UQY-HF1000RFID Tag Reader

WaveMark, Inc.
RFID Tag Reader - FCC ID UQY-HF1000 - WaveMark, Inc.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Feb 15, 2007
Application Purpose
Original Equipment
Date of Application
Feb 15, 2007
Equipment Note
RFID Tag Reader
Frequency Range
13.56000000 - 13.56000000
Company
WaveMark, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗
↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

WaveMark Cabinet P/N 01-0001 Installation Manual This manual is P/N 99-0002, Version 1.00 WaveMark, Inc. - Proprietary and Confidential 99-0002 Version 1.00 Page 2 of 11 Document Revision History Rev. Notes/Changes Date 1.00 Initial Release Jan 23, 2007 Notice of FCC Compliance Changes or modifications not expressly approved by WaveMark, Inc. could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This product must be professionally installed by WaveMark trained installation personnel and must only be serviced by WaveMark trained service personnel. WaveMark, Inc. - Proprietary and Confidential 99-0002 Version 1.00 Page 3 of 11 Table of Contents 1. Working Safely....................................................................................4 2. Unpacking the Cabinet .......................................................................5 3. Placing the Cabinet ............................................................................6 4. Cabinet Installation.............................................................................7 5. Hardware Checkout ............................................................................9 6. Product Specifications ..................................................................... 10 7. Cabinet Servicing ............................................................................. 11 WaveMark, Inc. - Proprietary and Confidential 99-0002 Version 1.00 Page 4 of 11 1. Working Safely It is WaveMark’s highest priority that all field installations comply with the company’s installation and safety procedures and any safety procedures in place at the location of installation. In order to assure that WaveMark equipment is installed in a safe manner and in compliance with WaveMark’s installation guidelines only factory trained personnel are authorized to install or service WaveMark products. This WaveMark product contains no user-serviceable components. All personnel involved with the transportation, installation, commissioning or repair of WaveMark equipment are required to follow WaveMark’s Infection Control Practice policy (effective 12/2006). WaveMark, Inc. - Proprietary and Confidential 99-0002 Version 1.00 Page 5 of 11 2. Unpacking the Cabinet Step 1 When the cabinet arrives, it will need to be unpacked. WaveMark ships its cabinets on pallets with built-in ramps. Once the packing material has been removed from the outside of the cabinet, unlock the front wheels of the Cabinet, lower the ramp, and carefully guide the Cabinet down the ramp. Step 2 With the packing material removed inspect the cabinet for damage. If the Cabinet is obviously damaged notify the shipping company immediately. Don’t proceed with the installation of any damaged Cabinet. Step 3 Set the pallet aside and discard the rest of the shipping material as directed by the facility’s shipping personnel. When all Cabinets have been unpacked, stack the WaveMark pallets and coordinate with shipping personnel to return then to WaveMark’s designated storage facility; this is NOT WaveMark’s corporate address. WaveMark, Inc. - Proprietary and Confidential 99-0002 Version 1.00 Page 6 of 11 3. Placing the Cabinet Step 1 Before moving a Cabinet up to its location in the facility, walk the route and note any obstructions such as signs on the walls or ceilings, or any flooring issues such as elevator thresholds that might be a problem for the Cabinet’s wheels. Step 2 Identify where the Cabinet is to be placed and locate an easily accessible socket outlet and the nearest usable Ethernet jack. The Cabinet MUST be connected to a power outlet that is properly grounded and has a three wire connection. Step 3 The Cabinet is designed to be rolled over smooth flooring; the cabinet should never be tilted, placed on its side, or rolled across parking lots. If necessary relocate the Cabinet on its shipping pallet to avoid these situations. When crossing elevator entrances use the portable threshold provided to prevent the Cabinet’s wheels from becoming lodged in the elevator entrance track. Note that the Cabinet has been designed to be very stable, but moving too quickly and pushing against the top of the Cabinet may cause it to tip. When placing the cabinet move slowly and push or pull only the lower half of the Cabinet. Step 4 Be sure the Cabinet is installed in a suitable environment. The environment should be free from airborne corrosive agents and excessive dust. The floor should be dry and the cabinet should not be placed in an area where it would be exposed to dripping water. Step 5 Inspect the exterior of the Cabinet and if it’s become marred during shipping clean the exterior plastics with a mild household cleaner or isopropyl alcohol. Other solvents that are more harsh may damage or discolor the Cabinet’s exterior and should NOT be used. WaveMark, Inc. - Proprietary and Confidential 99-0002 Version 1.00 Page 7 of 11 4. Cabinet Installation Step 1 Carefully wheel the cabinet to its location. Move the Cabinet slowly and carefully to avoid objects and people who may be traveling in the same corridors. Use the moveable threshold provided when traveling over rough spots, such as elevator entrances. Step 2 When the cabinet is in place, remove the top and bottom Cabinet Back pieces. Each antenna is held in place with a protective foam insert. Remove and discard the inserts for all the Antennas. Step 3 Remove the power cable from the cabinet bottom and set it aside; DO NOT connect power to the Cabinet at this time! Step 4 Check the location of the Mux board and the DCP PC, and all of the interconnect wiring. Be sure there are no loose, unconnected wires in the base of the Cabinet. Step 5 Remove the Front Access Panel and chec…

Text truncated - open the document above for the full version.

Cover Letter(s)

Memo To: TCB From: Rick Desmarais Subj: WaveMark HF1000 Cabinet Date: February 9, 2007 All WaveMark products will only be installed by WaveMark trained personnel. Currently WaveMark has two field engineers on staff that perform field installations, upgrades and repairs. When shipped to an installation location the products may be removed from their packaging by hospital shipping/receiving personnel. However, are still site inspected, tested and brought online only by WaveMark trained personnel. WaveMark has created a simple release process in order to assure consistency in production and to manage product changes. The Engineering Change Board meets weekly to review, discuss and approve/deny product changes. Currently the Engineering Change Board members consist of the VP Engineering and Hardware Engineering Manager. It will be expanded to add other WaveMark personnel as the company grows. Hardware Engineering is currently responsible for manufacturing and inventory. Bills of materials as well as component specification sheets for all critical components are available at the receiving area. Incoming inspection is performed on all critical components. Purchasing is managed from an approved vendor list maintained by Hardware Engineering. All cabinet product builds have a documented assembly procedure that illustrates how each of the cabinet sub-assemblies is built and how an entire cabinet is completed using those sub-assemblies. The changes implemented at onsite testing have been incorporated into the build procedure as follows. 1. Each antenna board BOM has been updated to include the Steward part number LFB159079-000 (WaveMark P/N 41-0003) onto the circuit board, attached with tie wraps. WaveMark’s contract manufacturer has been given instructions on implementing this change. 2. Two Steward ferrites with part number 28A3851-0A2 (WaveMark P/N 41-0005) have been added to the BOM for the cabinet and the assembly manual includes instructions for attaching these to the two serial cables attached to the PC. 3. One Steward ferrite with part number 28A2029-0A2 (WaveMark P/N 41-0004) has been added to the BOM for the cabinet and the assembly manual includes instructions for attaching this to the the Mux to Motor board connection cable. 4. One Steward ferrite with part number 28A0593-0A2 (WaveMark P/N 41-0006) has been added to the BOM for the cabinet and the assembly manual includes instructions for attaching this to the floppy disk drive power cable extender that comes from the back of the PC. 5. A part number has been created and vendor specified for adhesive backed copper tape (WaveMark P/N 86-0014) and it has been added to the BOM. Instructions for attaching it to the cabinet just under the BNC connector supports for the antenna coax cable have been added to the assembly manual. 6. A part number has been created and vendor specified for conductive acrylic backed aluminum foil (WaveMark P/N 86-0015) with a width of two inches. Instructions for attaching it to the cabinet at the back of the PC have been added to the assembly manual.

External Photos

Company: Wavemark EG1106-1 FCC ID: UQY-HF1000 Back Company: Wavemark EG1106-1 FCC ID: UQY-HF1000 Front Company: Wavemark EG1106-1 FCC ID: UQY-HF1000 Left side Company: Wavemark EG1106-1 FCC ID: UQY-HF1000 Right side

External Photos

Company: Wavemark EG1106-1 FCC ID: UQY-HF1000 Showing grounding of BNC antenna cable using the Cu tape to the chassis Company: Wavemark EG1106-1 FCC ID: UQY-HF1000 Company: Wavemark EG1106-1 FCC ID: UQY-HF1000 Showing foil over the PC Company: Wavemark EG1106-1 FCC ID: UQY-HF1000 Showing position of ferrites on cables Company: Wavemark EG1106-1 FCC ID: UQY-HF1000

ID Label/Location Info

Product Performance and Suitability All of the descriptive information, the typical performance data, and recommendations for the use of FLEXcon products shall be used only as a guide and do not reflect the specification or specification range for any particular property of the product. Furnishing such information is merely an attempt to assist you after you have indicated your contemplated use and shall in no event constitute a warranty of any kind by FLEXcon. All purchasers of FLEXcon products shall be responsible for independently determining the suitability of the material for the purpose for which it is purchased. No distributor, salesman, or representative of FLEXcon is authorized to give any warranty, guaranty, or make any representation in addition or contrary to the above. ________________________________________________________________________________________________________________________________________________________________________________________ FLEXcon, 1 FLEXcon INDUSTRIAL PARK, SPENCER, MA 01562-2642 PHONE 508 885-8200 FAX 508 885-8400 Providing Solutions in Pressure Sensitive Films ________________________________________________________________________________________________________________________________________________________________________________________ Product Construction Sheet FLEXmount® V-23 LAMINATING ADHESIVE GENERAL DESCRIPTION: This is a 2.0 mil (51 micron) laminating permanent pressure sensitive acrylic adhesive. NOTE: For all testing, adhesive was laminated to 2.0 mil (51 micron) clear polyester (PM 200 CLEAR) film. ----------------------------------------------------------------------------------------------------- PRODUCT DATA VALUE TEST METHOD ----------------------------------------------------------------------------------------------------- PHYSICAL PROPERTIES Thickness Adhesive: 1.9-2.1 (48-53) +/- 0.1 (3) ASTM D 3652 mil (micron) ----------------------------------------------------------------------------------------------------- ADHESION PROPERTIES** Average Adhesion from oz/in (N/m) Stainless Steel 61 (671) ASTM D 903 (Modified for Acrylic 73 (803) 72 hr dwell time) Glass 69 (759) Polypropylene 16 (176) Expected Shear 100 + ASTM D 3654 Method A (1 hr (hours) dwell, 1 sq. in, 4 lb. load) Tack (gm) 770 ASTM D 2979 ** For guidance only, not to be used for setting specifications. Due to the custom nature of this product, the data presented are based on three or less production runs. ----------------------------------------------------------------------------------------------------- EXPECTED EXTERIOR LIFE Depends on substrates, adhesive is suitable for outdoor use ----------------------------------------------------------------------------------------------------- SERVICE TEMPERATURE -40°F to 302°F (-40°C to 150°C) ----------------------------------------------------------------------------------------------------- MINIMUM APPLICATION TEMPERATURE 50°F (10°C) ----------------------------------------------------------------------------------------------------- STORAGE STABILITY Two years stored at 70°F (21°C) and 50% RH ----------------------------------------------------------------------------------------------------- * FLEXmount is a registered trademark of FLEXcon Company, Inc. 11/02/2006

Internal Photos

Company: Wavemark FCC ID: UQY-HF1000 Company: Wavemark FCC ID: UQY-HF1000

Test Report

Curtis-Straus LLC is accredited to ISO/IEC 17025 by A2LA for the specific scope of accreditation under Certificate Number 1627-01. This report may contain data which is not covered by the A2LA accreditation. See our scope of accreditation at the end of this test report. Any opinions or interpretations expressed in this report are outside the scope of our A2LA accreditation as A2LA only accredits testing. ____________________________________________________________ Curtis-Straus • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 page 1 of 22 Test Report Report No EG1106-1 Client Wavemark Richard Desmarais Address 80 Central ST, Suite 300 Boxborough, MA 01719 Phone 978-264-6601 Items tested HF 1000 Standards FCC Part 15 Section 15.225 FCC ID UQY-HF1000 FRN 0013630066 Test Dates October 16 through 18, 2006 Results As detailed within this report Prepared by Mairaj Hussain – Test Engineer Authorized by Michael Buchholz – EMC Manager Issue Date 12/14/06 Conditions of Issue This Test Report is issued subject to the conditions stated in the ‘Conditions of Testing’ section on page 3 of this report. Test Report for Wavemark • Report No. EG1106-1 December 1, 2006 ______________________________________________________________________ ____________________________________________________________ Curtis-Straus • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 page 2 of 22 Contents Contents .................................................................................................................................... 2 Summary ................................................................................................................................... 3 Product Tested - Configuration Documentation ........................................................................ 3 Compliance Statement .............................................................................................................. 3 Modifications Required for Compliance..................................................................................... 3 Test Results .............................................................................................................................. 3 Section 15.225(a) .................................................................................................................. 3 Section 15.225(b)(c) .............................................................................................................. 3 Section 15.225(d) .................................................................................................................. 3 Section 15.207....................................................................................................................... 3 Test Equipment Used ................................................................................................................ 3 Jurisdictional Labeling and Required Instruction Manual Inserts .............................................. 3 CE Marking - European Union (EU) ...................................................................................... 3 Sample Declaration of Conformity ......................................................................................... 3 FCC Requirements ................................................................................................................3 Conditions Of Testing ................................................................................................................ 3 A2LA Accreditation.................................................................................................................... 3 Form Final Report REV 10-18-06 (DW) Test Report for Wavemark • Report No. EG1106-1 December 1, 2006 ______________________________________________________________________ Release Control Record Issue No. Reason for change Date Issued 1 Ori ginal Release December 1, 2006 _____________________________________________________________ Curtis-Straus • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 page 3 of 22 Summary On October 16 through 18 of 2006 we tested the HF 1000 for compliance with the following requirements: EMC Emissions: • FCC 47 CFR Part 15.225 Registration numbers for all open area test sites can be found in the Test Equipment Used Section starting on page 3. We found that the product met the above requirements with modification (see Modifications Required for Compliance section on page 3). This report is an application in pursuit of a FCC grant for the HF1000 with FCC ID: UQY- HF1000 operating under 47CFR 15.225. The product was tested using the methods outlined in ANSI C63.4 (2003). The radio module used in the HF1000 was previously tested under FCC ID: PJMMR101-PR101.The manufacturer intends to use the following new antenna with the product. RFID Antenna “I” Detailed schematic of the antenna board is attached as an exhibit with this report. Fundamental was measured with a loop antenna at a distance of 30m from the product. Harmonics and spurious emissions were measured at 3m distance from the product. The EUT antennas could not be maximized separately. The EUT was only tested in floor standing orientation on a rotating turn table. All readings are peak unless otherwise specified on the respective table. Temperature and voltage variation tests were not performed on the radio sample because Wavemark has not made any changes to the original radio. Data presented in this report is from the radio’s original testing. Richard Desmarais from Wavemark was present during the testing. The test sample was received in good condition. Test Report for Wavemark • Report No. EG1106-1 December 1, 2006 ______________________________________________________________________ _____________________________________________________________ Curtis-Straus • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 page 4 of 22 Product Tested - Confi…

Text truncated - open the document above for the full version.

Test Report

Company: Wavemark FCC ID: UQY-HF1000 Data Taken from original radio module test report with FCC ID: PJMMR101-PR101 Carrier Frequency Stability Company: Wavemark FCC ID: UQY-HF1000 Carrier Frequency Stability with Temperature Company: Wavemark FCC ID: UQY-HF1000 Carrier Frequency Stability vs Voltage Company: Wavemark FCC ID: UQY-HF1000

Test Setup Photos

Company: Wavemark G1106 FCC ID: UQY-HF1000 EMI Radiated Company: Wavemark G1106 FCC ID: UQY-HF1000 EMI Radiated Company: Wavemark G1106 FCC ID: UQY-HF1000 EMI Conducted on AC Power Company: Wavemark G1106 FCC ID: UQY-HF1000 EMI Conducted on AC Power Company: Wavemark G1106 FCC ID: UQY-HF1000 EMI Conducted on AC Power

Contact Information

Applicant

Richard Leitermann(Senior Director, HW Engineering)
[email protected]978-431-1633Fax: 978-431-1601

Test Firm

BUREAU VERITAS CONSUMER PRODUCTS SERVICES, INC.Ozgur Ozturk
[email protected]978-486-8880

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term
Grant Notes
This device must be professionally installed.

Other Applications from WaveMark, Inc.

RFID/Barcode Reader - FCC ID UQY-SW1500 - WaveMark, Inc.
UQY-SW1500

RFID/Barcode Reader

Sep 16, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
RFID Module - FCC ID UQY-PROX1 - WaveMark, Inc.
UQY-PROX1

RFID Module

Jan 12, 2010

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter