FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. GN Hearing A/S/
  3. X26SY312

X26SY312Hearing instruments with wireless communication capabilities

GN Hearing A/S
Hearing instruments with wireless communication capabilities - FCC ID X26SY312 - GN Hearing A/S
Click to zoom

Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Apr 14, 2010
Application Purpose
Original Equipment
Date of Application
Apr 14, 2010
Equipment Note
Hearing instruments with wireless communication capabilities
Frequency Range
2404.00000000 - 2478.00000000
Company
GN Hearing A/S
Country
Denmark

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

USER GUIDE RECEIVER-IN-EAR HEARING INSTRUMENT 2 3 radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: t3FPSJFOUPSSFMPDBUFUIFSFDFJWJOHBOUFOOB t*ODSFBTFUIFTFQBSBUJPOCFUXFFOUIFFRVJQNFOUBOESFDFJWFS t$POOFDUUIFFRVJQNFOUJOUPBOPVUMFUPOBDJSDVJUEJGGFSFOUGSPNUIFPOFJOXIJDIUIFUIFSFDFJWFS JTDPOOFDUFE t$POTVMUUIFEFBMFSPSBOFYQFSJFODFESBEJP57UFDIOJDJBOGPSIFMQ $IBOHFTPSNPEJmDBUJPOTDBOWPJEUIFVTFS}TBVUIPSJUZUPPQFSBUFUIFFRVJQNFOU '$$*%94: Statement: 5IJTEFWJDFDPNQMJFTXJUI1BSUPGUIF'$$3VMFT 0QFSBUJPOJTTVCKFDUUPUIFGPMMPXJOHUXPDPOEJUJPOT  UIJTEFWJDFNBZOPUDBVTFIBSNGVMJOUFS GFSFODF BOE  UIJTEFWJDFNVTUBDDFQUBOZJOUFSGFSFODFSFDFJWFE JODMVEJOHJOUFSGFSFODFUIBUNBZ DBVTFVOEFTJSFEPQFSBUJPO /PUF5IJTFRVJQNFOUIBTCFFOUFTUFEBOEGPVOEUPDPNQMZXJUIUIFMJNJUTGPSB$MBTT#EJHJUBMEFWJDF  QVSTVBOUUPQBSUPGUIF'$$3VMFT5IFTFMJNJUTBSFEFTJHOFEUPQSPWJEFSFBTPOBCMFQSPUFDUJPO BHBJOTUIBSNGVMJOUFSGFSFODFJOBSFTJEFOUJBMJOTUBMMBUJPO5IJTFRVJQNFOUHFOFSBUFT VTFTBOEDBO radiate radio frequency energy and, if not installed and used in accordance with the instructions, NBZDBVTFIBSNGVMJOUFSGFSFODFUPSBEJPDPNNVOJDBUJPOT)PXFWFS UIFSFJTOPHVBSBOUFFUIBUJOUFS GFSFODFXJMMOPUPDDVSJOBQBSUJDVMBSJOTUBMMBUJPO*GUIJTFRVJQNFOUEPFTDBVTFIBSNGVMJOUFSGFSFODFUP 4  Intended use )FBSJOHJOTUSVNFOUTBSFJOUFOEFEGPSIFBSJOHJNQBJSFEQFPQMFUPJNQSPWFUIFJSIFBSJOH List of countries: 1SPEVDUTBSFJOUFOEFEGPSXPSMEXJEFTBMFT 4QFDJmDBUJPOPGSFTUSJDUJPOT/POF 5IFTFQSPEVDUTBSFJOUFOEFEGPSXPSMEXJEFTBMFT BOEJODPNQMJBODFXJUIUIFGPMMPXJOHSFHVMBUPSZ requirements: t5IFEFWJDFDPOGPSNTUPUIF&TTFOUJBM3FRVJSFNFOUTBDDPSEJOHUP"OOFY*PG$PVODJM%JSFDUJWF &&$GPSNFEJDBMEFWJDFT .%% BOEFTTFOUJBMSFRVJSFNFOUTBOEPUIFSSFMFWBOUQSPWJTJPOTPG %JSFDUJWF&$ 355&  5IFEFDMBSBUJPOPGDPOGPSNJUZNBZCFDPOTVMUFEBUXXXSFTPVOEDPN t'PSUIF/PSXFHJBONBSLFUUIFBDDFTTPSJFTDPNQMZUP&/5FDIOJDBM"JETGPSEJTBCMFE persons t(FOFSBMSFRVJSFNFOUTBOEUFTUNFUIPETDPWFSFECZUIF&.$BOEFMFDUSJDBMTBGFUZUFTUTBDDPSEJOH UP&/*&$BOE&/*&$ t0UIFSJEFOUJmFEBQQMJDBCMFJOUFSOBUJPOBMSFHVMBUPSZSFRVJSFNFOUTJODPVOUSJFTPVUTJEF&6BOE64 1MFBTFSFGFSUPMPDBMDPVOUSZSFRVJSFNFOUTGPSUIFTFBSFBT t1SPEVDUTBSFDBUFHPSJ[FEBTSFDFJWFSDMBTTBDDPSEJOHUP%JSFDUJWF&&$PO3BEJP&RVJQ NFOUBOE5FMFDPNNVOJDBUJPOT5FSNJOBM&RVJQNFOU 355&  7 Introduction $POHSBUVMBUJPOTPOUIFQVSDIBTFPGZPVSOFXIFBSJOHJOTUSVNFOUT3F4PVOETJOOPWBUJWFTPVOE technology and design, combined with the customised device programming selected by your IFBSJOHDBSFQSPGFTTJPOBM XJMMNBLFIFBSJOHBNPSFFOKPZBCMFFYQFSJFODF)FBSJOHJOTUSVNFOUTXJMM FOBCMFZPVUPIFBSTPVOETUIBUZPVNBZOPUIBWFIFBSEJOZFBSTCFDBVTFPGZPVSIFBSJOHMPTT 1SBDUJDFBOEBQPTJUJWFBUUJUVEFBSFJNQPSUBOUJOMFBSOJOHUPVTFIFBSJOHJOTUSVNFOUT:PVS3F4PVOE JOTUSVNFOUTIBWFCFFOBEKVTUFEBDDPSEJOHUPZPVSJOEJWJEVBMIFBSJOHMPTTBOEOFFET4PNFQFPQMF BEKVTU RVJDLMZ UP XFBSJOH IFBSJOH JOTUSVNFOUT JO UIFJS FBST BOE IFBSJOH OFX TPVOET PUIFS QFPQMFNBZOFFENPSFUJNF 1MFBTFSFBEUIJTNBOVBMDBSFGVMMZJOPSEFSUPXIPMMZCFOFmUGSPNUIFVTFPGZPVSIFBSJOHJOTUSVNFOUT With proper care, maintenance, and usage, your hearing instruments will aid you in better communi DBUJPOGPSNBOZZFBST"TLZPVSIFBSJOHDBSFQSPGFTTJPOBMJGZPVIBWFBOZRVFTUJPOT ReSound is a registred trade mark of ReSound A/S )FBSJOHJOTUSVNFOUNPEFM #BUUFSZTJ[F 3FDFJWFSUVCFMFOHUI %PNFTJ[F Left serial number: 3JHIUTFSJBMOVNCFS  9 CONTENTS Introduction ........................6 Description of the hearing instruments ...10 Getting started.....................12 On/Off function ....................12 SmartStart........................12 Inserting/Replacing the battery.........13 Low battery indicator ................14 Inserting/removing hearing instruments...16 Operation of the hearing instrument .....19 Push button (Alera 61 only)............19 Flight mode .......................21 Telephone use ....................21 Listen to radio or TV.................23 Care and maintenance...............26 Daily maintenance ..................27 Cleaning the receiver tubes and domes ..29 Cleaning RIE moulds ................29 Replacing the wax filter (receiver in-the-ear models)............30 How to apply domes ................34 General precautions.................36 General warnings...................37 Battery warning Information ...........40 Troubleshooting guide ...............42 Technical data .....................50 Warranty and repairs ................51 7   2 7 9   2  4 3       /1SFDFJWFSUVCF )1SFDFJWFSUVCF -FGUSJHIUJOEJDBUPS .PEFM BOETFSJBMOVNCFS RIE BTE - AL961-DRW, AL761-DRW, AL561-DRW RIE Mini-BTE - AL960-DR, AL760-DR, AL560-DR 3FDFJWFSUVCF 3FDFJWFS0QFO%PNF 3FDFJWFS5VMJQ%PNF 3FDFJWFS1PXFS%PNF 3*&NPVME 4QPSUTMPDL #BUUFSZDPNQBSUNFOU 3FDFJWFS 1VTICVUUPO "MFSB"MFSB   BGVODUJPODBMMFE4NBSU4UBSU5IJTGVODUJPOXJMMEFMBZUIFUJNFJOXIJDIUIFIFBSJOHJOTUSVNFOUT UVSOPOCZUFOTFDPOETBGUFSUIFCBUUFSZDPNQBSUNFOUJTDMPTFE8JUI4NBSU4UBSU BCFFQXJMM CFIFBSEGPSFBDITFDPOEPGUIFEFMBZQFSJPE Inserting/Replacing the battery 0QFOUIFCBUUFSZEPPSDPNQMFUFMZCZVTJOHZPVSmOHFSOBJM 3FNPWFUIFVTFECBUUFSZ JGQSFTFOU*OTFSUUIFOFXCBUUFSZXJUIUIF QPTJUJWFTJEFJOUIFDPSSFDUQPTJUJPO "MXBZTVTFOFX;JOD"JSCBUUFSJFTUIBUIBWFBNJOJNVN SFNBJOJOHTIFMGMJGFPGZFBS (FOUMZDMPTFUIFCBUUFSZEPPS 5JQ3FNPWFUIFCBUUFSJFTUPQSFWFOUMFBLBHFXIFOUIFIFBSJOHJOTUSVNFOUTBSFOPUJOVTF GPSBOFYUFOEFEQF…

Text truncated - open the document above for the full version.

External Photos

Document Title: Doc. #: Rev. #: External photos of SY312 198070 A Form 0007380 - Rev I Short term confidential Page 1 of 3 Corp Template Not subject to issue control when printed Printed Date: 9 April 2010 Lautrupbjerg 7 P.O. Box 130 DK-2750 Ballerup Denmark Owner/Editor: Local Address, if applicable: Jesper Peitersen Date: 09.04.2010 Specifications according to item number 17079700. FRONT BACK Document Title: Doc. #: Rev. #: External photos of SY312 198070 A Form 0007380 - Rev I Short term confidential Page 2 of 3 Corp Template Not subject to issue control when printed Printed Date: 9 April 2010 TOP SIDE BOTTOM SIDE Document Title: Doc. #: Rev. #: External photos of SY312 198070 A Form 0007380 - Rev I Short term confidential Page 3 of 3 Corp Template Not subject to issue control when printed Printed Date: 9 April 2010 LEFT SIDE RIGHT SIDE

ID Label/Location Info

This document may not be reproduced or distributed in any way without the consent of GN ReSound A/S. This item will be used in electric or electronic equipment. The supplier warrants and represents that the item is, and at all times will be, in compliance with international regulations regarding substances with environmental impact, including but not limited to the RoHS Directive 2002/95 of the European parliament and of the Council. 5,86 4,59 6,82 7,82 8,26 8,98 1,80 6,39 6,00 1,79 1,70 3,53 01710010 BB BAT DR, RS, S312, LSR MK MDL. Number: 1730760 Name:DRW. Number:Rev. Mark:DRW. Rev.: Material: [dd-Mmm-yy] 09-Apr-10Sheet:1 of 1Date: Units: mm. Angular:Linear:Symetric:DRW. State: DevelopmentUpd. by:-Scale:5:1 Unless otherwise specifiedDesign: MDB ProjectionDRW. size:A4 FCC ID: X26SY312 SCALE 5:1

Internal Photos

Document Title: Doc. #: Rev. #: Internal photos of SY312 198060 A Form 0007380 - Rev I Short term confidential Page 1 of 2 Corp Template Not subject to issue control when printed Printed Date: 9 April 2010 Lautrupbjerg 7 P.O. Box 130 DK-2750 Ballerup Denmark Owner/Editor: Local Address, if applicable: Thomas Stubbe Teglbjærg Date: 09.04.2010 Specifications according to item number 17042000 : TOPSIDE Document Title: Doc. #: Rev. #: Internal photos of SY312 198060 A Form 0007380 - Rev I Short term confidential Page 2 of 2 Corp Template Not subject to issue control when printed Printed Date: 9 April 2010 BOTTOMSIDE

Test Report

DELTA Venlighedsvej 4 2970 Hørsholm Denmark Tel. +45 72 19 40 00 Fax +45 72 19 40 01 www.delta.dk VAT No. 12275110 DELTA Test Report TEST Reg. no. 19 The report must not be reproduced, except in full, without the written approval of DELTA. This report is issued under the rules of SWEDAC (Swedish Accreditation) and ILAC (Interna- tional Laboratory Accreditation Cooperation) including its MRA (Mutual Recognition Arrange- ment). Further information can be found at www.swedac.se and www.ilac.org. The report must not be reproduced, except in full, without the written approval of DELTA. This report is issued under the rules of DANAK (Danish Accreditation) and ILAC (International Laboratory Accreditation Cooperation) including its MRA (Mutual Recognition Arrangement). Further information can be found at www.danak.dk and www.ilac.org. The report must not be reproduced, except in full, without the written approval of DELTA. EMC_RepGen MAIN TEMPLATE V.45 / 2010-03-08 Radio parameter test of SY312 hearing instrument Performed for GN Hearing A/S DANAK-1910855, Rev. C Project no.: A506404-3 Page 1 of 46 15 April 2010 DANAK-1910855, Rev. C DELTA-A506404-3 Page 2 of 46 JAS/BLJ Title Radio parameter test of SY312 hearing instrument Test object SY312 hearing instrument Report no. DANAK-19 10855, Rev. C Project no. A506404-3 Test period 22 December 2009 to 13 April 2010 Client GN Hearing A/S Lautrupbjerg 7 2750 Ballerup Denmark Tel.: +45 45 75 11 11 Contact person Vinnie Nørager E-mail: [email protected] Manufacturer GN Hearing A/S Specifications FCC CFR 47 Part 15, Subpart C Results The test objects were found to be in compliance with the specifications, as listed in Section 1 Test personnel Claus Momme Thomsen Jan Askov DANAK-1910855, Rev. C DELTA-A506404-3 Page 3 of 46 JAS/BLJ Date 15 April 2010 Project Manager Jan Askov Senior Specialist, Wireless DELTA Responsible Claus Rømer Andersen Team Manager, Wireless DELTA This report is a revision of the test report A506404-3 Rev. B dated 14 April 2010. The revision has been made due to the following: Added tabular values for band edge measurements on page 30, 32 and 34. DANAK-1910855, Rev. C DELTA-A506404-3 Page 4 of 46 JAS/BLJ Table of contents Page 1. Summary of tests 5 2. Test objects 6 2.1 Test objects 6 3. General test conditions 7 3.1 Test setup during test 7 3.2 Description of radio link 8 3.3 Test sequence 9 4. Test results 10 4.1 Peak to Average Correction Factor (PACF) 10 4.2 Antenna requirement 12 4.3 Measurement of radiated emission, 0.009-30 MHz 14 4.4 Measurement of radiated emission, 30 MHz to 1000 MHz 19 4.5 Measurement of radiated emission, 1 GHz to 25 GHz 29 4.6 Measurement of band edge compliance 36 4.7 Measurement of field strength of fundamental 40 5. National registrations and accreditations 44 5.1 DANAK Accreditation 44 5.2 FCC Registrations 44 5.3 VCCI Registrations 45 5.4 IC Registrations 45 6. List of instruments 46 DANAK-1910855, Rev. C DELTA-A506404-3 Page 5 of 46 JAS/BLJ 1. Summary of tests Tests Test methods Rule Section Results Peak to Average Correction Factor (PACF) 15.35(c) N.A. Antenna requirement Visual inspection 15.203 Passed Measurements of radiated emission ANSI C63.4:200315.209 Passed Measurement of band edge compliance ANSI C63.4:2003 15.215(c) Passed Measurement of field strength of funda- mental ANSI C63.4:200315.249 Passed The given result is based on a shared risk principle with respect to the measurement un- certainty. Conclusion The test objects mentioned in this report meet the requirements of the standard stated be- low.  FCC CFR 47 Part 15, Subpart C Specific rule part 15.249. The test results relate only to the objects tested. DANAK-1910855, Rev. C DELTA-A506404-3 Page 6 of 46 JAS/BLJ 2. Test objects 2.1 Test objects Test object 2.1.1 Name of test object SY312 Model / type SY312 Part no. HI-V3 Serial no. EMC 2-Spurius Emissions-302 FCC ID X26SY312 Manufacturer GN Hearing A/S Supply voltage 1.3 VDC (Zinc Air battery) Software version Spurious emission firmware: Tx and Rx Deltatest090210 Cycle time 0.5 ms / 1.0 ms Comments Supplied by external power supply Test object 2.1.2 Name of test object SY312 Model / type SY312 Part no. HI-V3 Serial no. EMC 3-Conducted sample-272 FCC ID X26SY312 Manufacturer GN Hearing A/S Supply voltage 1.3 VDC (Zinc Air battery) Software version Spurious emission firmware: Tx and Rx Deltatest090210 Cycle time 0.5 ms / 1.0 ms Comments Antenna replaced by SMA connector and supplied by external power supply DANAK-1910855, Rev. C DELTA-A506404-3 Page 7 of 46 JAS/BLJ 3. General test conditions 3.1 Test setup during test Figure 3.1.1 Block diagram of test object. All test objects were running special test software. During test, the test objects were in continuous TX mode. (Normal modulation, normal data packets with optimized repetition rate) Tests were performed at three frequencies  Low frequency: 2404 MHz  Middle frequency: 2441 MHz  High frequency: 2478 MHz. During some tests, the battery was replaced by an external DC power supply. Intended use SY312 is a hearing aid used for alleviation of hearing loss. It can receive audio signals and be fitted or configured via the radio link. Size of the test object The test object measures 20 x 15 x 7 mm. Test object SY312 Radio link Audio External DC power supply DANAK-1910855, Rev. C DELTA-A506404-3 Page 8 of 46 JAS/BLJ 3.2 Description of radio link The radio of the test object has the following specified RF parameters: Antenna : Permanently attached PCB antenna Operating frequency range : 2404 to 2478 MHz Transmit power : 0 dBm Power level : No No of channels : 20 Bandwidth (Specification) : 2 MHz Channel separation : 2 MHz Modulation : GFSK Data rate : 2 Mbits Duty cycle : 10 % during normal mode Transmit mode : Yes Receive mode : Yes Standby mode : Yes Power supply : 1.3 V Zinc Air battery Specified min voltage: 1.19 V Specified max voltage: 1.4 V Temperature category : -20 to +55 ºC. DANAK-1910855, Rev. C DELTA-A506404-3 Page 9 of …

Text truncated - open the document above for the full version.

Test Setup Photos

DELTA Venlighedsvej 4 2970 Hørsholm Denmark Tel. +45 72 19 40 00 Fax +45 72 19 40 01 www.delta.dk VAT No. 12275110 Version l The report must not be reproduced, except in full, without the written approval of DELTA. Photos Radio parameter test of SY312 hearing instrument Performed for GN Hearing A/S Page 1 of 8 This exhibit is an extract of DELTA Test Report A506404-3 DANAK-191855, Rev. A dated 13 April 2010 containing only the photos of the test set-ups DELTA-A506404-3 Page 2 of 8 JAS/BLJ Photo 4.2.1 Test setup regarding measurement of Antenna requirement. Photo 4.2.2 Test setup regarding measurement of Antenna requirement. DELTA-A506404-3 Page 3 of 8 JAS/BLJ Photo Error! No text of specified style in document..1 Test setup regarding measure- ment of radiated emission, 0.009-30 MHz. Photo Error! No text of specified style in document..2 Test setup regarding measure- ment of radiated emission, 0.009-30 MHz. DELTA-A506404-3 Page 4 of 8 JAS/BLJ Photo Error! No text of specified style in document..3 Test setup regarding measure- ment of radiated emission, 0.009-30 MHz. Photo Error! No text of specified style in document..4 Test setup regarding measure- ment of radiated emission, 0.009-30 MHz. DELTA-A506404-3 Page 5 of 8 JAS/BLJ Photo 4.4.1 Test setup regarding measurement of radiated emission. Photo 4.4.2 Test setup regarding measurement of radiated emission. DELTA-A506404-3 Page 6 of 8 JAS/BLJ Photo 4.5.1 Test setup regarding measurement of radiated emission. Photo 4.5.2 Test setup regarding measurement of radiated emission. DELTA-A506404-3 Page 7 of 8 JAS/BLJ Photo 4.6.1 Test setup regarding measurement of band edge compliance. Photo 4.6.2 Test setup regarding measurement of band edge compliance. DELTA-A506404-3 Page 8 of 8 JAS/BLJ Photo 4.7.1 Test setup regarding measurement of field strength of fundamental. Photo 4.7.2 Test setup regarding measurement of field strength of fundamental.

Contact Information

Applicant

Nichlas Brown Holm
[email protected]+4523421388Fax: +4572111889

Test Firm

DELTA Electronic TestingJorgen Christensen
[email protected]45-4586-7722Fax: 45-4586-5898

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term

Other Applications from GN Hearing A/S

X26SM-3P

Accesory to wireless hearing instrument

Aug 12, 2024

Equipment Class

DTS - Digital Transmission System
Accesory to wireless hearing instrument - FCC ID X26SAS-4 - GN Hearing A/S
X26SAS-4

Accesory to wireless hearing instrument

Aug 24, 2023

Equipment Class

DTS - Digital Transmission System
Rechargeable wireless hearing instrument - FCC ID X26DURR1 - GN Hearing A/S
X26DURR1

Rechargeable wireless hearing instrument

Jul 10, 2023

Equipment Class

DTS - Digital Transmission System
Wireless hearing instrument - FCC ID X26CABR70 - GN Hearing A/S
X26CABR70

Wireless hearing instrument

Feb 21, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
X26WOE46R

Wireless hearing instrument

Jul 29, 2021

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter