VBNFZHE-01Flexi Multiradio 10 BTS, RF module 2.6GHz, TDD

Nokia Solutions and Networks
Flexi Multiradio 10 BTS, RF module 2.6GHz, TDD - FCC ID VBNFZHE-01 - Nokia Solutions and Networks
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Aug 05, 2013
Application Purpose
Original Equipment
Date of Application
Aug 05, 2013
Equipment Note
Flexi Multiradio 10 BTS, RF module 2.6GHz, TDD
Frequency Range
2506.00000000 - 2680.00000000
Company
Nokia Solutions and Networks
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Flexi Multiradio BTS Quick Guide Cabling Cabling 8 Internal power cabling Antenna cabling Transmission cabling Optical cabling Check the installation Installation check list 11 Front covers 10 Front covers Installation Installing the plinth 4 Plinth on the floor Adapter mechanics Plinth on the wall Plinth on the pole Installation Installing the modules 7 Principle of module installation Recommended installation order Installation Installing the transmission sub-module and power feed 6 Installing the transmission sub-module DC power cable This guide can be used as quick reference for Flexi Multiradio BTS installation. Flexi Multiradio BTS is a macro BTS site solution. It consists of one System Module with a transmission sub-module and RF Modules. It can be installed stacked on the floor, or mounted on the wall or on the pole. This quick guide is for basic stand-alone installation only. For other installation options, see operating docume ntation. Ground the BTS Grounding principle 5 Grounding principle of the BTS Check the delivery 1 Contents of delivery Preparing modules for installation Back cover and cable entries Prepare the installation 3 2 Clearances Check the site Minimum clearances Powering up and commissioning the BTS 9 Power up and commission BTS Warning Invisible laser radiation from the module optical fibre connector. Always switch off the laser before detaching the optical fibre from the connector. Caution Incorrect cables and seals may not provide secured weather protection. In outdoor installations, including the outdoor cabinet, use only tested IP55 class outdoor cables with seals provided by Nokia Siem ens Networks. This is also recommended for indoor installations. Electrostatic discharge (ESD) may dam age the modules. Wear an ESD wrist strap or use a corresponding method when handling the modules. The p linth rear stopper is fragile. Do not attempt to lift the plinth using the rear stopper. The information in this document is subject to change without notice and describes only the product de fined in the introduction of this documentation. This document is not an official customer document an d Nokia Siemens Networks does not take responsibility for any errors or omissions in this document. Th is document is intended for the use of Nokia Siemens Networks customers only for the purposes of the a greement under which the document is submitted. No part of this documentation may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Ne tworks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer c omments as part of the process of continuous development and improvement of the documentation. The info rmation or statements given in this documentation concerning the suitability, capacity or performance of the mentioned hardware or software products are given “as is” and all liability arising in connecti on with such hardware or software products shall be defined conclusively and finally in a separate agr eement between Nokia Siemens Networks and the customer. IN NO EVENT WILL Nokia Siemens Networks BE LIA BLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE , BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA, that might arise from the use of this document or the information in it. THE CONTENTS OF THIS DOCUMENT ARE PROVIDED "AS IS". EXCEPT AS REQUIRED BY APP LICABLE MANDATORY LAW, NO WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITE D TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT , ARE MADE IN RELATION TO THE ACCURACY, RELIABILITY OR CONTENTS OF THIS DOCUMENT. NOKIA SIEMENS NETWORK S RESERVES THE RIGHT TO REVISE THIS DOCUMENT OR WITHDRAW IT AT ANY TIME WITHOUT PRIOR NOTICE. This docu ment and the product it describes are considered protected by copyrights and other intellectual proper ty rights according to the applicable laws. The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG . Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only. Copyright © Nokia Siemens Networks 2010. All rights r eserved. DN0951796 version 01 -2- Deliveries are complete. Equipment is not damaged. Contents of delivery 1 Check list -3- System Module delivery Delivery ContentsVersions Codes System Module with casing FSMB 3 FSPA ESD wrist strap 2 x M5 screws, 4 x K30 screws RF Module delivery FRIA 1.7/2.1 GHz Dual 50 W FRIB 1.7/2.1 GHz Single 50 W RF Module with casing Plinth delivery Mounting kit for floor, wall and poleFMFA Covers delivery 3U front and back covers FMCA P ole mounting kit delivery VMPB 470036A 471000A 471215A 470149A 470239A 469978A Mounting brackets Optional items Grounding cable 2 x fixing plates for the casing 12 x M5x8 screws, 2 x M5x12 screws, 2 x M8 screws 99481 5A FTPB with 8 x rubber plugs, 4 screws, 1 x FCM-FTM connector card, Transmission sub-module deliveries F TEB with 8 x rubber plugs, 4 screws 1 x FCM-FTM connector card, 8 x grounding isolators FTFA with 2 x metal caps, 4 x screws, 1 x FCM-FTM connector card FTIA with 7 x rubber plugs, 4 x screws, 1 x FCM-FT M connector card FTJA with 7 x rubber plugs, 4 x screws, 1 x FCM-FTM connector card FTOA with 1 x rubb er plug, 4 x screws, 1 x FCM-FTM connector card 1 x SDH SFP transceiver 2 x cable clamps Stress relief plate for the power cable 20 x cable ties FRGC 2100 MHz Dual 50 W FRGD 210 0 MHz Single 50 W 471231A 471232A 2 x M5 screws Optical cable Optical transceiver Power cable 994807A 99480…

Text truncated - open the document above for the full version.

ID Label/Location Info

FCC ID Label Model number location ---086400A for FZHE

RF Exposure Info

Compliance with reference levels (based on basic restrictions) for general public and occupational exposure to radio frequency electromagnetic fields Product: Nokia Siemens Networks Flexi Multiradio Base Station / Flexi Multiradio 10 Base Station / Flexi Multiradio GSM/EDGE / Flexi Multiradio Base Station GSM/EDGE (called as Flexi Multiradio Base Station family in this point forward). 1. INSTALLING BASE STATIONS TO ENSURE PUBLIC SAFETY This equipment generates radio frequency energy, which has a thermal effect when absorbed by the human body. For this reason compliance boundaries specific to this equipment have been established. The thermal effects of radio frequency energy can exceed safety levels when a person is inside the established compliance boundaries. By observing the compliance boundary, and ensuring the general public has no access to areas inside the established boundaries will ensure that the general public has no exposure to levels in excess of the safety limits. 2. INSTALLING BASE STATIONS TO ENSURE INSTALLER SAFETY Installation engineers need to be aware of the potential risk of the thermal effects of radio frequency energy and how to protect their self against undue risk. The Warnings and Cautions information of this document is taken from the relevant section of Nokia Siemens Network’s user manual containing warnings and cautions specific to the equipment. 3. WARNINGS AND CAUTIONS PROVIDED The statements shown below are taken from Nokia Siemens Network’s user manual containing warning and cautions specific to the equipment. Reference safety distances When working close to transmitter antennas, the proper safety distances must be observed. The minimum safe distance from an antenna is measured in meters. ! WARNING Do not go any closer to a live antenna than the compliance boundary. The radio frequency energy generated by the antenna poses a serious health risk. ! WARNING If performing installation or maintenance procedures on a BTS, make sure that all transmitters in the area are switched off. When assessing the applicable compliance boundaries European standards EN 50383, EN 50384, EN 50385 and Council Recommendation 1999/519/EC for occupational and general public electromagnetic exposure limits- see Annex A – have been applied. 3.1. ASSESSMENT APPLYING SAR MEASUREMENTS European standards EN 50383, EN 50384 and EN 50385 do not include specifications for whole body SAR measurements. Whole body SAR measurements are not required for transmitters that have maximum output power levels too low to result in exposure levels that can reach the whole body SAR compliance limits under any conditions. Whole body SAR exclusion power levels have been based on worst case assumptions and are as follows: Exposure category Maximum output power (rms) General Public Max power [W]=general public whole body SAR limit 0.08 [W/kg]* 4-year old child mass 12.5 [kg] = 1 W Occupational Max power [W]=occupational whole body SAR limit 0.4 [W/kg]* 16-year old worker 42 [kg] = 16.8 W Table 1 Whole body SAR exclusion power levels. Localized SAR measurement can be used only when 1. The separation between the phantom and the outer surface of the energy generating element is 40 cm or less; 2. The surface area of the energy generating element is less than 60 cm by 30 cm; 3. The frequency is in the range of 800 to 3000 MHz. For the reasons above, SAR measurements are not applicable to • Nokia Siemens Networks Flexi Multiradio Base Station family 3.2 ASSESSMENT OF COMPLIANCE BOUNDARY The compliance boundary is defined as the area around the antenna, shown in Figure 1. The center of the antenna is located at the origin. Distances from the antenna are shown. The top and side views are shown in Figure 2 and Figure 3. Figure 1 Figure 2 Figure 3 The compliance boundaries for the Nokia Siemens Networks Flexi Multiradio Base Station family are given in Table 2 for different power levels at the antenna input. Typical and worst case power level configurations for general public (GP) and occupational (O) exposure limits are included in Table 2. Dfront Dfront triangle Drear Dside back Dside front Dup Ddown Freq. (MHz) Power at antenna input (W) GP O GP O GP O GP O GP O GP O GP O 900 40 7 2.95 2.4 1 0.3 0.05 0.4 0.2 2 0.6 0.95 0.85 0.95 0.85 900 80 9.8 4.45 2.8 2 0.35 0.1 0.4 0.3 2.9 1.2 1.1 0.9 1.1 0.9 900 95 10.7 4.9 3.5 2.2 0.4 0.25 0.7 0.3 3.1 1.3 1.3 0.9 1.3 0.9 900 120 12 5.5 3.5 1.9 0.45 0.3 0.7 0.3 3.45 1.5 1.35 0.95 1.35 0.95 1800 40 4.6 2.1 1.2 1.1 0.2 0.1 0.2 0.2 1.5 0.65 0.5 0.45 0.5 0.45 1800 80 6.45 3 1.5 1.1 0.25 0.15 0.4 0.2 2.05 0.95 0.6 0.5 0.6 0.5 1800 95 7.05 3.3 2 1 0.45 0.35 0.7 0.3 2.25 1.05 0.65 0.5 0.65 0.5 1800 120 7.9 3.65 2.1 1.2 0.5 0.4 0.7 0.3 2.5 1.2 0.65 0.5 0.65 0.5 2100 8 0,55 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.15 0.1 0.7 0.7 0.7 0.7 2100 20 1.8 0.3 0.5 0.1 0.1 0.1 0.2 0.1 0.55 0.15 0.9 0.7 0.7 0.7 2100 40 4.2 0.65 1.0 0.15 0.1 0.1 0.4 0.15 1 0.25 1.25 0.7 0.75 0.7 2100 60 5.7 1.05 1.9 0.25 0.1 0.1 0.5 0.15 2 0.4 1.55 0.8 1.05 0.7 2600 8 0.85 0.15 0.25 0.1 0.1 0.1 0.15 0.1 0.15 0.1 0.7 0.7 0.7 0.7 2600 20 2.7 0.35 0.75 0.1 0.1 0.1 0.25 0.1 0.65 0.15 1.1 0.7 0.8 0.7 2600 40 4.5 0.85 1.6 0.2 0.1 0.1 0.4 0.15 1.4 0.25 1.45 0.7 1.1 0.7 2600 60 5.8 1.4 1.8 0.3 0.1 0.1 0.5 0.15 2 0.35 1.7 0.75 1.25 0.7 Table 2 Dimensions of compliance boundary in meters 3.3 TYPICAL CONFIGURATION Antenna Antenna connector Cable To the base station Figure 4 The antenna is connected through a connector and cable(s) to the base station as shown in Figure 4. A detailed description of the components is given below: Power (P out ) 40 W Total connector loss 0.0 dB Total cable loss 0.0 dB Total Loss (L) = Total connector loss + Total cable loss 0.0 dB Number of transmitter unit (N) 1 Power at antenna input = 10 10 L out N P − 40 W Table 3 The worst-case power level configuration is when N is ( 3 for GSM/EDGE and 1 for LTE/WCDMA/Multiradio) for and there is no loss. In such a case the power at antenna input is 120 W max for G…

Text truncated - open the document above for the full version.

Test Report

Document 75923166 Report 01 Issue 1 August 2013 Report On Radio Testing of the Nokia Siemens Networks Oy Flexi Multiradio 10 BTS RF module 2.6GHz Radio Access technology: E-UTRA (TDD) In accordance with FCC CFR 47 Part 2 and FCC CFR 47 Part 27 COMMERCIAL-IN-CONFIDENCE FCC ID: VBNFZHE-01 TÜV SÜD Product Service, Octagon House, Concorde Way, Segensworth North, Fareham, Hampshire, United Kingdom, PO15 5RL Tel: +44 (0) 1489 558100. Website: www.tuv-sud.co.uk COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page 1 of 6 COMMERCIAL-IN-CONFIDENCE REPORT ON Radio Testing of the Nokia Siemens Networks Oy Flexi Multiradio 10 BTS RF module 2.6GHz Radio Access technology: E-UTRA (TDD) In accordance with FCC CFR 47 Part 2 and FCC CFR 47 Part 27 Document 75923166 Report 01 Issue 1 August 2013 PREPARED FOR Nokia Siemens Networks Oy PO Box 319 Kaapelitie 4 FI-90620 Oulu Finland PREPARED BY Natalie Bennett Senior Administrator (Technical) APPROVED BY Mark Jenkins Authorised Signatory DATED 01 August 2013 Document 75923166 Report 01 Issue 1 Page 2 of 6 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE CONTENTS Section Page No 1 REPORT SUMMARY ................................................................................................................... 3 1.1 Introduction ................................................................................................................................... 4 2 DISCLAIMERS AND COPYRIGHT .............................................................................................. 5 2.1 Disclaimers and Copyright ............................................................................................................ 6 ANNEX A Nokia Siemens Networks Test Report No: D496476672 ......................................................... A.2 Document 75923166 Report 01 Issue 1 Page 3 of 6 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE SECTION 1 REPORT SUMMARY Radio Testing of the Nokia Siemens Networks Oy Flexi Multiradio 10 BTS RF module 2.6GHz Radio Access technology: E-UTRA (TDD) In accordance with FCC CFR 47 Part 2 and FCC CFR 47 Part 27 Document 75923166 Report 01 Issue 1 Page 4 of 6 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE 1.1 INTRODUCTION The information contained in this report is intended to show verification of the Radio Testing of the Nokia Siemens Networks Oy Flexi Multiradio 10 BTS RF module 2.6GHz Radio Access tec hnology: E-UTRA (TDD) In accordance with FCC CFR 47 Part 2 and FCC CFR 47 Part 27. Objective To perform Radio Testing to determine the Equipment Under Test's (EUT’s) compliance with the Test Specification, for the series of tests carried out. Manufacturer Nokia Siemens Networks Oy Model Number(s) FZHE Serial Number(s) RY132201016 Number of Samples Tested 1 Test Specification/Issue/Date FCC CFR 47 Part 2 (2012) FCC CFR 47 Part 27 (2012) Order Number Date 535/90439200 14 June 2013 Start of Test 25 June 2013 Finish of Test 07 July 2013 Name of Engineer(s) Rami Salomäki Jari Veijola Document 75923166 Report 01 Issue 1 Page 5 of 6 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE SECTION 2 DISCLAIMERS AND COPYRIGHT Document 75923166 Report 01 Issue 1 Page 6 of 6 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE 2.1 DISCLAIMERS AND COPYRIGHT This report relates only to the actual item/items tested. This report must not be reproduced, except in its entirety, without the written permission of TÜV SÜD Product Service © 2013 TÜV SÜD Product Service Document 75923166 Report 01 Issue 1 Page A.1 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE ANNEX A NOKIA SIEMENS NETWORKS TEST REPORT NO: D496476672 Document 75923166 Report 01 Issue 1 Page A.2 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.3 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.4 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.5 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.6 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.7 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.8 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.9 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.10 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.11 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.12 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.13 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.14 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.15 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.16 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.17 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.18 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.19 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.20 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.21 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.22 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.23 of A.114 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Document 75923166 Report 01 Issue 1 Page A.24 of A.114 COMMERC…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: VBNFZHE-01 Nokia FZHE Flexi Multiradio 10 BTS RF module 2.6GHz Radio Access technology: E-UTRA (TDD) 2013 Not to be reproduced, except in its entirety, Page 1 of 1 without the Permission of TÜV SÜD Product Service Ltd Reference: 75923166 DIAGRAM/PHOTOGRAPH OF TEST SET UP Radiated Emissions - Diagram Radiated Emissions- EUT in chamber

Contact Information

Applicant

Steve Mitchell
[email protected]972-936-7500Fax: 972-936-7273

Test Firm

TUV SUD Product ServiceJensen Adams
[email protected]44-1489-558252Fax: 44-11489-558101

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
6272.51 GHz - 2.68 GHz15.53 W17M9D9W0.05 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is maximum power per carrier per port. This device supports E-UTRA TDD (10MHz, 20MHz channel bandwidths, 15W per port) with support for 2x2 MIMO. The antenna(s) used with the transmitter must be fix-mounted. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of Section 1.1307(b)(3). Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Nokia Solutions and Networks

Base Transceiver Station Radio Unit - FCC ID VBNAVHA-01 - Nokia Solutions and Networks
VBNAVHA-01

Base Transceiver Station Radio Unit

Dec 01, 2024

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
AirScale Base Transceiver Station Radio Unit - FCC ID VBNAVQQA-01 - Nokia Solutions and Networks
VBNAVQQA-01

AirScale Base Transceiver Station Radio Unit

Oct 02, 2024

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Cellular Network - Base Station - FCC ID VBNAWMFIA-01 - Nokia Solutions and Networks
VBNAWMFIA-01

Cellular Network - Base Station

Apr 10, 2024

Equipment Class

PCB - PCS Licensed Transmitter
Base Transceiver Station Remote Radio Head - FCC ID VBNAHFIHA-01 - Nokia Solutions and Networks
VBNAHFIHA-01

Base Transceiver Station Remote Radio Head

Mar 17, 2024

Equipment Class

PCB - PCS Licensed Transmitter
AKQW AirScale RRH 8T8R n77 320W - FCC ID VBNAKQW-01 - Nokia Solutions and Networks
VBNAKQW-01

AKQW AirScale RRH 8T8R n77 320W

Jan 16, 2024

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter