ArentFox Schiff LLP 1717 K Street, NW Washington, DC 20006 202.857.6000MAIN 202.857.6395FAX afslaw.com Jeffrey E. Rummel Partner and Communications & Technology Practice Leader 202.715.8479DIRECT [email protected] U.S. Agent Designation for Serviceof Process (Applicant and U.S. Agent are Separate Parties) TO: Nemko North America, Inc. 303 River Road, Ottawa, Ontario, Canada K1V 1H2 ATTENTION: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company Name:ArentFox Schiff LLP Contact Name:Jeffrey Rummel Street Address:1717 K St., nw City/Province/Zip:Washington, D.C. 20006 Telephone No: (202)715-8479 Email:[email protected] FRN #: 0021243860 This letter is to confirm that we(“ ArentFox Schiff LLP”) have accepted the responsibility to act asthe Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. U.S. Agent Signature: Date:4/4/2023 Signed by (Printed Name/Title):Jeffrey Rummel The Applicantacknowledges that they must maintain an agentfor no less than one year after terminatingall marketing and importation ORthe conclusion of any Commission - related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent informationabove changes. 022423-17 Rev 6 Applicant Company name: Guangdong Midea Kitchen Appliances Manufacturing Co., Ltd. Grantee Code: VG8 FRN#:0019079995 Contact Name: Jilin Ye Street Address: No.6, Yong An Road, Beijiao, Shunde City/Province/Zip: Foshan, Guangdong, China Telephone No: +86-0757-26339595 Email: [email protected] Applicant Signature: Date:2023/3/28 Signed by (Printed Name/Title): Jilin Ye
GUANGDONG MIDEA KITCHEN APPLIANCES MANUFACTURING CO., LTD. 012423-17 rev2 Certification Application Attestation Statements Date: September 18, 2023 Nemko North America, Inc. 303 River Road, Ottawa, Ontario, Canada K1V 1H2 FCC ID: VG8EM245AXX-P2 To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) Guangdong Midea Kitchen Appliances Manufacturing Co., Ltd. certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. Additional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) Guangdong Midea Kitchen Appliances Manufacturing Co., Ltd. (“the applicant”) certifies that, as of the date of the filing of this application, the applicant ☐ - is / ☐ - is not identified on the Covered List as an entity producing “covered” equipment. Thank you, Ye Jilin By: __________________________ ________________________ (Signature 2 ) (Print name) Title: Certification Engineer _ Company: Guangdong Midea Kitchen Appliances Manufacturing Co., Ltd.__ Telephone: 86-757-2633 9595_____ 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . 2 - Letters should be placed on appropriate letterhead.
041521-14 Nemko North America, Inc .303 River Road, Ottawa, Ontario, Canada K1V 1H2 Authority to Act as Agent Date: September 18, 2023 To Whom It May Concern: __Jawen Yin from ECMG Electronic Technical Testing Corp (Shenzhen)___ is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. We also declare that the information provided to the FCC is true and correct to the best of our knowledge (47 CFR 2.911(d)) an d we have been informed of the grantee responsibilities (4 7 CFR 2.909) with regard to certified equipment. Thank you, Agency Agreement Expiration Date: _____March 18, 2024____ Ye Jilin By: __________________________ ________________________ (Signature 1 ) (Print name) Title: ___Certification engineer_______ On behalf of: _Guangdong Midea Kitchen Appliances Manufacturing Co.,Ltd.____ Telephone: (Company Name) ___86-757-2633 9595____ 1 - Must be signed by app licant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead. Guangdong Midea Kitchen Appliances Manufacturing Co.,Ltd.
Guangdong Midea Kitchen Appliances Manufacturing Co., Ltd 041521-14 Request for Confidentiality Date: September 1 8, 2023 Subject: Confidentiality Request for: ____FCC ID: VG8EM245AXX-P2____ Pursuant to FCC 47 CFR 0.457(d) and 0. 459 and IC RSP-100, Section 12.4, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit ☐Short Term☒PermanentBlock Diagrams ☐Short TermExternal Photos ☐Short Term☐Permanent * 1 Internal Photos ☐Short Term☒PermanentOperation Description/Theory of Operation ☐Short Term☐Permanent Parts List & Placement/BOM ☐Short Term☐PermanentTune-Up Procedure ☐Short Term☒PermanentSchematics ☐Short Term Test Setup Photos ☐Short Term☐Permanent * 3 User’s Manual Guangdong Midea Kitchen Appliances Manufacturing Co., Ltd has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Sincerely, By: Ye Jilin (Signature/Title 3 ) (Print name) 1 - The asterisked items (*) require further information to be provided to ACB before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 and the sp ecific Document link for D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. 2 - Please refer to https://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details. 3 - Must be signed by applicant contact given for app licant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.
GUANGDONG MIDEA KITCHEN APPLIANCES MANUFACTURING CO., LTD. ___________________________________________________________________________________________________ Model Difference Declaration Date: September 18, 2023 Subject: Model difference declaration for FCC ID: VG8EM245AXX-P2 We, Guangdong Midea Kitchen Appliances Manufacturing Co., Ltd, apply FCC certificate for Our product Microwave Oven. E(A)M245A##-P1, E(A)M245A***-P1, E(A)M245A##-P0, E(A)M245B##-P0, E(A)M245A***-P0, E(A)M245B***-P0, E(A)M245AWO-PHB model designations as follow: E: Film type keypad; A: Rotating type knob; M: Indicates microwave function; 245: “2” indicates the microwave output power is 1200W; “45” indicate cavity capacity is 45 liters; A: Indicate the design No.; ## or ***: "#", "*" may be 0~9, A~Z or blank, indicates different appearance; -P1/P0: Indicates Painted (Steel) Cavity; Stand for transduction function -PHB: “P” indicates Painted (Steel) Cavity, “H” with humidity, “B” bread oven. Model of EM245A2GJ-P0H was selected for final testing. Sincerely, By: _ _____ Ye Jilin _ (Signature) (Print name)
Report No.: 20230917G12543X-E APPENDIX II: PHOTOGRAPHS OF PRODUCT PHOTO External Photo CCIC-SET/TRF: IEMC (2019-03-12) Report No.: 20230917G12543X-E CCIC-SET/TRF: IEMC (2019-03-12) Report No.: 20230917G12543X-E CCIC-SET/TRF: IEMC (2019-03-12)
FCC Label: FCC Label Location:
Report No.: 20230917G12543X-E Internal Photo CCIC-SET/TRF: IEMC (2019-03-12) Report No.: 20230917G12543X-E CCIC-SET/TRF: IEMC (2019-03-12) Report No.: 20230917G12543X-E CCIC-SET/TRF: IEMC (2019-03-12) Report No.: 20230917G12543X-E CCIC-SET/TRF: IEMC (2019-03-12) Report No.: 20230917G12543X-E ※※※ End of Report ※※※ CCIC-SET/TRF: IEMC (2019-03-12)
Report No.: 20230917G12543X-E-1 CCIC-SET/TRF:IEMC(2019-03-12) Page 1 of 5 FCC MPE REPORT Report No.: 20230917G12543X-E-1 Product Name: Microwave Oven Trade Name: Midea Model Tested: EM245A2GJ-P0H FCC ID: VG8EM245AXX-P2 Applicant: Guangdong Midea Kitchen Appliances Manufacturing Co., Ltd. Received Date: 2023.09.21 Test Data: 2023.09.21-2023.09.26 Issued by: CCIC Southern Testing Co., Ltd. Lab Location: Electronic Testing Building, No.43, Shahe Road, Xili Street, Nanshan District, Shenzhen, Guangdong, China Tel: 86 755 26627338 Fax: 86 755 26627238 This test report consists of 5 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by CCIC-SET. The test results in the report only apply to the tested sample. The test report shall be invalid without all the signatures of testing engineers, reviewer and approver. Any objections must be raised to CCIC-SET within 15 days since the date when the report is received. It will not be taken into consideration beyond this limit. Report No.: 20230717G08595X-E-1 CCIC-SET/TRF:IEMC(2019-03-12) Page 2 of 5 MAXIMUM PERMISSIBLE EXPOSURE (MPE) Product Name ................. : Microwave Oven Model Tested ................. : EM245A2GJ-P0H Trade Name ...................... Midea Applicant ......................... : Guangdong Midea Kitchen Appliances Manufacturing Co., Ltd. Applicant Address.......... : No.6, Yong An Road, Beijiao, Shunde, Foshan, China Manufacturer .................. : Guangdong Midea Kitchen Appliances Manufacturing Co., Ltd. Manufacturer Address ... : No.6, Yong An Road, Beijiao, Shunde, Foshan, China Standard(s) ..................... : FCC/OST MP-5(1986), OET Bulletin 56(1999) Test Result ...................... : PASS Tested by ....................... : Ruihong Xie Test Engineer 2023.09.26 Reviewed by ................... : Chris You Senior Engineer 2023.09.26 Approved by ................... : 2023.09.26 Yang Fan, Manager Report No.: 20230717G08595X-E-1 CCIC-SET/TRF:IEMC(2019-03-12) Page 3 of 5 1.1 Facilities and Accreditations 1.1.1 Facilities FCC-Registration No.: CN1283 CCIC Southern Testing Co., Ltd EMC Laboratory has been registered and fully described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from the FCC is maintained in our files. Designation Number: CN1283, valid time is until Sep.30, 2023. A2LA Code: 5721.01 CCIC-SET is a third-party testing organization accredited by A2LA according to ISO/IEC 17025. The accreditation certificate number is 5721.01. 1.1.2 Test Environment Conditions During the measurement, the environmental conditions were within the listed ranges: Temperature (°C): 15°C- 35°C Relative Humidity (%): 25% -75% Atmospheric Pressure (kPa): 86kPa-106kPa 1.1.3 Measurement Uncertainty The uncertainty is calculated using the methods suggested in the "Guide to the Expression of Uncertainty in Measurement" (GUM) published by ISO. Uncertainty of Radiation Hazard Test: Uc = 2.4 dB (k=2) EQUIPMENTS LIST A. Equipment List: Description Manufacturer Model Serial No. Calibration Date Calibration Due. Date Portable Spectrometer Rohde & Schwarz FSH8 A1140401672 2023.02.14 2024.02.13 Probe Rohde & Schwarz TSEMF-B1 A1140401671 2023.02.14 2024.02.13 Report No.: 20230717G08595X-E-1 CCIC-SET/TRF:IEMC(2019-03-12) Page 4 of 5 1.2 RADIATION HAZARD TEST 1.2.1 Radiation Hazard (Health) Requirement For ISM equipment operating on higher frequencies (above 900 MHz), in particulars microwave ovens and medical diathermy equipment, radiation leakage should be measured in accordance with the current Bureau of Radiological Health standard, employing an electromagnetic radiation monitor. This test is made primarily to assure that personnel will not be exposed to radiation hazard in testing the equipment. Equipment submitted to the FCC which have radiation leakage apparently in excess of BRH limit will be reported to BRH for their evaluation. See FCC Bulletin OST 56, "Questions and Answers about Biological Effects and Potential Hazards of Radiofrequency Radiation". 1.2.2 Test Procedure The EUT was set-up according to the FCC MP-5 and FCC Part 18 for radiation Hazard measurement. The measurement was using a microwave leakage meter to measure the radiation leakage in the as- received condition with the oven door closed A 770mL water load in a breaker was located in the center of the oven and the microwave oven was set to maximum power. While the oven operating, the microwave meter will check the leakage and then record the maximum leakage. 1.2.3 Limit Limits for General Population/Uncontrolled Exposure NOTE 1: Occupational/controlled limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when an individual is transient through a location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure. Report No.: 20230717G08595X-E-1 CCIC-SET/TRF:IEMC(2019-03-12) Page 5 of 5 NOTE 2: General population/uncontrolled exposures apply in situations in which the general public may be exposed, or in which persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot exercise control over their exposure. A maximum of 1.0mW/cm 2 is allowed in according with the applicable FCC standards 1.2.4 Test results Test location: Test result (mW/cm 2 ) Limit (mW/cm 2 ) Verdict Left side 0.17 1.0 Pass Right side 0.16 1.0 Pass Front 0.41 1.0 Pass Rear 0.09 1.0 Pass There was no microwave leakage exceeding a power level of 0.41mW/cm 2 Observed at any point 5cm or more from the external surface of the oven. 1.2.5 Test setup…
Text truncated - open the document above for the full version.
Report No.: 20230917G12543X-E CCIC-SET/TRF:IEMC(2019-03-12) Page 1 of 21 FCC PART 18 TEST REPORT Report No.: 20230917G12543X-E Product Name: Microwave Oven Trade Name: Midea Model No. : E(A)M245A##-P1, E(A)M245A***-P1, E(A)M245A##-P0, E(A)M245B##-P0, E(A)M245A***-P0, E(A)M245B***-P0, E(A)M245AWO-PHB FCC ID : VG8EM245AXX-P2 Applicant: Guangdong Midea Kitchen Appliances Manufacturing Co., Ltd. Received Date: 2023.09.21 Test Data: 2023.09.21-2023.09.26 Issued by: CCIC Southern Testing Co., Ltd. Lab Location: Electronic Testing Building,No.43ShaheRoad,Xili Street, Nanshan District, Shenzhen, Guangdong, China Tel: 86 755 26627338 Fax: 86 755 26627238 This test report consists of 21 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by CCIC-SET. The test results in the report only apply to the tested sample. The test report shall be invalid without all the signatures of testing engineers, reviewer and approver. Any objections must be raised to CCIC-SET within 15 days since the date when the report is received. It will not be taken into consideration beyond this limit. Report No.: 20230917G12543X-E CCIC-SET/TRF:IEMC(2019-03-12) Page 2 of 21 Test Report Product Name ....................... : Microwave Oven Model No. ............................ : E(A)M245A##-P1, E(A)M245A***-P1, E(A)M245A##-P0, E(A)M245B##-P0, E(A)M245A***-P0, E(A)M245B***-P0, E(A)M245AWO-PHB Trade name ............................ Midea Applicant ............................... : Guangdong Midea Kitchen Appliances Manufacturing Co., Ltd. Applicant Address................ : No.6, Yong An Road, Beijiao, Shunde, Foshan, China Manufacturer ........................ : Guangdong Midea Kitchen Appliances Manufacturing Co., Ltd. Manufacturer Address ......... : No.6, Yong An Road, Beijiao, Shunde, Foshan, China Test Standards ..................... : 47 CFR Part 18 Test Result ............................ : PASS Tested by ............................. : Ruihong Xie Test Engineer 2023.09.26 Reviewed by ......................... : Chris You Senior Engineer 2023.09.26 Approved by ......................... : 2023.09.26 Yang Fan, Manager Report No.: 20230917G12543X-E CCIC-SET/TRF:IEMC(2019-03-12) Page 3 of 21 TABLE OF CONTENTS 1. GENERAL INFORMATION .................................................................................................... 5 1.1 GENERAL DESCRIPTION OF EUT ...................................................................................... 5 1.2 Test Standards and Results ........................................................................................................ 6 1.3 Facilities and Accreditations ...................................................................................................... 7 1.3.1 Facilities .................................................................................................................................... 7 1.3.2 Test Environment Conditions .................................................................................................... 7 1.3.3 Measurement Uncertainty ......................................................................................................... 8 2. EQUIPMENTS LIST ................................................................................................................. 8 3. EMC EMISSION TEST ............................................................................................................. 9 3.1 Test Procedure ............................................................................................................................. 9 3.1.1 Frequency For Normal Voltage ................................................................................................. 9 3.1.2 Frequency For Line Voltage ...................................................................................................... 9 3.1.3 Measurement data ................................................................................................................... 10 3.2 RADIATION HAZARD TEST ................................................................................................ 10 3.2.1 Test Setup ................................................................................................................................ 10 3.2.2 Limit ........................................................................................................................................ 10 3.2.3 Test results ............................................................................................................................... 10 3.3 RF OUTPUT POWER MEASUREMENT ............................................................................ 10 3.3.1 Test Standard ........................................................................................................................... 10 3.3.2 EUT Operating mode .............................................................................................................. 11 3.3.3 Test Data .................................................................................................................................. 11 4. CONDUCTED EMISSION ..................................................................................................... 12 4.1.1 Conducted Emission Limit ...................................................................................................... 12 4.1.2 Test Procedure ......................................................................................................................... 12 4.1.3 Test Setup ................................................................................................................................ 12 5. RADIATED EMISSION .......................................................................................................... …
Text truncated - open the document above for the full version.
Report No.: 20230917G12543X-E CCIC-SET/TRF:IEMC(2019-03-12) Page 20 of 21 APPENDIX I:PHOTOGRAPHS OF EMC TEST CONFIGURATION 1. Radiated Emission Measurement below 1GHz 2. Radiated Emission Measurement above 1GHz Report No.: 20230917G12543X-E CCIC-SET/TRF:IEMC(2019-03-12) Page 21 of 21 3.Conducted emission at AC mains input/output port Measurement 4.Radiation Hazard Test
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 2.45 GHz - 2.45 GHz | - |

Microwave Oven
Equipment Class
8CC - Part 18 Consumer Device
Microwave Oven
Equipment Class
8CC - Part 18 Consumer Device
Microwave Oven
Equipment Class
8CC - Part 18 Consumer Device
Microwave Oven
Equipment Class
8CC - Part 18 Consumer Device
Microwave Oven
Equipment Class
8CC - Part 18 Consumer Device