Regulatory Engineering Zebra Technologies Corporation 1 Zebra Plaza, | Holtsville, NY 11742 | 1.631.738.2400 phone | 1.631.627.7179 fax | www.zebra.com Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia MD 21046 USA Date: April 12, 2024 Ref: Attestation Statements Part 2.911(d)(7) Filing Grantee Code: UZ7 Zebra Technologies Corporation (“the applicant”) as required by section 2.911(d)(7), will also serve as the agent for service of process for the above referenced FCC Grantee Code. The service of process includes, but is not limited to, delivery of any correspondence, notices, orders, decisions, and requirements of administrative, legal, or judicial process related to Commission proceedings. The applicant acknowledges that they will maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. The applicant further acknowledges their responsibility to inform the FCC whenever the following agent information changes. Company Name: Zebra Technologies Corporation Company US Address: 1 Zebra Plaza, Holtsville, New York, United States, 11742 Contact Person: Larry (Qianlin) Zhou Email: [email protected] Telephone number: 346-260-3543 FRN: 0015642663 Sincerely yours, Signed by the Applicant Signature : _______________________________ Name and Job Title. : Larry (Qianlin) Zhou / Regulatory Specialist E-mail : [email protected] Tel. : 346-260-3543
Regulatory Engineering Zebra Technologies Corporation 1 Zebra Plaza, | Holtsville, NY 11742 | 1.631.738.2400 phone | 1.631.627.7179 fax | www.zebra.com Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: July 3, 2024 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: UZ7TC530R Zebra Technologies Corporation (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Signature : _______________________________ Name and Job Title. : Larry (Qianlin) Zhou / Regulatory Specialist E-mail : [email protected] Tel. : 346-260-3543 Regulatory Engineering Zebra Technologies Corporation 1 Zebra Plaza, | Holtsville, NY 11742 | 1.631.738.2400 phone | 1.631.627.7179 fax | www.zebra.com Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: July 3, 2024 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: UZ7TC530R Zebra Technologies Corporation (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, Signature : _______________________________ Name and Job Title. : Larry (Qianlin) Zhou / Regulatory Specialist E-mail : [email protected] Tel. : 346-260-3543
Regulatory Engineering Zebra Technologies Corporation 1 Zebra Plaza, | Holtsville, NY 11742 | 1.631.738.2400 phone | 1.631.627.7179 fax | www.zebra.com Date: July 3, 2024 Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: FCC ID: UZ7TC530R AUTHORIZATION LETTER We, the undersigned, hereby authorize Jones Tsai in Sporton International Inc. to act on our behalf in all manners relating to FCC application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Jones Tsai in Sporton International Inc. on our behalf shall have the same effect as acts of our own. If you have any acknowledgement and response, please send it to Sporton International Inc. directly. Confidentiality Request Pursuant to the provisions of Sections 0.457 and 0.459 of Commission’s rules (47CFR§§0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure indefinitely. Schematic Diagram Block Diagram Part List Operational Description Tune-up Procedure Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’ s policy, in order to comply with the marketing regulations in 47 CFT §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant shot-term confidentiality request on the following attachment(s) for 180 days after the grant as outlined in Public Notice DA 04-1705. Regulatory Engineering Zebra Technologies Corporation 1 Zebra Plaza, | Holtsville, NY 11742 | 1.631.738.2400 phone | 1.631.627.7179 fax | www.zebra.com Internal Photos External Photos Test Setup Photos User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Label Location Attestation We attest that the label of device FCC ID: UZ7TC530R is located in the battery room. The label is visible to the users as they purchase the product and install the battery. If you have any questions regarding this authorization, please contact me directly. Signature : _______________________________ Name and Job Title. : Larry (Qianlin) Zhou / Regulatory Specialist E-mail : [email protected] Tel. : 346-260-3543
Regulatory Engineering Zebra Technologies Corporation 1 Zebra Plaza, | Holtsville, NY 11742 | 1.631.738.2400 phone | 1.631.627.7179 fax | www.zebra.com Date: July 3, 2024 Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: FCC ID: UZ7TC530R AUTHORIZATION LETTER We, the undersigned, hereby authorize Jones Tsai in Sporton International Inc. to act on our behalf in all manners relating to FCC application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Jones Tsai in Sporton International Inc. on our behalf shall have the same effect as acts of our own. If you have any acknowledgement and response, please send it to Sporton International Inc. directly. Confidentiality Request Pursuant to the provisions of Sections 0.457 and 0.459 of Commission’s rules (47CFR§§0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure indefinitely. Schematic Diagram Block Diagram Part List Operational Description Tune-up Procedure Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’ s policy, in order to comply with the marketing regulations in 47 CFT §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant shot-term confidentiality request on the following attachment(s) for 180 days after the grant as outlined in Public Notice DA 04-1705. Regulatory Engineering Zebra Technologies Corporation 1 Zebra Plaza, | Holtsville, NY 11742 | 1.631.738.2400 phone | 1.631.627.7179 fax | www.zebra.com Internal Photos External Photos Test Setup Photos User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Label Location Attestation We attest that the label of device FCC ID: UZ7TC530R is located in the battery room. The label is visible to the users as they purchase the product and install the battery. If you have any questions regarding this authorization, please contact me directly. Signature : _______________________________ Name and Job Title. : Larry (Qianlin) Zhou / Regulatory Specialist E-mail : [email protected] Tel. : 346-260-3543
Regulatory Engineering Zebra Technologies Corporation 1 Zebra Plaza, | Holtsville, NY 11742 | 1.631.738.2400 phone | 1.631.627.7179 fax | www.zebra.com Date: July 3, 2024 Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: FCC ID: UZ7TC530R AUTHORIZATION LETTER We, the undersigned, hereby authorize Jones Tsai in Sporton International Inc. to act on our behalf in all manners relating to FCC application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Jones Tsai in Sporton International Inc. on our behalf shall have the same effect as acts of our own. If you have any acknowledgement and response, please send it to Sporton International Inc. directly. Confidentiality Request Pursuant to the provisions of Sections 0.457 and 0.459 of Commission’s rules (47CFR§§0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure indefinitely. Schematic Diagram Block Diagram Part List Operational Description Tune-up Procedure Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’ s policy, in order to comply with the marketing regulations in 47 CFT §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant shot-term confidentiality request on the following attachment(s) for 180 days after the grant as outlined in Public Notice DA 04-1705. Regulatory Engineering Zebra Technologies Corporation 1 Zebra Plaza, | Holtsville, NY 11742 | 1.631.738.2400 phone | 1.631.627.7179 fax | www.zebra.com Internal Photos External Photos Test Setup Photos User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Label Location Attestation We attest that the label of device FCC ID: UZ7TC530R is located in the battery room. The label is visible to the users as they purchase the product and install the battery. If you have any questions regarding this authorization, please contact me directly. Signature : _______________________________ Name and Job Title. : Larry (Qianlin) Zhou / Regulatory Specialist E-mail : [email protected] Tel. : 346-260-3543
1. MATERIAL: WHITE POLYESTER_HTYL75(EB)(BL)EZL (T=0.076+0.033mm) +PPATMA(T)36NJ (T=0.021+0.018mm)可打印霧P.P. 2. ADHESIVE: 壓花永久膠 3. PRINTING COLOR: LETTERS-------------- BLACK BACKGROUND------ WHITE TEXT-------------------- BLACK 4. LABEL DIMENSION TOLERANCE: +0mm / -0.2mm 5. THE MATERIAL MUST BE APPROVED BY ZEBRA & UL Certification MODEL NO.: PART NAME: A/W NO.: SCALE: UNIT : SHEET OF DRAWN:REVIEWED: APPROVED: REVDESCRIPTIONSIGN DATE 1 : 1 1 1 1 : 1 mm 1 1 Wistron Corporation Cut Line 1ZA.06P01.C001 FCC ID: UZ7TC530R IC : 109AN-TC530R US : 1KOIPNANTC530R 56.9 mm 47.1 mm54.1 mm 24.95 mm 15.8 mm 34.5 mm 91.95 mm 54.1 mm 37.85 mm 45.1 mm R0.7mm*4 R2mm*4 R2mm*4 5V 2.5A MODEL: TC530R P/N: XXXXXXXXXXXXXXXXXX (S) S/N: XXXXXXXXXXXXXX WIFI MAC ID: XXXXXXXXXXXX BT MAC ID: XXXXXXXXXXXX MFD:DDMMMYY Rev:X XXX Made in XXXXXX ( XXXX ) Size:5*5mm(2D BARCODE) For P/N: (S) S/N: WIFI/MAC ID: BT MAC ID: Size:5*5mm(2D BARCODE) For (S) S/N: Factory ID Code: WKS B1 – KS WKS B6 – KS2 WKS C2 – KS3 WIH – M2 WMY – WM Printed by Wistron’s Factory Font: Arial 6 pt 19.00 mm Zebra logo Size Minimum required: 19.00 mm wide or more Do not scale unproportional Do not modify or change logo layout. Keep same format 6mm 16.566 mm THUNDERBOLT(STD) TC530R WLAN RFID - US- Spec Label WKS Printed Made in China WIH Printed Made in Taiwan WMY Printed Made in Malaysia 10mm 6.84mm 8mm 9.512 mm 11mm 7.468mm 3.496mm 8.826mm A A Released P/N and Rev.A 2024/4/11 CountrySuffix US 900Mhz RFID for US and Canada or US Only non-RFID Rev. 0 Change log description Drfat for RFID SKU2024/3/21 Date Sammi Cheng 2024/4/11 Nionio Chen 2024/4/11 9.60mm
Sim Door Spec. label Back Side / battery recess Laser
TEL : 886-3-327-3456 Page : F1 of F15 FAX : 886-3-328-4978 FCC SAR TEST REPORT Report No. :FA430824 Appendix F. Proximity sensor validation Since proximity sensor validation procedure in KDB 616217 section 6.2/6.3/6.4 are for body exposure condition, therefore that procedure is not full applicable proximity sensor detection verification for the head exposure condition, following sensor validation procedure will be applied for head and near the front of face exposure condition 11.1 Proximity sensor validation procedure for Head exposure condition The following guidance only for the device integrated proximity sensor to reduce power or disable RFID transmit and applies head exposure condition. The earpiece of device positioned on the left and right ERP (ear reference point) location of head phantom defined in IEEE Std 1528-2013 and rotates the device along one axis, from 0 degrees to 90 degrees and then reverse the procedure to go from 90 degrees to 0 degrees. Establish OTT VoIP call (through WIFI data) and audio is actively routed through the earpiece receiver (earpiece is ON). This process is to determine the angle where a power reduction occurs, by taking power measurements at each step, as indicated in the step listed here below: i. From the device in 0 degrees, rotate in 10 degrees steps until proximity sensor is release ii. Lower the device rotate by 5 degrees increments to verify that the “proximity sensor” is triggered iii. From the position of the previous step, rotate the device in 1 degree increments until proximity sensor is Triggered again iv. Continue rotate the device in 1 degree increments until at least 5 degrees past where proximity sensor is release was obtained, then continue rotate device in 10 degrees steps until the device opened to 90 degrees with proximity sensor is release. v. Reverse the previous procedure to go from device 90 degrees back down to 0 degrees TEL : 886-3-327-3456 Page : F2 of F15 FAX : 886-3-328-4978 FCC SAR TEST REPORT Report No. :FA430824 Rotate the device from 0 degree to 90 degree _Right Head Device angle (degree) Angle Proximity sensor 0 On 10 On 20 On 30 On 40 On 50 On 60 On 70 On 80 On 81 On 82 On 83 On 84 On 85 On 86 On 87 Off 88 Off 89 Off 90 Off TEL : 886-3-327-3456 Page : F3 of F15 FAX : 886-3-328-4978 FCC SAR TEST REPORT Report No. :FA430824 Rotate the device from 90 degree to 0 degree _Right Head Device angle (degree) Angle Proximity sensor 90 Off 89 Off 88 Off 87 Off 86 Off 85 Off 84 Off 83 Off 82 Off 81 On 80 On 70 On 60 On 50 On 40 On 30 On 20 On 10 On 0 On TEL : 886-3-327-3456 Page : F4 of F15 FAX : 886-3-328-4978 FCC SAR TEST REPORT Report No. :FA430824 Rotate the device from 0 degree to 90 degree_Left Head Device angle (degree) Angle Proximity sensor 0 On 10 On 20 On 30 On 40 On 50 On 60 On 70 On 80 On 81 On 82 On 83 On 84 On 85 On 86 Off 87 Off 88 Off 89 Off 90 Off TEL : 886-3-327-3456 Page : F5 of F15 FAX : 886-3-328-4978 FCC SAR TEST REPORT Report No. :FA430824 Rotate the device from 90 degree to 0 degree_Left Head Device angle (degree) Angle Proximity sensor 90 Off 89 Off 88 Off 87 Off 86 Off 85 Off 84 Off 83 Off 82 On 81 On 80 On 70 On 60 On 50 On 40 On 30 On 20 On 10 On 0 On 11.2 Proximity sensor validation procedure for near the front of the face In order to consider front of device near the front of the face during VOIP call, hereunder is for proximity sensor validation procedure and results for determining proximity sensor triggering distance and ensure the trigger distance is larger than front of device test at 10 mm distance. a) The entire front surface of the device is positioned below a flat phantom filled with the required tissue- equivalent medium, and positioned at least 20 mm further than the distance that triggers power reduction b) The front surface is moved toward the phantom in 3 mm steps until the sensor triggers. c) The front surface is then moved back (further away) from the phantom by at least 5 mm or until maximum output power is returned to the normal maximum level. d) The front surface is again moved toward the phantom, but in 1 mm steps, until it is at least 5 mm past the triggering point or touching the phantom. e) If the device is not touching the phantom, it is moved in 3 mm steps until it touches the phantom to confirm that the sensor remains triggered and the maximum power stays reduced. TEL : 886-3-327-3456 Page : F6 of F15 FAX : 886-3-328-4978 FCC SAR TEST REPORT Report No. :FA430824 f) The process is then reversed by moving the device away from the phantom according to steps b) to e), to determine triggering release, until it is at least 10 mm beyond the point that triggers the return of normal maximum power. i) The measured output power within +/- 5 mm of the triggering points, or until the device is touching the phantom, for movements to and from the phantom should be tabulated in the SAR report. Front of device moved toward the phantom Device Trigger distance Distance (mm) Proximity sensor 120 Off 118 Off 115 Off 112 Off 109 Off 106 Off 103 Off 100 Off 97 Off 94 Off 91 Off 88 Off 85 Off 83 Off 80 Off 77 Off 74 Off 71 Off 68 Off 65 Off 63 Off 62 Off 61 Off 60 Off 59 Off 58 ON 57 ON TEL : 886-3-327-3456 Page : F7 of F15 FAX : 886-3-328-4978 FCC SAR TEST REPORT Report No. :FA430824 56 ON 55 ON 54 ON 53 ON 50 ON 47 ON 44 ON 41 ON 38 ON 35 ON 32 ON 29 ON 26 ON 23 ON 20 ON 17 ON 14 ON 11 ON 8 ON 5 ON 2 ON 0 ON TEL : 886-3-327-3456 Page : F8 of F15 FAX : 886-3-328-4978 FCC SAR TEST REPORT Report No. :FA430824 Front of device moved back (further away) from the phantom Device Trigger distance Distance (mm) Proximity sensor 0 ON 3 ON 6 ON 9 ON 12 ON 15 ON 18 ON 21 ON 24 ON 27 ON 30 ON 33 ON 36 ON 39 ON 42 ON 45 ON 48 ON 51 ON 54 ON 57 ON 60 ON 63 ON 66 ON 69 ON 72 ON 75 ON 78 ON 81 ON 84 ON 87 ON 90 ON 93 ON TEL : 886-3-327-3456 Page : F9 of F15 FAX : 886-3-328-4978 FCC SAR TEST REPORT Report No. :FA430824 95 ON 96 ON 97 ON 98 ON 99 ON 100 Off 111 Off 112 Off 113 Off 114 Off 115 Off 118 Off 120 Off 1…
Text truncated - open the document above for the full version.
SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-328-4978 D900V2, serial no. 1d171 Extended Dipole Calibrations If dipoles are verified in return loss (<-20dB, within 20% of prior calibration), and in impedance (within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. <Justification of the extended calibration> D900V2 – serial no. 1d171 900MHZ Date of Measurement Return-Loss (dB) Delta (%) Real Impedance (ohm) Delta (ohm) Imaginary Impedance (ohm) Delta (ohm) 03.24.2022 (Cal. Report) -34.844 51.839 -0.12814 03.23.2023 (extended) -38.954 11.8 49.892 -1.947 1.7168 1.84494 03.22.2024 (extended) -33.513 -3.82 50.037 -1.802 -1.1740 -1.04586 The return loss is < -20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-328-4978 <Dipole Verification Data> - D900V2, serial no. 1d171 (Data of Measurement : 3.23.2023) 900 MHz - Head SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-328-4978 <Dipole Verification Data> - D900V2, serial no. 1d171 (Data of Measurement : 03.22.2024) 900 MHz - Head SP ORTON INTERNATIONAL INC. T EL : 886-3-327-3456 FAX : 886-3-328-4978 D2450V2, serial no. 736 Extended Dipole Calibrations If dipoles are verified in return loss (<-20dB, within 20% of prior calibration), and in impedance (within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. <Justification of the extended calibration> D2450V2 – serial no. 736 2450M HZ Da te of Measurement Re turn-Loss (dB) De lta (%) Re al Impedance (ohm) De lta (ohm) I maginary Impedance (ohm) De lta (ohm) 08.17.2021 (C al. Report) -24.29755.295 3.6377 08.16.2022 (ex tended) -28.76118.37 51.401 -3.8943.556 -0.0817 08.15.2023 (ex tended) -28.48317.23 51.239 -4.0563.496 -0.1417 T he return loss is < -20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-328-4978 <Dipole Verification Data> - D2450 V2, serial no. 736 (Data of Measurement : 08.16.2022) 2450 MHz - Head SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-328-4978 <Dipole Verification Data> - D2450V2, serial no. 736 (Data of Measurement : 08.15.2023) D2450V2 MHz - Head SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-328-4978 D2450V2, serial no. 929 Extended Dipole Calibrations If dipoles are verified in return loss (<-20dB, within 20% of prior calibration), and in impedance (within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. <Justification of the extended calibration> D2450V2 – serial no. 929 2450MHZ Date of Measurement Return-Loss (dB) Delta (%) Real Impedance (ohm) Delta (ohm) Imaginary Impedance (ohm) Delta (ohm) 11.21.2022 (Cal. Report) -25.5 52.9 4.7 11.20.2023 (extended) -25.9 1.57 52.3 -0.6 4.8 0.1 The return loss is < -20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-328-4978 <Dipole Verification Data> - D2450 V2, serial no. 929 (Data of Measurement : 11.20.2023) 2450MHz - Head SPORT ON INTERNATIONA L I NC. TE L : 886-3-327-3456 FA X : 886 -3-328-497 8 CLA13, serial no. 1022 Extended Dipole Calibrations If dipoles are verified in return loss (<-20dB, within 20% of prior calibration), and in impedance (within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. <Justification of the extended calibration> CLA13 – serial no. 1022 13MHZ Date of Measurement Return-Loss (dB) Delta (%) Real Impedance (ohm) Delta (ohm) Imaginary Impedance (ohm) Delta (ohm) 09.01.2022 (Cal. Report) -25.51848.364 4.9544 08.3 1.2023 (extended) -24.882 -2.4950.308 1.944 5.7239 0.7695 The return loss is < -20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-328-4978 <Dipole Verification Data> - CLA13, serial no. 1022 (Data of Measurement : 08.31.2023) 13 MHz - Head
Scans Setup Scan Type5G Scan Grid Extents [mm]180.0 x 120.0 Grid Steps [lambda]0.0625 x 0.0625 Sensor Surface [mm]2.0 Measurement Results Date2024-06-04 Avg. Area [cm 2 ] 4.00 psPDn+ [W/m 2 ] 3.22 psPDtot+ [W/m 2 ] 3.85 H max [A/m]0.141 E max [V/m]45.6 max (Stot) [W/m 2 ] 5.09 Power Drift [dB]0.15 IPDn8.26 Measurement Report for Device Device Under Test Properties Model, ManufacturerDimensions [mm]Software VersionDUT Type Device,170.0 x 79.0 x 20.03.2.0.1840Phone Exposure Conditions Phantom SectionPosition, Test Distance [mm]Frequency [MHz]Conversion Factor 5GFRONT, 2.006185.01.0 Hardware Setup PhantomMediumProbe, Calibration DateDAE, Calibration Date mmWave - xxxxAir -EUmmWV4 - SN9461_F1-55GHz, 2023-10-12DAE4ip Sn1823, 2023-07-31
0 dB = 0.650 W/kg = -1.87 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/7/5 #01_WLAN2.4GHz_802.11b 1Mbps_Left Cheek_0mm_Ch6;Ant 6+7 Communication System: UID 10415 -AAA, 802.11b; Frequency: 2437 MHz Medium: HSL_2450_240705 Medium parameters used: f = 2437 MHz; σ = 1.806 S/m; ε r = 40.169; ρ = 1000 kg/m 3 Ambient Temperature:23.2 °C; Liquid Temperature:22.2 °C DASY5 Configuration: - Probe: EX3DV4 - SN3642;ConvF(7.51, 6.73, 8.77) @ 2437 MHz;Calibrated: 2024/4/25 - Sensor-Surface: 1.4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn778; Calibrated: 2024/1/22 - Phantom: SAM_Left; Type: QD 000 P40 CD; Serial: TP:1685 - Measurement SW: DASY52, Version 52.10 (4);SEMCAD X Version 14.6.14 (7501) Area Scan (91x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 0.666 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 22.41 V/m; Power Drift = -0.05 dB Peak SAR (extrapolated) = 0.75 W/kg SAR(1 g) = 0.468 W/kg; SAR(10 g) = 0.265 W/kg Smallest distance from peaks to all points 3 dB below = 12.9 mm Ratio of SAR at M2 to SAR at M1 = 62.8% Maximum value of SAR (measured) = 0.650 W/kg 0 dB = 1.35 W/kg = 1.30 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/6/5 #02_WLAN5GHz_802.11n-HT40 MCS0_Left Cheek_0mm_Ch54;Ant 6+7 Communication System: UID 10599 - AAC, 802.11n ; Frequency: 5270 MHz Medium: HSL_5G_240605 Medium parameters used: f = 5270 MHz; σ = 4.607 S/m; ε r = 36.955; ρ = 1000 kg/m 3 Ambient Temperature:23.5 °C; Liquid Temperature:22.5 °C DASY5 Configuration: - Probe: EX3DV4 - SN3642;ConvF(4.46, 4.11, 5.36) @ 5270 MHz;Calibrated: 2024/4/25 - Sensor-Surface: 1.4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn778; Calibrated: 2024/1/22 - Phantom: SAM_Right; Type: SAM; Serial: TP:1815 - Measurement SW: DASY52, Version 52.10 (4);SEMCAD X Version 14.6.14 (7501) Area Scan (121x181x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm Maximum value of SAR (interpolated) = 1.09 W/kg Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm Reference Value = 17.00 V/m; Power Drift = -0.16 dB Peak SAR (extrapolated) = 2.34 W/kg SAR(1 g) = 0.588 W/kg; SAR(10 g) = 0.203 W/kg Smallest distance from peaks to all points 3 dB below = 8.5 mm Ratio of SAR at M2 to SAR at M1 = 62.8% Maximum value of SAR (measured) = 1.35 W/kg 0 dB = 1.82 W/kg = 2.60 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/6/5 #03_WLAN5GHz_802.11ac-VHT80 MCS0_Left Cheek_0mm_Ch122;Ant 6+7 Communication System: UID 10626 - AAC, 802.11ac; Frequency: 5610 MHz Medium: HSL_5G_240605 Medium parameters used: f = 5610 MHz; σ = 4.944 S/m; ε r = 36.475; ρ = 1000 kg/m 3 Ambient Temperature:23.5 °C; Liquid Temperature:22.5 °C DASY5 Configuration: - Probe: EX3DV4 - SN3642;ConvF(3.96, 3.67, 4.73) @ 5610 MHz;Calibrated: 2024/4/25 - Sensor-Surface: 1.4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn778; Calibrated: 2024/1/22 - Phantom: SAM_Right; Type: SAM; Serial: TP:1815 - Measurement SW: DASY52, Version 52.10 (4);SEMCAD X Version 14.6.14 (7501) Area Scan (121x181x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm Maximum value of SAR (interpolated) = 1.35 W/kg Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm Reference Value = 18.33 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 3.06 W/kg SAR(1 g) = 0.762 W/kg; SAR(10 g) = 0.275 W/kg Smallest distance from peaks to all points 3 dB below = 8.9 mm Ratio of SAR at M2 to SAR at M1 = 61.9% Maximum value of SAR (measured) = 1.82 W/kg 0 dB = 1.66 W/kg = 2.20 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/6/4 #04_WLAN5GHz_802.11ac-VHT80 MCS0_Right Cheek_0mm_Ch155;Ant 6+7 Communication System: UID 10626 - AAC, 802.11ac; Frequency: 5775 MHz Medium: HSL_5G_240604 Medium parameters used: f = 5775 MHz; σ = 5.38 S/m; ε r = 35.461; ρ = 1000 kg/m 3 Ambient Temperature:23.5 °C; Liquid Temperature:22.5 °C DASY5 Configuration: - Probe: EX3DV4 - SN3642;ConvF(4.03, 3.72, 4.8) @ 5775 MHz;Calibrated: 2024/4/25 - Sensor-Surface: 1.4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn778; Calibrated: 2024/1/22 - Phantom: SAM_Right; Type: SAM; Serial: TP:1815 - Measurement SW: DASY52, Version 52.10 (4);SEMCAD X Version 14.6.14 (7501) Area Scan (121x191x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm Maximum value of SAR (interpolated) = 2.21 W/kg Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm Reference Value = 20.81 V/m; Power Drift = -0.07 dB Peak SAR (extrapolated) = 2.84 W/kg SAR(1 g) = 0.678 W/kg; SAR(10 g) = 0.228 W/kg Smallest distance from peaks to all points 3 dB below = 5.8 mm Ratio of SAR at M2 to SAR at M1 = 63.4% Maximum value of SAR (measured) = 1.66 W/kg Communication System: IEEE 802.11ax; Frequency: 6185.000 MHz Medium: HSL_6500_240609 Medium parameters used: f= 6185.000 MHz; σ= 5.76 S/m; ε r = 35.9 Ambient Temperatur…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.41 GHz - 2.46 GHz | 289.10 mW |
Cordless Scanner
Equipment Class
DTS - Digital Transmission SystemCordless Scanner
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterTouch Computer
Equipment Class
CBE - Citizens Band End User DevicesTouch Computer
Equipment Class
NII - Unlicensed National Information Infrastructure TXTouch Computer
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter