
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RNX-AC1200UB AC1200 Wireless Dual Band USB Adapter 1910020742 REV1.0.0 FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/ TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. FCC RF Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure co mpliance. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment has been SAR-evaluated for use in hand. SAR measurements are based on a 5mm spacing from the body and that compliance is achieved at that distance. I CE Mark Warning This is a class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. National Restrictions This device is intended for home and office use in all EU countries (a nd other countries following the EU directive 1999/5/EC) without any limitation except for the countries mentioned below: Country Restriction Reason/remark Bulgaria None General authorization required for outdoor use and public service France Outdoor use limited to 10 mW e.i.r.p. with in the band 2454-2483.5 MHz Military Radiolocation use. Refarming of the 2.4 GHz band has been ongoing in recent years to allow current relaxed regulation. Full implementation planned 2012 Italy None If used outside of own premises, general authorization is required Luxembourg None General authorization required for network and service supply(not for spectrum) Norway Implemented This subsection does not apply for the geographical area within a radius of 20 km from the centre of Ny-Ålesund Russian Federation None Only for indoor applications Note: Please don’t use the product outdoors in France. 5150-5250 MHz Country Restriction Reason/remark Bulgaria Not implemented Planned Croatia License required Italy General authorization required if used outside own premises II Luxembourg None General authorization required for network and service supply (not for spectrum) Russian Federation No info 5250-5350 MHz Country Restriction Reason/remark Bulgaria Not implemented Planned Croatia License required Italy General authorization required if used outside own premises Luxembourg None General authorization required for network and service supply (not for spectrum) Russian Federation No info 5470-5725 MHz Country Restriction Reason/remark Bulgaria Not implemented Planned France Relevant+ provisions for the implementation of DFS mechanism described in ETSI standard EN 301 893 V1.3.1 and subsequent versions Italy General authorization required if used outside own premises Luxembourg None General authorization required for network and service supply (not for spectrum) Russian Federation No info Turkey Not implemented Defence systems Note: Please don’t use the product outdoors in France. III CONTENTS Package Contents ........................................................................................................ 1 Chapter 1 Product Overview ..................................................................................... 2 1.1 Introduction ........................................................................................................................ 2 1.2 Features ............................................................................................................................. 2 1.3 Hardware Overview ........................................................................................................... 3 Chapter 2 Installation ................................................................................................. 4 2.1 Hardware Installation ......................................................................................................... 4 2.2 Software Installation ........................................................................................................... 5 Chapter 3 Connect to a Wireless Network.............................................................. 10 3.1 To connect using Rosewill Wireless Configuration Utility ................................................. 10 3.2 To connect using WPS ..................................................................................................... 13 3.3 To connect using Windows built-in wir…
Text truncated - open the document above for the full version.
RosewillInc. DFSclientdevicechannelplanandsoftwareoperationaldeclaration Date:2015-04-22 We,RosewillInc,declarethatthedevice,FCCID:W6RRNX-AC1200UB,ModelName: RNX-AC1200UB,doesnothave“AdHoconnon-USfrequencies”and/or“onDFSfrequencies. Also,theclientsoftwareandassociateddriverswillnotinitiateanytransmissiononDFS frequencieswithoutinitiationbyamaster.Thisincludesrestrictionontransmissionsfor beaconsandsupportforad-hocpeer-to-peermodes. Belowisthechannel/frequencyplanforthedevice Also,onDFSchannels,theWLANdriverinthedeviceoperatesunderthecontrolofanAPatall times,exceptwheninad-hocmode,onUSnon-DFSchannels.ThedevicepassivelyscansDFS frequenciesuntilamasterdeviceisdetected.Thecontrolofthisfunctionalityisnotaccessible toanyoneunderanyconditions.Furthermore,thefirmwareisprotectedbyspecialsignature andCRCchecksum.SignatureandCRCchecksumwillbecalculatedandverifiedbefore firmwareupgrade.Unauthorizedmodificationtofirmwarewillleadthefailureofverification thusfirmwareupgradeisnotallowed. Sincerelyyours, CH1234567891011 Frequency(MHz)24122417242224272432243724422447245224572462 ScanTypeActiveActiveActiveActiveActiveActiveActiveActiveActiveActiveActive CH3638404244485254565860 Frequency(MHz)51805190520052105220524052605270528052905300 ScanType ActiveActiveActiveActiveActiveActivePassivePassivePassivePassivePassive CH6264 Frequency(MHz)53105320 ScanType PassivePassive CH100102104106108110112116132134136 Frequency(MHz)55005510552055305540555055605580566056705680 ScanTypePassivePassivePassivePassivePassivePassivePassivePassivePassivePassivePassive CH140 Frequency(MHz)5700 ScanTypePassive CH149151153155157159161165 Frequency(MHz)57455755576557755785579558055825 ScanTypeActiveActiveActiveActiveActiveActiveActiveActive Nameofauthorizedsigner:WayneChou Titleofauthorizedsigner:ProductManager CompanyName:RosewillInc. Tel:886-2-8752-3555 Fax:886-2-8572-3556 Website:WWW.ROSEWILL.COM
Rosewill Inc. Date: 2015-04-07 FCC ID: W6RRNX-AC1200UB AUTHORIZATION LETTER To whom it may concern: We, the undersigned, hereby authorize Andrea Hsia (Senior Specialist) of Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch (BV CPS Taoyuan) of Taiwan to act on our behalf in all manners relating to FCC application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Andrea Hsia (Senior Specialist) of BV CPS Taoyuan on our behalf shall have the same effect as acts of our own. If you have any questions regarding the authorization, please don’t hesitate to contact us. Sincerely yours, Name of authorized signer: Wayne Chou Title of authorized signer: Product Manager Company Name: Rosewill Inc. Tel: 886-2-8752-3555 Fax: 886-2-8572-3556 Web site: WWW.ROSEWILL.COM
RosewillInc. AttestationforFCCDeclarationof Conformity FCCID:W6RRNX-AC1200UBDate:2015-04-03 Pleasebenotifiedthatwe,theundersigned,RosewillInc.declarethat theproductbearstheaboveFCCIDisalsocomplyingwiththerequirementsof FCCDoC.ThetestreportnumberforFCCDoCisFD130924C01B,withis issuedbyanaccreditedlab,BureauVeritasConsumerProductsServices (H.K.)Ltd.,TaoyuanBranch(BVCPSTaoyuan)ofTaiwan.Whichhasbeen accreditedinaccordancetoalloftherequirementsof47CFR2.948(d)and(e) oftheFCCrulesandKDB349827. Sincerely, Nameofauthorizedsigner:WayneChou Titleofauthorizedsigner:ProductManager CompanyName:RosewillInc. Tel:886-2-8752-3555 Fax:886-2-8572-3556 Website:WWW.ROSEWILL.COM
Rosewill Inc. Date: 2015-04-07 FCC ID: W6RRNX-AC1200UB To the attention of Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below: Schematics Block Diagram Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely yours, Tel: 886-2-8752-3555 Fax: 886-2-8572-3556 Web site: WWW.ROSEWILL.COM Name of authorized signer: Wayne Chou Title of authorized signer: Product Manager Company Name: Rosewill Inc.
Page 1 CONSTRUCTION PHOTOS OF EUT Page 2
Label location
Page 3 Page 4
Report No.: RF130924C01B-2 1 of 29 Report Format Version 5.1.0 Reference No: 130924C01, 150325C19 DFS TEST REPORT REPORT NO.: RF130924C01B-2 MODEL NO.: RNX-AC1200UB FCC ID: W6RRNX-AC1200UB RECEIVED: Sep. 24, 2013 TESTED: Nov. 11, 2013 ISSUED: Mar. 31, 2015 APPLICANT: Rosewill Inc. ADDRESS: 17708 Rowland Street, City of Industry, CA 91748, USA ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City 33383, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the com pliance or non-compliance to the specification. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: RF130924C01B-2 2 of 29 Report Format Version 5.1.0 Reference No: 130924C01, 150325C19 TABLE OF CONTENTS RELEASE CONTROL RECORD ........................................................................................................ 3 1. CERTIFICATION ...................................................................................................................... 4 2. EUT INFORMATION ................................................................................................................ 5 2.1 OPERATING FREQUENCY BANDS AND MODE OF EUT ..................................................... 5 2.2 EUT SOFTWARE AND FIRMWARE VERSION ....................................................................... 5 2.3 DESCRIPTION OF AVAILABLE ANTENNAS TO THE EUT .................................................... 5 2.4 EUT MAXIMUM CONDUCTED POWER ................................................................................. 6 2.5 EUT MAXIMUM E.I.R.P. POWER ............................................................................................ 7 2.6 TRANSMIT POWER CONTROL (TPC) ................................................................................... 8 2.7 STATEMENT OF MAUNFACTURER ....................................................................................... 8 3. U-NII DFS RULE REQUIREMENTS ........................................................................................ 9 3.1 WORKING MODES AND REQUIRED TEST ITEMS ............................................................... 9 3.2 TEST LIMITS AND RADAR SIGNAL PARAMETERS ............................................................ 10 4. TEST & SUPPORT EQUIPMENT LIST ................................................................................. 12 4.1 TEST INSTRUMENTS ........................................................................................................... 12 4.2 DESCRIPTION OF SUPPORT UNITS .................................................................................. 12 5. TEST PROCEDURE .............................................................................................................. 13 5.1 BV ADT DFS MEASUREMENT SYSTEM ............................................................................. 13 5.2 CALIBRATION OF DFS DETECTION THRESHOLD LEVEL: ............................................... 14 5.3 DEVIATION FROM TEST STANDARD .................................................................................. 14 5.4 RADIATED TEST SETUP CONFIGURATION ....................................................................... 15 5.4.1 CLIENT WITHOUT RADAR DETECTION MODE ................................................................. 15 6. TEST RESULTS ..................................................................................................................... 16 6.1 SUMMARY OF TEST RESULTS............................................................................................ 16 6.2 TEST RESULTS ..................................................................................................................... 17 6.2.1 TEST MODE: DEVICE OPERATING IN CLIENT WITHOUT RADAR DETECTION MODE. 17 6.2.2 CHANNEL CLOSING TRANSMISSION AND CHANNEL MOVE TIME ................................. 19 6.2.3 NON-OCCUPANCY PERIOD ................................................................................................. 25 6.2.4 NON-ASSOCIATED TEST ..................................................................................................... 27 6.2.5 NON- CO-CHANNEL TEST ................................................................................................... 27 7. INFORMATION ON THE TESTING LABORATORIES .......................................................... 28 8. APPENDIX A - MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT BY THE LAB ........................................................................................................…
Text truncated - open the document above for the full version.
FCC SAR Test Report Report Format Version 5.0.0 Issued Date : Apr. 09, 2015 Report No. : SA130924C01B Reference No.: 150325C19 Appendix D. Photographs of EUT and Setup FCC SAR Test Report Report Format Version 5.0.0 Report No. : SA130924C01B Reference No.: 150325C19 <Photographs of EUT> <Antenna Location> Ant-0 Ant-1 FCC SAR Test Report Report Format Version 5.0.0 Report No. : SA130924C01B Reference No.: 150325C19 <Photographs of SAR Setup> USB Horizontal Up with 0.5 cm Gap USB Horizontal Down with 0.5 cm Gap USB Vertical Front with 0.5 cm Gap USB Vertical Back with 0.5 cm Gap Tip Mode with 0.5 cm Gap
No.19, Hwa Ya 2nd Rd.,Wen Hwa Vil.,Kwei Shan Dist · Taoyuan City · Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 3 | 15E | 5.50 GHz - 5.70 GHz | 78.00 mW |

Bluetooth Earphones
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Headphone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
300Mbps Wireless N USB Adapter
Equipment Class
DTS - Digital Transmission System
150Mbps Wireless N Nano USB Adapter
Equipment Class
DTS - Digital Transmission System
N600 Wireless Dual Band PCI Express Adapter
Equipment Class
NII - Unlicensed National Information Infrastructure TX