FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. FALTEC CO.,LTD./
  3. WKE-PZ113-04021

WKE-PZ113-04021Remote Transmitter

FALTEC CO.,LTD.

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jul 07, 2010
Application Purpose
Original Equipment
Date of Application
Jul 07, 2010
Equipment Note
Remote Transmitter
Frequency Range
426.05000000 - 426.05000000
Company
FALTEC CO.,LTD.
Country
Japan

Documents & Files

Select a file to view

Users Manual

โ†—

Attestation Statements

โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

Test Report

โ†—
โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

- 1 - Remote Control Engine Starter System Ownerโ€™s Manual Congratulations on your purchase of the MITSUBISHI MOTORS Remote Control Engine Starter System. This system will provide you with convenience and assistance, making each drive a delightful experience. To take full advantage of your MITSUBISHI MOTORS Remote Control Engine Starter System please read this manual thoroughly. Keep this manual handy for easy reference. Please leave this manual in the car equipped with this remote control engine starter system at the time of resale. Mitsubishi Motors Remote Control Engine Starter System is only for vehicles equipped with an automatic transmission or continuously variable transmission (CVT). Do NOT install Mitsubishi Motors Remote Control Engine Starter System on vehicles with a manual transmission. Ask an authorized Mitsubishi Motors dealer for detail. 10, 6 Introduction 1. Introduction 2 2. Features of the System 3 3. Safety Precaution 4 4. Name of each part 6 5. Display 7 6. Operating the Transmitter 8 7. Before Leaving Your Car 12 8. Care and handling 13 9. Replacement of the transmitter batteries 14 10. Troubleshooting 16 11. Specifications 18 - 2 - Safety message General information Introduction Throughout this manual the words WARNING and CAUTION appear. These are reminders to be especially careful. Failure to follow the instructions could result in personal injury or damage to your vehicle. Indicates a strong possibility of severe personal injury or death if instructions are not followed. Points out hazards or unsafe practices that could cause minor personal injury or damage to your vehicle. You will see another important symbol; NOTE Gives helpful information. - Laws in some communities may restrict the use of remote starters. For example, some laws may require a person using the remote start to have the vehicle in view when doing so. Check local regulations for any requirements on remote starting of vehicles. - This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. - Consult your authorized Mitsubishi Motors dealer for installation of the remote control engine starter system. -FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the userโ€™s authority to operate the equipment. - Do not leave the key where it may be exposed to high temperature or high humidity. - Do not drop the transmitter. - 3 - Features of the System (1) Starting/Stopping the engine - The remote control engine starter system allows you to start or stop the engine by operating the transmitter from outside of the vehicle without using the vehicle key. - However, the transmitter will not start the engine unless all of the following conditions are satisfied; The selector lever is in the โ€œPโ€ (Parking) position. All doors (including the rear gate and spare tire carrier, depending on model) are securely closed. The engine hood is securely closed. The vehicle key is removed from the ignition switch. For vehicle equipped with the Free-hand Advanced Security transmitter (F. A. S. T. โ€“key), the ignition switch is in the Lock position. - The transmitter can stop engine, only when the engine has been started by operating the transmitter. - If the engine does not start on the first try, the system will automatically try to start the engine again. After the third try, the system will halt. - The system will not start the engine when the temperature is very low or the battery voltage is below a certain level. - When the ignition key or switch has not been turned to the ACC, ON or Start position for two weeks or more, the system will deactivate to save the battery. To reactivate the system, turn the ignition switch to the ACC position and then to the Lock position and, if the vehicle is not equipped with the F. A. S. T. โ€“key, remove the key. Wait for three seconds. The system will be reactivated. - Use only one transmitter for the vehicle. Do not register an additional transmitter. (2) Once the engine is started - After starting the engine with the transmitter, the engine will stop if any of following things is done. A door (including the rear gate and spare tire carrier, depending on model) is opened. The gas pedal is applied. The engine hood is opened. The key is inserted into the ignition switch or the ignition switch is turned from the Lock position for a vehicle equipped with F. A. S. T. โ€“key. - The engine will automatically stop 10 or 30 minutes (the time is set through userโ€™s operation of the Remote transmitter in advance) after the engine has been started. Refer to page 10. - 4 - Safety Precaution - Never start the engine by using the remote control engine starter system in a closed or poorly ventilated area. Carbon monoxide gas, which is odorless and extremely poisonous, could build up and cause serious injury or death. - Do not operate the transmitter for the remote control engine starter system unless you can see your vehicle. - To prevent accidental engine start, do not touch the transmitter unnecessarily. The transmitter signal may start the engine even from the area where you cannot see the car. - Do not attempt to operate the transmitter when the engine hood is open. - Do not park your vehicle in areas where combustible materials such as dry grass or leaves can come in contact with a hot exhaust, since a fire could occur. - Do not use the remote engine starting system, when your car is parked on a steep slope. - To avoid an accident, a child or pet should never be unattended in, or unsupervised around your vehicle, when the engine is remotely started. - 5 - - Do not start the engine without removing the body cover from the car. It can cause fire. - When parking the vehicle, make sure that the wiper switch and all exterior light switches areโ€ฆ

Text truncated - open the document above for the full version.

External Photos

ATHD-02-10-0003 Engine remote controller Mobile unit Specification 6 Annexation Inside Package Front Back Top Bottom Right Left

ID Label/Location Info

Label Drawing & Label Location Transmitter Without Cover Transmitter With Cover KDB Tracking Number 923751The label can never be placed on a removable cover. If its a hand held device you may be able to place in on a perm anent location inside if you meet all of the requirements of ou r labeling quidelines regarding this type of placement. SEE http://fjallfoss.fcc.gov/oetcf/kdb/forms/FTSSearchResultPa ge.cfm?id=27980&switch=P and http://fjallfoss.fcc.gov/kdb/GetAt tachment.html?id=26762 The important section is shown below: As an option to placing the FCC label on the exterior of the device, the FCC label may be placed in a user accessible area if the following conditions are met: ใƒปThe device is handheld (notebook computers are considered as h andheld); ใƒปThe FCC identifier is visible at the time of purchase. Marketi ng the device without the battery installed when the label is i n the battery compartment is acceptable. The FCC ID on the box, or additional documentation directing t he user where to find the FCC label, also satisfies this requir ement; ใƒปThe user accessible area must not require any special tools fo r access, and the FCC label must not be placed on a removable p art; ใƒปThe FCC ID, Model Number, or FCC logo must be on the label and must meet all

Internal Photos

ATHD-02-10-0003 Engine remote controller Mobile unit Specification 6 Annexation Inside Package Front Back Top Bottom Right Left

Test Report

Test report No. : 30IE0281-HO-01-R1 Page : 2 of 16 Issued date : June 17, 2010 Revised date : June 30, 2010 FCC ID : WKE-PZ113-04021 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 CONTENTS PAGE SECTION 1: Customer informationยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 SECTION 2: Equipment under test (E.U.T.) ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 SECTION 3: Test specification, procedures & results ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4 SECTION 4: Operation of E.U.T. during testingยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 7 SECTION 5: Radiated emission (Electric Field Strength of Fundamental and Spurious Emission)ยท 8 SECTION 6: Automatically deactivate ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 SECTION 7: -20dB Bandwidth ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 APPENDIX 1: Photographs of test setup ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 10 Radiated emission .............................................................................................................................10 Worst case position ...........................................................................................................................11 APPENDIX 2: Data of EMI test ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 12 Automatically deactivate...................................................................................................................12 Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission) .....................13 -20dB Bandwidth ..............................................................................................................................14 Duty Cycle ........................................................................................................................................15 APPENDIX 3: Test Instruments ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 16 Test report No. : 30IE0281-HO-01-R1 Page : 3 of 16 Issued date : June 17, 2010 Revised date : June 30, 2010 FCC ID : WKE-PZ113-04021 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 SECTION 1: Customer information Company Name : MITSUBISHI CABLE INDUSTRIES, LTD. Address : 1-23-9, Imaike-Cho, Anjo-City, Aichi-pref. 446-0071, Japan Telephone Number : +81-556-97-3222 Facsimile Number : +81-556-97-3251 Contact Person : Hiroshi Kurumagawa <Remarks> MITSUBISHI CABLE INDUSTRIES, LTD. designates NEC Access Technica, Ltd. as manufacturer of the product (Remote Transmitter). SECTION 2: Equipment under test (E.U.T.) 2.1 Identification of E.U.T. Type of Equipment : Remote Transmitter Model No. : PZ113-04021 Serial No. : Refer to Clause 4.2 Rating : DC6.0V (CR 2032 x 2) Receipt Date of Sample : June 10, 2010 Country of Mass-production : Japan Condition of EUT : Production prototype (Not for Sale: This sample is equivalent to mass-produced items.) Modification of EUT : No Modification by the test lab 2.2 Product Description Model: PZ113-04021 (referred to as the EUT in this report) is a Remote Transmitter (Remote Engine Starter) which commands remotely from the outside of vehicles. This device is a Specified low-power radio equipment for telecontrol, which has a function of transmitting the command (Start and Stop of Engine, etc.) from the transmitter body. General Specification Clock frequency(ies) in the system : CPU: 4.915MHz, RF-IC: 14.7456MHz Radio Specification Radio Type : Transmitter Frequency of Operation : 426.050MHz Intermediate Frequency : 307.2 kHz Modulation : GFSK Antenna type : Chip Antenna Test report No. : 30IE0281-HO-01-R1 Page : 4 of 16 Issued date : June 17, 2010 Revised date : June 30, 2010 FCC ID : WKE-PZ113-04021 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 SECTION 3: Test specification, procedures & results 3.1 Test Specification Test Specification : FCC Part15 Subpart C: 2010, final revised on January 22, 2010 and effective March 1, 2010 Title : FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators Section 15.231 Periodic operation in the band 40.66 - 40.70MHz and above 70MHz 3.2 Procedures and results Item Test Procedure Specification Worst margin Results Remarks Conducted emission ANSI C63.4:2003 7. AC powerline conducted emission measurements Section 15.207 N/A N/A*1) - Automatically Deactivate ANSI C63.4:2003 13. Measurement of intentional radiators Section 15.231(a)(1) N/A Complied Radiated Electric Field Strength of Fundamental Emission ANSI C63.4:2003 13. Measurement of intentional radiators Section 15.231(b) 5.7dB 426.050MHz Horizontal, QP Complied Radiated Electric Field Strength of Spurious Emission ANSI C63.4:2003 13. Measurement of intentional radiators Section 15.205 Section 15.209 Section 15.231(b) 10.3dB 1704.200MHz Vertical, PK with Duty factor Complied Radiated -20dB Bandwidth ANSI C63.4:2003 13. Measurement of intentional radiators Section 15.231(c) N/A Complied Radiated Note: UL Japan, Inc.โ€™s EMI Work Procedures No.QPM05 and QPM15. *1) The test is not applicable since the EUT does not have AC Mains. FCC 15.31 (e) This test was performed with the New Battery (DC 6.0V: DC3.0 x 2) and the constant voltage was supplied to the EUT during the tests. Therefore, the EUT complies with the requirement. FCC Part 15.203 Antenna requโ€ฆ

Text truncated - open the document above for the full version.

Test Report

Test report No. : 30IE0281-HO-01-R1 Page : 12 of 16 Issued date : June 17, 2010 Revised date : June 30, 2010 FCC ID : WKE-PZ113-04021 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 APPENDIX 2: Data of EMI test Automatically deactivate Test place Head Office EMC Lab. No.4 Semi Anechoic Chamber Report No. 30IE0281-HO-01 Date 06/10/2010 Temperature/ Humidity 23 deg.C./ 60% Engineer Keisuke Kawamura Mode Normal use mode Time of Transmitting [sec] Limit [sec] Result 3.208 5.00 Pass Test report No. : 30IE0281-HO-01-R1 Page : 13 of 16 Issued date : June 17, 2010 Revised date : June 30, 2010 FCC ID : WKE-PZ113-04021 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission) Test place Head Office EMC Lab. No.4 Semi Anechoic Chamber Report No. 30IE0281-HO-01 Date 06/10/2010 Temperature/ Humidity 23 deg.C./ 60% Engineer Keisuke Kawamura Mode Transmitting mode QP or PK Frequenc yDetectorAntLossGainDutyLimitRemark FactorFactorInside or Outside [MHz]HorVer[dB/m][dB][dB][dB]HorVer[dBuV/m ]HorVerof Restricted Bands 426.050 QP78.277.418.010.531.9-74.874.080.55.76.5 Carrier 852.100 QP25.125.123.412.731.5-29.729.760.530.830.8 Outside 1278.150 PK43.645.124.62.333.9-36.638.180.543.942.4 Outside 1704.200 PK45.948.425.62.532.9-41.143.673.932.830.3 Inside 2130.250 PK42.543.126.22.832.3-39.239.880.541.340.7 Outside 2556.300 PK42.242.327.03.032.1-40.140.280.540.440.3 Outside 2982.350 PK42.441.528.03.231.9-41.740.880.538.839.7 Outside 3408.400 PK45.044.529.03.431.7-45.745.280.534.835.3 Outside 3834.450 PK41.941.429.23.631.6-43.142.673.930.831.3 Inside 4260.500 PK41.341.229.53.731.5-43.042.973.930.931.0 Inside Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter) - Gain(Amplifier) PK with Duty factor Frequenc yDetectorAntLossGainDutyLimitRemark FactorFactorInside or Outside [MHz]HorVer[dB/m][dB][dB][dB]HorVer[dBuV/m ]HorVerof Restricted Bands 1278.150 PK43.645.124.62.333.90.036.638.160.523.922.4 Outside 1704.200 PK 45.948.425.62.532.90.041.143.653.912.810.3 Inside 2130.250 PK 42.543.126.22.832.30.039.239.860.521.320.7 Outside 2556.300 PK 42.242.327.03.032.10.040.140.260.520.420.3 Outside 2982.350 PK 42.441.528.03.231.90.041.740.860.518.819.7 Outside 3408.400 PK 45.044.529.03.431.70.045.745.260.514.815.3 Outside 3834.450 PK 41.941.429.23.631.60.043.142.653.910.811.3 Inside 4260.500 PK41.341.229.53.731.50.043.042.953.910.911.0 Inside Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter) - Gain(Amplifier) + Duty factor (Refer to Duty factor data sheet) *Other frequency noises omitted in this report were not seen or had enough margin (more than 20dB). Margin [dB] Margin [dB] ReadingResult Reading [dBuV] Result [dBuV/m] [dBuV][dBuV/m] * The test above 1GHz was performed with PK detect. Average emission measurements were not calculated with PK detect and Duty cycle factor since the PK measurement value did not exceed the AV limit. Test report No. : 30IE0281-HO-01-R1 Page : 14 of 16 Issued date : June 17, 2010 Revised date : June 30, 2010 FCC ID : WKE-PZ113-04021 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 -20dB Bandwidth Test place Head Office EMC Lab. No.4 Semi Anechoic Chamber Report No. 30IE0281-HO-01 Date 06/10/2010 Temperature/ Humidity 23 deg.C./ 60% Engineer Keisuke Kawamura Mode Normal use mode Bandwidth Limit : Fundamental Frequency 426.05 MHz x 0.25% = 1065.13 kHz -20dB BandwidthResult [kHz] 33.60Pass Bandwidth Limit [kHz] 1065.13 Test report No. : 30IE0281-HO-01-R1 Page : 15 of 16 Issued date : June 17, 2010 Revised date : June 30, 2010 FCC ID : WKE-PZ113-04021 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Duty Cycle Test place Head Office EMC Lab. No.4 Semi Anechoic Chamber Report No. 30IE0281-HO-01 Date 06/10/2010 Temperature/ Humidity 23 deg.C./ 60% Engineer Keisuke Kawamura Mode Normal use mode ON timeCycleDutyDuty [ms][ms](On time/Cycle)[dB] 100.00100.001.000.0 *3)ON time = Type A's ON time (in 100ms) + Type B's ON time (in 100ms) *4)Duty = 20log10(ON time/Cycle) 100ms Test report No. : 30IE0281-HO-01-R1 Page : 16 of 16 Issued date : June 17, 2010 Revised date : June 30, 2010 FCC ID : WKE-PZ113-04021 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 APPENDIX 3: Test Instruments EMI test equipment Control No. Instrument Manufacturer Model No Serial No Test Item Calibration Date * Interval(month) MAEC-04 Semi Anechoic Chamber(NSA) TDK Semi Anechoic Chamber 3m DA-10005 RE 2010/02/02 * 12 MOS-15 Thermo-Hygrometer Custom CTH-180 - RE 2010/02/09 * 12 MJM-08 Measure PROMART SEN1955 - RE - COTS-MEMI EMI measurement program TSJ TEPTO-DV - RE - MSA-04 Spectrum Analyzer Agilent E4448A US44300523 RE 2009/08/25 * 12 MTR-07 Test Receiver Rohde & Schwarz ESCI 100635 RE 2009/10/23 * 12 MBA-05 Biconical Antenna Schwarzbeck BBA9106 1302 RE 2010/03/22 * 12 MLA-08 Logperiodic Antenna Schwarzbeck UKLP9140-A N/A RE 2010/01/23 * 12 MCC-50 Coaxial cable UL Japan - - RE 2010/03/18 * 12 MAT-51 Attenuator(6dB) Weinschel 2 AS3557 RE 2010/01/20 * 12 MPA-14 Pre Amplifier SONOMA INSTRUMENT 310 260833 RE 2010/03/05 * 12 MHA-21 Horn Antenna 1- 18GHz Schwarzbeck BBHA9120D 9120D-557 RE 2009/08/10 * 12 MCC-57 Microwave Cable Suhner SUCOFLEX104 246769(1m) / 292411(5m) RE 2009/11/17 * 12 MPA-12 MicroWave System Amplifier Agilent 83017A MY39500780 RE 2010/03/16 * 12 The expiration date of the calibration is the end of the expired month. All equipment is calibrated with traceable calibrations. Each calibration is traceable to the national or international standards. As for some calโ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

Test report No. : 30IE0281-HO-01-R1 Page : 10 of 16 Issued date : June 17, 2010 Revised date : June 30, 2010 FCC ID : WKE-PZ113-04021 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 APPENDIX 1: Photographs of test setup Radiated emission Photo 1 Photo 2 Test report No. : 30IE0281-HO-01-R1 Page : 11 of 16 Issued date : June 17, 2010 Revised date : June 30, 2010 FCC ID : WKE-PZ113-04021 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Worst case position (Horizontal: X-axis/Vertical : Y-axis) X-axis Y-axis Z-axis

Contact Information

Applicant

Hiroshi Kurumagawa(Manager)
[email protected]81-44-520-0019Fax: 81-44-520-0018

Technical Contact

UL Japan, Inc.Takahiro Hatakeda
[email protected]+81-596-24-8116

4383-326 Asama-cho, ยท Ise-shi, Mie-ken ยท Japan

Test Firm

UL Japan, Inc. Head office EMC Lab.Tetsuya Hashimoto
[email protected]+81-596-24-8116Fax: +81-596-24-8095

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231426.05 MHz - 426.05 MHz-
Confidentiality
Long Term

Other Applications from FALTEC CO.,LTD.

Remote Starter Unit - FCC ID WKE-PZ170-04021 - FALTEC CO.,LTD.
WKE-PZ170-04021

Remote Starter Unit

Oct 20, 2011

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Transmitter - FCC ID WKE-PZ170-02021 - FALTEC CO.,LTD.
WKE-PZ170-02021

Remote Transmitter

Oct 19, 2011

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Controller - FCC ID WKE-PZ113-04041 - FALTEC CO.,LTD.
WKE-PZ113-04041

Remote Controller

Jul 07, 2010

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter