FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. New Centurion Solutions, Inc./
  3. X9INCS04010910

X9INCS04010910HANDHELD SECURITY DEVICE

New Centurion Solutions, Inc.
HANDHELD SECURITY DEVICE - FCC ID X9INCS04010910 - New Centurion Solutions, Inc.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Apr 18, 2011
Application Purpose
Original Equipment
Date of Application
Apr 18, 2011
Equipment Note
HANDHELD SECURITY DEVICE
Frequency Range
902.50000000 - 927.50000000
Company
New Centurion Solutions, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

β†—
β†—
β†—

Block Diagram

β†—

Cover Letter(s)

β†—
β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—
β†—

Internal Photos

β†—

Operational Description

β†—

Parts List/Tune Up Info

β†—

RF Exposure Info

β†—

Test Report

β†—
β†—

Test Setup Photos

β†—
β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. Elliott Tech, LLC OREP Assembly Manual OREP New Centurion Solutions Project Number: 776 Reference: 776-91-04-REV-.docx Original Document: March 1, 2011 Revision A: March 16, 2011 Prepared for: Prepared by: New Centurion Solutions, Inc. Greg Williams 3011 Spring Garden St. Suite E Greensboro, NC 27403 (336) 617-5410 [email protected] Elliott Tech, LLC 346 Raleigh Street Holly Springs, NC 27540 (919) 342-6899 (888) 631-1795 Fax [email protected] OREP Assembly Manual 776-91-04-REV-A.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. ii Revision Page Rev Description Section A FCC Notification 3 OREP Assembly Manual 776-91-04-REV-A.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. iii Contents 1. Equipment List ......................................................................................................... 4 2. Assembly Instruction................................................................................................ 5 3. FCC Notification ...................................................................................................... 8 OREP Assembly Manual 776-91-04-REV-A.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. 4 1. EQUIPMENT LIST A. OREP Enclosure - Top (1) B. OREP PCB (1) C. OREP Enclosure - Bottom (1) D. 1/4” Tapping Screws for PCB (4) E. OREP Enclosure - Rubber Mat (1) F. 8” Bulkhead to Pigtail RF Cable (1) G. OREP Enclosure - Screws (4) H. Inmate Male Panel Receptacle with Lead Wires (1) I. OREP Spacer/Washer (4) J. Tenergy Battery (1) K. Double Sided Tape OREP Assembly Manual 776-91-04-REV-A.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. 5 2. ASSEMBLY INSTRUCTION To begin, check the parts available against the equipment list, identifying any missing parts. If all parts are accounted for, proceed to the instructions below to begin assembling the outdoor repeater (OREP). Step 1: Take the bottom enclosure (C) and place an OREP spacers/washers (I) over each of the inside screw holes as designated in the figure below. Lay the OREP PCB (B) over the bottom enclosure, making sure there is a spacer under each corner of the PCB. Insert a tapping screw (D) into each corner, mounting the PCB to the enclosure. Step 2: Identify the rubber mat and line the holes up with the elevated screw holes in each corner. Feed the openings on the rubber mat through the double pegs beside each elevated screw hole. Step 1 Step 2 OREP Assembly Manual 776-91-04-REV-A.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. 6 Step 3: Insert the panel receptacle (H) into the inside of the front enclosure with the pins facing out. Rotate the nut (with the text facing outwards) clockwise around the receptacle until it is flush against the bottom enclosure. Step 4: Take the bulkhead RF cable (F) and remove the nut and washer. Insert the bulkhead into the inside of the front enclosure with the pin facing out. Fasten the washer to the bulkhead (outside of the enclosure) and rotate the nut clockwise until it is flush against the bottom enclosure. Step 3 Step 4 OREP Assembly Manual 776-91-04-REV-A.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. 7 Step 5: Feed the wires from the panel receptacle into the terminal block labeled P1 on the PCB by pushing down on one orange tab and feeding the wire through the respective terminal. Looking down on the terminal block with the tabs on the right, the red wire should be inserted into the top terminal and the black wire should be inserted into the bottom as indicated in the figure below. Step 6: Insert the pigtail connector end of the RF cable into the RF port labeled J1 on the PCB by laying connector over the port and pressing down on the connector. The connector should snap right into place. Step 7: Insert the Tenergy battery (J) connector into the 3 pin header on the PCB beside the β€œon” switch. After doing so, apply a piece of double sided tape (K) to either side of the battery, and press the battery against the metal shields on the PCB. Step 5 Step 6 Step 7 OREP Assembly Manual 776-91-04-REV-A.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. 8 Step 8: Lay one side of the top enclosure over the bottom enclosure, making sure t…

Text truncated - open the document above for the full version.

Users Manual

THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. 1 Elliott Tech, LLC OREP Installation Manual OREP New Centurion Solutions Project Number: 776 Reference: 776-91-07-REV-OREP_INSTALLATION_MANUAL.docx Original Document: March 1, 2011 Revision A: March 16, 2011 Prepared for: Prepared by: New Centurion Solutions, Inc. Greg Williams 3011 Spring Garden St. Suite E Greensboro, NC 27403 (336) 617-5410 [email protected] Elliott Tech, LLC 346 Raleigh Street Holly Springs, NC 27540 (919) 342-6899 (888) 631-1795 Fax [email protected] OREP Installation Manual 776-91-07-REV-A_OREP_INSTALLATION_MANUAL.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. 2 Revision Page Rev Description Section A FCC Notification 3 OREP Installation Manual 776-91-07-REV-A_OREP_INSTALLATION_MANUAL.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. 3 Contents 1. Equipment List ................................................................................................................................. 4 2. Installation Instructions .................................................................................................................. 6 3. FCC Notification ............................................................................................................................ 11 OREP Installation Manual 776-91-07-REV-A_OREP_INSTALLATION_MANUAL.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. 4 1. EQUIPMENT LIST A. OREP assembly (1) B. Hardware to attach to OREP Bracket (4) C. Solar Bracket & Hardware (1) D. Bracket Hardware (2) E. Solar Panel (1) F. Panel Hardware (2) G. TN-Male to N-Male Pigtail 2 ft (2) H. Lightning Surge Protector (1) I. Mounting Base-Treated Plywood (1) J. Tripod Base (1) K. Hardware to attach tripod to base (3) L. Mast (1) M. Antenna 3db (1) N. Antenna Bracket (1) OREP Installation Manual 776-91-07-REV-A_OREP_INSTALLATION_MANUAL.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. 5 O. U-Bolt and mast attachment hardware (1) P. OREP Bracket (1) Q. U-Bolts, nuts, washers (2 sets) R. TN-Male to N-Male Pigtail 2 ft (2) S. Battery Box (1) T. 12V Battery (1) U. Battery Restraining Strap (2) OREP Installation Manual 776-91-07-REV-A_OREP_INSTALLATION_MANUAL.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. 6 2. INSTALLATION INSTRUCTIONS To begin, check the parts available against the equipment list, identifying any missing parts. If all parts are accounted for, proceed to the instructions below to begin installing the OREP. Step 1: Identify the Mounting Base-Treated Plywood (I). Place the plywood on the ground laying flat. Identify the Tripod Base (J), open its legs until fully extended, and center it on the plywood. Mark the points for the drill holes with a pencil and set aside the base. Drill 1/8” holes where they are marked on the plywood. Identify the Hardware to attach to OREP Bracket (B). Push the screws up through the drilled holes from the bottom of the plywood, and align the tripod base with the screws. Push the screws through the holes in the tripod base and secure with a washer and nut (from Hardware to attach to OREP Bracket (B)) on each screw. Make sure hardware is secure before proceeding to the next step. Step 2: Place Mast (L) down through the center of the Tripod Base (J). Tighten screws at the top and center of the Tripod Base (J) to secure the Mast (L). OREP Installation Manual 776-91-07-REV-A_OREP_INSTALLATION_MANUAL.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. 7 Step 3: Place Antenna 3db (M) through hole in Antenna Bracket (N) and secure at base of antenna. Step 4: Identify the U-Bolt and mast attachment hardware (O). Secure the antenna-bracket assembly to the mast by sliding a u-bolt through each hole in the bracket (from previous step) and around the mast. Secure the u-bolt on the mast with two nuts (included with u-bolt). Step 5: Place the OREP assembly (A) on the OREP Bracket (P) with the legs facing away. Identify the Hardware to attach to OREP Bracket (B). Insert four screws into the OREP enclosure holes and push through the holes in the bracket. Secure the OREP to the bracket by attaching four nuts to the screws on the backside of the bracket. Type-A Type-A OREP Installation Manual 776-91-07-REV-A_OREP_INSTALLATION_MANUAL.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN…

Text truncated - open the document above for the full version.

Users Manual

THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. Elliott Tech, LLC OREP Assembly Manual OREP New Centurion Solutions Project Number: 776 Reference: 776-91-04-REV-.docx Original Document: March 1, 2011 Prepared for: Prepared by: New Centurion Solutions, Inc. Greg Williams 3011 Spring Garden St. Suite E Greensboro, NC 27403 (336) 345-7411 [email protected] Elliott Tech, LLC 346 Raleigh Street Holly Springs, NC 27540 (919) 342-6899 (888) 631-1795 Fax [email protected] OREP Assembly Manual 776-91-04-REV-.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. ii Revision Page Rev Description Section OREP Assembly Manual 776-91-04-REV-.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. iii Contents 1. Equipment List ......................................................................................................... 4 2. Assembly Instruction................................................................................................ 5 OREP Assembly Manual 776-91-04-REV-.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. 4 1. EQUIPMENT LIST A. OREP Enclosure - Top (1) B. OREP PCB (1) C. OREP Enclosure - Bottom (1) D. 1/4” Tapping Screws for PCB (4) E. OREP Enclosure - Rubber Mat (1) F. 8” Bulkhead to Pigtail RF Cable (1) G. OREP Enclosure - Screws (4) H. Inmate Male Panel Receptacle with Lead Wires (1) I. OREP Spacer/Washer (4) J. Tenergy Battery (1) K. Double Sided Tape OREP Assembly Manual 776-91-04-REV-.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. 5 2. ASSEMBLY INSTRUCTION To begin, check the parts available against the equipment list, identifying any missing parts. If all parts are accounted for, proceed to the instructions below to begin assembling the outdoor repeater (OREP). Step 1: Take the bottom enclosure (C) and place an OREP spacers/washers (I) over each of the inside screw holes as designated in the figure below. Lay the OREP PCB (B) over the bottom enclosure, making sure there is a spacer under each corner of the PCB. Insert a tapping screw (D) into each corner, mounting the PCB to the enclosure. Step 2: Identify the rubber mat and line the holes up with the elevated screw holes in each corner. Feed the openings on the rubber mat through the double pegs beside each elevated screw hole. Step 1 Step 2 OREP Assembly Manual 776-91-04-REV-.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. 6 Step 3: Insert the panel receptacle (H) into the inside of the front enclosure with the pins facing out. Rotate the nut (with the text facing outwards) clockwise around the receptacle until it is flush against the bottom enclosure. Step 4: Take the bulkhead RF cable (F) and remove the nut and washer. Insert the bulkhead into the inside of the front enclosure with the pin facing out. Fasten the washer to the bulkhead (outside of the enclosure) and rotate the nut clockwise until it is flush against the bottom enclosure. Step 3 Step 4 OREP Assembly Manual 776-91-04-REV-.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. 7 Step 5: Feed the wires from the panel receptacle into the terminal block labeled P1 on the PCB by pushing down on one orange tab and feeding the wire through the respective terminal. Looking down on the terminal block with the tabs on the right, the red wire should be inserted into the top terminal and the black wire should be inserted into the bottom as indicated in the figure below. Step 6: Insert the pigtail connector end of the RF cable into the RF port labeled J1 on the PCB by laying connector over the port and pressing down on the connector. The connector should snap right into place. Step 7: Insert the Tenergy battery (J) connector into the 3 pin header on the PCB beside the β€œon” switch. After doing so, apply a piece of double sided tape (K) to either side of the battery, and press the battery against the metal shields on the PCB. Step 5 Step 6 Step 7 OREP Assembly Manual 776-91-04-REV-.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC. 8 Step 8: Lay one side of the top enclosure over the bottom enclosure, making sure that all of the wires/cables are tucked inside and that none are folded over as that may cause damage. Slowly close the enclosures together until the top enclosure is flush against …

Text truncated - open the document above for the full version.

Block Diagram

NCS-0201-0910 HUB NCS-0301-0910 IREP NCS-0401-0910 OREP NCS-0101-0910 PAS NCS-0501-0910 NCS-0601-0910 NCS-0701-0910 NCS-0801-0910 NCS-0901-0910 Company NCS Device 0000 Date 0910

External Photos

Outdoor Repeater External Photo’s Outdoor Repeater Antenna Connector Type - N Power Supply Power Supply Bottom Side of Device

ID Label/Location Info

FCC ID: X9INCS04010910 THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

ID Label/Location Info

OREP Device Top Case OREP Device Bottom Case OREP Device Bottom Case FCC Label Location

Internal Photos

Outdoor Repeater Internal Photo’s Outdoor Repeater GPS Module – pre-FCC certified RF Module – pre-FCC certified Digital Circuitry – can be shielded Radio Circuitry - Shielded Radio Circuitry - Shielded Digital Circuitry – can be shielded Opposite Side of Board Power Connector Antenna Connector Antenna Connector Power Connector

Operational Description

HUB: X9INCS02010910 The HUB is designed such that the UMC RF connector on the board outputs to an antenna (SMA connector) on the outside of the enclosure via an internal RF plug-SMA jack coaxial cable. The antenna connector for the HUB complies with FCC part 15.203 in that the antenna uses a unique coupling to the intentional radiator. Only the antenna furnished by ELLTC shall be used with the device. IREP: X9INCS03010910 The internal repeaters are designed such that the UMC RF connector on the board outputs to an antenna (SMA connector) on the outside of the enclosure via an internal RF plug-SMA jack coaxial cable. The external antenna connector for the IREP complies with FCC Part 15.203 in that the antenna uses a unique coupling to the intentional radiator. Only the antenna furnished by ELLTC shall be used with the device. OREP: X9INCS04010910 The outdoor repeaters are designed such that the UMC RF connector on the board outputs to a Type N antenna (Type N connector) on the outside of the enclosure via an internal bulkhead-RF plug coaxial cable. The external antenna connector for the OREP complies with FCC part 15.203 in that the antenna uses a unique coupling to the intentional radiator. Only the antenna furnished by ELLTC shall be used with the device.

Parts List/Tune Up Info

OREP Device Item QTYDes i g n at o r Des c r i p t i o n 1 M an u f ac t u r er M an u f ac t u r er Par t Nu m b er So u r c e/Rep /Di s t 11ANT1 1 Stage 15dB SMT Mount Active GPS Patch Antenna TaoglasAP.10C.01Arrow 21BT1 BATTERY LITHIUM 3.1V RECHARGE Seiko InstrumentsMS518SE-FL35ESeiko 31C1 CAP 2200PF 25V CERAMIC 0402 SMD Panasonic - ECGECJ-0EB1E222KArrow 45C4, C5, C46, C47, C221 CAP 22PF 50V CERAMIC 0402 SMD Panasonic - ECGECJ-0EC1H220JArrow 53C7, C201, C214 CAP CER 47PF 50V NP0 0402 Johanson Dielectrics Inc500R07N470JV4TArrow 615 C10, C12, C15, C17, C19, C22, C24, C26, C28, C30, C32, C40, C42, C115, C222CAP .1UF 10V CERAMIC X5R 0402 Panasonic - ECGECJ-0EB1A104KArrow 73C11, C21, C34 CAP CERAMIC 10UF 10V 0603 X5R Panasonic - ECGECJ-1VB1A106MArrow 85C13, C35, C37, C39, C41 CAP CER 4.7UF 10V Y5V 0603 Murata Electronics North AmericaGRM188F51A475ZE20DArrow 912 C14, C16, C18, C20, C23, C25, C27, C29, C31, C33, C36, C38CAP CERAMIC 1UF 10V X5R 0402 Panasonic - ECGECJ-0EB1A105MArrow 101C44 CAP .01UF 25V CERAMIC X7R 0402 Panasonic - ECGECJ-0EB1E103KArrow 116C45, C100, C101, C202, C203, C208 CAP 100PF 50V CERAMIC 0402 SMD Panasonic - ECGECJ-0EC1H101JArrow 121C114 CAP CER 5.1PF 50V C0G 0402 Murata Electronics North AmericaGRM1555C1H5R1DZ01DArrow 135C116, C204, C212, C213, C215 CAP CER 33PF 25V S 0402 UHI Q Johanson Technology Inc250R07S330GV4TArrow 142C205, C207 CAP CER 3.6PF 50V S 0402 UHI Q Johanson Technology Inc500R07S3R6BV4TArrow 151C206 CAP CER 6.2PF 50V S 0402 UHI Q Johanson Technology Inc500R07S6R2CV4TArrow 162C209, C226 CAP 10000PF 16V CERAMIC 0402 SMD Panasonic - ECGECJ-0EB1C103KArrow 171C210 CAP 1000PF 25V CERAMIC 0402 SMD Panasonic - ECGECJ-0EB1E102KArrow 184C211, C223, C224, C225 CAP 27PF 50V CERAMIC 0402 SMD Panasonic - ECGECJ-0EC1H270JArrow 191C216 CAP CER 10PF 50V S 0402 UHI Q Johanson Technology Inc500R07S100JV4TArrow 201C217 CAP CER 5.6PF 50V S 0402 UHI Q Johanson Technology Inc500R07S5R6CV4TArrow 211C218 CAP CER 3.3PF 50V S 0402 UHI Q Johanson Technology Inc500R07S3R3BV4TArrow 221C219 CAP 1.5PF 50V CERAMIC 0402 SMD Panasonic - ECGECJ-0EC1H1R5CArrow 231C220 CAP CER 10UF 16V X5R 20% 0805 AVX Corporation0805YD106MAT2AArrow 241C227 CAP CER 15PF 50V S 0402 UHI Q Johanson Technology Inc500R07S150JV4TArrow 253D4, D5 DIODE SCHOTTKY 500MA 20V 0603 Comchip TechnologyCDBU0520Arrow 261D6 DIODE SW 250MA 80V 150W SOT-523 Micro Commercial CoMMBD4448HT-TPArrow 271FB200 FERRITE CHIP 30 OHM 2200MA 0402 Murata Electronics North AmericaBLM15PD300SN1DArrow 282FLT200, FLT201 FILTER SAW ISM 915MHZ RFID SMD Murata Electronics North AmericaSAFEB915MAL0F00R12Arrow 291J1 CONN JACK UMC VERTICLE SMDEmerson Network Power Connectivity Solutions 128-0711-201Arrow 301J3 CONN HEADER VERT SGL 5POS GOLD 3M961105-0711-201Molex 311J4 ITW PANCON - JSA41G0 - Jumper Switch ITW PANCONJSA41G0Arrow 323L1, L2, R23 RES 0.0 OHM 1/16W 5% 0402 SMD, RES 0.0 OHM 1/16W 0402 SMD YageoRC0402JR-070RLArrow 333L201, L202, L206 INDUCTOR 10NH 500MA 0402 Murata Electronics North AmericaLQW15AN10NJ00DArrow 341L203 INDUCTOR 11NH .64A WW 0402 Wurth Electronics Inc744765111AArrow 351L204 CER INDUCTOR 27NH 0402 Johanson Technology IncL-07C27NJV6TArrow 361L205 CER INDUCTOR 2.2NH 0402 Johanson Technology IncL-07C2N2SV6TArrow 371L207 INDUCTOR MULTILAYER 1.6NH 0402 TDK CorporationMLG1005S1N6SArrow 381L208 CER INDUCTOR 15NH 0402 Johanson Technology IncL-07C15NJV6TArrow 391LS1 BUZZER MAGNETIC 3V 5MM SMD PUI AudioSMT-0540-S-RPUI Audio 401MD1 MODULE GPS Wi2Wi W 2SG0006-006F-11W W Roy Zappia 411MD100 MOD 802.15.4/ZIGB 900MHZ RF OUT PanasonicENW-59611N3AArrow 421MP1RF Shield, 27.89 x 17.96 x 2.5 mm (48 MHz)GenesisGTI09-60347 Rev6Ken Erickson 431MP2RF Shield, 18.97 x 23.47 x 2.5 mm (900 MHz)GenesisGTI09-60348 Rev5Ken Erickson 441P2 CONN HEADER 3POS 1.25MM VERT SMD Molex Connector Corporation53398-0371Arrow 451P3 SAMTEC - FTSH-105-01-L-DV-K - .050 X .050 SAMTECFTSH-105-01-L-DV-KArrow 465P4, P5, P6, P7, P8 CONN HEADER 2POS .100 VERT GOLD Molex Connector Corporation22-29-2021Arrow 471P200 CONN RECEPT COAX SWITCHING SMT Hirose Electric Co LtdMS-147(06)Arrow 483Q1, Q2, Q3 MOSFET N-CH 20V 200MA 3-DFN Diodes IncDMN2005LP4K-7Arrow 491Q4 MOSFET P-CH 20V 1.5A 3-DFN Diodes IncDMP2104LP-7Arrow 501Q5 MOSFET P-CH 20V 3.7A SOT23-3 Vishay/SiliconixSI2323DS-T1-E3Arrow 511R2 RES 174K OHM 1/10W 1% 0402 SMD Panasonic - ECGERJ-2RKF1743XArrow 526R3, R42, R100, R101, R200, R202 RES 1.0K OHM 1/16W 5% 0402 SMD Rohm SemiconductorMCR01MZPJ102Arrow 533R7, R201, R203 RES 0.0 OHM 1/16W 5% 0402 SMD Rohm SemiconductorMCR01MZPJ000Arrow 541R8 RES 20K OHM 1/10W 5% 0402 SMD Panasonic - ECGERJ-2GEJ203XArrow 551R10 RES 2.10K OHM 1/10W 1% 0402 SMD Panasonic - ECGERJ-2RKF2101XArrow 561R11 RES 71.5K OHM 1/10W 1% 0402 SMD Panasonic - ECGERJ-2RKF7152XArrow 576R12, R25, R26, R27, R28, R30 RES 10K OHM 1/10W 5% 0402 SMD Panasonic - ECGERJ-2GEJ103XArrow 581R13 RESISTOR 1.0 OHM 1/10W 5% 0603 Panasonic - ECGERJ-3GEYJ1R0VArrow 592R14, R15 RES 27.0 OHM 1/10W 1% 0402 SMD Panasonic - ECGERJ-2RKF27R0XArrow 601R16 RES 100K OHM 1/10W 5% 0402 SMD Panasonic - ECGERJ-2GEJ104XArrow 611R17 RES 1.00M OHM 1/10W 1% 0402 SMD Panasonic - ECGERJ-2RKF1004XArrow 621R18 RES 3.74M OHM 1/16W 1% 0402 SMDVishay/DaleCRCW 04023M74FKED Arrow 633R20, R21, R22 RES 300 OHM 1/10W 5% 0402 SMD Panasonic - ECGERJ-2GEJ301XArrow 641R24 RES 249K OHM 1/10W 1% 0402 SMD Panasonic - ECGERJ-2RKF2493XArrow 651R31 RES 200 OHM 1/10W 5% 0402 SMD Panasonic - ECGERJ-2GEJ201XArrow 661R36 RES 82 OHM 1/10W 5% 0603 SMD Panasonic - ECGERJ-3GEYJ820VArrow 671R37 RES 59.0 OHM 1/10W 1% 0603 SMD Panasonic - ECGERJ-3EKF59R0VArrow 682R40, R41 RES 5.1K OHM 1/10W 5% 0402 SMD Panasonic - ECGERJ-2GEJ512XArrow 691R43 RES 270 OHM 1/10W 5% 0603 SMD Panasonic - ECGERJ-3GEYJ271VArrow 702R204, R205 RES 120 OHM 1/10W 5% 0402 SMD Panasonic - ECGERJ-2GEJ121XArrow 711SEN1 Omnidirectional Tilt and Vibration Sensor SignalQuest Precision MicrosensorsSQ-SEN-200SignalQuest 721SW1 SWITCH TACT SPST W/O GND SMD Omron Electronics Inc-ECB DivB3U-1000PArrow 731SW2 SWITCH LIGHT TOUCH …

Text truncated - open the document above for the full version.

RF Exposure Info

Report Number: 11CA14739-Outdoor Repeater File Number: MC16660 Page 1 of 3 Model Number: Outdoor Repeater Client Name: Elliott Tech, LLC (FCC ID: X9INCS04010910) Page 1 of 3 1.1 Test Conditions and Results – MAXIMUM PERMISSIBLE EXPOSURE Test Description Maximum Permissible Exposure calculation is performed to ensure that this device meets RF exposure limits for its intended environment. This device is required to meet the General Population/Uncontrolled exposure limits. Basic Standard 47 CFR Part 1.1307 Industry Canada IC Safety Code 6 FCC Limits for Occupational/Controlled Exposure Frequency Range (MHZ) Electric Field Strength (E) (V/M) Magnetic Field Strength (H) (A/M) Power Density (S) (MW/CM 2 ) Averaging Time ο‚½E 2 ο‚½, ο‚½H 2 ο‚½. or S (MINUTES) 0.3 – 3.0 614 1.63 (100)* 6 3.0 - 30 1824/F 4.89/F (900/F 2 )* 6 30 - 300 61.4 0.163 1.0 6 300 – 1500 - - F/300 6 1500 – 100,000 - - 5.0 6 FCC Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mw/cm 2 ) Averaging Time ο‚½E 2 ο‚½, ο‚½H 2 ο‚½. or S (minutes) 0.3 - 1.34 614 1.63 (100)* 30 1.34 - 30 824/F 2.19/F (180/F 2 )* 30 30 - 300 27.5 0.073 0.2 30 300 – 1500 - - F/1500 30 1500 – 100,000 - - 1.0 30 Figure 1 MPE - EUT Configuration Settings Calculation is performed from conducted power and antenna gain measurements documented within this report. Report Number: 11CA14739-Outdoor Repeater File Number: MC16660 Page 2 of 3 Model Number: Outdoor Repeater Client Name: Elliott Tech, LLC (FCC ID: X9INCS04010910) Page 2 of 3 Background: Per the following guidance from OET Bulletin 65 Supplement C required minimum spacings are provided to the professional installer. Transmitter or Device Type 18 Output 19 Applicable Methods to Ensure Compliance 20 Transmitters using indoor antennas that operate at 20 cm or more from nearby persons >2.5 W at 915 MHz If the MPE distance is greater than that required for normal operation of the device, operating instructions, warning instructions and/or warning labels may be used to ensure compliance by indicating the minimal separation distance to comply with MPE limits. If the antennas are professionally installed to ensure compliance, warning instructions and warning labels are not necessary. =ο€Ό 2.5 W at 915 MHz or =< 4 W at 2450 MHz Transmitters operating at 2.5 W EIRP (1.5 W ERP) or less at 915 MHz, or at 4 W EIRP (2.4 W ERP) or less at 2450 MHz, generally are not expected to exceed MPE limits when nearby persons are 20 cm or more from most antennas. Therefore, special instructions and warnings are normally not necessary to ensure compliance. Figure 2 Duty Cycle Correction Factor (100 ms) Mode ON Duration (ms) Total Duration (ms) Duty Cycle Correction (dB) )log(20 100 )( ms msTX ο‚΄ Comments Short Pulse 14 101.4 Long Transmission 38 171.6 Total 52 273.0 -14.4 dB 52ms / 273ms = 19.0% Report Number: 11CA14739-Outdoor Repeater File Number: MC16660 Page 3 of 3 Model Number: Outdoor Repeater Client Name: Elliott Tech, LLC (FCC ID: X9INCS04010910) Page 3 of 3 Figure 3 MPE - Calculation MPE Calculation with highest EIRP: The highest conducted power was observed to be 617 mW and this measurement is used for the calculation. Limit is calculated at low channel (902.5 MHz) as exposure limit increases slightly with frequency in the operating band. Duty cycle is 14.4%. S = EIRP / (4 * Pi * R 2 ), Power Density = EIRP / (4 * Pi * R 2 ), where EIRP = Output Power * Antenna Gain Uncontrolled/General Exposure 0.617 Watt, 0.00 dBi antenna (Unity Gain), 20 cm spacing Operating Frequency 902.5 MHz Output Power (Peak) 0.617 Watts Antenna Gain 6.0 dB or (linear) 3.981(unitless) Separation Distance …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Greg Williams(Owner)
[email protected]336-345-7411Fax: 336-854-3588

Test Firm

UL LLCRick Titus
[email protected]847-664-3281Fax: 847-509-6321

Technical Specifications

#Rule PartsFrequency RangePower Output
115C902.5 MHz - 927.5 MHz640.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This unit requires professional installation, user installation is prohibited. Only the antenna(s) sold with this product are authorized for use and must be installed to provide a separation distance of at least 20cm from all persons. Device must not be co-located or operating in conjunction with any other antenna or transmitter. This device must transmit with a source-based time-averaging duty factor as described in this filing. Professional installers must be provided with antenna installation instructions. End-users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from New Centurion Solutions, Inc.

HANDHELD SECURITY DEVICE - FCC ID X9INCS03010910 - New Centurion Solutions, Inc.
X9INCS03010910

HANDHELD SECURITY DEVICE

Apr 18, 2011

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
HANDHELD SECURITY DEVICE - FCC ID X9INCS02010910 - New Centurion Solutions, Inc.
X9INCS02010910

HANDHELD SECURITY DEVICE

Apr 18, 2011

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
HANDHELD SECURITY DEVICE - FCC ID X9INCS01010910 - New Centurion Solutions, Inc.
X9INCS01010910

HANDHELD SECURITY DEVICE

Apr 12, 2011

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter