FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Autani, LLC/
  3. V8NZRB1000152

V8NZRB1000152Wireless bridge

Autani, LLC
Wireless bridge - FCC ID V8NZRB1000152 - Autani, LLC
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 22, 2014
Application Purpose
Original Equipment
Date of Application
Jan 22, 2014
Equipment Note
Wireless bridge
Frequency Range
2405.00000000 - 2475.00000000
Company
Autani, LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User’s Manual ZigBee to RS485 Bridge (ZRB3) 1000152 Document Number: 80252 7170 Riverwood Drive, Suite B Columbia, MD 21046 CONFIDENTIAL AND PROPRIETARY The information contained in this document is proprietary and confidential information of Autani Corporation. Any use of this information without the expressed written consent of Autani Corporation is prohibited. ZigBee to RS485 Bridge (ZRB3) User’s Manual 1. Description CONFIDENTIAL AND PROPRIETARY The information contained in this document is proprietary and confidential information of Autani Corporation. Any use of this information without the expressed written consent of Autani Corporation is prohibited. 2 of 12 Version Date Changed By Revision Description 1 10-15-2013 MEP Preliminary Table of Contents 1. Description ............................................................................................................... 3 2. Ordering Information ............................................................................................... 4 3. Specifications........................................................................................................... 5 3.1 Absolute Maximum Ratings ........................................................................................................... 5 3.2 Recommended Operating Conditions ........................................................................................... 5 3.3 DC Electrical Specifications .......................................................................................................... 5 3.4 RF Electrical Characteristics ......................................................................................................... 5 4. Physical Interface .................................................................................................... 6 5. Certifications ............................................................................................................ 7 5.1 FCC – United States ...................................................................................................................... 7 5.2 IC – Canada .................................................................................................................................. 7 6. Typical Applications ................................................................................................ 8 6.1 Network Mode ............................................................................................................................... 9 6.2 LED and Pushbutton Switch Functions ....................................................................................... 10 7. Mechanical Details ................................................................................................. 11 8. Appendix A: Installation Instructions .................................................................. 12 ZigBee to RS485 Bridge (ZRB3) User’s Manual 1. Description CONFIDENTIAL AND PROPRIETARY The information contained in this document is proprietary and confidential information of Autani Corporation. Any use of this information without the expressed written consent of Autani Corporation is prohibited. 3 of 12 1. Description The ZigBee to RS485 Bridge (ZRB3) provides a cost-effective path to wirelessly enable many devices which still use wired commutations channels. The wireless side of the ZRB3 employs an RF transceiver in the 2.4 GHz ISM band based on the ZigBee IEEE 802.15.4 wireless network protocol. The wired side of the ZRB3 communicates in RS485 full or half duplex differential modes (i.e. RS485 or RS422). Features  FCC and IC Certified...... (Pending)  Operational Range: ~1000 feet (LOS)  Made in USA ZigBee to RS485 Bridge (ZRB3) User’s Manual 2. Ordering Information CONFIDENTIAL AND PROPRIETARY The information contained in this document is proprietary and confidential information of Autani Corporation. Any use of this information without the expressed written consent of Autani Corporation is prohibited. 4 of 12 2. Ordering Information Part Number Description 1000141-01 ZRB3, Aprilaire 8870 Thermostat Interface Module 1000141-02 ZRB3, Jackson System’s T-32-P Thermostat Interface Module 1000141-03 ZRB3, Point-to-Point Interface Module 1000141-04 ZRB3, RS485 Back Bone Interface Module 1000141-05 ZRB3, National Meter Interface Module 1000141-06 ZRB3, E50C2 Power Meter Interface Module 1000141-07 ZRB3, Pulse Meter Interface Module 1000141-08 ZRB3, Dent Powerscout Meter Interface Module 1000141-09 ZRB3, Wireless ZigBee Router Interface Module 1000141-10 ZRB3, RS-232 Interface Module 1000152-11 Reserved 1000152-12 Reserved 1000152-13 ZRB3, DTS SMX Meter 1000152-14 ZRB3, Barix R6 1000152-15 ZRB3, Wi5 Point-to-Point RS232 Node 1000152-16 ZRB3, Wi5 Point-to-Point RS232 Master Node 1000152-17 ZRB3, Dry Contact 1000152-18 ZRB3, Wi5 Point-to-Point RS232 Slave Node 1000152-19 ZRB3, Intermatic 8415 1000152-20 ZRB3, SMT-131 (Hotel Stat) 1000152-21 ZRB3, Relay Board 1000152-22 ZRB3, LVRC Board ZigBee to RS485 Bridge (ZRB3) User’s Manual 3. Specifications CONFIDENTIAL AND PROPRIETARY The information contained in this document is proprietary and confidential information of Autani Corporation. Any use of this information without the expressed written consent of Autani Corporation is prohibited. 5 of 12 3. Specifications 3.1 Absolute Maximum Ratings Note: Exceeding the maximum ratings may cause permanent damage to the unit Parameter Test Condition Min. Max. Unit Input Voltage (Vdd) -50 50 V Voltage on Signal Pin (Rx+, Rx-, Tx+, Tx-) -9 14 V Storage Temperature -25 70 o C 3.2 Recommended Operating Conditions Note: Operating conditions outside those listed here may cause inappropriate and unpredictable behavior. Parameter Test Condition Min. Max. Unit Input Voltage (Vdd) 25 o C 12 30 VDC Input Voltage (Vdd) 25 o C 9 24 VAC Operating Temperature 0 60 o C 3.3 DC Electrical Specifications Test conditions unless otherwise specified: 25 o C, Vdd = 24VDC, No load on RS485 Bus, LEDs…

Text truncated - open the document above for the full version.

Cover Letter(s)

,mw&mmK Autornatinq¡ üreen Long Term Confidcntiality Requcst Lettcr January 22,2014 MllT Labolatories, Inc. 914 West Patapsco Avenue Baltirnore, MD 21230 RE: CONFIDENTIALITY REQUìjST FOR autaniNct to RS485/RS232 Bridec/Modct Numbcr 1000152/l'CC ID: V8NZRB1000l52 To Whom It May Concern: This letter serves as an official requesl for confidentiality under sections 0.457 and,0.459 of Cl'l{ 47. We have requested that the 406I8EMC Block Diasram.ndf, 40618DMC BOM.xls, 40618EMC Schematic.pdf, 40618EMC Theorv of Oneration.pdf lequiled to be submilted with this application be pcura!ç4lLwithheld fi.om public review.The abovc documcnts are comÞany proDrictary information that could never qct into the ¡rossession of our comÞctition. Please oontact me if there is any information you may need. S ince¡ely-,- 7 ,/ ( 1 ' ::::t' \' " .inunoy ôt*øi7 '). ,( / '/ /',-" ''/ .t . .)_- .,t/ .;:.-- --,, 7170 Riverwood Dr¡ve, Su¡te B; Columbia, N4aryland 21046 Office: 443.320.2233 Fax: 443.285.0050 www.autani.com

Cover Letter(s)

] mruftæmffi *-*g Ar.rtrrrrralirrr¡ (,r er. Short Tcrm Confidentiality Requcst Lettcr January 22,21)74 MET Laboratories, iuc. 914 West Patapsco Avenue Baltinrore, MD 21230 RE: Shorl Tern Confidentiality Request Fo| autaniNct to RS48 Number 1000152. FCC ID: V8NZ'RB1000152 To Whorn lt May Concern: Itr accordance with sections 0.457 and 0.459 of CFR 47, Autani Corporafion requests sholl-telm Confidentiality of following sections of lhis application for a period of45 days after grant is issued. Test setup photos External photos Internal photos User's manual These docunents contain detailed system and equipment descriptions and related information aboul the product, which Autani Corporation considers to be proprietary, confidential, and a oustom design and otherwise, would no1 r'elease 1o the general public. Since this design is a basis from which fi¡1r¡re technological products will evolve, Autani Corporation feels that this information would be of beneht to its cornpetitol's, ancl thal the disclosure of the information in these doouments woulcl give oul competitors an unfair advantage in the lnarket. Please contact me if there is any inl'orn-ratior.r you rlay need. S incc rc ly. .// /( ( ,/ " ,' . '\, 2 ) --) / la' ¡-' Randy Claylon 7170 Riverwood Drive, Suite B; Columbra, ¡4aryland 21046 Office: 443.32O.2233 Fax ; 443, 285.0050 www,autani,com

Cover Letter(s)

] mwffmmffi =*-/ Aulomatinq Crr,cn Jannary 13, 2014 Dear Application Examiner, Autani Corpolation, model: 1000152, FCC ID: V8N2R81000152), woutd like to have your aulhorization as a modular approval specil'ic to the ZRB3 Module. The requirements ofPublic Nolice DA00-1407 have been met and shown on the lollowing statements. 1. "Thc modular transmitter rnust havc its own IIF shielding.": The ZRIì3 Module contains a shield that covcr thc RF circuitry. 2. "Thc modular transmitter must have buffercd modulation/data inputs.": Thc ZRB3 Module contains buffcred modulation/data inputs. 3. "The modular transmittcr musf havc its own power supply regulation.": The ZRB3 Module contains an on-board power supply/regulator. 4. 'oThc modular trânsmitter must comply with thc antenna requiremcnts of section 15.203 and 75.204(C).": The ZRB3 Modules uses a folded F-antenna which is a fabricated part of thc arhvork/etch on thc printcd circuit board. 5. "The modular transmittcr must bc tcstcd in a stand-alone confïguration": Thc ZRB3 Modulc has bcen tcstcd in a stand-alone configuration. 6. "The modular transmittor must be labclcd with its own FCC ll) number.,': Tho Zl{l}3 Modulc will be labeled with its own FCC Il) number. 7. "Thc modular transmittcr must comply with any spccific rulc or operating requirements applicablc t<¡ thc transmitfcr and thc manufacturer must providc adequatc instructions along with the modulc to cxplain any such requircmcnts.,': The Zlì83 Modulc has been testcd to comply. 8. "The modular transmitfcr must comply with any applicablc llF cxposurc requiremcnfs.": Thc ZlLlì3 Module has be en tcstcd to comply. Please contact me if you have any furlher questions. .*1 nseu.d{ tf' ¡-¿ - /r/ /?'C ")/ (andi ctau6ø ' " a:

ID Label/Location Info

7170 Riverwood Drive, Suite B; Columbia, Maryland 21046 Office: 443.320.2233 Fax: 443.285.0050 www.autani.com REF: 40618EMC-FCC247 January 13, 2014 MET Laboratories, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 Below is the FCC/IC Label for the ZRB3 Module.

ID Label/Location Info

-.\L H Þ \ ffiffiKffiffiruffi ..-# AuLcinratirrr,, Crelt-,r'r REF: 406188MC-FCC247 January 13,2014 MET Laboratories, Inc. 914 West Patapsco Avenue Bahinrore, MD 21230 To whom it may concem: The ZigBee to llS485 Bridge (ZRB3), is physically too small 10 support a label indicating the appropriate language as indicated by the FCC. In order to meet this label requirement the langr.rage is included in the User''s Manual. It can be found in Section 5 (Certifications), Note 3. This note is included herein for reference. NOTE 3: This device complies wilh parl l5 of the FCC Rules. Operation is subject to the following two conditions: (1) This device rrray not cause harmful intelference, and (2) this device must accept any interference received, including intelference that may cause undesired operation. Please contact rne if there is any information you may neecl. 7170 R¡verwood Drive, Suite B; Columb¡a, fvlaryland 21046 Oftice: 443.32O.2233 Fax: 443.285.0050 www.autani.com

RF Exposure Info

L-COM, INC. 45 BEECHWOOD DRIVE NORTH ANDOVER, MA 01845 WWW.L-COM.COM E-MAIL: [email protected] PHONE: 1-800-343-1455 FAX: 1-978-689-9484 © L-com, Inc. All Rights Reserved. L-com Global Connectivity and the L-com logo are registered marks. HyperLink Wireless 2.4 GHz 2.2 dBi Model: HG2402RD-RSF “Rubber Duck” Antenna Applications • Compact size, only 4.13” long • Tilt and Swivel design • RP-SMA Connector Features • 802.11b/g/n • OEM Replacement Antenna • 2.4GHz ISM Band Description This compact 2.4GHz omnidirectional "rubber-duck" WiFi antenna provides broad coverage and 2.2 dBi gain. It is a coaxial sleeve design with an omni-directional pattern. It is ideally suited for IEEE 802.11b and 802.11g wireless LANs, Bluetooth® and other WLAN applications. Only 4.13" long, this flexible antenna features a tilt-and-swivel reverse-polarity SMA plug connector, allowing them to be used vertically, at a right angle, or any angle in-between. It is suitable as a replacement antenna for many access points and radios that are equipped with reverse-polarity SMA connectors including D-Link®, Linksys® WET11 and others (Note: This RF antenna is used as a "replacement" antenna rather than a "range extender" antenna. It should yield similar range to most radio's stock antennas). Application Note: This antenna is not for use with U.S. Robotics® RP-SMA equipped devices. Specifications Mechanical Specifications Weight 0.52 oz. (15 g) Length 4.13" (105 mm) Diameter 0.4" (10 mm) Finish Matte Black Connector Reverse Polarity SMA Plug Operating Temperature -40° C to 85° C (-40° F to 185° F) Polarization Vertical RoHS Compliant Yes Electrical Specifications Weight 0.52 oz. (15 g) Length 4.13" (105 mm) Diameter 0.4" (10 mm) Finish Matte Black L-COM, INC. 45 BEECHWOOD DRIVE NORTH ANDOVER, MA 01845 WWW.L-COM.COM E-MAIL: [email protected] PHONE: 1-800-343-1455 FAX: 1-978-689-9484 © L-com, Inc. All Rights Reserved. L-com Global Connectivity and the L-com logo are registered marks. Antenna Gain Pattern

RF Exposure Info

§ 15.247(i) Maximum Permissible Exposure RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit Calculation: EUT’s operating frequencies @ 2400-2483.5 MHz; highest conducted power = 24.04 dBm (peak) therefore, Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 EUT maximum antenna gain = 2 dBi. Equation from page 18 of OET 65, Edition 97-01 S = PG / 4R 2 or R = √PG / 4S where, P = Power Input to antenna (253.5 mW) G = Antenna Gain (1.58 numeric) R = 20cm S = 253.5 * 1.58 / 4 (20) 2 S = 0.08 mW/cm 2 Therefore, the uncontrolled exposure limit is met at 20cm.

Test Report

MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE • BALTIMORE, MARYLAND 21230-3432 • PHONE (410) 354-3300 • FAX (410) 354-3313 33439 WESTERN AVENUE • UNION CITY, CALIFORNIA 94587 • PHONE (510) 489-6300 • FAX (510) 489-6372 3162 BELICK STREET • SANTA CLARA, CA 95054 • PHONE (408) 748-3585 • FAX (510) 489-6372 13301 MCCALLEN PASS • AUSTIN, TEXAS 78753 • PHONE (512) 287-2500 • FAX (512) 287-2513 The Nation’s First Licensed Nationally Recognized Testing Laboratory January 21, 2014 Autani Corp. 7170 Riverwood Drive, Suite B Columbia, MD 21046 Dear Mark Plasterer, Enclosed is the EMC Wireless test report for compliance testing of the Autani Corp., ZRB3 as tested to the requirements of Title 47 of the CFR, Ch. 1 (10-1-06 ed.), Part 15, Subpart B and ICES-003, Issue 5 August 2012 for a Class B Digital Device, and FCC Part 15 Subpart C and RSS-210, Issue 8, Dec. 2010 for Intentional Radiators. Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or if MET can be of further service to you, please feel free to contact me. Sincerely yours, MET LABORATORIES, INC. Jennifer Warnell Documentation Department Reference: (\Autani Corp.\EMC40618-FCC247 Rev. 1) Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. Electromagnetic Compatibility Autani Corp. Cover Page ZRB3 CFR Title 47, Part 15B, 15.247; RSS-210, Issue 8, Dec. 2010 & ICES-003 MET Report: EMC40618-FCC247 Rev. 1 © 2014, MET Laboratories, Inc. Page ii of viii DOC-EMC702 6/18/2009 Electromagnetic Compatibility Criteria Test Report for the Autani Corp. ZRB3 Tested under the FCC Certification Rules contained in Title 47 of the CFR, Parts 15 Subpart B & ICES-003 for Class B Digital Devices & 15.247 Subpart C & RSS-210, Issue 8, Dec. 2010 for Intentional Radiators MET Report: EMC40618-FCC247 Rev. 1 January 21, 2014 Prepared For: Autani Corp. 7170 Riverwood Drive, Suite B Columbia, MD 21046 Prepared By: MET Laboratories, Inc. 914 W. Patapsco Ave Baltimore, MD 21230 Electromagnetic Compatibility Autani Corp. Cover Page ZRB3 CFR Title 47, Part 15B, 15.247; RSS-210, Issue 8, Dec. 2010 & ICES-003 MET Report: EMC40618-FCC247 Rev. 1 © 2014, MET Laboratories, Inc. Page iii of viii DOC-EMC702 6/18/2009 Electromagnetic Compatibility Criteria Test Report for the Autani Corp. ZRB3 Tested under the FCC Certification Rules contained in Title 47 of the CFR, Parts 15 Subpart B & ICES-003 for Class B Digital Devices & 15.247 Subpart C & RSS-210, Issue 8, Dec. 2010 for Intentional Radiators Shawn McMillen, Project Engineer Jennifer Warnell Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of the FCC Rules Parts 15B, 15.247 and Industry Canada standards ICES-003, Issue 5 August 2012, RSS-210, Issue 8, Dec. 2010 under normal use and maintenance. Asad Bajwa, Director, Electromagnetic Compatibility Lab Electromagnetic Compatibility Autani Corp. Report Status ZRB3 CFR Title 47, Part 15B, 15.247; RSS-210, Issue 8, Dec. 2010 & ICES-003 MET Report: EMC40618-FCC247 Rev. 1 © 2014, MET Laboratories, Inc. Page iv of viii DOC-EMC702 6/18/2009 Report Status Sheet Revision Report Date Reason for Revision  January 16, 2014 Initial Issue. 1 January 21, 2014 Editorial correction. Electromagnetic Compatibility Autani Corp. Table of Contents ZRB3 CFR Title 47, Part 15B, 15.247; RSS-210, Issue 8, Dec. 2010 & ICES-003 MET Report: EMC40618-FCC247 Rev. 1 © 2014, MET Laboratories, Inc. Page v of viii DOC-EMC702 6/18/2009 Table of Contents I. Executive Summary ................................................................................................................................................. 1 A. Purpose of Test ................................................................................................................................................... 2 B. Executive Summary ............................................................................................................................................ 2 II. Equipment Configuration ....................................................................................................................................... 3 A. Overview ............................................................................................................................................................. 4 B. References ........................................................................................................................................................... 5 C. Test Site .............................................................................................................................................................. 5 D. Description of Test Sample ................................................................................................................................. 6 E. Equipment Configuration .................................................................................................................................... 7 F. Support Equipment ............................................................................................................................................. 7 G. Ports and Cabling Information ............................................................................................................................ 7 H. Mode of Operation ................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Photograph 1. Conducted Emissions, Test Setup Photograph 2. Radiated Emissions, Test Setup Photograph 3. Conducted Emissions, 15.207(a), Test Setup Photograph 4. Radiated Spurious Emissions, Test Setup, Integral Antenna, 1 GHz – 18 GHz at 0.5m Distance Photograph 5. Radiated Spurious Emissions, Test Setup, Integral Antenna, 1 GHz – 18 GHz at 1.0m Distance Photograph 6. Radiated Spurious Emissions, Test Setup, External Whip Antenna, 1 GHz – 18 GHz at 0.5m Distance Photograph 7. Radiated Spurious Emissions, Test Setup, External Whip Antenna, 1 GHz – 18 GHz at 1.0m Distance

Contact Information

Applicant

Scott Metker(Chief Operating Officer)
[email protected]443-320-2233Fax: 443-285-0050

Technical Contact

Autani CorporationMark Plasterer
[email protected]443-320-2233

7170 Riverwood Drive · Columbia, Maryland · United States

Test Firm

EUROFINS ELECTRICAL AND ELECTRONIC TESTING NA, INCGreg Kovolenko
[email protected]4108444071Fax: 4103543313

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz254.00 mW
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Modular approval. Power listed is conducted. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance to FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Autani, LLC

Zigbee transceiver - FCC ID V8NWAT1000142 - Autani, LLC
V8NWAT1000142

Zigbee transceiver

May 26, 2011

Equipment Class

DTS - Digital Transmission System
ZigBee to RS485 Bridge - FCC ID V8NZRB1000141 - Autani, LLC
V8NZRB1000141

ZigBee to RS485 Bridge

Feb 17, 2011

Equipment Class

DTS - Digital Transmission System
ZigBee to RS485 Bridge (ZRB) - FCC ID V8NZRB1000127 - Autani, LLC
V8NZRB1000127

ZigBee to RS485 Bridge (ZRB)

Dec 15, 2009

Equipment Class

DTS - Digital Transmission System