FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. PEGATRON CORPORATION/
  3. VUIDALIW

VUIDALIWTablet Computer

PEGATRON CORPORATION
Tablet Computer - FCC ID VUIDALIW - PEGATRON CORPORATION
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Oct 30, 2012
Application Purpose
Original Equipment
Date of Application
Oct 30, 2012
Equipment Note
Tablet Computer
Frequency Range
13.56000000 - 13.56000000
Company
PEGATRON CORPORATION
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—
β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—
β†—

Internal Photos

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Declarations and Safety Statements Federal Communications Commission Statement This device complies with FCC Rules Part 15. Operation is subject to the following two conditions: β€’ This device may not cause harmful interference, and β€’ This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the Federal Communications Commission (FCC) rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: β€’ Reorient or relocate the receiving antenna. β€’ Increase the separation between the equipment and receiver. β€’ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. β€’ Consult the dealer or an experienced radio/TV technician for help. WARNING! The use of a shielded-type power cord is required in order to meet FCC emission limits and to prevent interference to the nearby radio and television reception. It is essential that only the supplied power cord be used. Use only shielded cables to connect I/O devices to this equipment. You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. (Reprinted from the Code of Federal Regulations #47, part 15.193, 1993. Washington DC: Office of the Federal Register, National Archives and Records Administration, U.S. Government Printing Office.) FCC Radio Frequency (RF) Exposure Caution Statement This equipment complies with FCC RF exposure limits set forth for an uncontrolled environment. To maintain compliance with FCC RF exposure compliance requirements, please follow operation instructions in the user guide. IMPORTANT: This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. NFC Baud Rates: 9600, 28800, 115200, 230400, 460800 Transmission modes: ISO/IEC 14443 A, ISO/IEC 14443 B, MIFARE, Sony FeliCa Operating ambient temp: 10Β°C to 70Β°C RF Clock: 13.56MHz This equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.

External Photos

Page 1 CONSTRUCTION PHOTOS OF EUT Page 2 Page 3 Page 4 Page 5

Internal Photos

Page 6 Page 7 Page 8 Page 9 Page 10

Test Report

Report No.: RF120919D05 1 of 28 Report Format Version 5.0.0 FCC TEST REPORT (RFID) REPORT NO.: RF120919D05 MODEL NO.: DaliW FCC ID: VUIDALIW RECEIVED: Sep. 19, 2012 TESTED: Oct. 5 ~ 7, 2012 ISSUED: Oct. 15, 2012 APPLICANT: PEGATRON CORPORATION ADDRESS: 5F, No. 76, Ligong ST., Beitou District, Taipei City, Taiwan (R.O.C.) ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the com pliance or non-compliance to the specification. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: RF120919D05 2 of 28 Report Format Version 5.0.0 Table of Contents RELEASE CONTROL RECORD ................................................................................. 3 1. CERTIFICATION ............................................................................................... 4 2. SUMMARY OF TEST RESULTS ...................................................................... 5 2.1 MEASUREMENT UNCERTAINTY .................................................................... 5 3. GENERAL INFORMATION ............................................................................... 6 3.1 GENERAL DESCRIPTION OF EUT ................................................................. 6 3.2 DESCRIPTION OF TEST MODES ................................................................... 7 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL .................... 7 3.3 DESCRIPTION OF SUPPORT UNITS ............................................................. 9 3.3.1 CONFIGURATION OF SYSTEM UNDER TEST ............................................... 9 3.4 GENERAL DESCRIPTION OF APPLIED STANDARDS ................................. 10 4. TEST TYPES AND RESULTS ........................................................................ 11 4.1 RADIATED EMISSION MEASUREMENT ....................................................... 11 4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT .................................... 11 4.1.2 TEST INSTRUMENTS .................................................................................... 12 4.1.3 TEST PROCEDURES .................................................................................... 13 4.1.4 DEVIATION FROM TEST STANDARD ........................................................... 13 4.1.5 TEST SETUP .................................................................................................. 14 4.1.6 EUT OPERATING CONDITIONS ................................................................... 14 4.1.7 TEST RESULTS ............................................................................................. 15 4.2 CONDUCTED EMISSION MEASUREMENT .................................................. 19 4.2.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ............................... 19 4.2.2 TEST INSTRUMENTS .................................................................................... 19 4.2.3 TEST PROCEDURES .................................................................................... 20 4.2.4 DEVIATION FROM TEST STANDARD ........................................................... 20 4.2.5 TEST SETUP .................................................................................................. 20 4.2.6 EUT OPERATING CONDITIONS ................................................................... 20 4.2.7 TEST RESULTS ............................................................................................. 21 4.3 FREQUENCY STABILITY ............................................................................... 23 4.3.1 LIMITS OF FREQUENCY STABILITY MEASUREMENT ................................ 23 4.3.2 TEST INSTRUMENTS .................................................................................... 23 4.3.3 TEST PROCEDURE ....................................................................................... 23 4.3.4 DEVIATION FROM TEST STANDARD ........................................................... 24 4.3.5 TEST SETUP .................................................................................................. 24 4.3.6 EUT OPERATING CONDITION ...................................................................... 24 4.3.7 TEST RESULTS ............................................................................................. 25 5. PHOTOGRAPHS OF THE TEST CONFIGURATION ..................................... 26 6. INFORMATION ON THE TESTING LABORATORIES .................................... 27 7. APPENDIX A - MODIFICATIONS RECORDERS FOR ENGINEERING CHAN…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: RF120919D05 1 of 2 Report Format Version 5.0.0 PHOTOGRAPHS OF THE TEST CONFIGURATION CONDUCTED EMISSION TEST Report No.: RF120919D05 2 of 2 Report Format Version 5.0.0 RADIATED EMISSION TEST

Contact Information

Applicant

Nancy Yu(Senior Manager)
[email protected]886-2-81439001Fax: 886-2-28960017

Test Firm

Bureau Veritas CPS (H.K.) Ltd., Taoyuan BranchRichard Chen
[email protected]+886-3-2600884Fax: +886-3-2115834

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term

Other Applications from PEGATRON CORPORATION

VUI-TS7A01

Hardware wallet

Nov 19, 2025

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
VUI-M2U350

5G FR2 ODU

Sep 09, 2024

Equipment Class

DTS - Digital Transmission System
VUIPR1400-48I

5G NR O-RU N48

Apr 14, 2024

Equipment Class

CBD - Citizens Band Category A and B Devices
Customer Facing Wi-Fi Module (CFWM) - FCC ID VUI-CFWM - PEGATRON CORPORATION
VUI-CFWM

Customer Facing Wi-Fi Module (CFWM)

Dec 10, 2022

Equipment Class

NII - Unlicensed National Information Infrastructure TX
IP Desktop Phone - FCC ID VUI-DPCP700X - PEGATRON CORPORATION
VUI-DPCP700X

IP Desktop Phone

May 26, 2020

Equipment Class

DTS - Digital Transmission System