Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Mar 24, 2015
Application Purpose
Original Equipment
Date of Application
Mar 24, 2015
Equipment Note
Mobile POS
Frequency Range
13.56000000 - 13.56000000
Company
CASTLES TECHNOLOGY CO., LTD.
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

MP200 Mobile POS Book 2 User Manual Confidential Version 2.1 Feb 2015 CASTLES TECHNOLOGY Castles Technology Co., Ltd. 2F, No. 205, Sec. 3, Beixin Rd., XindianDistrict, New Taipei City 23143, Taiwan R.O.C. http://www.castech.com.tw Castles Technology Co., Ltd. Confidential • All Right Reserved. Pg. 2 WARNING Information in this document is subject to change without prior notice. No part of this publication may be reproduced, transmitted, stored in a retrieval system, nor translated into any human or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior written permission of Castles Technology Co., Ltd. All trademarks mentioned are proprietary of their respective owners. Castles Technology Co., Ltd. Confidential • All Right Reserved. Pg. 3 Revision History Version Date Descriptions 1.0 Sep 10, 2014 Initial creation. 2.0 Dec 19, 2014 1. Add “Key Injection” on “System Menu” page 2. UI arrangement on “SYSTEM INFO” page 3. Add “BT DIRECT ACCESS”, “Halt Timeout”, “PWM Auto”, “PWM Mode”, “PWM Time” on “SYS SETTINGS” page 4. UI arrangement on “Test Utility” page 2.1 Feb 12, 2015 1. Add the description of Environment. 2. Add the description of Power. 3. Add the UL caution of battery. Castles Technology Co., Ltd. Confidential • All Right Reserved. Pg. 4 Contents 1. Introduction .................................................................................................................. 6 2. Hardware Setup ............................................................................................................ 7 2.1. Parts of the Surface ............................................................................................. 7 2.2. Environment ........................................................................................................ 9 2.3. Power .................................................................................................................. 9 3. Basic Operation ......................................................................................................... 10 3.1. Program Manager .............................................................................................. 10 3.2. Download AP ..................................................................................................... 12 3.3. System Info........................................................................................................ 13 3.4. Memory Status .................................................................................................. 14 3.5. System Settings ................................................................................................. 15 3.6. Test Utility .......................................................................................................... 18 3.7. Factory Reset .................................................................................................... 20 3.8. Power Off .......................................................................................................... 21 3.9. Function Key Password Change ........................................................................ 22 3.10. Share Object Management ................................................................................ 23 3.11. Castles TMS ...................................................................................................... 24 3.12. Font Mng ........................................................................................................... 25 3.13. Debug Tools ...................................................................................................... 26 3.14. ULD Key Hash ................................................................................................... 27 3.15. Plug-in Mng ....................................................................................................... 28 3.16. Key Injection ...................................................................................................... 29 4. Secure File Loading ................................................................................................... 30 4.1. ULD Key System ............................................................................................... 30 4.1.1. ULD Manufacturer Key ........................................................................... 30 4.1.2. ULD User Key ........................................................................................ 32 4.1.3. Key Change ........................................................................................... 32 4.2. File Signing ........................................................................................................ 33 4.2.1. Signing Kernel Module ........................................................................... 33 4.2.2. Signing User Files .................................................................................. 35 4.3. File Loading ....................................................................................................... 39 4.3.1. Download by User Loader ...................................................................... 39 4.4. Changing ULD User Key.................................................................................... 42 Castles Technology Co., Ltd. Confidential • All Right Reserved. Pg. 5 5. Font Management ...................................................................................................... 49 5.1. Loading New Font.............................................................................................. 49 5.2. Custom Font ...................................................................................................... 52 5.3. Using TrueType Font (TTF) ............................................................................... 60 6. FCC Warning .........................................................................................…

Text truncated - open the document above for the full version.

Attestation Statements

Date: 2015/3/12 Subject: DoC declaration To Whom it may concern, We, as the grantee of this project FCC ID: , would like to declare that the composite portion categorized as computer peripheral has been authorized under the Declaration of Conformity procedures. Regards, Signature Name/Title: Eddie Lin / Vice President of R & Division Company Name: Address: TEL: +886- FAX: +886- Email: [email protected]

Cover Letter(s)

Example of Agents letter (for TCB – TCB approval): Date: 2015-03-12 BABT TCB Forsyth House, Churchfield Road, Walton-on-Thames, Surrey, KT12 2TD Dear Sir or Madam, We, , hereby authorize Compliance Certification Services Inc / David.Wang. to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. This authorization expires on 3/12/2016 Sincerely, Signature Name/Title: Eddie Lin / Vice President of R & Division Company Name: Address: TEL: +886- FAX: +886 - Email: [email protected]

Cover Letter(s)

Date : 2015-03-12 BABT TCB Forsyth House, Churchfield Road, Walton-on-Thames, Surrey, KT12 2TD Confidentiality Request FCC ID: WIYMP200 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, hereby requests permanent confidential treatment of information accompanying this application as outlined below: Schematics Block Theory of Operation Tune up Procedure The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Signature Name/Title: Eddie Lin / Vice President of R & Division Company Name: Address: TEL: +886- FAX: +886- Email: [email protected]

External Photos

Compliance Certification Services Inc. Report No.: T150107W14 Date of Issue: March 6, 2015 A1 - 1 / 9 Rev. 00 APPENDIX 1 - PHOTOGRAPHS OF EUT EXTERNAL PHOTOGRAPHS OF EUT Compliance Certification Services Inc. Report No.: T150107W14 Date of Issue: March 6, 2015 A1 - 2 Rev. 00 Compliance Certification Services Inc. Report No.: T150107W14 Date of Issue: March 6, 2015 A1 - 3 Rev. 00

Internal Photos

Compliance Certification Services Inc. Report No.: T150107W14 Date of Issue: March 6, 2015 A1 - 4 Rev. 00 INTERNAL PHOTOGRAPHS OF EUT Compliance Certification Services Inc. Report No.: T150107W14 Date of Issue: March 6, 2015 A1 - 5 Rev. 00 WIFI Module Compliance Certification Services Inc. Report No.: T150107W14 Date of Issue: March 6, 2015 A1 - 6 Rev. 00 Bluetooth Module Compliance Certification Services Inc. Report No.: T150107W14 Date of Issue: March 6, 2015 A1 - 7 Rev. 00 Chip Antenna Compliance Certification Services Inc. Report No.: T150107W14 Date of Issue: March 6, 2015 A1 - 8 Rev. 00 NFC Antenna & NFC Tag Compliance Certification Services Inc. Report No.: T150107W14 Date of Issue: March 6, 2015 A1 - 9 Rev. 00 Battery

Test Report

Compliance Certification Services Inc. FCC ID: WIYMP200 Report No.: T150107W14-RP4 Note: This report shall not be reproduced except in full, without the written approval of Compliance Certification Services Inc. This document may be altered or revised by Compliance Certification Services Inc. personnel only, and shall be noted in the revision section of the document. Page 1 / 29 FCC 47 CFR PART 15 SUBPART C TEST REPORT For Mobile POS Model: MP200 Trade Name: CASTLES TECHNOLOGY Issued to CASTLE TECHNOLOGY CO.,LTD 2F., No.205, Sec. 3, Beixin Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Issued by Compliance Certification Services Inc. No.11, Wugong 6th Rd., Wugu Dist., New Taipei City 24891, Taiwan. (R.O.C.) http://www.ccsrf.com [email protected] Issued Date: January 21, 2015 Compliance Certification Services Inc. FCC ID: WIYMP200 Report No.: T150107W14-RP4 Page 2 Revision History Rev. Issue Date Revisions Effect Page Revised By 00 January 21, 2015 Initial Issue ALL Becca Chen Compliance Certification Services Inc. FCC ID: WIYMP200 Report No.: T150107W14-RP4 Page 3 TABLE OF CONTENTS 1. TEST RESULT CERTIFICATION ............................................................................................. 4 2. EUT DESCRIPTION .................................................................................................................... 5 3. TEST METHODOLOGY ............................................................................................................. 6 3.1 EUT CONFIGURATION ...................................................................................................... 6 3.2 EUT EXERCISE .................................................................................................................... 6 3.3 GENERAL TEST PROCEDURES ........................................................................................ 6 3.4 FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS .......................................... 7 3.5 DESCRIPTION OF TEST MODES ...................................................................................... 7 4. INSTRUMENT CALIBRATION ................................................................................................. 8 4.1 MEASURING INSTRUMENT CALIBRATION.................................................................. 8 4.2 MEASUREMENT EQUIPMENT USED .............................................................................. 8 4.3 MEASUREMENT UNCERTAINTY .................................................................................... 9 5. FACILITIES AND ACCREDITATIONS ................................................................................. 10 5.1 FACILITIES ......................................................................................................................... 10 5.2 EQUIPMENT ....................................................................................................................... 10 5.3 TABLE OF ACCREDITATIONS AND LISTINGS ........................................................... 11 6. SETUP OF EQUIPMENT UNDER TEST ................................................................................ 12 6.1 SETUP CONFIGURATION OF EUT ................................................................................. 12 6.2 SUPPORT EQUIPMENT .................................................................................................... 12 7. FCC PART 15.225 REQUIREMENTS ...................................................................................... 13 7.1 20 DB BANDWIDTH .......................................................................................................... 13 7.2 RADIATED EMISSIONS ................................................................................................... 15 7.3 FREQUENCY STABILITY ................................................................................................ 21 7.4 POWERLINE CONDUCTED EMISSIONS ....................................................................... 23 APPENDIX I PHOTOGRAPHS OF TEST SETUP ....................................................................... 26 APPENDIX 1 - PHOTOGRAPHS OF EUT Compliance Certification Services Inc. FCC ID: WIYMP200 Report No.: T150107W14-RP4 Page 4 1. TEST RESULT CERTIFICATION Applicant: CASTLE TECHNOLOGY CO.,LTD 2F., No.205, Sec. 3, Beixin Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Equipment Under Test: Mobile POS Trade Name: CASTLES TECHNOLOGY Model: MP200 Date of Test: January 14 ~ 17, 2015 APPLICABLE STANDARDS STANDARD TEST RESULT FCC 47 CFR Part 15 Subpart C No non-compliance noted We hereby certify that: The above equipment was tested by Compliance Certification Services Inc. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4: 2009 and the energy emitted by the sample tested as described in this report is in compliance with the requirements of FCC Rules Part 15.225. The test results of this report relate only to the tested sample identified in this report. Approved by: Reviewed by: Miller Lee Angel Cheng Section Manager Section Manager Compliance Certification Services Inc. Compliance Certification Services Inc. Compliance Certification Services Inc. FCC ID: WIYMP200 Report No.: T150107W14-RP4 Page 5 2. EUT DESCRIPTION Product Mobile POS Trade Name CASTLES TECHNOLOGY Model Number MP200 Model Difference N/A Received Date January 7, 2015 Power Ratting 1. Power form Li-ion BATTERY Rating: 3.7V, 1150mAh 2. Power from host device via USB Cable Frequency Range 13.56MHz Modulation Technique ASK Number of Channels 1 Channel Antenna Specification Castles Technology / MP200 Contactless Antenna Loop Antenna / Gain: 0dBi Remark: 1. The sample selected for test was engineering sample that approximated to production product and was provided by manufacturer. 2. This submittal(s) (test report) is intended for FCC ID: WIYMP200 filing to com…

Text truncated - open the document above for the full version.

Test Setup Photos

Compliance Certification Services Inc. FCC ID: WIYMP200 Report No.: T150107W14-RP4 Page 26 APPENDIX I PHOTOGRAPHS OF TEST SETUP Conducted Emission Set Up Photo Compliance Certification Services Inc. FCC ID: WIYMP200 Report No.: T150107W14-RP4 Page 27 Radiated Emission Set up Photos 9KHz ~ 30MHz Compliance Certification Services Inc. FCC ID: WIYMP200 Report No.: T150107W14-RP4 Page 28 30MHz ~ 1GHz Compliance Certification Services Inc. FCC ID: WIYMP200 Report No.: T150107W14-RP4 Page 29 Powerline Conducted Emissions Setup Photos

Contact Information

Applicant

Evelyn Chen(Project Manager of Product Certification Team)
[email protected]+886-2-8913-1771Fax: 886-2-8913-1772

Test Firm

Compliance Certification Services Inc.Hank Lee
[email protected]886-2-22999720Fax: 886-2-22999721

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term
Grant Notes
This device and its antenna(s) must not be co-located or operated in conjunction with any antenna or transmitter not described under this FCC ID, except in accordance with FCC multi-transmitter RF exposure procedures.

Other Applications from CASTLES TECHNOLOGY CO., LTD.

POS Cradle - FCC ID WIYS1F4BBT001 - CASTLES TECHNOLOGY CO., LTD.
WIYS1F4BBT001

POS Cradle

Apr 02, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
POS Terminal - FCC ID WIYV1P35001 - CASTLES TECHNOLOGY CO., LTD.
WIYV1P35001

POS Terminal

Feb 04, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
WIYS1E4PRO001

POS Terminal

Nov 20, 2025

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
POS Terminal - FCC ID WIYS1MINI2001 - CASTLES TECHNOLOGY CO., LTD.
WIYS1MINI2001

POS Terminal

May 19, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
POS Terminal - FCC ID WIYS1P2001 - CASTLES TECHNOLOGY CO., LTD.
WIYS1P2001

POS Terminal

Jul 28, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter