
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
i VigorAP 1060C 11ax Ceiling AP Quick Start Guide Version: 1.0 Firmware Version: V1.3.0 (For future update, please visit DrayTek web site) Date: July 9, 2020 i Intellectual Property Rights (IPR) Information Copyrights © All rights reserved. This publication contains information that is protected by copyright. No part may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language without written permission from the copyright holders. Trademarks The following trademarks are used in this document: Microsoft is a registered trademark of Microsoft Corp. Windows, Windows 8, 10 and Explorer are trademarks of Microsoft Corp. Apple and Mac OS are registered trademarks of Apple Inc. Other products may be trademarks or registered trademarks of their respective manufacturers. Safety Instructions and Approval Safety Instructions Read the installation guide thoroughly before you set up the device. The device is a complicated electronic unit that may be repaired only be authorized and qualified personnel. Do not try to open or repair the device yourself. Do not place the device in a damp or humid place, e.g. a bathroom. Do not stack the devices. The device should be used in a sheltered area, within a temperature range of 0 to +40 Celsius. Do not expose the device to direct sunlight or other heat sources. The housing and electronic components may be damaged by direct sunlight or heat sources. Do not deploy the cable for LAN connection outdoor to prevent electronic shock hazards. Keep the package out of reach of children. When you want to dispose of the device, please follow local regulations on conservation of the environment. Warranty We warrant to the original end user (purchaser) that the device will be free from any defects in workmanship or materials for a period of one (1) year from the date of purchase from the dealer. Please keep your purchase receipt in a safe place as it serves as proof of date of purchase. During the warranty period, and upon proof of purchase, should the product have indications of failure due to faulty workmanship and/or materials, we will, at our discretion, repair or replace the defective products or components, without charge for either parts or labor, to whatever extent we deem necessary tore-store the product to proper operating condition. Any replacement will consist of a new or re-manufactured functionally equivalent product of equal value, and will be offered solely at our discretion. This warranty will not apply if the product is modified, misused, tampered with, damaged by an act of God, or subjected to abnormal working conditions. The warranty does not cover the bundled or licensed software of other vendors. Defects which do not significantly affect the usability of the product will not be covered by the warranty. We reserve the right to revise the manual and online documentation and to make changes from time to time in the contents hereof without obligation to notify any person of such revision or changes. ii Declaration of Conformity Hereby, DrayTek Corporation declares that the radio equipment type VigorAP 1060C is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.draytek.com.tw/ftp/VigorAP 1060C/Document/CE/ Manufacturer: DrayTek Corp. Address: No. 26, Fu Shing Road, HuKou Township, HsinChu Industrial Park, Hsin-Chu County, Taiwan 303 Product: VigorAP 1060C Frequency Information for Europe area: 2.4G WLAN 2412MHz - 2472 MHz, max. TX power: 15.35dBm *1 5G WLAN 5150MHz - 5250 MHz, max. TX power: 18.15dBm; 5250MHz - 5350 MHz, max. TX power: 18.22dBm; 5470MHz - 5725 MHz, max. TX power: 24.15dBm *2 (*1: for 2.4G WLAN model; *2: for 5G WLAN model) This product is designed for 2.4GHz and 5GHz WLAN network throughout the EC region. Regulatory Information Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device may accept any interference received, including interference that may cause undesired operation. iii USA Local Representative Company name ABP International Inc. Address 13988 Diplomat Drive Suite 180 Dallas TX 75234 ZIP Code 75234 E-mail [email protected] Contact Person Mr. Robert Messer Tel. 19728311600 Caution Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This equipment complies with CE RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance …
Text truncated - open the document above for the full version.
Page 1 of 8 External Photos Model Number: VigorAP 1060C Page 2 of 8 EUT Photo (1) EUT Photo (2) Page 3 of 8 EUT Photo (3) EUT Photo (4) Page 4 of 8 EUT Photo (5) EUT Photo (6) Page 5 of 8 EUT Photo (7) EUT Photo (8) Page 6 of 8 EUT Photo (9) EUT Photo (10) Page 7 of 8 EUT Photo (11) EUT Photo (12) Page 8 of 8 EUT Photo (13)
Label Info. & Label Location
Page 1 of 12 Internal Photos Model Number: VigorAP 1060C Page 2 of 12 EUT Photo (1) EUT Photo (2) Page 3 of 12 EUT Photo (3) EUT Photo (4) Page 4 of 12 EUT Photo (5) EUT Photo (6) Page 5 of 12 EUT Photo (7) EUT Photo (8) Page 6 of 12 EUT Photo (9) EUT Photo (10) Page 7 of 12 EUT Photo (11) EUT Photo (12) Page 8 of 12 EUT Photo (13) EUT Photo (14) Page 9 of 12 EUT Photo (15) EUT Photo (16) Page 10 of 12 EUT Photo (17) EUT Photo (18) WLAN 2.4G ANT-2 WLAN 5G ANT-3 WLAN 2.4G ANT-1 WLAN 5G ANT-2 WLAN 2.4G ANT-0 WLAN 5G ANT-0 WLAN 2.4G ANT-3 WLAN 5G ANT-1 Page 11 of 12 EUT Photo (19) EUT Photo (20) Page 12 of 12 EUT Photo (21)
MPE Report Applicant : Draytek Corporation Product Type : 11ax Ceiling AP Trade Name : DrayTek Model Number : VigorAP 1060C Applicable Standard : IEEE Std.C95.1 47 CFR § 2.1091 / 47 CFR § 1.1310 Received Date : May 13, 2020 Te s t Period : Jun. 10 ~ Jun. 20, 2020 Issue Date : No v. 10, 2020 Issued by Tested By : (Kris Pan) A Test Lab Techno Corp. No. 140-1, Changan Street, Bade District, Taoyuan City 33465, Taiwan (R.O.C.) Te l:+886-3-2710188 / Fax:+886-3-2710190 Taiwan Accreditation Foundation accreditation number: 1330 Test Firm MRA designation number: TW0010 Note: 1.The test results are valid only for samples provided by customers and under the test conditions described in this report. 2.This report shall not be reproduced except in full, without the written approval of A Test Lab Technology Corporation. 3.The relevant information is provided by customers in this test report. According to the correctness, appropriateness or completeness of the information provided by the customer, if there is any doubt or error in the information which affects the validity of the test results, the laboratory does not take the responsibility. Report Number: 2007FS18 Rev.01 Page 1 of 13 Revision History Re v. Issued Date Revisions Revised By 00 Nov. 04, 2020 Initial Issue Nicole Chu 01 No v. 10, 2020 P13 Revised Limit Nicole Chu Report Number: 2007FS18 Rev.01 Page 2 of 13 Contents 1. Reference Applicable Standard .......................................................................................................... 4 2. Description of Equipment under Test (EUT) ....................................................................................... 5 3. Human Exposure Assessment ............................................................................................................ 7 4. Power Density Limit – RF Exposure Evaluation ................................................................................. 8 4.1 Conducted Power ............................................................................................................................... 9 5. Test Result ........................................................................................................................................ 13 Report Number: 2007FS18 Rev.01 Page 3 of 13 1. Reference Applicable Standard Standard Description Version ANSI/IEEE C95.1 American National Standard safety levels with respect to human exposure to radio frequency electromagnetic fields, 300 KHz to 100 GHz, New York. 1992 47 CFR Part §2.1091 Radiofrequency radiation exposure evaluation: mobile devices. - 47 CFR Part §1.1310 Radiofrequency radiation exposure limits. - Report Number: 2007FS18 Rev.01 Page 4 of 13 2. Description of Equipment under Test (EUT) Applicant Draytek Corporation No.26, Fu Shing Rd., HuKou County, Hsinchu Industrial Park, Hsinchu, 303 Taiwan Manufacturer DrayTek Corporation No.26, Fu Shing Rd., HuKou County, Hsinchu Industrial Park, Hsinchu, 303 Taiwan Product Type 11ax Ceiling AP Trade Name DrayTek Model Number VigorAP 1060C FCC ID VGYAP1060C Frequency Range Operate Band Frequency Range (MHz) IEEE 802.11b / 802.11g 2412 - 2462 IEEE 802 11n 2.4 GHz 20 MHz(256-QAM) IEEE 802 11ax 2.4 GHz 20 MHz 2412 - 2462 IEEE 802.11n 2.4 GHz 40 MHz (256-QAM) IEEE 802.11ax 2.4 GHz 40 MHz 2422 - 2452 IEEE 802.11a U-NII Band I 5180 - 5240 IEEE 802.11a U-NII Band III 5745 - 5825 IEEE 802.11ac 5 GHz 20 MHz U-NII Band I IEEE 802.11ax 20 MHz U-NII Band I 5180 - 5240 IEEE 802.11ac 5 GHz 20 MHz U-NII Band III IEEE 802.11ax 20 MHz U-NII Band III 5745 - 5825 IEEE 802.11ac 5 GHz 40 MHz U-NII Band I IEEE 802.11ax 40 MHz U-NII Band I 5190 - 5230 IEEE 802.11ac 5 GHz 40 MHz U-NII Band III IEEE 802.11ax 40 MHz U-NII Band III 5755 - 5795 IEEE 802.11ac 80 MHz IEEE 802.11ax 80 MHz 5210 5775 Antenna Information Model Type Max. Gain (dBi) 5718A0514300 PIFA Antenna 2412 - 2472 3.70 5718A0515300 PIFA Antenna 2412 - 2472 4.08 5718A0516300 PIFA Antenna 2412 - 2472 4.12 5718A0517300 PIFA Antenna 2412 - 2472 5.01 G ANT 4.25 Directional 10.26 5718A0518300 PIFA Antenna 5150~5250 5.13 5725~5850 5.19 5718A0522300 PIFA Antenna 5150~5250 4.26 5725~5850 3.81 5718A0520300 PIFA Antenna 5150~5250 4.03 5725~5850 4.56 5718A0521300 PIFA Antenna 5150~5250 5.04 5725~5850 5.04 G ANT 5150~5250 4.64 5725~5850 4.68 Directional 5150~5250 10.65 5725~5850 10.69 Report Number: 2007FS18 Rev.01 Page 5 of 13 Antenna Delivery IEEE 802.11b: 1TX / 1RX (Diversity) IEEE 802.11g : 4TX / 4RX (CDD) IEEE 802.11n 2.4 GHz 20 MHz / 40 MHz: 4TX / 4RX (STBC / Beamforming on) IEEE 802.11ax 2.4 GHz 20 MHz / 40 MHz: 4TX / 4RX (STBC / Beamforming on) IEEE 802.11a: 4TX / 4RX(CDD) IEEE 802.11ac 20 MHz / 40 MHz / 80 MHz: 4TX / 4RX (STBC / Beamforming on) IEEE 802.11ax 20 MHz / 40 MHz / 80 MHz: 4TX / 4RX (STBC / Beamforming on) RF Evaluation 0.443 mw/cm 2 Operate Temp. Range 0 ~ +40°C The above equipment was tested by A Test Lab T echno Corp. For compliance with the requirements set forth in 47 CFR § 2.1091 / 47 CFR § 1.1310. The results of testing in this report apply only to the product/system, which was tested. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. EUT Modify Description : Modify Description: (1)The differences between the original EUT and new one: a. Remove a USB Port, a Ethernet RJ45 Port, HW Watchdog IC, Scanning Radio, Flash NOR and Bluetooth LE function. b. In new one, DDR4 RAM is 1 GB. (2)Update applicant name, applicant address, manufacture name, manufacture address, product type, model number, trade name, FCC ID and product’s appearance. After the verification of worst cast of AC Power Conducted Emission and Transmitter Radiated Emissions, all test data can be referred to the original report and showed in this report. Original Report : 2007FS16 Rev.01 Modify: 2007FS18 Rev.00 Report Number: 2007FS18 Rev.01 Page 6 of 13 3. Human Exposure Assessment Due to the design and installation of this product, it is not pos…
Text truncated - open the document above for the full version.
Note: 1.The test results are valid only for samples provided by customers and under the test conditions described in this report. 2.This report shall not be reproduced except in full, without the written approval of A Test Lab Technology Corporation. 3.The relevant information is provided by customers in this test report. According to the correctness, appropriateness or completeness of the information provided by the customer, if there is any doubt or error in the information which affects the validity of the test results, the laboratory does not take the responsibility. RF Test Report Applicant : Draytek Corporation Product Type : 11ax Ceiling AP Trade Name : DrayTek Model Number : VigorAP 1060C Applicable Standard : FCC 47 CFR PART 15 SUBPART C ANSI C63.10:2013 Received Date : May 13, 2020 Test Period : Jun. 03 ~ Oct. 23, 2020 Issued Date : Nov. 12, 2020 Issued by A Test Lab Techno Corp. No. 140-1, Changan Street, Bade District, Taoyuan City 33465, Taiwan (R.O.C.) Tel:+886-3-2710188 / Fax:+886-3-2710190 Taiwan Accreditation Foundation accreditation number: 1330 Test Firm MRA designation number: TW0010 Frequency Range : 9 kHz to 40 GHz Report Number2007FR30 Rev.01 Page 1 of 425 Revision History Rev. Issued Date Revisions Revised By 00 Nov. 04, 2020 Initial Issue Yu Chiang 01 Nov. 12, 2020 Revised 3.1 chapter(P.9) Revised 3.4 chapter(P.19) Revised 4.5 chapter(P.29) Revised Test Setup Photographs Yu Chiang Report Number2007FR30 Rev.01 Page 2 of 425 Ve r i f i c a t i o n o f C o m p l i a n c e Applicant : Draytek Corporation Product Type : 11ax Ceiling AP Trade Name : DrayTek Model Number : VigorAP 1060C FCC ID : VGYAP1060C EUT Rated Voltage : DC 12 V, 2.5 A (DC Power Adapter) DC 54 V, 0.6 A (PoE injector (802.3af/at)) Test Voltage : 120 Vac / 60 Hz Applicable Standard : FCC 47 CFR PART 15 SUBPART C ANSI C63.10:2013 Test Result : Complied Performing Lab. : A Test Lab Techno Corp. No. 140-1, Changan Street, Bade District, Taoyuan City 33465, Taiwan (R.O.C.) Tel:+886-3-2710188 / Fax:+886-3-2710190 Taiwan Accreditation Foundation accreditation number: 1330 http://www.atl-lab.com.tw/e-index.htm A Test Lab Techno Corp. tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by A Test Lab Techno Corp. based on interpretations and/or observations of test results. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Approved By : (Manager) (Ken Yang) Report Number2007FR30 Rev.01 Page 3 of 425 TABLE OF CONTENTS 1 General Information ......................................................................................................... 5 1.1. Summary of Test Result ............................................................................................. 5 1.2. Measurement Uncertainty .......................................................................................... 6 2 EUT Description................................................................................................................ 7 3 Test Methodology ............................................................................................................. 9 3.1. Mode of Operation ...................................................................................................... 9 3.2. EUT Test Step ........................................................................................................... 16 3.3. Configuration of Test System Details ........................................................................ 17 3.4. Test Instruments ....................................................................................................... 19 3.5. Test Site Environment............................................................................................... 20 4 Measurement Procedure ................................................................................................ 21 4.1. AC Power Line Conducted Emission Measurement ................................................. 21 4.2. Radiated Emission Measurement ............................................................................. 23 4.3. Maximum Conducted Output Power Measurement .................................................. 27 4.4. 6 dB RF Bandwidth Measurement ............................................................................ 28 4.5. Maximum Power Spectral Density Measurement ..................................................... 29 4.6. Out of Band Conducted Emissions Measurement .................................................... 31 4.7. Antenna Measurement ............................................................................................. 32 5 Test Results .................................................................................................................... 33 Annex A. Conducted Emission ......................................................................................... 33 Annex B. Conducted Test Results .................................................................................... 35 Annex C. Radiated Emission Measurement ................................................................... 240 Report Number2007FR30 Rev.01 Page 4 of 425 1 General Information 1.1. Summary of Test Result Standard Item Result Remark 15.207 AC Power Conducted Emission PASS ----- 15.247(d) Transmitter Radiated Emissions PASS ----- 15.247(b)(3) Max. Output Power PASS ----- 15.247(a)(2) 6 dB RF Bandwidth PASS ----- 15.247(e) Maximum Power Spectral Density PASS ----- 15.247(d) Out of Band Conducted Spurious Emission PASS ----- 15.203 Antenna Requirement PASS ----- Standard Description CFR47, Part 15, Subpart C Intentional Radiators ANSI C63. 10: 2013 American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices KDB 558074 D01 15.247 Meas Guidance v05r02 GUIDANCE FOR COMPLIANCE MEASUREM…
Text truncated - open the document above for the full version.
Mode 4: IEEE 802.11n 2.4 GHz 20 MHz Continuous TX mode_ANT-3 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 81 of 425 Mode 5: IEEE 802.11n 2.4 GHz 40 MHz Continuous TX mode_ANT-3 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 82 of 425 Mode 6: IEEE 802.11ax 2.4 GHz 20 MHz Continuous TX mode_ANT-3 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 83 of 425 Mode 7: IEEE 802.11ax 2.4 GHz 40 MHz Continuous TX mode_ANT-3 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 84 of 425 Maximum Power Spectral Density Measurement ANT-0 Test Mode Frequency (MHz) Measurement (dBm/3 kHz) Limit (dBm/ 3 kHz) Mode 3 2412 -9.455 ≤ 3.74 2437 -7.305 ≤ 3.74 2462 -9.377 ≤ 3.74 Mode 4 2412 -8.160 ≤ 8 2437 -6.260 ≤ 8 2462 -8.853 ≤ 8 Mode 5 2422 -11.713 ≤ 8 2437 -10.316 ≤ 8 2452 -11.891 ≤ 8 Mode 6 2412 -9.465 ≤ 8 2437 -6.663 ≤ 8 2462 -11.598 ≤ 8 Mode 7 2422 -13.591 ≤ 8 2437 -12.182 ≤ 8 2452 -14.360 ≤ 8 Report Number2007FR30 Rev.01 Page 85 of 425 ANT-1 Test Mode Frequency (MHz) Measurement (dBm/3 kHz) Limit (dBm/ 3 kHz) Mode 2 2412 -2.877 ≤ 8 2437 -3.006 ≤ 8 2462 -3.323 ≤ 8 Mode 3 2412 -8.801 ≤ 3.74 2437 -6.666 ≤ 3.74 2462 -8.744 ≤ 3.74 Mode 4 2412 -8.597 ≤ 8 2437 -6.294 ≤ 8 2462 -7.984 ≤ 8 Mode 5 2422 -10.686 ≤ 8 2437 -10.386 ≤ 8 2452 -12.632 ≤ 8 Mode 6 2412 -9.088 ≤ 8 2437 -6.632 ≤ 8 2462 -11.369 ≤ 8 Mode 7 2422 -13.557 ≤ 8 2437 -12.333 ≤ 8 2452 -14.359 ≤ 8 Report Number2007FR30 Rev.01 Page 86 of 425 ANT-2 Test Mode Frequency (MHz) Measurement (dBm/3 kHz) Limit (dBm/ 3 kHz) Mode 3 2412 -9.549 ≤ 3.74 2437 -7.449 ≤ 3.74 2462 -8.952 ≤ 3.74 Mode 4 2412 -9.130 ≤ 8 2437 -6.777 ≤ 8 2462 -9.387 ≤ 8 Mode 5 2422 -12.052 ≤ 8 2437 -11.014 ≤ 8 2452 -12.735 ≤ 8 Mode 6 2412 -9.682 ≤ 8 2437 -6.991 ≤ 8 2462 -11.492 ≤ 8 Mode 7 2422 -13.102 ≤ 8 2437 -12.135 ≤ 8 2452 -14.146 ≤ 8 ANT-3 Test Mode Frequency (MHz) Measurement (dBm/3 kHz) Limit (dBm/ 3 kHz) Mode 3 2412 -9.357 ≤ 3.74 2437 -7.830 ≤ 3.74 2462 -8.755 ≤ 3.74 Mode 4 2412 -8.972 ≤ 8 2437 -6.940 ≤ 8 2462 -9.011 ≤ 8 Mode 5 2422 -11.395 ≤ 8 2437 -10.217 ≤ 8 2452 -12.775 ≤ 8 Mode 6 2412 -9.346 ≤ 8 2437 -6.976 ≤ 8 2462 -11.392 ≤ 8 Mode 7 2422 -12.820 ≤ 8 2437 -11.992 ≤ 8 2452 -14.121 ≤ 8 Report Number2007FR30 Rev.01 Page 87 of 425 ANT-0+1+2+3 Test Mode Frequency (MHz) Measurement (dBm/3 kHz) Limit (dBm/ 3 kHz) Mode 3 2412 -3.260 ≤ 3.74 2437 -1.271 ≤ 3.74 2462 -2.929 ≤ 3.74 Mode 4 2412 -2.678 ≤ 8 2437 -0.537 ≤ 8 2462 -2.757 ≤ 8 Mode 5 2422 -5.411 ≤ 8 2437 -4.452 ≤ 8 2452 -6.472 ≤ 8 Mode 6 2412 -3.369 ≤ 8 2437 -0.792 ≤ 8 2462 -5.441 ≤ 8 Mode 7 2422 -7.235 ≤ 8 2437 -6.138 ≤ 8 2452 -8.224 ≤ 8 Report Number2007FR30 Rev.01 Page 88 of 425 Beamforming on ANT-0 Test Mode Frequency (MHz) Measurement (dBm/3 kHz) Limit (dBm/ 3 kHz) Mode 4 2412 -15.310 ≤ 3.74 2437 -13.218 ≤ 3.74 2462 -15.182 ≤ 3.74 Mode 5 2422 -18.032 ≤ 3.74 2437 -17.001 ≤ 3.74 2452 -19.091 ≤ 3.74 Mode 6 2412 -16.039 ≤ 3.74 2437 -12.991 ≤ 3.74 2462 -17.987 ≤ 3.74 Mode 7 2422 -19.322 ≤ 3.74 2437 -18.549 ≤ 3.74 2452 -20.009 ≤ 3.74 ANT-1 Test Mode Frequency (MHz) Measurement (dBm/3 kHz) Limit (dBm/ 3 kHz) Mode 4 2412 -15.106 ≤ 3.74 2437 -13.558 ≤ 3.74 2462 -15.940 ≤ 3.74 Mode 5 2422 -17.975 ≤ 3.74 2437 -17.203 ≤ 3.74 2452 -19.403 ≤ 3.74 Mode 6 2412 -16.127 ≤ 3.74 2437 -12.901 ≤ 3.74 2462 -18.151 ≤ 3.74 Mode 7 2422 -18.257 ≤ 3.74 2437 -19.024 ≤ 3.74 2452 -20.170 ≤ 3.74 Report Number2007FR30 Rev.01 Page 89 of 425 ANT-2 Test Mode Frequency (MHz) Measurement (dBm/3 kHz) Limit (dBm/ 3 kHz) Mode 4 2412 -15.487 ≤ 3.74 2437 -12.908 ≤ 3.74 2462 -16.052 ≤ 3.74 Mode 5 2422 -18.180 ≤ 3.74 2437 -16.901 ≤ 3.74 2452 -19.465 ≤ 3.74 Mode 6 2412 -16.577 ≤ 3.74 2437 -12.817 ≤ 3.74 2462 -17.584 ≤ 3.74 Mode 7 2422 -19.263 ≤ 3.74 2437 -18.599 ≤ 3.74 2452 -20.184 ≤ 3.74 ANT-3 Test Mode Frequency (MHz) Measurement (dBm/3 kHz) Limit (dBm/ 3 kHz) Mode 4 2412 -15.589 ≤ 3.74 2437 -13.132 ≤ 3.74 2462 -15.603 ≤ 3.74 Mode 5 2422 -18.062 ≤ 3.74 2437 -17.721 ≤ 3.74 2452 -19.604 ≤ 3.74 Mode 6 2412 -15.531 ≤ 3.74 2437 -12.866 ≤ 3.74 2462 -17.786 ≤ 3.74 Mode 7 2422 -19.394 ≤ 3.74 2437 -18.139 ≤ 3.74 2452 -20.070 ≤ 3.74 Report Number2007FR30 Rev.01 Page 90 of 425 ANT-0+1+2+3 Test Mode Frequency (MHz) Measurement (dBm/3 kHz) Limit (dBm/ 3 kHz) Mode 4 2412 -9.349 ≤ 3.74 2437 -7.177 ≤ 3.74 2462 -9.660 ≤ 3.74 Mode 5 2422 -12.041 ≤ 3.74 2437 -11.175 ≤ 3.74 2452 -13.366 ≤ 3.74 Mode 6 2412 -10.032 ≤ 3.74 2437 -6.873 ≤ 3.74 2462 -11.851 ≤ 3.74 Mode 7 2422 -13.012 ≤ 3.74 2437 -12.546 ≤ 3.74 2452 -14.087 ≤ 3.74 Report Number2007FR30 Rev.01 Page 91 of 425 Mode 3: IEEE 802.11g Continuous TX mode_ANT-0 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 92 of 425 Mode 4: IEEE 802.11n 2.4 GHz 20 MHz Continuous TX mode_ANT-0 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 93 of 425 Mode 5: IEEE 802.11n 2.4 GHz 40 MHz Continuous TX mode_ANT-0 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 94 of 425 Mode 6: IEEE 802.11ax 2.4 GHz 20 MHz Continuous TX mode_ANT-0 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 95 of 425 Mode 7: IEEE 802.11ax 2.4 GHz 40 MHz Continuous TX mode_ANT-0 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 96 of 425 Mode 2: IEEE 802.11b Continuous TX mode_ANT-1 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 97 of 425 Mode 3: IEEE 802.11g Continuous TX mode_ANT-1 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 98 of 425 Mode 4: IEEE 802.11n 2.4 GHz 20 MHz Continuous TX mode_ANT-1 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 99 of 425 Mode 5: IEEE 802.11n 2.4 GHz 40 MHz Continuous TX mode_ANT-1 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 100 of 425 Mode 6: IEEE 802.11ax 2.4 GHz 20 MHz Continuous TX mode_ANT-1 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 101 of 425 Mode 7: IEEE 802.11ax 2.4 GHz 40 MHz Continuous TX mode_ANT-1 2422 MHz 1 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 102 of 425 Mode 3: IEEE 802.11g Continuous TX mode_ANT-2 2412 MHz 2437 MHz 2462 MHz Report Number2…
Text truncated - open the document above for the full version.
Mode 3: IEEE 802.11g Continuous TX mode_ANT-1 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 135 of 425 Mode 4: IEEE 802.11n 2.4 GHz 20 MHz Continuous TX mode_ANT-1 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 136 of 425 Mode 5: IEEE 802.11n 2.4 GHz 40 MHz Continuous TX mode_ANT-1 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 137 of 425 Mode 6: IEEE 802.11ax 2.4 GHz 20 MHz Continuous TX mode_ANT-1 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 138 of 425 Mode 7: IEEE 802.11ax 2.4 GHz 40 MHz Continuous TX mode_ANT-1 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 139 of 425 Mode 3: IEEE 802.11g Continuous TX mode_ANT-2 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 140 of 425 Mode 4: IEEE 802.11n 2.4 GHz 20 MHz Continuous TX mode_ANT-2 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 141 of 425 Mode 5: IEEE 802.11n 2.4 GHz 40 MHz Continuous TX mode_ANT-2 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 142 of 425 Mode 6: IEEE 802.11ax 2.4 GHz 20 MHz Continuous TX mode_ANT-2 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 143 of 425 Mode 7: IEEE 802.11ax 2.4 GHz 40 MHz Continuous TX mode_ANT-2 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 144 of 425 Mode 3: IEEE 802.11g Continuous TX mode_ANT-3 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 145 of 425 Mode 4: IEEE 802.11n 2.4 GHz 20 MHz Continuous TX mode_ANT-3 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 146 of 425 Mode 5: IEEE 802.11n 2.4 GHz 40 MHz Continuous TX mode_ANT-3 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 147 of 425 Mode 6: IEEE 802.11ax 2.4 GHz 20 MHz Continuous TX mode_ANT-3 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 148 of 425 Mode 7: IEEE 802.11ax 2.4 GHz 40 MHz Continuous TX mode_ANT-3 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 149 of 425 Beamforming on Reference level Mode 4: IEEE 802.11n 2.4 GHz 20 MHz Continuous TX mode_ANT-0 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 150 of 425 Mode 5: IEEE 802.11n 2.4 GHz 40 MHz Continuous TX mode_ANT-0 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 151 of 425 Mode 6: IEEE 802.11ax 2.4 GHz 20 MHz Continuous TX mode_ANT-0 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 152 of 425 Mode 7: IEEE 802.11ax 2.4 GHz 40 MHz Continuous TX mode_ANT-0 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 153 of 425 Mode 4: IEEE 802.11n 2.4 GHz 20 MHz Continuous TX mode_ANT-1 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 154 of 425 Mode 5: IEEE 802.11n 2.4 GHz 40 MHz Continuous TX mode_ANT-1 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 155 of 425 Mode 6: IEEE 802.11ax 2.4 GHz 20 MHz Continuous TX mode_ANT-1 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 156 of 425 Mode 7: IEEE 802.11ax 2.4 GHz 40 MHz Continuous TX mode_ANT-1 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 157 of 425 Mode 4: IEEE 802.11n 2.4 GHz 20 MHz Continuous TX mode_ANT-2 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 158 of 425 Mode 5: IEEE 802.11n 2.4 GHz 40 MHz Continuous TX mode_ANT-2 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 159 of 425 Mode 6: IEEE 802.11ax 2.4 GHz 20 MHz Continuous TX mode_ANT-2 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 160 of 425 Mode 7: IEEE 802.11ax 2.4 GHz 40 MHz Continuous TX mode_ANT-2 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 161 of 425 Mode 4: IEEE 802.11n 2.4 GHz 20 MHz Continuous TX mode_ANT-3 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 162 of 425 Mode 5: IEEE 802.11n 2.4 GHz 40 MHz Continuous TX mode_ANT-3 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 163 of 425 Mode 6: IEEE 802.11ax 2.4 GHz 20 MHz Continuous TX mode_ANT-3 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 164 of 425 Mode 7: IEEE 802.11ax 2.4 GHz 40 MHz Continuous TX mode_ANT-3 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 165 of 425 Out of Band Conducted Emissions Mode 3: IEEE 802.11g Continuous TX mode_ANT-0 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 166 of 425 Mode 4: IEEE 802.11n 2.4 GHz 20 MHz Continuous TX mode_ANT-0 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 167 of 425 Mode 5: IEEE 802.11n 2.4 GHz 40 MHz Continuous TX mode_ANT-0 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 168 of 425 Mode 6: IEEE 802.11ax 2.4 GHz 20 MHz Continuous TX mode_ANT-0 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 169 of 425 Mode 7: IEEE 802.11ax 2.4 GHz 40 MHz Continuous TX mode_ANT-0 2422 MHz 2437 MHz 2452 MHz Report Number2007FR30 Rev.01 Page 170 of 425 Mode 2: IEEE 802.11b Continuous TX mode_ANT-1 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30 Rev.01 Page 171 of 425 Mode 3: IEEE 802.11g Continuous TX mode_ANT-1 2412 MHz 2437 MHz 2462 MHz Report Number2007FR30…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 334.00 mW |
VigorAP 1070C 802.11be Ceiling-mount Access Point
Equipment Class
NII - Unlicensed National Information Infrastructure TX
35b Security Router, Gigabit Broadband Router
Equipment Class
NII - Unlicensed National Information Infrastructure TX
802.11ax Ceiling-mount Access Point
Equipment Class
NII - Unlicensed National Information Infrastructure TX
802.11ax Ceiling-mount AP
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Vigor Router 11ax Series
Equipment Class
DTS - Digital Transmission System