LI4278 LINEAR IMAGER LI4278 LINEAR IMAGER Zebra Technologies Corporation Lincolnshire, IL U.S.A. http://www.zebra.com 72-154896-08 Revision A - February 2023 ZEBRA and the stylized Zebra head are trademarks of Zebra Technologies Corp., registered in many jurisdictions worldwide. All other trademarks are the property of their respective owners. © 2023 Zebra Technologies Corp. and/or its aliates. All rights reserved. SCAN SUFFIX AVOID EXTREME WRIST ANGLES AVOID REACHING AVOID BENDING 012345012345 TROUBLESHOOTING Low/medium/high beep Power up Short medium beep Bar code decoded 4 long low beeps Transmission error detected; data is ignored 4 short beeps Low battery Standard UseHand-Held Scanning High/low beep Correct programming sequence performed Low/high beep Incorrect programming sequence or “Cancel” bar code scanned High/low/high/low beep Successful parameter setting Parameter Menu Scanning BEEPER INDICATIONSLED INDICATIONS O Scanner is on and ready to scan, or no power to scanner Green Bar code is successfully decoded Red Transmission error Hands-Free (Presentation) Scanning O No power to scanner O Momentarily Bar code is successfully decoded Green Scanner is ready to scan Red Transmission error Local Contact: SCANNING High/low beep Bluetooth disconnection Low/high beep Bluetooth connection established High/low/high/low beep Pairing bar code scanned Wireless Operation Charging O No power to scanner Green - Fast Continuous Scanner is charging Green - Slow Continuous Non-critical battery temperature fault Green - Solid Scanner is fully charged Aiming No power to scanner Check system power; battery may be discharged; charge scanner in cradle; check battery door is closed; ensure battery end cap is secured Scanner is disabled Ensure that correct host interface cable is used Scan appropriate host parameter bar codes Ensure all cable connections are secure Scanner not working Bar code unreadable Ensure bar code is not defaced; try scanning test bar code of same bar code type Distance between scanner and bar code incorrect Move scanner closer to or further from bar code Scanner not programmed for bar code type Ensure scanner is programmed to read type of bar code being scanned Scanner not decoding bar code Scanner not programmed for correct host interface Interface cable is loose Scanner decoding bar code, but data not transmitting to host Scanner not programmed for correct host interface Scan appropriate host parameter bar codes Scanned data incorrectly displayed on host Pair the scanner to the cradle Scanner not paired to host-connected interface In this order: disconnect power supply; disconnect host cable; wait three seconds; reconnect host cable; reconnect power supply; reestablish pairing Cradle lost connection to host Battery is above or below normal operating temperature Do not use scanner; move scanner to location with normal operating temperature; refer to the Product Reference Guide for more information LED indicates battery temperature Low battery start-up Wait for red LED to turn green indicating scanner is charging Cradle communication error Inspect contacts; remove and reinsert scanner in cradle LED indicates low battery start-up RECOMMENDED USAGE GUIDE - OPTIMUM BODY POSTURE REGULATORY INFORMATION Health and Safety Recommendations Avoid Extreme Wrist Angles Avoid ReachingAvoid Bending POST IN WORK AREA B Zebra reserves the right to make changes to any product to improve reliability, function, or design. Zebra does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Zebra products might be used. An implied license exists only for equipment, circuits, and subsystems contained in Zebra products. Service Information If you have a problem using the equipment, contact your facility’s Technical or Systems Support. If there is a problem with the equipment, they will contact the Zebra Global Customer Support Center at: http://www.zebra.com/support. For the latest version of this guide go to: http://www.zebra.com/support. Power Supply Use only approved power supply. The power supply shall be Listed to UL/CSA 60950-1 and certied to IEC60950-1 and EN60950-1 with SELV outputs. Use of alternative power supply will invalidate any approval given to this device and may be dangerous. TURKISH WEEE Statement of Compliance EEE Yönetmeliğine Uygundur Korea Warning Statement for Class B ITE Aim/Illumination Optical Output: 0.87mW Pulse Duration: Continuous Emitted Wavelength: 590-650nm Viewing the LED output with certain optical instruments (for example, eye loupes, magniers and microscopes) may pose an eye hazard. Caution: Use of controls or adjustments or performance of procedures other than those specied herein may result in hazardous LED light exposure. Japan (VCCI) - Voluntary Control Council for Interference Class B ITE Marking and European Economic Area (EEA) Statement of Compliance Zebra hereby declares that this radio equipment is in compliance with Directives 2014/53/EU and 2011/65/ EU. Any radio operation limitations within EEA countries are identied in Appendix A of EU Declaration of Conformity. The full text of the EU Declaration of Conformity is available at: zebra.com/doc. EU Importer: Zebra Technologies B.V Address: Mercurius 12, 8448 GX Heerenveen, Netherlands Radio Transmitters TThis device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. L’émetteur/…
Text truncated - open the document above for the full version.
Regulatory Engineering Zebra Technologies Corporation 1 Zebra Plaza, | Holtsville, NY 11742 | 1.631.738.2400 phone | 1.631.627.7179 fax | www.zebra.com Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: February 17, 2023 Ref: Attestation Statements Part 2.911(d)(7) Filing Grantee Code: UZ7 Zebra Technologies Corporation (“the applicant”) certifies that, as of the date of the filing of the application, [Zebra Technologies Corporation] is our designated U.S. agent for service of process for the above referenced grantee code. Zebra Technologies Corporation accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the agent information changes. [Zebra Technologies Corporation] accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced grantee code. Designated U.S. Agent Information: Name: Zebra Technologies Corporation FRN: 0015642663 Address: 1 Zebra Plaza, Holtsville, New York, United States, 11742 Contact Person: Larry (Qianlin) Zhou Tel.: 346-260-3543 Email: [email protected] Sincerely, Applicant U.S. Agent Zebra Technologies Corporation Zebra Technologies Corporation Larry (Qianlin) Zhou Larry (Qianlin) Zhou
Regulatory Engineering Zebra Technologies Corporation 1 Zebra Plaza, | Holtsville, NY 11742 | 1.631.738.2400 phone | 1.631.627.7179 fax | www.zebra.com Date: March 30, 2023 Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: FCC ID: UZ7LI4278A AUTHORIZATION LETTER We, the undersigned, hereby authorize Sporton International Inc. to act on our behalf in all manners relating to FCC application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Sporton International Inc. on our behalf shall have the same effect as acts of our own. If you have any acknowledgement and response, please send it to Sporton International Inc. directly. Confidentiality Request Pursuant to the provisions of Sections 0.457 and 0.459 of Commission’s rules (47CFR§§0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure indefinitely. Schematic Diagram Block Diagram Part List Operational Description Tune-up Procedure Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’ s policy, in order to comply with the marketing regulations in 47 CFT §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant shot-term confidentiality request on the following attachment(s) for 180 days after the grant as outlined in Public Notice DA 04-1705. Regulatory Engineering Zebra Technologies Corporation 1 Zebra Plaza, | Holtsville, NY 11742 | 1.631.738.2400 phone | 1.631.627.7179 fax | www.zebra.com Internal Photos External Photos Test Setup Photos User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. If you have any questions regarding this authorization, please contact me directly. Signature : _______________________________ Name and Job Title. : Larry (Qianlin) Zhou / Regulatory Specialist E-mail : [email protected] Tel. : 346-260-3543
PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 1 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 1. External Photograph of EUT Brand Name: Zebra / Model Name: LI4278A PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 2 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 3 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 4 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 5 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 6 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 7 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 2. Photograph of Accessory Brand Name: Zebra / Model Name: LI4278A Specification of Accessory Battery Brand Name Zebra Part Number 82-67705-01 Bluetooth Presentation Cradle Brand Name Zebra Part Number CR0078 Charge only Cradle Brand Name Zebra Part Number STB4208 Supported Unit used in test configuration and system AC Adapter Brand Name Zebra Part Number PWR-WUA5V4W0US Remark: For accessories equipped with this EUT, please refer to the following photos. PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 8 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 9 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 Battery PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 10 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 11 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 12 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 Bluetooth Presentation Cradle PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 13 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 14 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 Charge only Cradle PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 15 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 16 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 AC Adapter
HOLTSVILLE, NY 11742 DRAWING SCALE: 1 / 1 PRINTOUT @ 100% OF ACTUAL SIZE Do NOT Change Colors, Size or Type Fonts in the Artwork Please Note: PRINTER NOTE: This proof indicates color break only and may not accurately reflect actual production colors. Die lines and call-outs are for reference only - DO NOT PRINT. This title block must remain on the electronic file for all proofs. DWG. NO.: AR-002033-01 Date: 10/05/22 REV A Drawn By: C. Franco Approved by: CONFIDENTIAL AND PROPRIETARY ©ZIH CORP. 2005 ALL RIGHTS RESERVED THE INFORMATION CONTAINED HEREIN IS THE CONFIDENTIAL AND THE EXCLUSIVE PROPERTY OF ZIH CORP. THIS DOCUMENT, AND THE INFORMATION CONTAINED HEREIN, SHALL NOT BE COPIED, REPRODUCED, PUBLISHED, DISPLAYED OR DISTRIBUTED, IN WHOLE OR IN PART, IN ANY MEDIUM, BY ANY MEANS, FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF ZIH CORP. DIMENSIONS ARE IN MM MFD: XXXXXXX MADE IN : XXXXXXX BD ADDR : XXXXXXX P/N: LI4278-XXXXXXXXXXXX SN BAR CODE S/N: XXXXXXXXXXXXX MODEL: LI4278A 6.4V 500mA COMPLIES WITH IEC/EN 62471:2006/8 ICES/NMB-003 CLASS B FCC ID: UZ7LI4278A IC: 109AN-LI4278A . . . Symbol Technologies Inc. N.Y. 1 1742 D39706 R-R-ZTC-LI4278A 50 RoHS Pats.: ip.zebra.com 7 5 4 PROD FAM: LI4278A DESCRIPTION: LBL: LCD, LI4278A LED ONLY, CORDLESS (R) CTRY CODE: WW CCG1: AA02 NOTES: 1. SCRIPT FILE TO BE CREATED BY MANUFACTURING PER SP-10083-01 SCRIPT FILE MUST MATCH 0203301A EXACTLY AND HAVE SAME REVISION. 2. LABEL STOCK P/N IS SUBJECT TO CHANGE. CHECK BOM FOR ACTUAL PART NUMBER. 3. ALL CASES "XXX..." REPRESENTS VARIABLE FIELDS IN SCRIPT FILE. 4. SERIAL NUMBER MUST BE 4PT MINIMUM CHARACTER HEIGHT IN SCRIPT FILE. 5. PART NUMBER MAY OR MAY NOT HAVE DASH BEFORE COUNTRY CODE. SEE BOM FOR ACTUAL MODEL DESCRIPTION. 6. "MFD:" REPRESENTS MANUFACTURE DAY, MONTH, YEAR (IE: 12SEP15) 7. COUNTRY OF ORIGIN REQUIRED. 8. PLANT CODE REQUIRED. TO BE LOCATED BY MANUFACTURING FOR BEST FIT IN SCRIPT FILE. 9. LBL STOCK PN: 63-154404-01 10. MARKING AND APPROVAL NUMBERS ON GRAY TO BE ADDED AND PRINT WHEN CERTIFICATION IS COMPLETED. 3.00 mm 7.00 mm 5.00 mm 50 6 MARKINGS AND DIMENSIONS SHALL REMAIN THE SAME SIZE WHEN PRINTED.
PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 17 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 3. Internal Photograph of EUT Brand Name: Zebra / Model Name: LI4278A PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 18 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 19 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 20 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 21 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 22 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 23 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 24 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 25 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 26 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 27 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 28 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 29 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 30 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 31 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP261103 TEL : 886-3-327-3456 Page Number : 32 of 32 FAX : 886-3-328-4978 Issue Date : Feb. 06, 2023 Report Version : 01 ─────THE END──── Bluetooth Antenna
SPORTON INTERNATIONAL INC. Page Number : 1 of 3 TEL : 886-3-327-3456 Report Issued Date : Feb. 24, 2023 FAX : 886-3-328-4978 Report Version : Rev. 01 RF Exposure Evaluation Report Report No. : FA261103 RF Exposure Evaluation Report FCC ID : UZ7LI4278A Equipment : LINEAR IMAGER Brand Name : Zebra Model Name : LI4278A Applicant : Zebra Technologies Corporation 1 Zebra Plaza, Holtsville, NY 11742 Manufacturer : Zebra Technologies Corporation 1 Zebra Plaza, Holtsville, NY 11742 Standard : 47 CFR Part 2.1093 We, SPORTON INTERNATIONAL INC has been evaluated this product in accordance with 47 CFR Part 2.1093 and it complies with applicable limit. Sporton Lab is accredited to ISO 17025 by Taiwan Accreditation Foundation (TAF code: 1190) and the FCC designation No. TW1190 under the FCC 2.948(e) by Mutual Recognition Agreement (MRA) in FCC evaluation. The results in this report apply exclusively to the tested model / sample. Without written approval of SPORTON INTERNATIONAL INC. Laboratory, the test report shall not be reproduced except in full SPORTON INTERNATIONAL INC. EMC & Wireless Communications Laboratory No. 52, Huaya 1st Rd., Guishan Dist., Taoyuan City, Taiwan (R.O.C.) Approved by: Cona Huang / Deputy Manager SPORTON INTERNATIONAL INC. Page Number : 2 of 3 TEL : 886-3-327-3456 Report Issued Date : Feb. 24, 2023 FAX : 886-3-328-4978 Report Version : Rev. 01 RF Exposure Evaluation Report Report No. : FA261103 Table of Contents 1. General Information ........................................................................................................................... 3 1.1 Description of Device Under Test (DUT) ........................................................................................... 3 2. Maximum RF output power among production units ......................................................................... 3 3. RF Exposure Evaluation .................................................................................................................... 3 Revision History REPORT NO. VERSION DESCRIPTION ISSUED DATE FA261103 Rev. 01 Initial issue of report Feb. 24, 2023 SPORTON INTERNATIONAL INC. Page Number : 3 of 3 TEL : 886-3-327-3456 Report Issued Date : Feb. 24, 2023 FAX : 886-3-328-4978 Report Version : Rev. 01 RF Exposure Evaluation Report Report No. : FA261103 1. General Information 1.1 Description of Device Under Test (DUT) Product Feature & Specification DUT Type LINEAR IMAGER Brand Name Zebra Model Name LI4278A FCC ID UZ7LI4278A Wireless Technology and Frequency Range Bluetooth: 2402 MHz ~ 2480 MHz Mode Bluetooth BR/EDR/LE HW Version DV MFD 13OCT22 DUT Stage Production Unit 2. Maximum RF output power among production units Band / Mode Average Power (dBm) BR / EDR 1M 2M 3M Bluetooth 3.51 3.52 3.58 3. RF Exposure Evaluation Bluetooth Max Power (dBm) mW Separation Distance (mm) Frequency (GHz) Exclusion Thresholds 3.58 2.28 5 2.48 0.72 Note: 1. Per KDB 447498 D01v06 the 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison Conclusion: Per KDB 447498 D01v06, when the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. The test exclusion threshold is 0.72 which is <= 3, SAR testing is not required.
客 客 戶 戶 名 名 稱 稱 C C U U S S T T O O M M E E R R 承 承 認 認 書 書 A A P P P P R R O O V V A A L L S S H H E E E E T T 產 產 品 品 品 品 名 名 / / P P r r o o d d u u c c t t M M o o d d e e l l N N o o . . : : ACA-2003-P1-GF-S Model: Rhino BT Antenna 客 客 戶 戶 料 料 號 號 / / C C u u s s t t o o m m e e r r N N o o . . : : 50-11900-032 發 發 行 行 日 日 期 期 / / I I s s s s u u e e D D a a t t e e : : 2020/10/19 承 承 認 認 日 日 期 期 / / A A p p p p r r o o v v e e d d D D a a t t e e : : A A p p p p r r o o v v e e d d b b y y c c u u s s t t o o m m e e r r : : ( ( s s i i g g n n i i n n g g o o r r s s t t a a m m p p i i n n g g h h e e r r e e ) ) ■ 350 苗栗縣竹南鎮公義里11鄰科義街11號 電話:037-585-555 傳真:037-585-511 □ 428 台中市大雅區科雅路27號4樓 電話:04-2560-6555 傳真:04-2560-5151 No. 11, Ke-Yi St., Chunan, Miaoli 350, Taiwan, R.O.C. Tel.:+886-37-585-555 Fax:+886-37-585-511 4F,No.27,Keya Road,Daya Dist.,Taichung City 428, Taiwan,R.O.C. Tel.:+886-4-25606555 Fax:+886-4-25605151 : Zebra Document No.: ENS070008800 . Approval Sheet Rev.: A0 . Spec. Rev. : P1 . 佳邦科技股份有限公司 INPAQ TECHNOLOGY CO., LTD. I-FM-19-03 E UNLESS OTHER SPECIFIED TOLERANCES ON: INPAQ TECHNOLOGY CO., LTD. X=N/R X.X=N/R X.XX =N/R ANGLES=N/R HOLEDIA=N/R SCALE:N/R UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY:Darren CHECKED BY:Darren DESIGNED BY:Kerry APPROVED BY: MACRO TITLE:ACA-2003-P1-GF-S DOCUMENT ENS070008800-000824000427 SPEC REV. NO. A0 PAGE 1 OF 9 品名:ACA-2003-P1-GF-S History List 版本 REV. 修訂者 EDITOR 修訂頁次 PAGE 修訂內容 ITEMS OF CHANGE 申請日期 DATE 生效日期 VALID DATE ECN編號 ECN NO. A0 王牧生 All New Release 2020/10/13 According to the date of PLM Release N/A UNLESS OTHER SPECIFIED TOLERANCES ON: INPAQ TECHNOLOGY CO., LTD. X=N/R X.X=N/R X.XX =N/R ANGLES=N/R HOLEDIA=N/R SCALE:N/R UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY:Darren CHECKED BY:Darren DESIGNED BY:Kerry APPROVED BY: MACRO TITLE:ACA-2003-P1-GF-S DOCUMENT ENS070008800-000824000427 SPEC REV. NO. A0 PAGE 2 OF 9 品名:ACA-2003-P1-GF-S 1. Explanation of Part Number: AC A _ 2003 P1 _ GF _ S _ _ (1) (2) (3) (4) (5) (6) (7) (1) Product Type:Chip Antenna (2) Center Frequency/Band Code:A -2.45GHz (3) Size Code:20.5mm(length) x 3.6mm(width) (4) Design Revision Code:P1= Rev. 1 (5) Series No.:GF=On Ground FR4 (6) Special Code:S= RoHS Compliant (7) Suffix For Special Requirements 2. Electrical Specification: ITEM SPECIFICATION Working Frequency Range 2400 ~ 2500 MHz Peak Gain 1.2 dBi (Typical) Return Loss -10 dB (Typical) Polarization Linear Feed Impedance 50Ω Operating Temperature -40 ~ 85 °C *Note:Central Frequency should be defined after customer’s application approval. UNLESS OTHER SPECIFIED TOLERANCES ON: INPAQ TECHNOLOGY CO., LTD. X=N/R X.X=N/R X.XX =N/R ANGLES=N/R HOLEDIA=N/R SCALE:N/R UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY:Darren CHECKED BY:Darren DESIGNED BY:Kerry APPROVED BY: MACRO TITLE:ACA-2003-P1-GF-S DOCUMENT ENS070008800-000824000427 SPEC REV. NO. A0 PAGE 3 OF 9 3. Physical Dimension: TOP Bottom Side Outline of Free Antenna Chip Antenna L W T PW P1 P2 P3 P4 Dimension(mm) 20.5±0.2 3.6±0.2 4.0±0.2 3.2±0.1 1.2±0.1 1.2±0.1 1.2±0.1 1.2±0.1 PIN Difinition P1 Soldering P2 Soldering P3 Feed P4 Ground UNLESS OTHER SPECIFIED TOLERANCES ON: INPAQ TECHNOLOGY CO., LTD. X=N/R X.X=N/R X.XX =N/R ANGLES=N/R HOLEDIA=N/R SCALE:N/R UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY:Darren CHECKED BY:Darren DESIGNED BY:Kerry APPROVED BY: MACRO TITLE:ACA-2003-P1-GF-S DOCUMENT ENS070008800-000824000427 SPEC REV. NO. A0 PAGE 4 OF 9 4. Recommend PCB Layout: SOLDER LAND PATTERN DESIGN EVB SIZE (mm) Test EVB 90 x 40 x 0.8 UNLESS OTHER SPECIFIED TOLERANCES ON: INPAQ TECHNOLOGY CO., LTD. X=N/R X.X=N/R X.XX =N/R ANGLES=N/R HOLEDIA=N/R SCALE:N/R UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY:Darren CHECKED BY:Darren DESIGNED BY:Kerry APPROVED BY: MACRO TITLE:ACA-2003-P1-GF-S DOCUMENT ENS070008800-000824000427 SPEC REV. NO. A0 PAGE 5 OF 9 5. Electrical Characteristics: Return Loss Frequency (MHz) S11(dB) 2400 -11.2 2450 -15.5 2500 -13.9 Radiation Pattern: The Gain pattern is measured in INPAQ’s FAR-field chamber. DUT is placed on the table of rotator, a standard horn antenna and Vector Network Analyzer is used to collect data. 3D Chamber Definition UNLESS OTHER SPECIFIED TOLERANCES ON: INPAQ TECHNOLOGY CO., LTD. X=N/R X.X=N/R X.XX =N/R ANGLES=N/R HOLEDIA=N/R SCALE:N/R UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY:Darren CHECKED BY:Darren DESIGNED BY:Kerry APPROVED BY: MACRO TITLE:ACA-2003-P1-GF-S DOCUMENT ENS070008800-000824000427 SPEC REV. NO. A0 PAGE 6 OF 9 (XZ plane) (YZ plane) (XY plane) ZX plane ZY plane XY plane Frequency [MHz] Max Value [dB] Average [dB] Max Value [dB] Average [dB] Max Value [dB] Average [dB] 2400 -1.37 -4.11 0.88 -2.20 0.29 -4.01 2450 -1.40 -4.05 1.18 -2.08 0.49 -3.86 2500 -1.42 -4.19 1.20 -2.12 0.31 -3.94 UNLESS OTHER SPECIFIED TOLERANCES ON: INPAQ TECHNOLOGY CO., LTD. X=N/R X.X=N/R X.XX =N/R ANGLES=N/R HOLEDIA=N/R SCALE:N/R UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR U…
Text truncated - open the document above for the full version.
TEL : 886-3-327-0868 Page Number : 1 of 48 FAX : 886-3-327-0855 Issue Date : Apr. 07, 2023 Report Template No.: BU5-FR15CBT Version 2.4 Report Version : 02 FCC RADIO TEST REPORT Report No. : FR261103 FCC RADIO TEST REPORT FCC ID : UZ7LI4278A Equipment : LINEAR IMAGER Brand Name : Symbol Technologies Inc. Model Name : LI4278A Applicant : Zebra 1 Zebra Plaza, Holtsville, NY 11742 Manufacturer : Symbol Technologies Inc. 1 Zebra Plaza, Holtsville, NY 11742 Standard : FCC Part 15 Subpart C §15.247 The product was received on Nov. 22, 2022 and testing was performed from Dec. 07, 2022 to Jan. 31, 2023. We, Sporton International Inc. Wensan Laboratory, would like to declare that the tested sample has been evaluated in accordance with the test procedures and has been in compliance with the applicable technical standards. The test results in this report apply exclusively to the tested model / sample. Without written approval from Sporton International Inc. Wensan Laboratory, the test report shall not be reproduced except in full. Approved by: Louis Wu Sporton International Inc. Wensan Laboratory No.58, Aly. 75, Ln. 564, Wenhua 3rd, Rd., Guishan Dist., Taoyuan City 333010, Taiwan (R.O.C.) TEL : 886-3-327-0868 Page Number : 2 of 48 FAX : 886-3-327-0855 Issue Date : Apr. 07, 2023 Report Template No.: BU5-FR15CBT Version 2.4 Report Version : 02 FCC RADIO TEST REPORT Report No. : FR261103 Table of Contents History of this test report ................................................................................................................................. 3 Summary of Test Result................................................................................................................................... 4 1 General Description ................................................................................................................................... 5 1.1 Product Feature of Equipment Under Test ........................................................................................ 5 1.2 Product Specification of Equipment Under Test ................................................................................ 5 1.3 Modification of EUT ........................................................................................................................... 5 1.4 Testing Location .....................................................................................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 3.60 mW |
Cordless Scanner
Equipment Class
DTS - Digital Transmission SystemCordless Scanner
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterTouch Computer
Equipment Class
CBE - Citizens Band End User DevicesTouch Computer
Equipment Class
NII - Unlicensed National Information Infrastructure TXTouch Computer
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter