EME/I 01/29/2001 External Photos: Figure 2: Back

Internal Photos

TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-REPEATER Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 U7JXWIRE-REPEATER Page 1 of 2 EUT: FAST Model: Xwire-Repeater 33_EME/I 01/29/2001 Internal Photos EUT Name: FAST EUT Model: Xwire-Repeater FCC ID: U7JXWIRE-REPEATER FCC Title 47, Part 15, SubpartC, RSS-210 Issue 8 Prepared for: Stan Vreeland Food Automated Services Techniques Inc. (FAST) 905 Honeyspot Road Stratford CT, 06615 Tel: 203-380-3510 Fax: 203-377-8187 Prepared by: TUV Rheinland of North America 336 Initiative Dr Rochester, NY 14624 Tel: (585) 426-5555 Fax: (585) 568-8338 http://www.tuv.com/ Report/Issue Date: 21 September 2011 Report Number: 31053510.001 U7JXWIRE-REPEATER TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-REPEATER Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 U7JXWIRE-REPEATER Page 2 of 2 EUT: FAST Model: Xwire-Repeater 33_EME/I 01/29/2001 Internal Photos: Figure 1: Internal View Antenna Figure 2: Internal View -

Test Report

FCC ID: U7JXWIRE- REPEATER Report No.: 31053510.001 XWIRE- REPEATER.doc Page 1 of 42 The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not constitute authorization for the use of any TUV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. TÜV Rheinland Inc., 336 Initiative Drive, Rochester NY 14624, Tel: (585) 426-5555, Fax: (585) 253-1485 QF09G040 Revision 0 Electromagnetic Compatibility Test Report Prepared in accordance with FCC Part 15C and ANSI C63.10 On Wireless Kitchen Management System Repeater Food Automation – Service Techniques, Inc. (FAST) 905 Honeyspot Rd Stratford, CT 06615 Prepared by: TUV Rheinland of North America, Inc. FCC ID: U7JXWIRE- REPEATER Report No.: 31053510.001 XWIRE- REPEATER.doc Page 2 of 42 The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not constitute authorization for the use of any TUV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. TÜV Rheinland Inc., 336 Initiative Drive, Rochester NY 14624, Tel: (585) 426-5555, Fax: (585) 253-1485 QF09G040 Revision 0 Client: Food Automation – Service Techniques, Inc. (FAST) 905 Honeyspot Rd Stratford, CT 06615 Stan Vreeland 203-380-3510 / 203-377-8187 [email protected] Identification: Wireless Kitchen Management System Serial No.: 0N09224020 Test item: Repeater Date tested: 12/2/2010 Testing location: TUV Rheinland of North America 336 Initiative Drive Rochester, NY 14624 U.S.A. Tel: (585) 426-5555 Fax: (585)-568-8338 Test specification: Emissions: FCC Part 15 subpart C FCC Part 15.249(a) FCC Part 15.205(a) FCC Part 15.215(a) FCC Part 15.249(a), FCC Part 15.215(c) FCC Part 15.249(3), FCC Part 2.1093, Test Result: The above product was found to be Compliant to the above test standard(s) tested by: Randall Masline reviewed by: Cecil Gittens 2 February 2011 Date Name Signature 2 February 2011 Date Name Signature Other Aspects: None Abbreviations: OK, Pass, Compliant, Complies = passed Fail, Not Compliant, Does Not Comply = failed N/A = not applicable NVLAP Lab Code (200313-0) Industry Canada BSMI US5253 34661C-1 SL2-IN-E-050R FCC ID: U7JXWIRE- REPEATER Report No.: 31053510.001 XWIRE- REPEATER.doc Page 3 of 42 The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not constitute authorization for the use of any TUV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. TÜV Rheinland Inc., 336 Initiative Drive, Rochester NY 14624, Tel: (585) 426-5555, Fax: (585) 253-1485 QF09G040 Revision 0 TABLE OF CONTENTS 1 GENERAL INFORMATION ......................................................................................................................... 4 1.1 SCOPE......................................................................................................................................................... 4 1.2 PURPOSE..................................................................................................................................................... 4 1.3 SUMMARY OF TEST RESULTS..................................................................................................................... 5 2 LABORATORY INFORMATION ................................................................................................................ 6 2.1 ACCREDITATIONS & ENDORSEMENTS........................................................................................................ 6 2.2 MEASUREMENT UNCERTAINTY EMISSIONS............................................................................................... 7 2.3 CALIBRATION TRACEABILITY.................................................................................................................... 8 2.4 MEASUREMENT EQUIPMENT USED............................................................................................................ 9 3 PRODUCT INFORMATION ....................................................................................................................... 10 3.1 PRODUCT DESCRIPTION............................................................................................................................ 10 3.2 EQUIPMENT MODIFICATIONS................................................................................................................... 10 3.3 TEST PLAN................................................................................................................................................ 10 4 EMISSIONS.................................................................................................................................................... 12 4.1 RADIATED EMISSIONS.............................................................................................................................. 12 4.2 CONDUCTED EMISSIONS........................................................................................................................... 16 4.3 FIELD STRENGTH OF FUNDAMENTAL AND HARM…

Text truncated - open the document above for the full version.

Test Setup Photos

TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-REPEATER Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 XWIRE-REPEATER Page 1 of 2 EUT: FAST Model: Xwire-Repeater 33_EME/I 01/29/2001 External Photos EUT Name: FAST EUT Model: Xwire-Repeater FCC ID: U7JXWIRE-REPEATER FCC Title 47, Part 15, SubpartC, RSS-210 Issue 8 Prepared for: Stan Vreeland Food Automated Services Techniques Inc. (FAST) 905 Honeyspot Road Stratford CT, 06615 Tel: 203-380-3510 Fax: 203-377-8187 Prepared by: TUV Rheinland of North America 336 Initiative Dr Rochester, NY 14624 Tel: (585) 426-5555 Fax: (585) 568-8338 http://www.tuv.com/ Report/Issue Date: 21 September 2011 Report Number: 31053510.001 XWIRE-REPEATER TUV Rheinland 336 Initiative Dr., Rochester, NY 14624 FCC ID: U7JXWIRE-REPEATER Tel: (585) 426-5555, Fax: (585) 568-8338 Report Number: 31053510.001 XWIRE-REPEATER Page 2 of 2 EUT: FAST Model: Xwire-Repeater 33_EME/I 01/29/2001 External Photos: Figure 1: Front Figure 2: Back

Contact Information

Applicant

Stanley Robert Vreeland(Hardware Engineering Manager)
[email protected]203-380-3510Fax: 203-377-8187

Test Firm

TUV Rheinland of North America Inc.Cecil Gittens
[email protected]585-426-5555Fax: 585-568-8338

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.00 mW
Confidentiality
Long Term

Other Applications from Food Automation - Service Techniques, Inc.

Food quality & supply chain monitor equipment. - FCC ID UJ7-XWIRE-DIRECT - Food Automation - Service Techniques, Inc.
UJ7-XWIRE-DIRECT

Food quality & supply chain monitor equipment.

Nov 28, 2011

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Food quality and supply chain monitor equipment - FCC ID UJ7-XWIRE-GATEWAY - Food Automation - Service Techniques, Inc.
UJ7-XWIRE-GATEWAY

Food quality and supply chain monitor equipment

Nov 20, 2011

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Food quality & supply chain monitor - FCC ID UJ7-XWIRE-SENSOR - Food Automation - Service Techniques, Inc.
UJ7-XWIRE-SENSOR

Food quality & supply chain monitor

Nov 20, 2011

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter