Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
February 14th, 2008 NEC Corporation of America RCSD 2816 Towerview Rd. Herndon, VA 20171 To Whom It May Concern: "All of the circuitry in each of the NEC Model H2600 5.8 GHz Out Door Units (ODUs) is identical except for mechanical filters installed at the time of manufacture" The preceding statement is in reference to the NLite L 5.8 GHz radio (TRP-6GAA-25, NEC part # H2600). The six variants of the NEC 5.8 GHz ODU (H2600) (SubBand A Low, SubBand A High, SubBand B Low, SubBand B High, SubBand C Low and SubBand C High) are physically identical except for mechanical filters installed in the ODU at the time of manufacture. The ODU is then sealed at the factory and it's subband identified with a placard attached to the unit. Mark Cowles Senior Project Engineer RCSD NEC Corporation of America
MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ! BALTIMORE, MARYLAND 21230-3432 ! PHONE (410) 354-3300 ! FAX (410) 354-3313 The Nationβs First Licensed Nationally Recognized Testing Laboratory February 1, 2008 NEC America, Inc. 6535 N. State Highway 161 Irving, TX 750392402 Dear Mark Cowles, Enclosed is the Wireless test report for compliance testing of the NEC America, Inc., MDP-15MB5T-1A/D as tested to the requirements of Title 47 of the CFR, Ch. 1 (10-1-06 ed.), Part 15, Subpart B for a Class B Digital Device and Subpart C for Intentional Radiators. Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or if MET can be of further service to you, please feel free to contact me. Sincerely yours, MET LABORATORIES, INC. Jennifer Sanchez Documentation Department Reference: (\NEC America, Inc.\EMC23942A-FCC247) Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. While use of the National Voluntary Laboratory Accreditation Program (NVLAP) letters or the NVLAP Logo, the Standards Council of Canada Logo, or the Nationally Recognized Testing Laboratory (NRTL) Letters in this report reflects MET Accreditation under these programs, these letters, logo, or statements do not claim product endorsement by NVLAP or any Agency of the U.S. Government. This letter of transmittal is not a part of the attached report. MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ! BALTIMORE, MARYLAND 21230-3432 ! PHONE (410) 354-3300 ! FAX (410) 354-3313 MET Report: EMC23942A-FCC247 Β© 2008, MET Laboratories, Inc. Page ii of vii Electromagnetic Compatibility Criteria Test Report for the NEC America, Inc. Model MDP-15MB5T-1A/D Tested under the FCC Certification Rules contained in Title 47 of the CFR, Part 15.247, Subpart C for Intentional Radiators MET Report: EMC23942A-FCC247 February 1, 2008 Prepared For: NEC America, Inc. 6535 N. State Highway 161 Irving, TX 750392402 Prepared By: MET Laboratories, Inc. 914 W. Patapsco Ave Baltimore, MD 21230 Electromagnetic Compatibility NEC America, Inc. Cover Page MDP-15MB5T-1A/D CFR Title 47, Part 15B, 15.247 MET Report: EMC23942A-FCC247 Β© 2008, MET Laboratories, Inc. Page iii of vii Electromagnetic Compatibility Criteria Test Report for the NEC America, Inc. Model MDP-15MB5T-1A/D Tested Under the FCC Certification Rules contained in Title 47 of the CFR, Part 15.247, Subpart C for Intentional Radiators Dusmantha Tennakoon, Project Engineer Jennifer Sanchez Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of Part 15.247, of the FCC Rules under normal use and maintenance. Shawn McMillen, Wireless Manager Electromagnetic Compatibility Lab Electromagnetic Compatibility NEC America, Inc. Report Status MDP-15MB5T-1A/D CFR Title 47, Part 15B, 15.247 MET Report: EMC23942A-FCC247 Β© 2008, MET Laboratories, Inc. Page iv of vii Report Status Sheet Revision Report Date Reason for Revision β February 1, 2008 Initial Issue. Electromagnetic Compatibility NEC America, Inc. Table of Contents MDP-15MB5T-1A/D CFR Title 47, Part 15B, 15.247 MET Report: EMC23942A-FCC247 Β© 2008, MET Laboratories, Inc. Page v of vii Table of Contents I. Executive Summary .................................................................................................................................................1 A. Purpose of Test ...................................................................................................................................................2 B. Executive Summary ............................................................................................................................................2 II. Equipment Configuration .......................................................................................................................................3 A. Overview.............................................................................................................................................................4 B. References...........................................................................................................................................................5 C. Test Site ..............................................................................................................................................................6 D. Description of Test Sample.................................................................................................................................6 E. Equipment Configuration....................................................................................................................................8 F. Ports and Cabling Information ............................................................................................................................8 G. Mode of Operation..............................................................................................................................................9 H. Modifications ......................................................................................................................................................9 a) Modifications to EUT....................................................................................................................9 b) Modifications to Test Standard...............β¦
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 5.73 GHz - 5.84 GHz | 963.00 mW |

NEC iPasolink Digital Microwave Radio
Equipment Class
DTS - Digital Transmission System
NLite N 5.8 GHz Digital Microwave Radio
Equipment Class
DTS - Digital Transmission System
5.8 GHz Unlicensed Digital Microwave Radio
Equipment Class
DTS - Digital Transmission System
5.8 GHz Unlicensed Digital Microwave Radio
Equipment Class
DTS - Digital Transmission System