Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
PULSE915-LRWTerminal UserManual LoRaWANTerminalSeries Version2.1 Date:2020-09-11 www.friendcom.com PULSE915-LRW_User_Manual FCC Statement 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. To comply with RF exposure requirements, a minimum separation distance of 20cm must be maintained between the user’s body and the device, including the antenna. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Friendcom has always been committed to technological innovation. Our aim is to provide customers with timely and comprehensive service. For any assistance, please contact our Shenzhen headquarters: FRIENDCOM TECHNOLOGY CO., LTD. 7th Floor, 17 Building, Guangqian Industrial Park, Xili Town, Nanshan District, Shenzhen, 518055, China Tel: +86-755-86026600 +86-755- 23230320 Fax: +86-755-86026300 For technical support, or to report documentation errors, please visit: http://www.friendcom.com Or email to: [email protected] Page 1 / 23 PULSE915-LRW_User_Manual Page 2 / 23 NOTICE Informationinthisdocumenthasbeencarefullyreviewedandisconsideredtobeaccurate. However,Friendcomassumesnoliabilityresultingfromanyinaccuraciesoromissionsin thisdocument,orfromuseoftheinformationobtainedherein.Friendcomreservestheright tomakechangestoanyproductsdescribedhereinandreservestherighttorevisethis documentandtomakechangesfromtimetotimeincontenthereofwithnoobligationto notifyanypersonofrevisionsorchanges.Friendcomdoesnotassumeanyliabilityarising outoftheapplicationoruseofanyproductdescribedherein. COPYRIGHTS ThismanualandFriendcomproductsdescribedhereinmayincludeordescribecopyrighted FriendcommaterialandareconsideredtechnicalproprietaryofFriendcomCO.,LTD. Accordingly,anycopyrightedmaterialofFriendcomanditslicensorscontainedhereinorin Friendcomproductsdescribedinthismanualmaynotbecopied,reproduced,distributed, mergedormodifiedinanymannerwithouttheexpresswrittenpermissionofFriendcom. TRADEMARKS andFriendcomlogoareregisteredTrademarks.Allotherproductor servicenameswhicharementionedinthisdocumentarethepropertyoftheirrespective owners. Copyright©FriendcomCommunications2020.Allrightsreserved. AboutThisDocument Scope ScopeofthisdocumentistopresentfeaturesandapplicationofFriendcomwirelesspulse acquisitionterminalPULSE915-LRW Audience Thisdocumentisintendedfor systemengineers(SEs), applicationengineers, andtestengineers. PULSE915-LRW_User_Manual Page 3 / 23 Related Documents Friendcom_PULSE915-LRW_Terminal_Datasheet Friendcom_PULSE915-LRW_Configuration_User_Manual Conventions SymbolIndication This warning symbol means danger. You are in a situation that could cause fatal device damage or even bodily damage. Means reader be careful. In this situation, you might perform an action that could result in module or product damages. Means note or tips for readers to use the module. PULSE915-LRW_User_Manual Page 4 / 23 History IssueDateChange 1.02018-05Initialdraft 1.12019-06 UpdateInterfacedefinition AddedpulsewiringmethodofHallsensortype Updatetheformatofproactivedatareporting Addeddatashortframeformat Updatemagnetactivetimeandcorrespondingfunctions 1.22020-04 Updateproductdescription Addedfirmwareupgradecontent 2.02020-08 UpdatingnewLoRaWANmodule Updatingofcontents 2.12020-09 Updateproductwiredconnectiondescription. Updatethebandsupport. PULSE915-LRW_User_Manual Page 5 / 23 Content AboutThisDocument ........................................................................................................................................... 2 TableIndex ............................................................................................................................................................ 6 FigureIndex ........................................................................................................................................................... 7 1Introduction ....................................................................................................................................................... 8 2ProductConcept ................................................................................................................................................ 8 2.1GeneralDescription ................................................................................................................................ 8 2.2KeyFeatures ............................................................................................................................................ 8 2.3Specifications ........................................................................................................................................…
Text truncated - open the document above for the full version.
Report No: JYTSZB-R01-2100088 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2103003 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 29 of 36 8 EUT Constructional Details Report No: JYTSZB-R01-2100088 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2103003 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 30 of 36 Report No: JYTSZB-R01-2100088 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2103003 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 31 of 36
Report No: JYTSZB-R01-2100088 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2103003 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 32 of 36 Report No: JYTSZB-R01-2100088 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2103003 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 33 of 36 Report No: JYTSZB-R01-2100088 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2103003 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 34 of 36 Report No: JYTSZB-R01-2100088 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2103003 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 35 of 36 Report No: JYTSZB-R01-2100088 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2103003 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 36 of 36 ------End of report------
JianYan Testing Group Shenzhen Co., Ltd. Report No: JYTSZB-R12-2100303 Authorized Signature: Bruce Zhang Laboratory Manager This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the JYT product certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 1 Cover Page FCC REPORT Applicant: Shenzhen Friendcom Technology Development Co., Ltd. Address of Applicant: 5-6 Floor, Building 17, Guangqian Industrial Park, Xili, Nanshan District, Shenzhen, Guangdong Province, China Equipment Under Test (EUT) Product Name: Wireless Pulse Acquisition Module PULSE915-LRW Model No.: FC-714 Trade mark: Friendcom FCC ID: UU3FC-714 Applicable standards: FCC CFR Title 47 Part 15 Subpart B Date of sample receipt: 02 Mar., 2021 Date of Test: 03 Mar., to 01 May, 2021 Date of report issued: 12 May, 2021 Test Result: PASS *7 * In the configuration tested, the EUT complied with the standards specified above. Report No: JYTSZB-R12-2100303 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2103003 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 2 of 16 2 Version Version No. Date Description 00 12 May, 2021 Original Tested by: Date: 02 May, 2021 Test Engineer Reviewed by: Date: 12 May, 2021 Project Engineer Report No: JYTSZB-R12-2100303 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2103003 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 3 of 16 3 Contents Page 1 COVER PAGE ....................................................................................................................................................... 1 2 VERSION ............................................................................................................................................................... 2 3 CONTENTS ........................................................................................................................................................... 3 4 TEST SUMMARY .................................................................................................................................................. 4 5 GENERAL INFORMATION .................................................................................................................................. 5 5.1 CLIENT INFORMATION ...................................................................................................................................................... 5 5.2 GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................................... 5 5.3 TEST MODE .................................................................................................................................................................... 5 5.4 MEASUREMENT UNCERTAINTY ........................................................................................................................................... 5 5.5 DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................... 5 5.6 RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................... 5 5.7 DESCRIPTION OF CABLE USED ............................................................................................................................................ 5 5.8 ADDITIONS TO, DEVIATIONS, OR EXCLUSIONS FROM THE METHOD ............................................................................................. 6 5.9 LABORATORY FACILITY ...................................................................................................................................................... 6 5.10 LABORATORY LOCATION ............................................................................................................................................... 6 5.11 TEST INSTRUMENTS LIST ............................................................................................................................................... 7 6 TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8 6.1 CONDUCTED EMISSION ..................................................................................................................................................... 8 6.2 RADIATED EMISSION ........................................................................................................................................................ 9 7 TEST SETUP PHOTO ....................................................................................................................................…
Text truncated - open the document above for the full version.
Report No: JYTSZB-R12-2100303 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2103003 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 15 of 16 7 Test Setup Photo Radiated Emission Below 1GHz Above 1GHz Report No: JYTSZB-R12-2100303 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2103003 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 16 of 16 8 EUT Constructional Details Reference to the test report No.: JYTSZB-R01-2100088. ------End of report------
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

LoRaWAN wireless communication model
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
IDUV915-LRW Inductive Sensor Endpoint
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
LoRaWAN Module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
FC-302 Data Radio
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
UHF DATA RADIO
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter