Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Designed for high performance audio in a very compact package with simple and intuitive set up and daily control POWER KW-SB001 Contents 1 Important Important safety instructions 3 3 5 5 5 6 7 7 8 8 8 9 10 10 12 12 7 2 Your Soundbar System What’s in the box Introduction Overview of the main unit Overview of the remote control 3 Get started 4 Appendix 5 Specification Attach the stand Mount to a wall General Connect AUDIO devices Option 1: Connect this soundbar to an external device Option 2: Connect this soundbar to the TV set Activite wireless pairing EN 3 5 8 7 6 6 6 To connect exteral components Activate wireless pairing General Specification 1.Read these instructions – All the safety and operating instructions should be read before this product is operated. 2.Keep these instructions – The safety and operating instructions should be retained for future reference. 3.Heed all warnings – All warnings on the appliance and in the operating instructions should be adhered to. 4.Follow all instructions – All operating and use instructions should be followed. 5.Do not use this apparatus near water – The appliance should not be used near water or moisture – for example, in a wet bas ement or near a swimming pool, and the like. 6.Clean only with dry cloth. 7.Do not block any ventilation openings. Install in accordance with the manufacture’s instructions. 8.Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9.Do not defeat the safety purpose of the polarized or grounding plug. A polarized plug has two blades with one wider than the other. A grounding plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10. Protect the power cord frombeing walked on or pinched particularly at the plugs, convenience rec eptacles, and at the point where they exit fromthe apparatus. 11. Only use attachments/accessories specified by the manufacturer. 12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart or rack is used, use caution when moving the cart/apparatus combination to avoid injury fromtip-over. 13. Unplug the apparatus during lightning storms or when unused for long periods of time. 14. Refer all servicing to qualified personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. I 1 Important Important safety instruction EN-3 24. Caution: Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type. - Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: � Reorient or relocate the receiving antenna. � Increase the separation between the equipment and receiver. � Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. � Consult the dealer or an experienced radio/TV technician for help. � “FCC RF Radiation Exposure Statement Caution: To maintain compliance with the FCC’s RF exposure guidelines, place the product at least 20cm from nearby persons.” Overview of the main unit 6 9 10 11 12 13 7 8 MUTE button FX SURROUND button STANDBY button SOURCE button SUBWOOFER button VOLUME +/- button SPEAKER Turn on/off the system. Adjust the volume. Adjust the output level within the range of -6dB to +6dB. AV input socket. Turning off the sound temporarily. T o restore the sound, press the button again or adjust the volume. Listen to a more realistic sound than stereo sound. Select the input sound (AUX IN 1, AUX IN 2, AUX IN 3). 3 4 5 6 7 REMOTE SENSOR AUX IN 1 jack 8 9 AV input socket. AUX IN 2 jack 10 Connect audio output socket. AUX IN 3 jack 11 To pair speakers. PAIRING button 12 Inlet for power cord. AC MAINS 13 EN-6 Overview of the remote control MUTE button FX SURROUND button STANDBY button SOURCE button SUBWOOFER VOLUME button VOLUME +/- button Turn on/off the system. Adjust the volume. Adjust the output level within the range of -6dB to +6dB. Turning off the sound temporarily. T o restore the sound, press the button again or adjust the volume. Listen to a more realistic sound than stereo sound. Select the input sound (AUX IN 1, AUX IN 2, AUX IN 3). 2 1 5 6 3 4 1 2 3 4 5 6 POWER Attach the stand 1 Place the supplied table stand onto the rear of the main unit until the hook enter the hole of the main unit completely. 2 Slide the supplied table stand upward along the hole of the main unit. 3 Get started EN-7 You can also connect the red/white audio Press SOURCE button on the wireless sound system to select”AUX IN 1 or 2” input. connectors of the AV cable from the TV to a set of audio input sockets. Note It is unnecessary to connect the yellow video • connectors. Connect AUDIO devices Note The…
Text truncated - open the document above for the full version.
建 榮 企 業 (香 港) 有 限 公 司 KENWIN INDUSTRIAL (H.K.) LTD. 香 港 新 界 火 炭 山 尾 街 18 - 24 號 沙 田 商 業 中 心 1 5 樓 1 5 1 2,15,17&19 室 Rm 1512, 15,17&19,15/F., Shatin Galleria, 18-24 Shan Mei Street, Fotan, N.T., Hong Kong. Tel: (852) 2690 1380 Fax: (852) 2690 1081 Web-site: http://www.kenwin.com.hk Email: [email protected] 24 th May 2010 To whom it may concern, Letter of Agency I, an officer of KENWIN INDUSTRIAL (H.K.) LTD. do hereby authorize Intertek Testing Services (Mr. Shawn Xing) to act on our behalf in front of the Federal Communications Commission with respect to all matters relating to certification of equipment under Part 15 and/or Part 95 of the FCC Rules until further notice. I further certify that no party (as defined in §1.2002(b) of CFR 47, 2007) to this application, including myself, is subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C., 862. Regards, Ambert Fok Sales Manager
KENWIN INDUSTRIAL (H.K.) LTD. 建 榮 企 業 (香 港) 有 限 公 司 香 港 新 界 火 炭 山 尾 街 18 - 24 號 沙 田 商 業 中 心 1 5 樓 1 5 1 2 室 Tel : (852) 2690 1380 Rm 1512, 15/F., Shatin Galleria, 18-24 Shan Mei Street, Fotan, N.T., Hong Kong. Fax: (852) 2690 1081 Web-site: http://www.kenwin.com.hk Email: [email protected] 24 th May 2010 To whom it may concern, Request for Permanent Confidentiality Under FCC Part 15 Certification FCC ID: VWPKENWIN0000 5 Request is hereby submitted by Kenwin Industrial (H.K.) Ltd. to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR § 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential and Kenwin Industrial (H.K.) Ltd. reserves the right to discern which parties can obtain access to these information: Schematics Detailed Block diagrams Detailed Operational/Functional Description The rationale for request for confidentiality is as followings: This information represents intellectual property of Kenwin Industrial (H.K.) Ltd. and it is subject to competition. We have invested considerable time and materials in research and development to produce the referenced product. Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us. If you have questions or need further information, please contact the undersigned. Regards, Print name: Ambert Fok Title: Sales Manager
External Photos
5341 2 24mm31mm 50mm69mm 1 2 59 5 34.5mm 12mm 59.5mm 59.5mm R3mm 8 3 4 10mm 5 8mm
Internal Photos (Bottom side of RF module)
RF Exposures Evaluation For Maximum Permissible Exposure (MPE) evaluation of the product, the maximum power density at 20 cm from this transmitter shall be less than the General Population / Uncontrolled MPE limit in OET Bulletin 65. For the product of tested model of SBW100, the measured maximum field strength measured (FS) was 111.4 dBμV/m (RBW=10 MHz, radiated measurement). The distance (D) between the antenna and the equipment under test (EUT) was 3 meters. And the maximum source-based time-averaging duty factor is 12.698 %. From these data, the exposed power density at a distance (R) of 20cm from the center of radiation of the antenna can be calculated according to OET Bulletin 65 as follow: The radiated power = (FS*D) ^2 / 30 =41.4 mW The radiated (EIRP) source-based time-averaging output power = (41.4* 0.12698)mW = 5.25697mW The power density at 20 cm from the antenna = EIRP / 4πR^2 = 0.0010 mW/cm^2 In the frequency range of 1,500 - 100,000MHz, the MPE limit is 1.0 mWcm-2 for general population and uncontrolled exposure. As the measured power density at 20cm from the transmitter is lower than the MPE limit, the compliance to the MPE limit can be ensured by indicating the minimum 20cm separation between the transmitter's radiating structures and body of the user or nearby persons. The following RF exposure statement is proposed to be included in the user manual: “FCC RF Radiation Exposure Statement Caution: To maintain compliance with the FCC’s RF exposure guidelines, place the product at least 20cm from nearby persons.”
A Ref 10 dBmAtt 20 dB * 2.5 MHz/Center 2.412 GHzSpan 25 MHz * * 3DB RBW 100 kHz VBW 300 kHz SWT 10 ms MAXH 1 PK -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -3.39 dBm 2.412725000 GHz 2 Delta 2 [T1 ] -6.15 dB -5.570000000 MHz 3 Delta 3 [T1 ] -6.16 dB 4.170000000 MHz D1 -9.39 dBm Plot: B2A1 A Ref 10 dBmAtt 20 dB * 2.5 MHz/Center 2.438 GHzSpan 25 MHz * * 3DB RBW 100 kHz VBW 300 kHz SWT 10 ms 1 PK MAXH -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -4.25 dBm 2.438762500 GHz 2 Delta 2 [T1 ] -6.35 dB -5.620000000 MHz 3 Delta 3 [T1 ] -6.13 dB 4.140000000 MHz D1 -10.25 dBm Plot: B2B1 A Ref 10 dBmAtt 20 dB * 2.5 MHz/Center 2.464 GHzSpan 25 MHz * * 3DB RBW 100 kHz VBW 300 kHz SWT 10 ms 1 PK MAXH -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -4.79 dBm 2.464750000 GHz 2 Delta 2 [T1 ] -5.83 dB -5.575000000 MHz 3 Delta 3 [T1 ] -5.95 dB 4.125000000 MHz D1 -10.79 dBm Plot: B2C1
Average Factor Calculation: Ref 20 dBmAtt 30 dB * A MAXH SGL * 3DB RBW 3 MHz VBW 3 MHz Center 2.464 GHz10 ms/ SWT 100 ms 1 PK -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 1 Marker 1 [T1 ] 5.01 dBm 24.800000 ms 1 Delta 1 [T1 ] 0.02 dB 2.600000 ms Ref 20 dBmAtt 30 dB * A MAXH SGL * 3DB RBW 3 MHz VBW 3 MHz Center 2.464 GHz1 ms/ SWT 10 ms 1 PK -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 1 Marker 1 [T1 ] 0.86 dBm 3.620000 ms 1 Delta 1 [T1 ] 0.01 dB 2.520000 ms Ref 20 dBmAtt 30 dB * A MAXH SGL * 3DB RBW 3 MHz VBW 3 MHz Center 2.464 GHz1 ms/ SWT 10 ms 1 PK -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 1 Marker 1 [T1 ] 0.86 dBm 3.620000 ms 1 Delta 1 [T1 ] 1.43 dB 320.000000 μs The duration of one cycle = 2.52 ms Effective period of the cycle = 320us Duty Cycle = 320us / 2.52 ms = 0.12698 or 12.698% Therefore, the averaging factor is found by 20 log 10 0.12698 = -17.9 dB
A * 3DB RBW 10 MHz SWT 10 ms * VBW 10 MHz Att 30 dB * Ref 20 dBm Center 2.412 GHzSpan 50 MHz5 MHz/ 1 PK MAXH -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 1 Marker 1 [T1 ] 13.16 dBm 2.411950000 GHz Plot: B1A1 A Att 30 dB * Ref 20 dBm 5 MHz/Center 2.438 GHzSpan 50 MHz * * 3DB RBW 10 MHz VBW 10 MHz SWT 10 ms 1 PK MAXH -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 1 Marker 1 [T1 ] 12.49 dBm 2.438275000 GHz Plot: B1B1 A Att 30 dB * Ref 20 dBm 5 MHz/Center 2.464 GHzSpan 50 MHz * * 3DB RBW 10 MHz VBW 10 MHz SWT 10 ms 1 PK MAXH -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 1 Marker 1 [T1 ] 11.55 dBm 2.464275000 GHz Plot: B1C1
A Ref 10 dBmAtt 20 dB ** MAXH 1 PK 1.5 kHz/Center 2.411309112 GHzSpan 15 kHz * * 3DB RBW 3 kHz VBW 10 kHz SWT 5 s * -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -4.82 dBm 2.411309113 GHz Plot: B3A1 Ref 10 dBmAtt 20 dB ** A 1 PK MAXH Center 2.437303613 GHzSpan 15 kHz1.5 kHz/ * * 3DB RBW 3 kHz VBW 10 kHz SWT 5 s * -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -5.50 dBm 2.437303613 GHz Plot: B3B1 A Ref 10 dBmAtt 20 dB ** 1.5 kHz/Center 2.46331 GHzSpan 15 kHz * * 3DB RBW 3 kHz VBW 10 kHz SWT 5 s * 1 PK MAXH -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -6.34 dBm 2.463309970 GHz Plot: B3C1
A Ref 10 dBmAtt 20 dB * MAXH 1 PK * * 3DB RBW 100 kHz VBW 300 kHz SWT 250 ms Start 1 MHzStop 2.5 GHz249.9 MHz/ -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -3.52 dBm 2.412535000 GHz 1 Delta 1 [T1 ] -41.72 dB -1.739304000 GHz Plot: B4A1 A Ref 10 dBmAtt 20 dB * MAXH 1 PK 2.3 GHz/Start 2 GHzStop 25 GHz * * 3DB RBW 100 kHz VBW 300 kHz SWT 2.3 s -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -3.69 dBm 2.402500000 GHz 1 Delta 1 [T1 ] -44.12 dB 805.000000000 MHz Plot: B4A2 A Ref 10 dBmAtt 20 dB * 249.9 MHz/Start 1 MHzStop 2.5 GHz * * 3DB RBW 100 kHz VBW 300 kHz SWT 250 ms 1 PK MAXH -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -4.14 dBm 2.440024000 GHz 1 Delta 1 [T1 ] -41.57 dB -1.740553500 GHz Plot: B4B1 A Ref 10 dBmAtt 20 dB * 2.3 GHz/Start 2 GHzStop 25 GHz * * 3DB RBW 100 kHz VBW 300 kHz SWT 2.3 s 1 PK MAXH -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -4.53 dBm 2.437000000 GHz 1 Delta 1 [T1 ] -43.30 dB 805.000000000 MHz Plot: B4B2 A Ref 10 dBmAtt 20 dB * 249.9 MHz/Start 1 MHzStop 2.5 GHz * * 3DB RBW 100 kHz VBW 300 kHz SWT 250 ms 1 PK MAXH -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -5.43 dBm 2.465014000 GHz 1 Delta 1 [T1 ] -42.10 dB -1.739304000 GHz Plot: B4C1 A Ref 10 dBmAtt 20 dB * 1 PK MAXH 2.3 GHz/Start 2 GHzStop 25 GHz * * 3DB RBW 100 kHz VBW 300 kHz SWT 2.3 s -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -5.12 dBm 2.460000000 GHz 1 Delta 1 [T1 ] -43.01 dB 816.500000000 MHz Plot: B4C2 A Ref 10 dBmAtt 20 dB * 3 MHz/Center 2.4 GHzSpan 30 MHz * * 3DB RBW 300 kHz VBW 1 MHz SWT 10 ms 1 PK MAXH -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] 1.74 dB m 2.411535000 GHz 1 Delta 1 [T1 ] -36.29 dB -12.045000000 MHz Plot: B4D1 A Ref 10 dBmAtt 20 dB * 10 MHz/Center 2.4835 GHzSpan 100 MHz * * 3DB RBW 1 MHz VBW 3 MHz SWT 10 ms 1 PK MAXH -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] 4.24 dB m 2.463000000 GHz 1 Delta 1 [T1 ] -49.57 dB 20.800000000 MHz Plot: B4D2
Intertek Testing Services Shenzhen Ltd. Kejiyuan Branch 6F, D Block, Huahan Building, Langshan Road, Nanshan District, Shenzhen, P. R. China Tel: (86 755) 8601 6288 Fax: (86 755) 8601 6751 Website: www.china.intertek-etlsemko.com August 16, 2010 KENWIN INDUSTRIAL (H.K.) LTD. Rm. 1512, 15, 17&19, 15/F., Shatin Galleria, 18-24 Shan Mei St., Fotan, N.T., Hong Kong Dear Ambert Fok: Enclosed you will find your file copy of a Part 15 Certification (FCC ID: VWPKENWIN00005) For your reference, TCB will normally take another 10 days for reviewing the report. Approval will then be granted when no query is sorted. Please contact me if you have any questions regarding the enclosed material. Sincerely, Shawn Xing Assistant Manager Enclosure • The test results reported in this test report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample may be said to have been obtained. • This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results referenced from this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. • For Terms And Conditions of the services, it can be provided upon request. • The evaluation data of the report will be kept for 3 years from the date of issuance. TRF No.: FCC 15C_TXa Intertek Testing Services Shenzhen Ltd. Kejiyuan Branch 6F, D Block, Huahan Building, Langshan Road, Nanshan District, Shenzhen, P. R. China Tel: (86 755) 8601 6288 Fax: (86 755) 8601 6751 Website: www.china.intertek-etlsemko.com KENWIN INDUSTRIAL (H.K.) LTD. Application For Certification Soundbar with Wireless Subwoofer (2.4GHz Transceiver) (FCC ID: VWPKENWIN00005) Model: SBW100 Additional Model: KW-SB001; D15; SB150V; KW-SB002 SZ10050384-1 Billy Li August 16, 2010 INTERTEK TESTING SERVICE TRF No.: FCC 15C_TXa FCC ID: VWPKENWIN00005 i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1: Summary of Tests EXHIBIT 2: General Description EXHIBIT 3: System Test Configuration EXHIBIT 4: Measurement Results EXHIBIT 5: Equipment Photographs EXHIBIT 6: Product Labeling EXHIBIT 7: Technical Specifications EXHIBIT 8: Instruction Manual EXHIBIT 9: Confidentiality Request EXHIBIT 10: Miscellaneous Information EXHIBIT 11: Test Equipment List INTERTEK TESTING SERVICES TRF No.: FCC 15C_TXa FCC ID: VWPKENWIN00005 ii MEASUREMENT/TECHNICAL REPORT KENWIN INDUSTRIAL (H.K.) LTD. - MODEL: SBW100 FCC ID: VWPKENWIN00005 This report concerns (check one) Original Grant X Class II Change Equipment Type: DTS - Part 15 Digital Transmission Systems Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? Yes No X If yes, defer until : date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37? Yes No X If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR [10-1-09 Edition] provision. Report prepared by: Shawn Xing Intertek Testing Services Shenzhen Ltd. Kejiyuan Branch 6F, Block D, Huahan Building, Langshan Road, Nanshan District, Shenzhen, P. R. China Phone: (86 755) 8601 6288 Fax: (86 755) 8601 6751 INTERTEK TESTING SERVICES TRF No.: FCC 15C_TXa FCC ID: VWPKENWIN00005 iii Table of Contents 1.0 Summary of test results.............................................................................. 2 2.0 General Description................................................................................................4 2.1 Product Description ....................................................................................... 4 2.2 Related Submittal(s) Grants .......................................................................... 5 2.3 Test Methodology.......................................................................................... 5 2.4 Test Facility ................................................................................................... 5 3.0 System Test Configuration ................................................................................. 7 3.1 Justification ................................................................................................... 7 3.2 EUT Exercising Software............................................................................... 7 3.3 Details of EUT and Description of Peripherals............................................... 7 3.4 Measurement Uncertainty ................................................................................8 3.5 Equipment Modification ................................................................................. 8 4.0 Measurement Results.......................................................................................... 10 4.1 Maximum Conducted Output Power at Antenna Terminals.......................... 10 4.2 Minimum 6dB RF Bandwidth ....................................................................... 11 4.3 Maximum Power Density ................................................................................12 4.4 Out of Band Conducted Emissions ...............................................................13 4.5 Out of Band Radiated Emissions ................................................................. 15 4.6 Transmitter Radiated Emissions in Restricted Bands................................... 1…
Text truncated - open the document above for the full version.
Conducted Photos
Radiated Photos
6F, D Block, Huahan Building, Langshan Road · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 23.40 mW |

Bluetooth Speaker
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Soundbar with Wireless Subwoofer
Equipment Class
DTS - Digital Transmission System
Portable Internet WiFi Radio
Equipment Class
DTS - Digital Transmission System
Internet Radio Micro Hi-Fi System
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral