Users Manual ZigBee to RS485 Bridge (ZRB2) 1000141 Document Number: 80071 7125 Columbia Gateway Drive, Suite 200 Columbia, MD 21046 CONFIDENTIAL AND PROPRIETARY The information contained in this document is proprietary and confidential information of Autani Corporation. Any use of this information without the expressed written consent of Autani Corporation is prohibited. ZigBee to RS485 Bridge (ZRB2) Users Manual 1. Description CONFIDENTIAL AND PROPRIETARY The information contained in this document is proprietary and confidential information of Autani Corporation. Any use of this information without the expressed written consent of Autani Corporation is prohibited. 2 of 7 Version Date Changed By Revision Description 1 1-11-2011 MEP Preliminary Table of Contents 1. Description ............................................................................................................... 3 2. Ordering Information ............................................................................................... 4 3. Specifications ........................................................................................................... 4 3.1 Absolute Maximum Ratings ........................................................................................................... 4 3.2 Recommended Operating Conditions ........................................................................................... 4 3.3 DC Electrical Specifications .......................................................................................................... 5 3.4 RF Electrical Characteristics ......................................................................................................... 5 4. Physical Interface .................................................................................................... 5 5. Certifications ............................................................................................................ 6 5.1 FCC – United State ....................................................................................................................... 6 5.2 IC – Canada .................................................................................................................................. 6 6. Theory of Operation ................................................................................................. 7 ZigBee to RS485 Bridge (ZRB2) Users Manual 1. Description CONFIDENTIAL AND PROPRIETARY The information contained in this document is proprietary and confidential information of Autani Corporation. Any use of this information without the expressed written consent of Autani Corporation is prohibited. 3 of 7 1. Description The ZigBee to RS485 Bridge (ZRB2) provides a cost-effective path to wirelessly enable many devices which still use wired commutations channels. The wireless side of the ZRB2 employs an RF transceiver in the 2.4 GHz ISM band based on the ZigBee IEEE 802.15.4 wireless network protocol. The wired side of the ZRB2 communicates in RS485 full or half duplex differential modes (i.e. RS485 or RS422). Features • FCC (V8NZRB1000141) and IC (7737A-ZRB1000141) certified • Operational Range: ~1000 feet (LOS) ZigBee to RS485 Bridge (ZRB2) Users Manual 2. Ordering Information CONFIDENTIAL AND PROPRIETARY The information contained in this document is proprietary and confidential information of Autani Corporation. Any use of this information without the expressed written consent of Autani Corporation is prohibited. 4 of 7 2. Ordering Information Part Number Description 1000141-01 ZRB2, Aprilaire 8870 Thermostat Interface Module 1000141-02 ZRB2, Jackson System’s T-32-P Thermostat Interface Module 1000141-03 ZRB2, Point-to-Point Interface Module 1000141-04 ZRB2, RS485 Back Bone Interface Module 1000141-05 ZRB2, National Meter Interface Module 1000141-06 ZRB2, E50C2 Power Meter Interface Module 1000141-07 ZRB2, Pulse Meter Interface Module 1000141-08 ZRB2, Dent Powerscout Meter Interface Module 1000141-09 ZRB2, Wireless ZigBee Router Interface Module 1000141-10 ZRB2, RS-232 Interface Module 3. Specifications 3.1 Absolute Maximum Ratings Note: Exceeding the maximum ratings may cause permanent damage to the unit Parameter Test Condition Min. Max. Unit Input Voltage (Vdd) -150 50 V Voltage on Signal Pin (Rx+, Rx-, Tx+, Tx-) -9 14 V Storage Temperature -25 80 o C 3.2 Recommended Operating Conditions Note: Operating conditions outside those listed here may cause inappropriate and unpredictable behavior. Parameter Test Condition Min. Max. Unit Input Voltage (Vdd) At 25 o 9 C 40 VDC Input Voltage (Vdd) At 25 o 9 C 28 VAC Operating Temperature 0 60 o C ZigBee to RS485 Bridge (ZRB2) Users Manual 4. Physical Interface CONFIDENTIAL AND PROPRIETARY The information contained in this document is proprietary and confidential information of Autani Corporation. Any use of this information without the expressed written consent of Autani Corporation is prohibited. 5 of 7 3.3 DC Electrical Specifications Test conditions unless otherwise specified: at 25 o Parameter C, Vdd = 24VDC, No load on RS485 Bus, LEDs off. Test Condition Typ. Max. Unit Input Current (Idd) 15 60 mA 3.4 RF Electrical Characteristics Parameter Test Condition Min. Typ. Max. Unit Frequency Range At 25 o 2400 C 2500 MHz Maximum Input Signal Strength 0 dBm Relative Frequency Error -120 120 ppm EM250 Tx Power (CH11-CH25) -11 dBm EM250 Tx Power (CH26) -20 dBm 4. Physical Interface All signals are from the perspective of the ZRB2. Wire Number Color Signal Name Description 1 No wire present - Reserved for future feature expansion 2 Red PWR Input power of the ZRB2 3 Blue Rx+ Positive half of the Receiver differential pair 4 White Rx- Negative half of the Receiver differential pair 5 Yellow Tx- Negative half of the Transmitter differential pair 6 Green Tx+ Positive half of the Transmitter differential pair 7 Black GND Input ground and RS485 reference of the ZRB2 8 No wire present - Reserved for future feature expansion Zi…
Text truncated - open the document above for the full version.
7125 Columbia Gateway Drive, Suite 200: Columbia, Maryland 21046 Office: 443.320.2233 Fax: 443.285.0050 www.autani.com REF: 29994EMC-FCC247 To whom it may concern: The ZigBee to RS485 Bridge (ZRB2), is physically too small to support a label indicating the appropriate language as indicated by the FCC. In order to meet this label requirement the language is included in the User’s Manual, ZigBee to RS485 Bridge (ZRB2); document number 80071. It can be found in Section 5 (Certifications), under Note 3. This note is included herein for reference. NOTE 3: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Please contact me if there is any information you may need. Sincerely, Randy Clayton 7125 Columbia Gateway Drive, Suite 200: Columbia, Maryland 21046 Office: 443.320.2233 Fax: 443.285.0050 www.autani.com February 17, 2011 MET Laboratories, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: EMC29994 - FCC Logo Removal from Housing To Whom It May Concern: We have been advised to remove the molded-in FCC logo from the housing for the ZRB2 (1000141) and we plan to have the housing modified to remove this logo. Please contact me if there is any information you may need. Sincerely, Randy Clayton
7125 Columbia Gateway Drive, Suite 200: Columbia, Maryland 21046 Office: 443.320.2233 Fax: 443.285.0050 www.autani.com Long Term Confidentiality Request Letter January 12, 2011 MET Laboratories, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR ZigBee to RS485/RS232 Bridge/Model Number 1000141/FCC ID: V8NZRB1000141 To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the 29994EMC_Block_Diagram.pdf, 29994EMC BOM.xls, 29994EMC_Schematic.pdf, 29994EMC_Theory_of_Operation.pdf, 29994EMC_Config_Signed.pdf required to be submitted with this application be permanently withheld from public review. The above documents are company proprietary information that could never get into the possession of our competition. Please contact me if there is any information you may need. Sincerely, Randy Clayton
Electromagnetic Compatibility Criteria for Intentional Radiators § 15.247(b) RF Exposure RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit Calculation: EUT’s operating frequencies @ 2400-2483.5 MHz; highest conducted power = 18.15dBm (peak) therefore, Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 EUT maximum antenna gain = 5.3 dBi. Equation from page 18 of OET 65, Edition 97-01 S = PG / 4R 2 or R = √PG / 4S where, P = Power Input to antenna (31.62mW) G = Antenna Gain (3.39 numeric) R = 20cm S = 79.43 * 3.39 / 4R 2 (20) 2 S = 0.0536 mW/cm 2
MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ! BALTIMORE, MARYLAND 21230-3432 ! PHONE (410) 354-3300 ! FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408 748-3585 ● FAX (510) 489-6372 The Nation’s First Licensed Nationally Recognized Testing Laboratory February 17, 2011 Autani Corp 7125 Columbia Gateway Drive Columbia, MD 21046 Dear Mark Plasterer, Enclosed is the EMC Wireless test report for compliance testing of the Autani Corp, ZigBee to RS485/RS232 Bridge (ZRB2) as tested to the requirements of Title 47 of the CFR, Ch. 1 (10-1-06 ed.), Part 15, Subpart B, ICES-003, Issue 4 February 2004 for a Class B Digital Device and FCC Part 15 Subpart C, RSS-210, Issue 8, Dec. 2010 for Intentional Radiators. Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or if MET can be of further service to you, please feel free to contact me. Sincerely yours, MET LABORATORIES, INC. Jennifer Warnell Documentation Department Reference: (\Autani Corp\EMC29994-FCC247 Rev. 2) Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. Electromagnetic Compatibility Autani Corp Cover Page ZigBee to RS485/RS232 Bridge (ZRB2) CFR Title 47, Part 15B, 15.247; RSS-210, Issue 8, Dec. 2010 & ICES-003 MET Report: EMC29994-FCC247 Rev. 2 © 2011, MET Laboratories, Inc. Page ii of viii DOC-EMC702 6/18/2009 Electromagnetic Compatibility Criteria Test Report for the Autani Corp ZigBee to RS485/RS232 Bridge (ZRB2) Tested under the FCC Certification Rules contained in Title 47 of the CFR, Parts 15 Subpart B & ICES-003 for Class B Digital Devices & 15.247 Subpart C & RSS-210, Issue 8, Dec. 2010 for Intentional Radiators MET Report: EMC29994-FCC247 Rev. 2 February 17, 2011 Prepared For: Autani Corp 7125 Columbia Gateway Drive Columbia, MD 21046 Prepared By: MET Laboratories, Inc. 914 W. Patapsco Ave Baltimore, MD 21230 Electromagnetic Compatibility Autani Corp Cover Page ZigBee to RS485/RS232 Bridge (ZRB2) CFR Title 47, Part 15B, 15.247; RSS-210, Issue 8, Dec. 2010 & ICES-003 MET Report: EMC29994-FCC247 Rev. 2 © 2011, MET Laboratories, Inc. Page iii of viii DOC-EMC702 6/18/2009 Electromagnetic Compatibility Criteria Test Report for the Autani Corp ZigBee to RS485/RS232 Bridge (ZRB2) Tested under the FCC Certification Rules contained in Title 47 of the CFR, Parts 15 Subpart B & ICES-003 for Class B Digital Devices & 15.247 Subpart C & RSS-210, Issue 8, Dec. 2010 for Intentional Radiators Len Knight, Project Engineer Jennifer Warnell Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of the FCC Rules Parts 15B, 15.247 and Industry Canada standards ICES-003, Issue 4 February 2004, RSS-210, Issue 8, Dec. 2010 under normal use and maintenance. Shawn McMillen, Wireless Manager, Electromagnetic Compatibility Lab Electromagnetic Compatibility Autani Corp Report Status ZigBee to RS485/RS232 Bridge (ZRB2) CFR Title 47, Part 15B, 15.247; RSS-210, Issue 8, Dec. 2010 & ICES-003 MET Report: EMC29994-FCC247 Rev. 2 © 2011, MET Laboratories, Inc. Page iv of viii DOC-EMC702 6/18/2009 Report Status Sheet Revision Report Date Reason for Revision January 19, 2011 Initial Issue. 1 February 11, 2011 Revised per engineer corrections. 2 February 17, 2011 Editorial corrections. Electromagnetic Compatibility Autani Corp Table of Contents ZigBee to RS485/RS232 Bridge (ZRB2) CFR Title 47, Part 15B, 15.247; RSS-210, Issue 8, Dec. 2010 & ICES-003 MET Report: EMC29994-FCC247 Rev. 2 © 2011, MET Laboratories, Inc. Page v of viii DOC-EMC702 6/18/2009 Table of Contents I. Executive Summary ................................................................................................................................................. 1 A. Purpose of Test ................................................................................................................................................... 2 B. Executive Summary ............................................................................................................................................ 2 II. Equipment Configuration ....................................................................................................................................... 3 A. Overview ............................................................................................................................................................. 4 B. References ........................................................................................................................................................... 5 C. Test Site .............................................................................................................................................................. 5 D. Description of Test Sample ................................................................................................................................. 6 E. Equipment Configuration .................................................................................................................................... 7 F. Support Equipment ............................................................................................................................................. 7 G. Ports and Cabling Information .........................…
Text truncated - open the document above for the full version.
Photograph 1. Radiated Spurious Test Setup Photograph 2. CEV Test Setup Photograph 3. RE Test Setup, RS232 Photograph 4. RE Test Setup, RS485
7125 Columbia Gateway Drive · Columbia, Maryland · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 79.43 mW |

Wireless bridge
Equipment Class
DTS - Digital Transmission System
Zigbee transceiver
Equipment Class
DTS - Digital Transmission System
ZigBee to RS485 Bridge (ZRB)
Equipment Class
DTS - Digital Transmission System