FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Guangdong Midea Kitchen Appliances Manufacturing Co.,Ltd/
  3. VG8XM025FYY

VG8XM025FYYMicrowave Oven

Guangdong Midea Kitchen Appliances Manufacturing Co.,Ltd
Microwave Oven - FCC ID VG8XM025FYY - Guangdong  Midea  Kitchen  Appliances  Manufacturing  Co.,Ltd
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Dec 13, 2007
Application Purpose
Original Equipment
Date of Application
Dec 12, 2007
Equipment Note
Microwave Oven
Frequency Range
2450.00000000 - 2450.00000000
Company
Guangdong Midea Kitchen Appliances Manufacturing Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

SAVE THESE INSTRUCTIONS CAREFULLY Read these instructions carefully before using your microwave oven, and keep it carefully. If you follow the instructions, your oven will provide you with many years of good service. INSTRUCTION MANUAL MODEL:E(A)M025FYY Microwave Oven 120V~ 60Hz 1500W 1000W 1.0 Cu.ft. Specifications E(A)M025FYY 2 Handling the cord on this press or cords associated with accessories sold with this product, will expose you to lead a chemical known to the state of California to cause cancer, and birth defects or other reproductive harm. Wash hands after handle. PRECAUTIONS TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY (a) Do not attempt to operate this oven with the door open since this can result in harmful exposure to microwave energy. It is important not to break or tamper with the safety interlocks. (b) Do not place any object between the oven front face and the door or allow soil or cleaner residue to accumulate on sealing surfaces. (c) Do not operate the oven if it is damaged. It is particularly important that the oven door closes properly and that there is no damage to the: (1) DOOR (bent) (2) HINGES AND LATCHES (broken or loosened) (3) DOOR SEALS AND SEALING SURFACE (d) The oven should not be adjusted or repaired by anyone except properly qualified service personnel. Model: Rated Voltage: Rated Input Power(Microwave): Rated Output Power(Microwave): Oven Capacity: External Dimensions (WxHxD): Net Weight: Warning: Approx. 39.5 Lbs If the apparatus is not maintained in a good state of cleanliness, its surface could be degraded and affect the lifespan of the apparatus and lead to a dangerous situation. ADDENDUM 20.2X15.6X12.1 inch 3 SAFETY 1. The oven must be on a leveled surface. 2. The turntable and turntable roller rest must be in the oven during cooking. Place the cookware gently on the turntable and handle it carefully to avoid possible breakage. 3. Incorrect use of browning dish may cause the turntable to break. 4. Use only the specified bag size when using Direct Access Popcorn. 5. The oven has several built-in safety switches to ensure that the power remains off when the door is open. Do not tamper with these switches. 6. Do not operate the microwave oven empty. Operating the oven with no food or food that is extremely low in moisture can cause fire, charring or sparking. 7. Do not cook bacon directly on the turntable. Excessive local heating of the turntable may cause the turntable to break. 8. Do not heat baby bottles or baby food in the microwave oven. Uneven heating may occur and could cause physical injury. 9. Do not heat narrow-necked containers, such as syrup bottles. 10. Do not attempt to deep-fry in your microwave oven. 11. Do not attempt home canning in this microwave oven, as it is impossible to be sure all contents of the jar have reached boiling temperature. 12. Do not use this microwave oven for commercial purpose. This microwave oven is made for household use only. 13. To prevent delayed eruptive boiling of hot liquids and beverages or scalding yourself, stir liquid before placing the container in the oven and again halfway through cooking time. Let stand in the oven for a short time and stir again before removing the container. 14. Use carefully when cooking food in the microwave oven to avoid burning due to excessive cooking. 15. When the appliance is operated in the combination mode, children should only use the oven under adult supervision due to the temperatures generated. 16. Failure to maintain the oven in a clean condition could lead to deterioration that could adversely affect the life of the appliance and possibly result in a hazardous situation. 4 IMPORTANT SAFETY INSTRUCTIONS WARNING 1. Read all instructions before using the appliance. 2. Read and follow the specific: "PRECAU- TIONS TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY" on page 2. 3. As with most cooking appliances, close supervision is necessary to reduce the risk of a fire in the oven cavity. If materials inside the oven ignite: 1. Keep the oven door closed. 2. Turn the oven off, and unplug the appliance. 3. Disconnect the power cord, shut off power at the fuse or circuit breaker panel. 4. Do not overcook food. Carefully attend the appliance when paper, plastic, or other combustible materials are placed inside the oven to facilitate cooking. 5. Do not use the oven cavity for storage purposes. Do not store combustible items such as bread, cookies, paper products, etc. inside the oven. 6. Remove wire twist-ties and metal handles from paper or plastic containers/bags before placing them in the oven. 7. This oven must be grounded. Connect only to properly grounded outlet. See "GROUNDING INSTRUCTIONS" on page 5. 8. Install or locate this oven only in accordance with the installation instructions provided. 9. Some products such as whole eggs, water with oil or fat, sealed to explode and therefore should not be heated in this oven. To reduce the risk of fire, electric shock, injury to persons or exposure to excessive microwave oven energy when using your appliance, follow basic precautions, including the following: 10. Use this appliance only for its intended uses as described in this manual. Do not use corrosive chemicals or vapors in this appliance. This oven is specifically designed to heat or cook food. It is not designed for industrial or laboratory use. 11. As with any appliance, close supervision is necessary when used by children. 12. Do not operate this oven if it has a damaged cord or plug, if it is not working properly or if it has been damaged or dropped. 13. This appliance should be serviced only by qualified service technicians. Contact the nearest authorized service facility for examination, repair or adjustment. 14. Do not cover or block any vents on the oven. 15. Do not store or use this appliance outdoors. 16. Do not use this oven near water, for example, near a kitchen sink, in a wet basement, near a swimming pool, or similar locations. 17. D…

Text truncated - open the document above for the full version.

Cover Letter(s)

Original Web Site: www.midea.com.cn Beijiao, Shunde E-Mail: [email protected] Foshan , Guangdong, China Phone : +86 0757-23606480 FAX : + 86 0757-26656995 AGENCY AUTHORIZATION LETTER FCC ID: VG8 Date: Dec 05 , 2007 To whom it may concern: We, the undersigned,hereby authorize ECMG to act on our behalf , as our agent ,in the following matters related to the FCC approval of our products: report submittal, related correspondence, the signing of all documents relating to the matters. and any other lawful activity necessary to obtain such certification. Any act carried out by ECMG within the scope of this authorization shall have the same effecs as our own. This authorization shall expire 6 months from original date , if you have any question regarding the authorization , please don’t hesitate to contact us , thank you. Sincerely, William Huang Midea Microwave and Electrical Appliances Manufacturing Co., Ltd Phone : +86-757-23606480 FAX :+86-757-26656995 E-Mail: [email protected]

Cover Letter(s)

Date: Dec 05 , 2007 Federal communications commission Authorization and Evaluation Division FCC ID: VG8 Confidentiality Request Pursuant to section 0.457 and 0.459 of the commission’s rules, the applicant hereby requests confidential treatment of information accompanying this application as outline below: 1. Schematics 2. Block diagram 3. Operational description The above materials contain trade secrets and proprietary information not customarily released to the public, the public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457, disclosure of this application and all accompanying documentation will not be made before the date of the grant for this application. Sincerely, William Huang Midea Microwave and Electrical Appliances Manufacturing Co., Ltd Phone : +86-757-23606480 FAX :+86-757-26656995 E-Mail: [email protected]

External Photos

1 External Photo of EUT sample Photo 1- Front view of EUT Photo 2- Back view of EUT 2 Photo 3 –Top view of EUT Photo 3 –Bottom view of EUT

ID Label/Location Info

Label & Location Proposed FCC Label Format: Dimention:Length x width = 160mm x 50mm Specifications: Text is white or black in color and is left justified ,Labels are printed in indelible ink on permanent adhesive backing or sile-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. Proposed FCC Label Location: FCC Warning Statement: The Device complies with part 18 of the FCC rules,Operation is subject to the following conditions: (1) This device may not cause harmful interference,and (2) this device must accept any interference received,including interference that may cause undersired operation .

Internal Photos

1 Internal Photo of EUT sample Photo 1- Uncovered view of EUT Photo 2- Inside view of EUT 2 Photo 3 – Top view of main board Photo 4 – Bottom view of main board 3 Photo 5 –Magnetron View

Test Report

EMI Test Report On Model Name: Microwave oven (Counter-top) Model Numbers: XM025FYY Brand Name: FCC ID: VG8XM025FYY Prepared for Midea Microwave and Electrical Appliances Manufacturing Co.,Ltd According to FCC Part 18 Industrial, Scientific and Medical Equipment FCC/OST MP-5(1986) FCC methods of measurements of radio noise emission from industrial,scientific and medical equipment Test Report#: PSZ-0711-0561-FCCID Prepared by: Eddy Chen Reviewed by: Ivan Wen QC Manager: Paul Chen Test Report Released by: 2007, Dec 06 ⎯⎯⎯⎯⎯⎯⎯⎯ ⎯⎯⎯⎯⎯⎯ Paul Chen Date List Attached Files Exhibit Type File Description File Name Test Report Test Report VG8XM025FYY _Test report.pdf Operation Description Technical Description VG8XM025FYY_operation description.pdf External Photos External Photos VG8XM025FYY_External Photos Internal Photos Internal Photos VG8XM025FYY_Internal Photos Block Diagram Block Diagram VG8XM025FYY_Block Diagram.pdf Schematics Circuit Diagram VG8XM025FYY _Schematics.pdf ID Label/Location Label and Location VG8XM025FYY _Label & Location.pdf User Manual User Manual VG8XM025FYY _User Manual.pdf Test setup photos Test setup photos VG8XM025FYY _Test Setup Photos Test Location Tests performed in a Certified ANSI Semi-Anechoic Chamber and Shielded Room. Test Site Location: Shenzhen Academy of Metrology and Quality inspection Longzhu Road, Nanshan District,Shenzhen, Guangdong,China Tel : 86-755-26941617 Fax : 86-755-26941615 FCC Registration Number: 274801 Table of Contents GOVERNMENT DISCLAIMER NOTICE ______________________________________________ 1 REPRODUCTION CLAUSE _________________________________________________________ 1 OPINIONS AND INTERPRETATIONS _______________________________________________ 1 STATEMENT OF MEASUREMENT UNCERTAINTY ___________________________________ 1 ADMINISTRATIVE DATA __________________________________________________________ 2 EUT DESCRIPTION ________________________________________________________________ 2 TYPE OF DERIVER ________________________________________________________________ 3 TEST SUMMARY __________________________________________________________________ 4 LOAD FOR MICROWAVE OVENS __________________________________________________ 5 EQUIPMENT MODIFICATION ______________________________________________________ 5 EUT SAMPLE PHOTOS FOR MODEL _______________________________________________ 6 TEST SYSTEM DETAILS ___________________________________________________________ 9 CONFIGURATION OF TESTED SYSTEM ___________________________________________10 ATTACHMENT 1 – RADIATION HAZARD TEST ____________________________________11 ATTACHMENT 2 – INPUT POWER MEASUREMENT ________________________________13 ATTACHMENT 3 – RF OUTPUT POWER MEASUREMENT___________________________15 ATTACHMENT 4 – OPERATING FREQUENCY MEASUREMENT______________________17 ATTACHMENT 5 - CONDUCTED EMISSION TEST RESULTS ________________________20 ATTACHMENT 6 - RADIATED EMISSION TEST RESULTS __________________________24 Test Report #: PSZ-0711-0561-FCCID Prepared for Midea Microwave and Electrical Appliances Manufacturing Co.,Ltd Prepared by ECMG Worldwide Certification Solution Inc. Page 1 of 27 Government Disclaimer Notice When government drawing, specification, or other data are used for any purpose other than in connection with a definitely related government procurement operation, the United States Government thereby incurs no responsibility nor any obligation whatsoever; and the fact that the Government may have formulated, furnished, or in any way supplied the said drawing, specifications, or other data, is not to be regarded by implication or otherwise in any manner licensing the holder or any other person or corporation, or conveying any rights or permission to manufacture, use, or sell patented invention that may in any way be related thereto. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Reproduction Clause Any reproduction of this document must be done in full. No single part of this document may be reproduced without permission from ECMG Worldwide Certification Solution Inc., Opinions and Interpretations This test report relates to the abovementioned equipment under test (EUT). Without the permission of ECMG Worldwide Certification Solution Inc., Test Lab this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark on this or similar products. The manufacturer has sole responsibility of continued compliance of the device. Statement of Measurement Uncertainty The data and results referenced in the document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities that can account for a nominal measurement error. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. Test Report #: PSZ-0711-0561-FCCID Prepared for Midea Microwave and Electrical Appliances Manufacturing Co.,Ltd Prepared by ECMG Worldwide Certification Solution Inc. Page 2 of 27 Administrative Data Test Sample : Microwave Oven (Counter-top) Model Numbers : XM025FYY Model Tested : EM025FBN Brand Name : Date Tested : 2007, Dec 03 to 05 Applicant : Midea Microwave and Electrical Appliances Manufacturing Co.,Ltd Beijiao., Shunde, Foshan, Guangdong, China. Telephone : 86-0757-23606480 Fax : 86-0757-23656995 Manufacturer : Midea Microwave and Electrical Appliances Manufacturing Co.,Ltd Beijiao., Shunde, Foshan, Guangdong, China. EUT Description Midea Microwave and Electrical Appliances Manufacturing Co.,Ltd ,model tested EM025FBN (referred to the EUT in this report) is a Microwave Oven. Power Supply 120V AC , 60 Hz Rated Input Power 1500W Rated Output Power 1000W Operation Frequency 2450MHz Magnetron Manufacturer TOSHIBA Magnetron Model Number 2M248J Outside Dimensions (W×H×D) 20.1X15.6X12.1 inch Oven Capacity: 1.0 cu.ft Net Weight Approx. 39.5 lbs. Test Report #: PSZ-0711-0…

Text truncated - open the document above for the full version.

Test Setup Photos

TEST SETUP PHOTOGRAPHS 1. AC input power measurement 2. Conducted Emission Test 3. Operation frequency measurement 4.Radiated emission measurement 5. Radiation hazard test 6. RF output power measurement

Contact Information

Applicant

Jilin Ye(Engineer)
[email protected]+86-0757-26339595Fax: +86-0757-26656995

Technical Contact

ECMGIvan Wen
[email protected]86 755 82984733 812

Chegong Temple, Shennan road · Shenzhen Guangdong · China

Test Firm

Shenzhen Academy of Metrology & Quality InspectionPeter Lin
[email protected]8675526941599Fax: 8675526941545

Technical Specifications

#Rule PartsFrequency RangePower OutputTolerance
1182.45 GHz - 2.45 GHz710.2 W0.1340000000 %
Confidentiality
Long Term
Grant Notes
Magnetron Model: Toshiba 2M248J

Other Applications from Guangdong Midea Kitchen Appliances Manufacturing Co.,Ltd

Microwave Oven - FCC ID VG8TJ018GXX - Guangdong  Midea  Kitchen  Appliances  Manufacturing  Co.,Ltd
VG8TJ018GXX

Microwave Oven

Dec 18, 2025

Equipment Class

8CC - Part 18 Consumer Device
Microwave Oven - FCC ID VG8TC934DYYM - Guangdong  Midea  Kitchen  Appliances  Manufacturing  Co.,Ltd
VG8TC934DYYM

Microwave Oven

Dec 15, 2025

Equipment Class

8CC - Part 18 Consumer Device
Microwave Oven - FCC ID VG8AM0P02YY - Guangdong  Midea  Kitchen  Appliances  Manufacturing  Co.,Ltd
VG8AM0P02YY

Microwave Oven

Sep 22, 2024

Equipment Class

8CC - Part 18 Consumer Device
Microwave Oven - FCC ID VG8TC934DYY - Guangdong  Midea  Kitchen  Appliances  Manufacturing  Co.,Ltd
VG8TC934DYY

Microwave Oven

Sep 22, 2024

Equipment Class

8CC - Part 18 Consumer Device
Microwave Oven - FCC ID VG8EM9P04YY - Guangdong  Midea  Kitchen  Appliances  Manufacturing  Co.,Ltd
VG8EM9P04YY

Microwave Oven

Aug 27, 2024

Equipment Class

8CC - Part 18 Consumer Device