Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FT 95 ENGLISH Non-contact Thermometer Instruction manual �����������������3 ESPAÑOL Termómetro sin contacto Manual de instrucciones �����28 FRANÇAIS Thermomètre sans contact Mode d’emploi ����������������������54 Distributed by/Distribuido por/ Distribué par : Beurer North America LP 1 Oakwood Boulevard, Suite 255 Hollywood, FL 33020, USA www.beurer.com Questions or Comments? Call our US-based customer service toll free at 1-800-536-0366� ¿Preguntas o comentarios? Llame a nuestro servicio al cliente en Estados Unidos gratis al teléfono 1-800-536-0366� Questions ou commentaires? Appelez gratuitement notre service clientèle situé aux États-Unis au 1-800-536-0366� 2 READ THIS MANUAL COMPLETELY AND CAREFULLY BEFORE USING THIS PRODUCT Keep this manual in a safe location for future reference LEA TODO ESTE MANUAL CON ATENCIÓN ANTES DE USAR ESTE PRODUCTO Conserve este manual en un lugar seguro para consultarlo en el futuro LISEZ CE MODE D’EMPLOI COMPLÈTEMENT ET ATTENTIVEMENT AVANT D’UTILISER CE PRODUIT Conservez ce manuel en lieu sûr pour y faire référence ultérieurement 3 SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE If the instruction manual is damaged or if you no longer have the instruction manual in your possession, please contact Beurer customer service� Please see warranty for service contact� ENGLISH Contents 1. Important safety notes ..................................4 2. Getting to Know your Instrument ..................9 3. Package Contents .......................................11 4. Parts and Controls .....................................12 5. To Set Up .....................................................14 6. To Use .........................................................15 7. Care, Maintenance and Disposal ..............20 8. Troubleshooting Guide ..............................21 9. Technical Specification..............................22 10. FCC Compliance Information ...................23 11. Warranty ....................................................24 4 Dear Valued Customer, Thank you for choosing one of our products. Our name stands for high-quality, thoroughly tested products for application in the areas of heating, weight management, blood pressure, body temperature, pulse, gentle therapy, massage, and beauty. Register your product today to receive further benefits: • added protection for your purchase • health and wellness tips • new product information • continual outstanding customer service and support. Visit www.registerbeurer.com or contact customer service at 1-800-536-0366. Please read these instructions for use carefully and keep them for later use. Make them accessible to other users and observe the information they contain. With kind regards, Your Beurer Team 1� Important safety notes Signs and symbols Whenever used, the following signs identify safety and property damage messages and designate a level of hazard or seriousness. READ THIS ENTIRE MANUAL INCLUDING THE SAFETY SECTION AND ALL INSTRUCTIONS AND WARNINGS COMPLETELY AND CAREFULLY BEFORE USING THIS PRODUCT� FOLLOW ALL SAFETY INSTRUCTIONS AND 5 WARNINGS TO AVOID HAZARDOUS SITUATIONS AND TO MAKE CORRECT USE OF THIS PRODUCT� This is the safety alert symbol. It alerts you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. CAUTION Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury. NOTICE Addresses practices not related to personal injury, such as product and/or property damage. Note Note on important information Type BF applied part Follow instructions for use Operating Permissible operating temperature and humidity 6 Storage/Transport Permissible storage temperature and humidity Serial number IP 22 Device protected against foreign objects ≥ 12.5 mm and against water dripping at an angle w Cross-reference with another section. CAUTION - To reduce the risk of personal injury or product/property damage: • This device is designed solely for non-commercial, household use in non-invasively measuring temperatures via an infrared sensor of the human body for persons of all ages, as well as detecting surface temperatures of objects and ambient temperatures of surrounding areas. Do not use for any other purpose. • This thermometer is a sensitive electronic device. Treat it carefully and do not expose it to any sharp impacts. • Do not expose the thermometer to direct sunlight. • Do not disassemble this unit. • The thermometer is NOT waterproof; keep away from water and other liquids. • After physical activity, a bath or spending time outdoors, wait approx. 30 minutes before you take a measurement on your forehead. • Before each use, ensure the sensor is undamaged; otherwise, contact customer service. 7 • The device needs to be in the room in which the measurement is taken for at least 30 minutes before use. • This device is not intended for commercial or clinical use. • Measure your temperature regularly to obtain your normal average temperature. If you suspect you have a fever, simply compare your normal average temperature with the temperature measured currently. • Do not self-diagnose or self-medicate on the basis of the measurements without consulting your doctor. In particular, do not start taking any new medication or change the type and/or dosage of any existing medication without prior approval. • Clean the thermometer after each use (see 7. Care and Maintenance). • The manufacturer is not liable for damage resulting from improper or careless use. • Children must not be allowed to use the device. Medical devices are not toys. • Do not touch the lens with your fingers. • Read these instructions for use carefully and keep them for later use. • Packaging materials are a deadly hazard for children and can cause suffocation. Remove all packaging materials immediately and keep them away from children at all times. NOTICE – To reduce the risk of product/property damage: • Taking your temperature provides …
Text truncated - open the document above for the full version.
Nemko Canada Inc 303 River Road Ottawa, Ontario, Canada K1V 1H2 Attn: Director of Certification (FCC ID: UV3-FT95-1) Authority to Act as Agent On our behalf, I appoint Chenz Ker (MRT Technology (Taiwan) Co., Ltd./ No.38 Fuxing 2 nd Road, Guishan Dist., Taoyuan City, Taiwan 33377). to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko Canada Inc, still resides with AViTA Corporation / 9F, No.78, Sec. 1,Kwang-Fu Road, San-Chung District, New Taipei City 241,Taiwan(R.O.C) Dated this 2022/10/13 Agency agreement expiration date: 2022/12/12 By: Henry Hsu Signature Printed Title: Engineer On behalf of : AViTA Corporation
October 13, 2022 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 REQUEST FOR CONFIDENTIALITY - FCC FCC ID: UV3-FT95-1 Pursuant to Sections 0.457(d) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request permanent confidential treatment of exhibits identified as such in the table below and request they are permanently withheld from public review based on the documents containing trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. We also request short-term confidentiality on certain exhibits until the intended date of marketing as outlined below. We request the exhibits be withheld from public view for a period of insert number of days (cannot exceed 180 days) days. We attest marketing of the product will only commence after the period of short-term confidentiality expires, or if marketing is to commence before the requested number of days listed above, the grantee will inform Nemko to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. Exhibit Type of Confidentiality Requested Block Diagrams ☒ Permanent ☐ Short Term External Photos ------------------ ☐ Short Term Internal Photos ☐ Permanent* ☐ Short Term Operation Description ☒ Permanent ☐ Short Term Parts List & Placement/BOM ☐ Permanent ☐ Short Term Tune-Up Procedure ☐ Permanent ☐ Short Term Schematic Diagrams ☒ Permanent ☐ Short Term Test Setup Photos ------------------ ☐ Short Term User’s Manual ☐ Permanent* ☐ Short Term The asterisked items (*) require further information to be provided in this justification letter before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. Note: any documents held under the Short-Term confidentiality will automatically become public after the requested time if an appropriate extension request has not been received. Any exhibits (i.e., schematic diagrams) that may have already been requested to have “Permanent” confidentiality as shown above need not be repeated under Short-Term confidentiality request. Sincerely, Signed: Printed name: Henry Hsu Title: Engineer Company Name: AViTA Corporation
Report No.: 2205TW8602-U2~U3 Product: Non-Contact Thermometer Brand Name: Beurer Model Number: FT 95 1 of 3 External Photograph (1) EUT Photo (2) EUT Photo Report No.: 2205TW8602-U2~U3 2 of 3 (3) EUT Photo (4) EUT Photo Report No.: 2205TW8602-U2~U3 3 of 3 (5) EUT Photo (6) EUT Photo
Label Label location
Report No.: 2205TW8602-U2~U3 Product: Non-Contact Thermometer Brand Name: Beurer Model Number: FT 95 1 of 4 Internal Photograph (1) EUT Photo (2) EUT Photo Report No.: 2205TW8602-U2~U3 2 of 4 (3) EUT Photo (4) EUT Photo Report No.: 2205TW8602-U2~U3 3 of 4 (5) EUT Photo (6) EUT Photo Report No.: 2205TW8602-U2~U3 4 of 4 (7) EUT Photo
MRT Technology (Taiwan) Co., Ltd Report No.: 2205TW8602-U3 Phone: +886-3-3288388 Report Version: 1.0 Fax: +886-3-3288918 Issue Date: 2022-09-20 Web: www.mrt-cert.com FCC ID: UV3-FT95-1 Page Number: 1 of 5 RF Exposure Evaluation Declaration FCC ID: UV3-FT95-1 APPLICANT: AViTA Corporation Application Type: Certification Product: Non-Contact Thermometer Model No.: FT 95 Brand Name: Beurer FCC Rule Part(s): Part 2.1093 (Portable) Test Date: May 20 ,2022 Reviewed By : ( Paddy Chen ) Approved By : ( Chenz Ker ) The test results relate only to the samples tested. This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report. Test results reported herein relate only to the item(s) tested. The test report shall not be reproduced except in full without the written approval of MRT Technology (Taiwan) Co., Ltd. Report No.: 2205TW8602-U3 FCC ID: UV3-FT95-1 Page Number: 2 of 5 Revision History Report No. Version Description Issue Date Note 2205TW8602-U3 1.0 Original Report 2022-09-20 Report No.: 2205TW8602-U3 FCC ID: UV3-FT95-1 Page Number: 3 of 5 1. PRODUCT INFORMATION 1.1. Equipment Description 1.2. Antenna Description No. Manufacturer Part No. Antenna Type Peak Gain 1 N/A N/A PCB -2.7dBi Product Name Non-Contact Thermometer Model No. FT 95 Brand Name Beurer Bluetooth Specification V5.0 LE Operating Frequency 2402~2480MHz Modulation Type GFSK Report No.: 2205TW8602-U3 FCC ID: UV3-FT95-1 Page Number: 4 of 5 2. MAXIMUM PERMISSIBLE EXPOSURE (MPE) 2.1. FCC Limits According to FCC KDB 447498 Section 4.3 - General SAR test exclusion guidance For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where 1. f(GHz) is the RF channel transmit frequency in GHz 2. Power and distance are rounded to the nearest mW and mm before calculation 3. The result is rounded to one decimal place for comparison 4.The values 3.0 and 7.5 are referred to as numeric thresholds in step b) below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm, and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 4.1 f) is applied to determine SAR test exclusion. Report No.: 2205TW8602-U3 FCC ID: UV3-FT95-1 Page Number: 5 of 5 2.2. Test Result Mode Frequency Band (MHz) Average Output Power (dBm) Output Power (mW) FCC Extremity SAR Test Exclusion Threshold (mW) Antenna Gain (dBi) EIRP (mW) BLE 2402~2480 -2.57 0.55 3.0 -2.7 -2.15 So, this device can complies the SAR test exclusion. The End
Report No.: 2205TW8602-U2~U3 Product: Non-Contact Thermometer Brand Name: Beurer Model Number: FT 95 1 of 3 Test Photograph Test Mode 1 Description: Front View of Conducted Emission Test Setup Test Mode 1 Description: Back View of Conducted Emission Test Setup Report No.: 2205TW8602-U2~U3 2 of 3 Test Mode: Mode 1 Description: Radiated Emission Test Setup for below 1GHz Test Mode: Mode 1 Description: Radiated Emission Test Setup for above 1GHz Report No.: 2205TW8602-U2~U3 3 of 3 Test Mode: Mode 1 Description: Conducted Emission Test Setup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 500.00 µW |

Touch Free Infrared Thermometer
Equipment Class
DTS - Digital Transmission System
Arm Type Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission System
Non-Contact Thermometer
Equipment Class
DTS - Digital Transmission System
Multifunctional thermometer
Equipment Class
DTS - Digital Transmission System
IR Thermometer
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter