Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
TOUCH FREE Infrared Thermometer NT66B EN MDSS GmbH Schiffgraben 41 30175 Hannover Germany AViTA Corporation 9F., No. 78, Sec. 1, Kwang Fu Rd., San Chung Dist., New Taipei City 24158, Taiwan, China China, AViTA(WUJIANG) INSTRUCTION MANUAL Please read this instruction manual carefully before using your forehead thermometer Contents Introduction .................................................................................................................... 1 Important Information before Use ........................................................................ 2 Product Identification ................................................................................................. 4 Description of LCD Display ....................................................................................... 5 Battery Installation ....................................................................................................... 6 Switching Between Fahrenheit or Celsius ............................................................ 7 Switching between 4 Kinds of Measuring Mode .............................................. 7 Tips for Measuring Human Temperature ............................................................ 8 Measuring Human Temperature ............................................................................. 8 Measuring Object/Liquid Temperature .............................................................. 10 Memory Function ....................................................................................................... 11 Cleaning and Disinfecting ....................................................................................... 12 Error Codes ................................................................................................................... 12 Troubleshooting .......................................................................................................... 13 Operating the Bluetooth function........................................................................ 15 Technical Specification ............................................................................................. 16 EMC Tables .................................................................................................................... 17 Federal communications commission interference statement ................. 19 Explanation of Symbols ............................................................................................ 20 1 Introduction Intended Use: Touch Free Infrared Thermometer is intended for home use and the intermittent measurement of human body forehead temperature in people of all ages. Features: 1. 2 in 1 thermometer: Human Body/Object 2. Fever Indication (Human Body Mode only) 3. °C/°F Switch-able Function 4. Multi-memory Recall 5. One-second Reading 6. Power Saving-Auto Power Off Auto power-off after idling to ensure battery life. 7. Warning indication "low battery" symbol, and “Lo"/ "Hi" symbol indicating out of measuring range. 8. Large LCD Display 9. Large Button Design 10. Economic design and convenience This is a “Non-contact” medical thermometer that enables temperature readings, designed for sanitary conditions, cleanliness, and convenience. Simply move the thermometer close to the subject's forehead or object at the distance indicated by the device. 11. Accurate and Reliable 12. User Friendly Due to our unique design of the measuring software, users don't need to have special skill to operate this device. 13. Instant Measurement By using our unique technology, users can get their precise body temperature instantly and accurate. 14. Handicapped persons and children need assistance by another person to use the device. 2 Important Information before Use When using this product, please be sure to follow all the notes listed below. Any action against these notices may cause injury or affect the accuracy. 1. Do not disassemble, repair, or remodel the thermometer. 2. Be sure to clean the thermometer lens each time after usage. 3. Avoid direct finger contact with the lens. 4. No modification of this equipment is allowed. 5. It is recommended that user may take 3 temperatures. If they are different, use the highest reading. 6. Do not expose the thermometer to extreme temperature, very high humidity, or direct sunlight. 7. Avoid extreme shock or dropping the device. 8. Before the measurement, patients and thermometer should stay in steady state room condition for at least 30 minutes. 9. Avoid measuring temperature in 30 minutes after exercise, bathing, or returning from outdoor. 10. To protect the environment, dispose of empty batteries at appropriate collection sites according to national or local regulations. 11. Please use the thermometer solely for its intended purpose. 12. There are no absolute body temperature standards. Keep reliable records of your personal temperature to serve as a reference for judging a fever. 13. Under any circumstances, the temperature taking result is ONLY for reference. Before taking any medical action, please consult your physician. 14. The thermometer is calibrated at the time of manufacture. If at any time you question the accuracy of temperature measurements, please contact an authorized distributor for sending calibration services, additional cost may apply for return shipping fee. 3 15. CAUTION: Please keep this device away from pets, pests, and children. 16. CAUTION: Please keep away from children and pets, because small parts may be inhaled or swallowed. 17. If any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the Member State in which the user is established. 18. If you would require any assistance during setting up, using or maintaining, please contact the manufacturer. 19. Avoid using the device near an operating cell phone or microwave oven. Contraindications: 1. Scarred or compromised tissues on measurement site. 2. P…
Text truncated - open the document above for the full version.
Doc nr. Certification Application Attestation Statements AViTA Corporation 9F, No.78, Sec.1, Kwang-Fu Rd, San-Chung District, New Taipei City 24158, Taiwan To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) AViTA Corporation certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. Additional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) AViTA Corporation certifies that, as of the date of the filing of this application, the applicant - is / - is not (3) identified on the Covered List as an entity producing “covered” equipment. Date: 2024/06/03 City: New Taipei Name (2) : Terry yang Function: Deputy Manager Telephone number: +886-2-85121347 Email address: [email protected] Signature: 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . (2): For FCC it must be the Grantee Code “owner” or the authorized agent. (3): double cllick on the appropriate box and select ‘’checked” then “OK”
Doc nr. U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) TO: Kiwa Nederland B.V. Wilmersdorf 50 7327 AC Apeldoorn Postbus 137 7300 AC Apeldoorn Netherlands ATTENTION: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company name: TianHeng Consulting, LLC FRN: 0033401258 Contact person name: Hualing Dong Street address: 392 Andover Street, Wilmington, MA 01887, United States Telephone number: +1 617-997-4010 Email address: [email protected] Signature: Date: June _13_, 2023 This letter is to confirm that we (“the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission- related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: AViTA Corporation Grantee Code: UV3 Contact person name: Terry yang Street address: 9F, No. 78, Sec. 1, Kwang-Fu Road, San-Chung District, New Taipei City 24158, Taiwan Telephone number: +886-2-85121568 Email address: [email protected] Signature: Date: June _13_, 2023 Hualing Dong, President
RF_160_05 Declaration of Authorisation Date of issue 02-01-2023 Declaration of Authorization We Name: AViTA Corporation Address: 9F, No.78, Sec.1, Kwang-Fu Rd, San-Chung District, City: New Taipei City Country: Taiwan Declare that: Name Representative of agent: Chenz Ker Agent Company name: MRT Technology (Taiwan) Co., Ltd Address: No. 38, Fuxing Second Rd., Guishan Dist., City: Taoyuan Country Taiwan is authorized to apply for Certification of the following product(s): Product description: Touch Free Infrared Thermometer FCC ID: UV3NTW-66B Type designation: NT66B Trademark: AViTA on our behalf. Date: 2024/06/03 Name: Terry yang Function: Deputy Manager Signature: .
FCC, Request for non-disclosure Date: 02-01-2022 RF_501, Issue 10 Company Name: AViTA Corporation Address: 9F, No.78, Sec.1, Kwang-Fu Rd, San-Chung District, City: New Taipei City Country: Taiwan To: Kiwa Netherlands B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: UV3NTW-66B Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Date: 06/03/2024 Name and signature of applicant: Terry yang Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should state in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Kiwa NL B.V. at least 7 days before date of actual marketing or before expiration of the STC period
Report No.: 2405TW8601-UE 1 of 4 External Photograph (1) EUT Photo (2) EUT Photo Report No.: 2405TW8601-UE 2 of 4 (3) EUT Photo (4) EUT Photo Report No.: 2405TW8601-UE 3 of 4 (5) EUT Photo (6) EUT Photo Report No.: 2405TW8601-UE 4 of 4 (7) EUT Photo (8) EUT Photo
Labels Information Model: NT66B Issue date: 2024-05-24 Label Information FCC ID UV3NTW-66B TOUCH FREE Infrared Thermometer NT66B AViTA Corporation YYMWWWXXXXX Battery: 2 x 1.5V LR03(AAA) alkaline
Report No.: 2405TW8601-UI 1 of 5 Internal Photograph (1) EUT Photo (2) EUT Photo Report No.: 2405TW8601-UI 2 of 5 (3) EUT Photo (4) EUT Photo Report No.: 2405TW8601-UI 3 of 5 (5) EUT Photo (6) EUT Photo Report No.: 2405TW8601-UI 4 of 5 (7) EUT Photo (8) EUT Photo Report No.: 2405TW8601-UI 5 of 5 (9) EUT Photo
MRT Technology (Taiwan) Co., Ltd Report No.: 2405TW8601-U3 Phone: +886-3-3288388 Report Version: 1.0 Fax: +886-3-3288918 Issue Date: 2024-06-03 Web: www.mrt-cert.com Page Number: 1 of 5 RF Exposure Evaluation Declaration FCC ID: UV3NTW-66B APPLICANT: AViTA Corporation Application Type: Certification Product: Touch Free Infrared Thermometer Model No.: NT66B Brand Name: AViTA FCC Rule Part(s): Part 2.1093 (Portable) Received Date: May 9, 2024 Reviewed By : ( Paddy Chen ) Approved By : ( Chenz Ker ) The test results relate only to the samples tested. This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report. Test results reported herein relate only to the item(s) tested. The test report shall not be reproduced except in full without the written approval of MRT Technology (Taiwan) Co., Ltd. Report No.: 2405TW8601-U3 Page Number: 2 of 5 Revision History Report No. Version Description Issue Date Note 2405TW8601-U3 1.0 Original Report 2024-06-03 Report No.: 2405TW8601-U3 Page Number: 3 of 5 1. PRODUCT INFORMATION 1.1. Equipment Description 1.2. Antenna Description No. Manufacturer Part No. Antenna Type Peak Gain 1 N/A KNC-001 PCB -3.19dBi Product Name Touch Free Infrared Thermometer Model No. NT66B Brand Name AViTA Bluetooth Specification V4.2 Operating Frequency 2402~2480MHz Modulation Type GFSK Report No.: 2405TW8601-U3 Page Number: 4 of 5 2. MAXIMUM PERMISSIBLE EXPOSURE (MPE) 2.1. FCC Limits According to FCC KDB 447498 Section 4.3 - General SAR test exclusion guidance For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where 1. f(GHz) is the RF channel transmit frequency in GHz 2. Power and distance are rounded to the nearest mW and mm before calculation 3. The result is rounded to one decimal place for comparison 4.The values 3.0 and 7.5 are referred to as numeric thresholds in step b) below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm, and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 4.1 f) is applied to determine SAR test exclusion. Report No.: 2405TW8601-U3 Page Number: 5 of 5 2.2. Test Result Mode Frequency Band (MHz) Output Power (dBm) Output Power (mW) FCC Extremity SAR Test Exclusion Threshold (mW) BLE 2402~2480 -5.59 0.28 3 So, this device can complies the SAR test exclusion. The End
Antenna Test Report Antenna Type: PCB Layout Antenna MAX. Gain: -3.19 dBi BTL INC. No.18, Ln. 171, Sec. 2, Jiuzong Rd., Neihu Dist., Taipei City 114, Taiwan. dĞƐƚ^ĞƚƵƉWŚŽƚŽ͗
MRT Technology (Taiwan) Co., Ltd Report No.: 2405TW8601-U2 Phone: +886-3-3288388 Report Version: 1.0 Fax: +886-3-3288918 Issue Date: 2024-06-03 Web: www.mrt-cert.com Page Number: 1 of 54 FCC ID : UV3NTW-66B APPLICANT : AViTA Corporation Application Type : Certification Product : Touch Free Infrared Thermometer Model No. : NT66B Brand Name : AViTA FCC Classification : (DTS) Digital Transmission System FCC Rule Part(s) : Part 15.247 Test Procedure(s) : ANSI C63.10-2013 Received Date : May 9, 2024 Test Date : May 22, 2024~May 28, 2024 MEASUREMENT REPORT Tested By : ( Kaunaz Lee ) Reviewed By : ( Paddy Chen ) Approved By : ( Chenz Ker) The test results only relate to the tested sample. This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in ANSI C63.10. Test results reported herein relate only to the item(s) tested. The test report shall not be reproduced except in full without the written approval of MRT Technology (Taiwan) Co., Ltd. Report No.: 2405TW8601-U2 Page Number: 2 of 54 Revision History Report No. Version Description Issue Date Note 2405TW8601-U2 1.0 Original Report 2024-06-03 Report No.: 2405TW8601-U2 Page Number: 3 of 54 CONTENTS Description Page 1. INTRODUCTION ..................................................................................................................... 6 1.1. Scope .................................................................................................................................... 6 1.2. MRT Test Location ................................................................................................................ 6 2. PRODUCT INFORMATION ..................................................................................................... 7 2.1. Equipment Description .......................................................................................................... 7 2.2. Product Specification Subjective to this Standard .................................................................. 7 2.3. Test Mode ............................................................................................................................. 7 2.4. Operation Frequency / Channel List ...................................................................................... 8 2.5. Test Configuration ................................................................................................................. 9 2.6. Test System Details .............................................................................................................. 9 2.7. Test Software ........................................................................................................................ 9 2.8. EMI Suppression Device(s)/Modifications ........................................................................... 10 2.9. Labeling Requirements ....................................................................................................... 10 3. DESCRIPTION of TEST ......................................................................................................... 11 3.1. Evaluation Procedure .......................................................................................................... 11 3.2. AC Line Conducted Emissions ............................................................................................ 11 3.3. Radiated Emissions ............................................................................................................ 12 4. ANTENNA REQUIREMENTS ................................................................................................ 13 5. TEST EQUIPMENT CALIBRATION DATE ............................................................................ 14 6. MEASUREMENT UNCERTAINTY ......................................................................................... 15 7. TEST RESULT ...................................................................................................................... 16 7.1. Summary ............................................................................................................................. 16 7.2. Occupied Bandwidth Measurement ..................................................................................... 17 7.2.1. Test Limit ......................................................................................................................... 17 7.2.2. Test Procedure used ....................................................................................................... 17 7.2.3. Test Setting ..................................................................................................................... 17 7.2.4. Test Setup ....................................................................................................................... 17 7.2.5. Test Result ...................................................................................................................... 18 7.3. Output Power Measurement ................................................................................................ 20 7.3.1. Test Limit ......................................................................................................................... 20 7.3.2. Test Procedure Used ....................................................................................................... 20 7.3.3. Test Setting ..................................................................................................................... 20 7.3.4. Test Setup ....................................................................................................................... 20 7.3.5. Test Result of Output Power ............................................................................................ 21 7.4. Power Spectral Density Measurement ..........................................................…
Text truncated - open the document above for the full version.
Report No.: 2405TW8601-UT 1 of 3 RF Test Photograph Description: Front View of Conducted Emission Test Setup Description: Back View of Conducted Emission Test Setup Report No.: 2405TW8601-UT 2 of 3 Description: Radiated Emission Test Setup for below 1GHz Description: Radiated Emission Test Setup for above 1GHz Report No.: 2405TW8601-UT 3 of 3 Description: Conducted Emission Test Setup
No. 38, Fuxing Second Rd., Guishan Dist., · Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 300.00 µW |

Arm Type Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission System
Non-Contact Thermometer
Equipment Class
DTS - Digital Transmission System
Non-Contact Thermometer
Equipment Class
DTS - Digital Transmission System
Multifunctional thermometer
Equipment Class
DTS - Digital Transmission System
IR Thermometer
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter