USQ3758Electric Toothbrush with Bluetooth LE

Braun GmbH

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 02, 2020
Application Purpose
Original Equipment
Date of Application
Jan 01, 2020
Equipment Note
Electric Toothbrush with Bluetooth LE
Frequency Range
2402.00000000 - 2480.00000000
Company
Braun GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

ID Label/Location Info

↗

Internal Photos

RF Exposure Info

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 HIGHLY RESTRICTED MC M7-9 UI – Sonos Use Instructions NA region English Master comments Translation required in: Spanish, French 2 iO Commercial name n/a www.oralb.com www.oralb.ca www.braun.com www.service.braun.com websites n/a Braun GmbH Frankfurter Strasse 145 61476 Kronberg Germany/Alemania/Allemagne Legal manufacturer n/a Charger Type 3768 Handle Type 3758 Travel Case Type 3759 Power Cord Type 492-xxxx Type numbers 90791650/XI-19 EN/E/F PMP#, current date, languages (2D code) n/a Description 1 Brush head 2 Brush head identification symbol 3 Smart Pressure Sensor 4 Interactive Display 5 Handle 6 Charger 7 On/off button 8 Mode button 9 Interactive Display features 10 «Daily Clean» mode 11 «Sensitive» mode 12 «Gum Care» mode 13 «Whitening» mode 14 «Intense Clean» mode 15 «Super Sensitive» mode 16 «Tongue Clean» mode 17 Settings menu 18 Settings menu features 19 Manage Bluetooth® settings 3 20 Select/Change color of Smart Pressure Sensor 21 Select/Change language 22 Perform factory reset 23 Feedback features 24 Timer 25 Battery status 26 Exchange reminder 27 Brush feedback Accessories and features: a Smart Pressure Sensor features b Customize color of Smart Pressure Sensor via Oral-B App c Brush head «Ultimate Clean» d Brush head «Gentle Care» e Brush head holder with cap f Brush head holder stand g Travel case h Charging travel case h1 Charging light h2 Power cord (power supply) i Download Oral-B App and connect to Bluetooth® (see back page) Note: Content may vary based on the model purchased. IMPORTANT SAFEGUARDS When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING added Dec 11th DANGER In order to reduce the risk of electrocution: 1. Do not use while bathing. 2. Do not place or store the charger, power cord or charging travel case where it can fall or be pulled into a tub or sink. 3. Do not place the charger, power cord or charging travel case in water or other liquid. 4 4. Do not reach for a charger, power cord or charging travel case that has fallen into water. Unplug immediately. WARNING To reduce the risk of burns, electrocution, fire or injury: 1. Close supervision is necessary when this product is used by, on, or near children or persons with disabilities. 2. Use this product only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer. Only use the charger provided with your appliance. 3. Keep cord away from heated surfaces. 4. Never drop the appliance or insert any object into any opening of the appliance. 5. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged or if it has been dropped into water. If any of these occur, please contact a service center and return the product for examination and repair. 6. Do not use on self when drowsy or on another who is drowsy or sleeping. 7. Do not use outdoors or operate where aerosol (spray) products are being used or where oxygen is being administered. IMPORTANT 1. Periodically check the entire product/cords/accessories for damage. A damaged or non-functioning unit should no longer be used. If the product/cords/accessories are damaged, take it to an Oral-B Service Center. 2. Do not touch the power plug with wet hands. This can cause an electric shock. 3. When unplugging, always pull the power plug instead of the cord. Avoid sharp bending, jamming or squeezing of the cord. Never insert any object into any opening of the appliance. 4. Do not modify or repair the product. This may cause fire, electric shock or injury. Consult your dealer for repairs or contact an Oral-B Service Center. 5. This appliance contains batteries that are non-replaceable. The appliance has no user serviceable parts. Do not open and disassemble device except when disposing of the battery. Follow handling and disposal instructions of the battery/ device described in this manual. 6. Do not use on children under age 3. 7. This toothbrush is a personal care device and is not intended for use on multiple patients in a dental practice or institution. For hygienic reasons we recommend the use of individual brush handles and brush heads for each family member. 8. Only use the charger and/or special cord set (power supply) with integrated Safety Extra Low Voltage power supply provided with your appliance. Do not exchange or tamper with any part of it, otherwise there is risk of an electric shock. If charger /charging travel case is marked with 492-xxxx, only use Braun/Oral-B special cord set (power supply) with this identification. 9. Small parts may come off, keep out of reach of children. 5 CAUTION To avoid brush head breakage which may generate a small parts choking hazard or damage teeth: • Prior to each use, ensure the brush head fits well. Discontinue use of the toothbrush, if brush head no longer fits properly. Never use without a brush head. • If the toothbrush handle is dropped, the brush head should be replaced before the next use even if no damage is visible • Replace brush head every 3 months or sooner if brush head becomes worn. • Clean brush head properly after each use (see «Cleaning recommendations» paragraph). Proper cleaning ensures the safe use and functional life of the toothbrush. If you are undergoing treatment for any oral care condition, consult your dental professional prior to use. SAVE THESE INSTRUCTIONS Important Information • This toothbrush, charger and pouch (accessory) contain NdFeB magnets and generate magnetic fields. If you use a medical device or have an implanted medical device, consult with the medical device manufacturer or a physician, if you have questions about safely using your Oral-B iO toothbrush. • Your Oral-B toothbrush can be used with your smartphone (find details under «Connecting your toothbrush to your Smartphone»). To avoid electromagnetic interference and/or compatib…

Text truncated - open the document above for the full version.

Cover Letter(s)

Sitz der Gesellschaft: Kronberg/Ts., Registergericht: Königstein/Ts. HRB 8036 Geschäftsführer: Janis Bauer, Bettina Buschhoff, Franz-Olaf Kallerhoff, Stefan Schamberg Citigroup Global Markets SWIFT CITIDEFF EUR : Kto. Nr. 211 625 023,IBAN DE18 5021 0900 0211 625023 SWIFT CITIGB2L USD : Kto. Nr. 138 61 074, IBAN GB46 CITI 1850 0813 8610 74 Braun GmbH Postfach 11 20 61466 Kronberg Braun GmbH Frankfurter Straße 145 61476 Kronberg im Taunus Telefon (0 61 73) 30-0 Telefax (0 61 73) 30-28 75 Internet www.braun.com Federal Communications Commission Martin Möesbauer 7435 Oakland Mills Road GPS Columbia MD 21046 06173 2243 [email protected] Jun, 04. 2019 Subject: Request for Confidentiality FCC ID: USQ3758 To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR §§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. Schematic Diagram Block Diagram Theory of Operation Antenna Sepecification Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short-term confidentiality request on the following attachments until 180 days from the date of grant. External Photos Internal Photos Test Setup Photos User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Seite 2/2 BF-0042WO00-07/04 Best Regards i.A. Martin Moesbauer Global Product Stewardship Procter&Gamble, Kronberg June, 4th. 2019

Cover Letter(s)

BRAUA Procter & Gamble Manufacturing GmbH Frankfurter Strasse 145 61476 Kronberg rn Taunus Telephone +49 61 73 30-0 Telefax +49 61 73 30-28 75 Internet www.braun.com Von: Martin Mösbauer Abt.: GPS Tel.: 06173 30-2243 E-mail: moesbauer.m©pg.com Datum: 2019-05-02 I, the undersigned, hereby authorize UL Verification Services Inc. to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by UL Verification Services Inc. on our behalf shall have the same effect as acts ofour own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 ofthe Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing UL Verification Services Inc. as our representative, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect ofthe scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; Sitz der Gesellschaft: Schwalbach/Ts. Registergericht: Königstein!Ts. HRB 5465 Vorsitzender des Aufsichtsrats: Heinz-Joachim Schuitner Geschäftsführer: Janis Bauer, Bettina Buschhoff, Gabriele Hässig, Franz-Olaf Kallerhoff, Stefan Schamberg, Astrid Teckentrup, Matthias Weber P&G Service GmbH Postfach 1120 61446 Kronberg Federal Communications Commission Equipment Authorization branch 7435 Oakland Mills Road Columbia, MD 21046 To whom it may concern: citigroup Global Markets Deutschland AG & co. KGaA, Frankfurt/Main BLZ 502 109 00, SWIFT CITIDEFF EUR: Kto. Nr. 211 625 023,IBAN DE18 5021 0900 0211 625023 BLZ 185 008 SWIFT CITIGB2L USD : Kto. Nr. 1386 1074, IBAN GB46 CITI 1850 0813 8610 74 BF-00042W000-01/1 5 BRAUA Page 2/2 f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, /// ‘ //A LA. Martin Mösbauer Global Product Stewardship Procter & Gamble, Kronberg 201 9-03-07 REMARK: I . This authorization letter will be sent along with your application when filing with UL Verification Services Inc. 2. Please follow the format and type it on company letterhead and send original to us. 3. Authorized signature must be in agreement with grantee code contact in FCC database and Industry Canada contact information. BF-00042W000-04/09

ID Label/Location Info

Project: Drawn Released No:Sheet: Process: Colour: Article:Scale: Tolerance: Risk Classification: RemarksIndexDateName HZ ILST-000177071 of 1 2 : 1 ± 0,3 n/aLaser Marking OP020 OP020 Handle Typeplate MN/NA incl. Gen 00113.03.2019Couturier13.03.2019Couturier P&G RESTRICTED Copyright by Braun GmbH Kronberg Production Code (ZXYWWDhhmm): Meaning Example Z Final Assembly Line A - FA Identification tbd tbd X Brush Type H = initial Version of OP020 Identification Y Year (last digit) 9 = 2019 WW Calender Week D Day of week 1 = Monday 7 = Sunday hh Hours mm Minutes Registration numbers only placeholders! see ECN00225.06.2019 Rieger

Test Report

NVLAP Lab code: 200065-0 CERTIFICATION TEST REPORT Report Number. : 12751212-E4V1 Applicant : Braun GMBH T-QTA FRANKFURTER STRASSE 145 KRONBERG TS, D-61476 DE Model : 3758 FCC ID : USQ3758 IC : 6856A-3758 EUT Description : ELECTRIC TOOTHBRUSH WITH BLUETOOTH LE Test Standard(s) : FCC 47 CFR PART 15 SUBPART C ISED RSS-247 ISSUE 2 ISED RSS-GEN ISSUE 5 Date Of Issue: October 14, 2019 Prepared by: UL Verification Services Inc. 47173 Benicia Street Fremont, CA 94538 U.S.A. TEL: (510) 319-4000 FAX: (510) 661-0888 REPORT NO: 12751212-E1V1 DATE: 10/14/2019 FCC ID: USQ3758 IC: 6856A-3758 Page 2 of 50 UL VERIFICATION SERVICES INC. 47173 Benicia Street, Fremont, CA 94538; USA TEL:(510) 319-4000 FAX:(510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. REPORT REVISION HISTORY Rev. Issue Date Revisions Revised By -- 10/14/2019 Initial Issue -- REPORT NO: 12751212-E1V1 DATE: 10/14/2019 FCC ID: USQ3758 IC: 6856A-3758 Page 3 of 50 UL VERIFICATION SERVICES INC. 47173 Benicia Street, Fremont, CA 94538; USA TEL:(510) 319-4000 FAX:(510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. TABLE OF CONTENTS REPORT REVISION HISTORY ................................................................................................. 2 TABLE OF CONTENTS ............................................................................................................ 3 1. ATTESTATION OF TEST RESULTS ................................................................................. 5 2. TEST METHODOLOGY ..................................................................................................... 7 3. FACILITIES AND ACCREDITATION ................................................................................. 7 4. CALIBRATION AND UNCERTAINTY ................................................................................ 8 4.1. MEASURING INSTRUMENT CALIBRATION .............................................................. 8 4.2. SAMPLE CALCULATION ............................................................................................ 8 4.3. MEASUREMENT UNCERTAINTY ............................................................................... 8 5. EQUIPMENT UNDER TEST ............................................................................................... 9 5.1. EUT DESCRIPTION .................................................................................................... 9 5.2. MAXIMUM OUTPUT POWER...................................................................................... 9 5.3. DESCRIPTION OF AVAILABLE ANTENNAS .............................................................. 9 5.4. SOFTWARE AND FIRMWARE .................................................................................... 9 5.5. WORST-CASE CONFIGURATION AND MODE .......................................................... 9 5.6. DESCRIPTION OF TEST SETUP ...............................................................................10 6. MEASUREMENT METHOD...............................................................................................14 7. TEST AND MEASUREMENT EQUIPMENT ......................................................................15 8. ANTENNA PORT TEST RESULTS (BLE 1Mbps) ............................................................16 8.1. ON TIME AND DUTY CYCLE .....................................................................................16 8.2. 99% BANDWIDTH ......................................................................................................18 8.3. 6 dB BANDWIDTH ......................................................................................................20 8.4. OUTPUT POWER.......................................................................................................22 8.5. AVERAGE POWER ....................................................................................................24 8.6. POWER SPECTRAL DENSITY ..................................................................................26 8.7. CONDUCTED SPURIOUS EMISSIONS .....................................................................28 9. RADIATED TEST RESULTS (BLE 1 Mbps) .....................................................................30 9.1. LIMITS AND PROCEDURE ........................................................................................30 9.2. TRANSMITTER ABOVE 1 GHz ..................................................................................31 9.3. WORST CASE BELOW 1 GHZ ...................................................................................41 9.4. WORST CASE 18-26 GHZ .........................................................................................43 REPORT NO: 12751212-E1V1 DATE: 10/14/2019 FCC ID: USQ3758 IC: 6856A-3758 Page 4 of 50 UL VERIFICATION SERVICES INC. 47173 Benicia Street, Fremont, CA 94538; USA TEL:(510) 319-4000 FAX:(510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. 10. AC POWER LINE CONDUCTED EMISSIONS (BLE 1 Mbps) .......................................45 11. SETUP PHOTOS ...........................................................................................................48 REPORT NO: 12751212-E1V1 DATE: 10/14/2019 FCC ID: USQ3758 IC: 6856A-3758 Page 5 of 50 UL VERIFICATION SERVICES INC. 47173 Benicia Street, Fremont, CA 94538; USA TEL:(510) 319-4000 FAX:(510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. 1. ATTESTATION OF TEST RESULTS COMPANY NAME: BRAUN GMBH T-QTA FRANKFURTER STRASSE 145 KRONBERG TS, D-61476 DE EUT DESCRIPTION: Electric Toothbrush with BLE MODEL: 3758 SERIAL NUMBER: W690(Radiated Sample), W694(Conducted Sample), D80192102474 (Wireless Travel Case Charger) DATE TESTED: JANUARY 14 – JUNE 4, 2019 APPLICABLE STAN…

Text truncated - open the document above for the full version.

Test Setup Photos

REPORT NO: 12751212-E1V1 DATE: 10/14/2019 FCC ID: USQ3758 IC: 6856A-3758 Page 48 of 50 UL VERIFICATION SERVICES INC. 47173 Benicia Street, Fremont, CA 94538; USA TEL:(510) 319-4000 FAX:(510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. 11. SETUP PHOTOS ANTENNA PORT CONDUCTED RF MEASUREMENT SETUP FRONT PHOTO AC MAINS LINE CONDUCTED EMISSIONS FRONT PHOTO (AC/DC ADAPTER) BACK PHOTO (AC/DC ADAPTER) REPORT NO: 12751212-E1V1 DATE: 10/14/2019 FCC ID: USQ3758 IC: 6856A-3758 Page 49 of 50 UL VERIFICATION SERVICES INC. 47173 Benicia Street, Fremont, CA 94538; USA TEL:(510) 319-4000 FAX:(510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. 3 METER RADIATED SPURIOUS EMISSIONS BELOW 30MHz FRONT PHOTO BACK PHOTO 3 METER RADIATED SPURIOUS EMISSIONS 30MHZ TO 1GHZ FRONT PHOTO BACK PHOTO 3 METER RADIATED SPURIOUS EMISSIONS 1GHZ TO 18GHz FRONT PHOTO BACK PHOTO REPORT NO: 12751212-E1V1 DATE: 10/14/2019 FCC ID: USQ3758 IC: 6856A-3758 Page 50 of 50 UL VERIFICATION SERVICES INC. 47173 Benicia Street, Fremont, CA 94538; USA TEL:(510) 319-4000 FAX:(510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. RADIATED RF MEASUREMENT FOR PORTABLE CONFIGURATION X-AXIS FRONT PHOTO Y-AXIS FRONT PHOTO Z-AXIS FRONT PHOTO END OF TEST REPORT

Contact Information

Applicant

Domenik Schulenberg(Compliance Manager)
[email protected]0049-6173-30-1437Fax: 00496173301425

Test Firm

UL Verification Services Inc. (formerly UL CCS)Jay Kogoma
[email protected]510-319-4135Fax: 000-000-0000

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.10 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Braun GmbH

Power Toothbrush Charger - FCC ID USQ3786 - Braun GmbH
USQ3786

Power Toothbrush Charger

Feb 19, 2023

Equipment Class

DTS - Digital Transmission System
Electric Toothbrush Charger - FCC ID USQ3768 - Braun GmbH
USQ3768

Electric Toothbrush Charger

Jan 05, 2020

Equipment Class

8CC - Part 18 Consumer Device
Electric Toothbrush with Wireless Display - FCC ID USQ3764 - Braun GmbH
USQ3764

Electric Toothbrush with Wireless Display

Jun 08, 2014

Equipment Class

DTS - Digital Transmission System
Electric Toothbrush with wireless display - FCC ID USQ3762 - Braun GmbH
USQ3762

Electric Toothbrush with wireless display

Apr 20, 2011

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Electric Toothbrush - FCC ID USQ3738 - Braun GmbH
USQ3738

Electric Toothbrush

May 02, 2007

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified