Lathem Time Corporation
Lathem Time Corporation - FCC ID UP3-PCPROX - Lathem Time Corporation
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 02, 2021
Application Purpose
Original Equipment
Date of Application
Aug 01, 2021
Equipment Note
Lathem Time Corporation
Frequency Range
2412.00000000 - 2462.00000000
Company
Lathem Time Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

PCPROX QuickStart Guide Download Users GuideAdd to PayClock Online Download the complete User’s Guide at www.lathem.com/pcproxguide Data = WiFiData = Ethernet Power = Wall Adapter Power = Wall Adapter Data & Power = Ethernet Note: Existing network must be set up for POE. Please verify with your I.T. Dept. Wi-FiEthernetPower-Over-Ethernet (POE) a. Add your new PCPROX to your PayClock Online database before installation. b. Login to www.payclock.com, select Clocks, then New, choose PCPROX, enter the Serial Number and Save. c. The serial number is located on back of PCPROX or on box label. The PCPROX offers three different connection options: 12 3 Mount bracket Secure PCPROX PCPROX Home Screen Functions Connect cables Plug in power Hang PCPROX Connect network Mount bracket to wall Secure PCPROX with locking screw The clock Admin passcode is 99999. This can be changed in the clock’s Advanced tab in PayClock.com. Connect cables as needed to back of PCPROX Plug in power adapter to wall outlet and connect Ethernet cable if applicable. Hang PCPROX on wall bracket Follow welcome instructions on PCPROX screen to connect to network 45in. Mount bracket 45” from the floor, close to AC power and ethernet source if applicable. Do not use with POE NO ETHERNET12V/DCUSB USB COMNC View Total Hours Enter Tips or Amounts Supervisor Menu Clock In/Out with PIN Trans fer Departments Admin Settings Menu USG0122B 456 789 For help, call (404) 691-1064 Monday – Friday, 8a – 7p Eastern Time www.lathem.com/support FCC WARNING This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of t he following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with minimum distance between 20cm the radiator your body. This transmitter is restricted to indoor use in the 5150MHz to 5250MHz frequency range.

Attestation Statements

Lathem Time Corporation. Model difference statement Product Name: Lathem Time Corporation Model N o.: PCPROX, UP3PCPROX We (Lathem Time Corporation., 210 The Bluffs, Suite 107 SW Austell, GA 30168 United States) hereby state that all the models are of the same circuit and RF module, except the model No.. Signature: Name: Lance Whipple Title: Vice President Tel: 404-691-0400 Email: [email protected] Date: 7.9.2021

Cover Letter(s)

C5266091_X10_Ed.2 1/1 Lathem Time Corporation. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 7/9/2021 Subject: Request for Confidentiality FCC ID: UP3-PCPROX To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: Lance Whipple Title: Vice President

External Photos

1 - Page 1 of 13 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] APPENDIX 1- EUT PHOTO Photo 1 (For model PCPROX) Photo 2 1 - Page 2 of 13 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 3 Photo 4 1 - Page 3 of 13 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 5 Photo 6 1 - Page 4 of 13 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 7 Photo 8 1 - Page 5 of 13 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 9

Internal Photos

1 - Page 6 of 13 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 10 1 - Page 7 of 13 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 11 Photo 12 RFIDCoil ANT 5GWIFI ANT, 2.4GWIFI ANT, BT ANT 1 - Page 8 of 13 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 13 Photo 14 1 - Page 9 of 13 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 15 Photo 16 1 - Page 10 of 13 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 17 Photo 18 1 - Page 11 of 13 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 19 Photo 20 1 - Page 12 of 13 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 21 Photo 22 1 - Page 13 of 13 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 23 Photo 24 ---END OF REPORT----

RF Exposure Info

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] RF EXPOSURE Test Report Report No.: MTi210312007-01E6 Date of issue: May 21, 2021 Applicant: Lathem Time Corporation Product name: Lathem Time Corporation Model(s): PCPROX, UP3PCPROX FCC ID: UP3-PCPROX Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 8 - Report No.: MTi210312007-01E6 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Instructions 1. The report shall not be partially reproduced without the written consent of the laboratory; 2. The test results of this report are only responsible for the samples submitted; 3. This report is invalid without the seal and signature of the laboratory; 4. This report is invalid if transferred, altered or tampered with in any form without authorization; 5. Any objection to this report shall be submitted to the laboratory within 15 days from the date of receipt of the report. - Page 3 of 8 - Report No.: MTi210312007-01E6 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] TEST RESULT CERTIFICATION Applicant’s name .................... : Lathem Time Corporation Address .................................. : 210 The Bluffs, Suite 107 SW Austell, GA 30168 United States Manufacturer's Name ............. : SHENZHEN HEROFUN BIO-TECH CO., LTD Address .................................. : West 401, Building A2, TianRui Industrial Park, No. 35 FuYuan 1st Road, XinHe Community, FuHai Street, BaoAn District, Shenzhen, China Product description Product name ......................... : Lathem Time Corporation Trademark ............................. : Lathem Model Name .......................... : PCPROX Serial Model ............................ UP3PCPROX Standards ............................... : N/A Test procedure ....................... : KDB 447498 D01 v06 Date of Test Date (s) of performance of tests ............ : Apr. 12, 2021 ~ May 13, 2021 Test Result ............................................. : Pass This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Testing Engineer : (Danny Xu) Technical Manager : (Leo Su) Authorized Signatory : (Tom Xue) - Page 4 of 8 - Report No.: MTi210312007-01E6 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] RF EXPOSURE EVALUATION According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) Radiation as specified in §1.1307(b) Limits for Maximum Permissible Exposure (MPE) MPE Calculation Method Friis transmission formula: Pd= (Pout*G)\ (4*pi*R 2 ) Where Pd= Power density in mW/cm2 Pout=output power to antenna in mW G= Numeric gain of the antenna relative to isotropic antenna Pi=3.1415926 R= distance between observation point and center of the radiator in cm(20cm) Pd the limit of MPE, 1mW/cm2. If we know the maximum gain of the antenna and total power input to the antenna, through the calculation, we will know the distance where the MPE limit is reached. - Page 5 of 8 - Report No.: MTi210312007-01E6 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Measurement Result BT/BLE: Operation Frequency: 2402-2480MHz, Power density limited: 1mW/ cm 2 2.4GWiFi: Operation Frequency: WIFI 802.11b/g/n HT20: 2412-2462MHz, Power density limited: 1mW/ cm 2 5GWiFi: 802.11a: 20 MHz 802.11n: 20 MHz, 40 MHz 802.11ac: 20 MHz, 40 MHz, 80MHz Antenna Type: FPC Antenna; WIFI antenna gain: 1.13dBi R=20cm mW=10^(dBm/10) antenna gain Numeric=10^(dBi/10)= 10^(1.13/10)=1.30 BR&EDR: Chann el Freq. (MHz) modulatio n conducte d power Tune- up powe r (dBm ) Max Antenna Evaluation result Power density Limits (dBm) tune-up power Gain (mW/cm2 ) (mW/c m2) (dBm) (mW) (dBi) Nume ric 2402 GFSK 5.275 6±1 7 5.012 1.13 1.30 0.0013 1 2441 6.758 6±1 7 5.012 1.13 1.30 0.0013 1 2480 6.706 6±1 7 5.012 1.13 1.30 0.0013 1 2402 π/4- DQPSK 3.146 4±1 5 3.162 1.13 1.30 0.0008 1 2441 4.129 4±1 5 3.162 1.13 1.30 0.0008 1 2480 4.158 4±1 5 3.162 1.13 1.30 0.0008 1 2402 8DPSK 3.758 4±1 5 3.162 1.13 1.30 0.0008 1 2441 4.542 4±1 5 3.162 1.13 1.30 0.0008 1 2480 4.544 4±1 5 3.162 1.13 1.30 0.0008 1 - Page 6 of 8 - Report No.: MTi210312007-01E6 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] BLE: Chann el Freq. (MHz) modulatio n conducte d power Tune- up power (dBm) Max Antenna Evaluation result Power density Limits (dBm) tune-up power Gain (mW/cm2 ) (mW/cm 2) (dBm) (mW) (dBi) Num eric 2402 GFSK 4.639 5±1 6 3.981 1.13 1.30 0.0010 1 2440 5.589 5±1 6 3.981 1.13 1.30 0.0010 1 2480 5.987 5±1 6 3.981 1.13 1.30 0.0010 1 2.4GWiFi: Channel Freq. (MHz) modulation conducted power Tune- up power Max Antenna Evaluation result at 20cm Power density Limits (dBm) (dBm) tune-up power Gain Power density(mW/cm2 ) (mW/cm2) (dBm) (mW) Numeric Ant A Ant A Ant A Ant A Ant A Ant A …

Text truncated - open the document above for the full version.

Test Report

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Test Report Report No.: MTi210312007-01E2 Date of issue: May 21, 2021 Applicant: Lathem Time Corporation Product name: Lathem Time Corporation Model(s): PCPROX, UP3PCPROX FCC ID: UP3-PCPROX Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 54 - Report No.: MTi210312007-01E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Instructions 1. The report shall not be partially reproduced without the written consent of the laboratory; 2. The test results of this report are only responsible for the samples submitted; 3. This report is invalid without the seal and signature of the laboratory; 4. This report is invalid if transferred, altered or tampered with in any form without authorization; 5. Any objection to this report shall be submitted to the laboratory within 15 days from the date of receipt of the report. - Page 3 of 54 - Report No.: MTi210312007-01E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Table of Contents 1 GENERAL INFORMATION .......................................................................................................................................... 6 1.1 DESCRIPTION OF EUT ................................................................................................................................................... 6 1.2 OPERATION CHANNEL LIST .............................................................................................................................................. 7 1.3 TEST CHANNEL LIST ....................................................................................................................................................... 7 1.4 ANCILLARY EQUIPMENT LIST ........................................................................................................................................... 7 1.5 DESCRIPTION OF SUPPORT UNITS .................................................................................................................................... 8 2 SUMMARY OF TEST RES U LT S .................................................................................................................................... 9 3 TEST FACILITIES AND ACCREDITATIONS ................................................................................................................... 10 3.1 TEST LABORATORY ...................................................................................................................................................... 10 3.2 ENVIRONMENTAL CONDITIONS ...................................................................................................................................... 10 3.3 MEASUREMENT UNCERTAINTY ...................................................................................................................................... 10 3.4 TEST SOFTWARE ......................................................................................................................................................... 10 4 EQUIPMENT LIST .................................................................................................................................................... 11 5 TEST RESULT ........................................................................................................................................................... 12 5.1 ANTENNA REQUIREMENT ............................................................................................................................................. 12 5.1.1 Standard requirement ....................................................................................................................................... 12 5.1.2 EUT antenna ..................................................................................................................................................... 12 5.2 PEAK OUTPUT POWER ................................................................................................................................................. 13 5.2.1 Limit .................................................................................................................................................................. 13 5.2.2 Test setup .......................................................................................................................................................... 13 5.2.3 Test procedure ................................................................................................................................................... 13 5.2.4 Te s t results......................................................................................................................................................... 14 5.3 POWER SPECTRAL DENSITY ........................................................................................................................................... 15 5.3.1 Limit .................................................................................................................................................................. 15 5.3.2 Test setup .......................................................................................................................................................... 15 5.3.3 Test procedure ................................................................................................................................................... 15 5.3.4 Test…

Text truncated - open the document above for the full version.

Test Report

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Test Report Report No.: MTi210312007-01E4 Date of issue: May 21, 2021 Applicant: Lathem Time Corporation Product name: Lathem Time Corporation Model(s): PCPROX, UP3PCPROX FCC ID: UP3-PCPROX Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 46 - Report No.: MTi210312007-01E4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Instructions 1. The report shall not be partially reproduced without the written consent of the laboratory; 2. The test results of this report are only responsible for the samples submitted; 3. This report is invalid without the seal and signature of the laboratory; 4. This report is invalid if transferred, altered or tampered with in any form without authorization; 5. Any objection to this report shall be submitted to the laboratory within 15 days from the date of receipt of the report. - Page 3 of 46 - Report No.: MTi210312007-01E4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Table of Contents 1. GENERAL INFORMATION ................................................................................................................................... 6 1.1. DESCRIPTION OF EUT ................................................................................................................................................... 6 1.2. OPERATION CHANNEL LIST .............................................................................................................................................. 6 1.3. TEST CHANNEL LIST ....................................................................................................................................................... 7 1.4. ANCILLARY EQUIPMENT LIST ........................................................................................................................................... 7 1.5. DESCRIPTION OF SUPPORT UNITS .................................................................................................................................... 7 2. SUMMARY OF TEST RESULT S .......................................................................................................................... 8 3. TEST FACILITIES AND ACCREDITATIONS ...................................................................................................... 9 3.1. TEST LABORATORY ........................................................................................................................................................ 9 3.2. ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 9 3.3. MEASUREMENT UNCERTAINTY ........................................................................................................................................ 9 3.4. TEST SOFTWARE ........................................................................................................................................................... 9 4. EQUIPMENT LIST ............................................................................................................................................... 10 5. TEST RESULT ..................................................................................................................................................... 11 5.1. ANTENNA REQUIREMENT ............................................................................................................................................. 11 5.1.1 Standard Requirement ...................................................................................................................................... 11 5.1.2 EUT Antenna ..................................................................................................................................................... 11 5.2. PEAK OUTPUT POWER TEST ......................................................................................................................................... 12 5.2.1 Limit .................................................................................................................................................................. 12 5.2.2 Test setup .......................................................................................................................................................... 12 5.2.3 Test Procedure ................................................................................................................................................... 12 5.2.4 Te s t Results ........................................................................................................................................................ 12 5.3. CONDUCTED EMISSION ................................................................................................................................................ 15 5.3.1 Limits ................................................................................................................................................................. 15 5.3.2 Te s t Setup .......................................................................................................................................................... 15 5.3.3 Te st Procedure ................................................................................................................................................... 16 5.3.4 Te s t Results ............…

Text truncated - open the document above for the full version.

Test Setup Photos

Model: PCPROX Radiated emission Conducted emission Radiated emission Conducted emission

Contact Information

Applicant

Lance Whipple(Vice President)
[email protected]404-691-0400Fax: 404-420-2048

Technical Contact

Shenzhen Microtest Co., LtdLeo Su
[email protected]86-755 88850135

Shenzhen · China

Test Firm

Shenzhen Microtest Co., Ltd.Phoebe Cui
[email protected]0755 88850135 1393

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz40.50 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Lathem Time Corporation

Time Clock - FCC ID UP3-PCTOUCH - Lathem Time Corporation
UP3-PCTOUCH

Time Clock

Sep 22, 2023

Equipment Class

NII - Unlicensed National Information Infrastructure TX
PayClock Terminal - FCC ID UP3PC6 - Lathem Time Corporation
UP3PC6

PayClock Terminal

Jul 22, 2010

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
PC50 TIME & ATTENDANCE DATA TERMINAL - FCC ID UP3PC50 - Lathem Time Corporation
UP3PC50

PC50 TIME & ATTENDANCE DATA TERMINAL

Nov 06, 2006

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz