
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
EMW200R-UL+EMW203T (E).doc, P1/2 Instruction Manual for RF Remote Socket and Transmitter Ref: EMW200R-UL + EMW203T Function 1. The remote control socket turns on and off the appliance by a wireless transmitter using radio frequency up to 25 meters away. 2. It is ideal for controlling appliance for the purposes of home automation and energy saving. 3. Each transmitter controls up to 3 channels. Each channel can command up to 3 receivers. Operation 1. Check the group setting at the back of the transmitter, A, B, C or D. If the transmitter is in group A, then, the commanded receiver has to be in the same group setting. 2. Check the group setting at the back of the receiver is same as transmitter and the channel no, eg. A1, A2 or A3 3. Connect the remote control socket to the mains power supply. 4. Press the corresponding “ON”, “OFF” buttons on the transmitter to switch on and off the connected appliance by remote control. (eg. on/off buttons 1 controls receiver A1, 2 controls receiver A2, 3 controls A3) 5. The indicator on the receiver blink once for every reception of power on/off Caution 1. For safety reason, always switch off your appliance before connection and avoid setting up on rainy days. 2. Appliances to be connected to the remote control socket MUST NOT exceed the voltage and frequency ratings as in “Specifications”. 3. To adjust the channel or the groups, always use a big screw driver with the same diameter as the adjustment arrow at the back of the socket and receiver. A small screw driver will deform the plastic housing during adjustment. Specifications EMW200R-UL, 1. Power Rating : 125V~, 60Hz, 1000W 2. Frequency: : 433.92 MHz 3. Distance: : 25 meters EMW203T Battery : CR2032 Frequency : 433.92 MHz 1. Distance : 25 meters max. Holder: Everflourish Electrical Co., Ltd. Renjiu Village, Wuxiang Town, Yinzhou, Ningbo, 315111 P.R. China EMW200R-UL+EMW203T (E).doc, P2/2 Caution: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Prudence : Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. Warning: Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Avertissement : Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante
022311 – 6 Request for Confidentiality Date: __ July 9,2013 Subject: Confidentiality Request for: _FCC-IC:VBA-EF203T FCC-ID:7098A-EF203T_____ Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Permanent* 2 Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term Permanent* User’s Manual *Note: ______(Insert Explanation as Necessary)______ ____Everflourish Electrical Co.,Ltd ____ has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of ___(specify number of days not to exceed 180 ) 3 ___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: The applicant understands that until such time that IC distinguishes between Short Term and Permanent Confidentiality, either type of marked exhibit above will simply be marked Confidential when submitted to IC. Sincerely, By: Lisa Luo (Signature/Title 4 ) (Print name) 2 - The asterisked items (*) require further justification before permanent confidentiality will be allowed. These also currently require review by the FCC under their Permit-But-Ask policy before the grant is issued and can delay completion of an application. Further justification should be added to the note above. One such example for a potted device would be: “The EUT is FULLY potted using a non-removable epoxy based material. Removal of potting material causes irreparable damage to internal circuitry. See photographs exhibits that outline the device before and after potting.” 3 - Please refer to http://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details. 4 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.
022311 – 6 Authority to Act as Agent Date: __July 9,2013______ American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: ______Intertek Shanghai_____ is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Expiration Date: ____Dec 30, 2013____ By: ______ __ _______Lisa Luo______________ (Signature 1 ) (Print name) Title: _____Certificate Engineer _____________________ On behalf of: ______Everflourish Electrical Co.,Ltd ___________ (Company Name) Telephone: ____86 574 88330888______________
FCC ID:VBA- EF203T IC:7098A- EF203T Page 1 of 2 External Picture FCC ID:VBA- EF203T IC:7098A- EF203T Page 2 of 2
Note: the label would be stamped or silkscreened on the EUT.
FCC ID: VBA-EF203T IC: 7098A-EF203T Page 1 of 3 Internal Picture FCC ID: VBA-EF203T IC: 7098A-EF203T Page 2 of 3 FCC ID: VBA-EF203T IC: 7098A-EF203T Page 3 of 3
FCC ID: VBA-EF203T IC: 7098A-EF203T Page 2 of 20 Description of Test Facility Name: Intertek Testing Services Limited Shanghai Address: Building No.86, 1198 Qinzhou Road(North), Shanghai 200233, P.R. China FCC Registration Number: 236597 IC Assigned Code: 2042B-1 Name of contact: Steve Li Tel: +86 21 64956565 ext. 214 Fax: +86 21 54262335 ext. 214 FCC ID: VBA-EF203T IC: 7098A-EF203T Page 3 of 20 Content SUMMARY .......................................................................................................................................................... 1 DESCRIPTION OF TEST FACILITY ......................................................................................................................... 2 1. GENERAL INFORMATION ............................................................................................................................ 4 1.1 Applicant Information ..................................................................................................... 4 1.2 Identification of the EUT ................................................................................................ 4 1.3 Technical specification ................................................................................................... 5 1.4 Mode of operation during the test / Test peripherals used .............................................. 5 2. TEST SPECIFICATION .................................................................................................................................. 6 2.1 Instrument list ................................................................................................................. 6 2.2 Test Standard .................................................................................................................. 6 3. FUNDAMENTAL & SPURIOUS EMISSION & RESTRICT BAND RADIATED EMISSION ................................... 8 3.1 Test limit ......................................................................................................................... 8 3.2 Test Configuration .......................................................................................................... 9 3.3 Test procedure and test setup .......................................................................................... 9 3.4 Test protocol ................................................................................................................. 10 4. DEACTIVATING TIME ................................................................................................................................ 12 4.1 Test limit ....................................................................................................................... 12 4.2 Test Configuration ........................................................................................................ 13 4.3 Test procedure and test setup ........................................................................................ 13 4.4 Test protocol ................................................................................................................. 13 5. POWER LINE CONDUCTED EMISSION ........................................................................................................ 14 5.1 Limit .............................................................................................................................. 14 5.2 Test configuration ......................................................................................................... 14 5.3 Test procedure and test set up ....................................................................................... 15 5.4 Test protocol ................................................................................................................. 16 6. EMISSION BANDWIDTH ............................................................................................................................. 17 6.1 Test limit ....................................................................................................................... 17 6.2 Test Configuration ........................................................................................................ 17 6.3 Test procedure and test setup ........................................................................................ 17 6.4 Test protocol ................................................................................................................. 18 7. OCCUPIED BANDWIDTH ............................................................................................................................ 19 7.1 Test limit ....................................................................................................................... 19 7.2 Test Configuration ........................................................................................................ 19 7.3 Test procedure and test setup ........................................................................................ 19 7.4 Test protocol ................................................................................................................. 20 FCC ID: VBA-EF203T IC: 7098A-EF203T Page 4 of 20 1. General Information 1.1 Applicant Information Applicant: Everflourish Electrical Co.,Ltd. Renjiu Village, Wuxiang Town, Yinzhou, Ningbo 315111, China Name of contact: Selina Dong Tel: 86 574 88330888*8294 Fax: 86 574 88330999 Manufacturer: Everflourish Electrical Co.,Ltd. Renjiu Village, Wuxiang Town, Yinzhou, Ningbo 315111, China Sample received date : Jun 24, 2013 Sample Identification No : *0130621-46-003* Date of test : Jun 27, 2012 ~ July 10, 2012 1.2 Identification of the EUT Equipment: Remote control transmitter Type/model: EMW203T FCC ID: VBA- EF203T IC: 7098A-EF203T FCC ID: VBA-EF203T IC: 7098A-EF203T Page 5 of 20 1.3 Technical specification Operation Frequency Band: 433.92MHz Modulation: ASK Antenna Designation: Integral antenna, non-user removable. Gain of Antenna: 1.…
Text truncated - open the document above for the full version.
FCC ID: VBA-EF300TK IC: 7098A-EF300TK Page 1 of 12 Test Data FCC ID: VBA-EF300TK IC: 7098A-EF300TK Page 2 of 12 1. Fundamental & Spurious Emission & Restrict band radiated emission Horizontal 30-1000MHz FCC ID: VBA-EF300TK IC: 7098A-EF300TK Page 3 of 12 Vertical 30-1000MHz FCC ID: VBA-EF300TK IC: 7098A-EF300TK Page 4 of 12 Vertical 1000-5000MHz FCC ID: VBA-EF300TK IC: 7098A-EF300TK Page 5 of 12 Horizontal 1000-5000 MHz FCC ID: VBA-EF300TK IC: 7098A-EF300TK Page 6 of 12 Horizontal Restrict band FCC ID: VBA-EF300TK IC: 7098A-EF300TK Page 7 of 12 2. Deactivating time FCC ID: VBA-EF300TK IC: 7098A-EF300TK Page 8 of 12 3. Emission bandwidth FCC ID: VBA-EF300TK IC: 7098A-EF300TK Page 9 of 12 4. Occupied bandwidth FCC ID: VBA-EF300TK IC: 7098A-EF300TK Page 10 of 12 5. Duty Cycle FCC ID: VBA-EF300TK IC: 7098A-EF300TK Page 11 of 12 FCC ID: VBA-EF300TK IC: 7098A-EF300TK Page 12 of 12 All the keys were assessed and the test data with maximum duty cycle was listed above. The worst Duty cycle= (11*0.98+ 14*0.41) / 42.09 = 0.39
FCC ID: VBA-EF300TK IC: 7098A-EF300TK Page 1 of 4 Test Setup FCC ID: VBA-EF300TK IC: 7098A-EF300TK Page 2 of 4 1. Radiated Emission 30MHz-1000MHz, X axis 30MHz-1000MHz, Y axis FCC ID: VBA-EF300TK IC: 7098A-EF300TK Page 3 of 4 30MHz-1000MHz, Z axis Higher than 1GHz, X axis FCC ID: VBA-EF300TK IC: 7098A-EF300TK Page 4 of 4 Higher than 1GHz, Y axis Higher than 1GHz, Z axis
Building No.86, 1198 Qinzhou Road(North) · Shanghai · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.93 MHz | - |

Cord extension set
Equipment Class
8CC - Part 18 Consumer Device
Wireless Doorbell
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Control Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Control Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
EMW203T1
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter