FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. TEAC Corporation/
  3. XEG-TN180BT-Q

XEG-TN180BT-QANALOG TURNTABLE

TEAC Corporation
ANALOG TURNTABLE - FCC ID XEG-TN180BT-Q - TEAC Corporation
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 31, 2022
Application Purpose
Original Equipment
Date of Application
May 30, 2022
Equipment Note
ANALOG TURNTABLE
Frequency Range
2402.00000000 - 2480.00000000
Company
TEAC Corporation
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ENGLISH FRANÇAIS ESPAÑOL DEUTSCH ITALIANO NEDERLANDS SVENSKA OWNER’S MANUAL MODE D’EMPLOI MANUAL DEL USUARIO BEDIENUNGSANLEITUNG MANUALE DI ISTRUZIONI GEBRUIKSAANWIJZING BRUKSANVISNING OPTN180BTTEA09 ANALOG TURNTABLE TN-180BT Z For European Customers Disposal of electrical and electronic equipment and batteries and/or accumulators a) All electrical/electronic equipment and waste batteries/accu- mulators should be disposed of separately from the municipal waste stream via collection facilities designated by the gov- ernment or local authorities. b) By disposing of electrical/electronic equipment and waste batteries/accumulators correctly, you will help save valuable resources and prevent any potential negative effects on human health and the environment. c) Improper disposal of waste electrical/electronic equipment and batteries/accumulators can have serious effects on the environment and human health because of the presence of hazardous substances in the equipment. d) The Waste Electrical and Electronic Equipment (WEEE) symbols, which show wheeled bins that have been crossed out, indicate that electrical/electronic equipment and batteries/accumulators must be col- lected and disposed of separately from household waste. If a battery or accumulator contains more than the specified values of lead (Pb), mercury (Hg), and/or cadmium (Cd) as defined in the Battery Directive (2006/66/EC, 2013/56/EU), then the chemical symbols for those elements will be indicated beneath the WEEE symbol. e) Return and collection systems are available to end users. For more detailed information about the disposal of old electri- cal/electronic equipment and waste batteries/accumulators, please contact your city office, waste disposal service or the shop where you purchased the equipment. Pb, Hg, Cd 2 IMPORTANT SAFETY INSTRUCTIONS CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. M The lightning flash with arrowhead in an equilat- eral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that could be of sufficient magnitude to constitute a risk of electric shock to persons. V The exclamation point in an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. CAUTION oDO NOT REMOVE THE EXTERNAL CASES OR CABINETS TO EXPOSE THE ELECTRONICS. NO USER SERVICEABLE PARTS ARE INSIDE. oIF YOU ARE EXPERIENCING PROBLEMS WITH THIS PRODUCT, CONTACT THE STORE WHERE YOU PURCHASED THE UNIT FOR A SERVICE REFERRAL. DO NOT USE THE PRODUCT UNTIL IT HAS BEEN REPAIRED. oUSE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED HEREIN MAY RESULT IN HAZARDOUS RADIATION EXPOSURE. 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this apparatus near water. 6) Clean only with dry cloth. 7) Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9) Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10) Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. 11) Only use attachments/accessories specified by the manufacturer. 12) Use only with the cart, stand, tripod, bracket, or table specified by the man- ufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combina- tion to avoid injury from tip-over. 13) Unplug this apparatus during lightning storms or when unused for long periods of time. 14) Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. oThe apparatus draws nominal non-operating power from the AC outlet with its POWER or STANDBY/ON switch not in the ON position. oThe mains plug is used as the disconnect device, the disconnect device shall remain readily operable. oCaution should be taken when using earphones or headphones with the product because excessive sound pressure (volume) from earphones or head- phones can cause hearing loss. IN USA/CANADA, USE ONLY ON 120V SUPPLY. CAUTION oDo not expose this apparatus to drips or splashes. oDo not place any objects filled with liquids, such as vases, on the apparatus. oDo not install this apparatus in a confined space such as a book case or similar unit. oThe apparatus should be located close enough to the AC outlet so that you can easily reach the power cord plug at any time. Model for USA Declaration of Conformity Model number: TN-180BT Trade name: TEAC Responsible party: 11 Trading Company, LLC Address: 3502 Woodview Trace #200 Indianapolis, IN 46268 U.S.A. URL: https://11tradingcompany.com/contact-us/ This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Info…

Text truncated - open the document above for the full version.

Cover Letter(s)

RF_160, Issue 04 TEAC CORPORATION Declaration of Authorization We Name: TEAC CORPORATION Address: 1-47 Ochiai, Tama-shi, Tokyo 206-8530,Japan City: Tokyo Country: Japan Declare that: Name Representative of agent: Daphne Liang (1) Agent Company name: SGS Compliance Certification Services Inc. Address: No.8,Jiucengling,Xinhua Dist., City: Tainan City. Country Taiwan R.O.C is authorized to apply for Certification of the following product(s): Product description: ANALOG TURNTABLE Type designation: TN-180BT Trademark: TEAC Validity/ expiry date 2022/12/30 on our behalf. Date: April 07, 2022 City: Tokyo, Japan Name: Akira Sekiguchi (2) Function: Manager Signature: Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.

Cover Letter(s)

FCC, Request for non-disclosure Date: 21-Nov-2018 RF_501, Issue 8 Page 1 of 1 Company Name: TEAC CORPORATION Address : 1-47 Ochiai, Tama-shi, Tokyo 206-8530,Japan City: Tokyo Country: Japan To: Telefication B.V., Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject: Request for confidentiality FCC ID: XEG-TN180BT-Q Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, a pplicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Date: April 07, 2022 Name and signature of applicant: Akira Sekiguchi Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should stated in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period

External Photos

Page: 88 / 97 Report No.: TMTN2202000247NR Ref. No.: Rev.: 00 APPENDIX II PHOTOGRPHS OF EUT External Photo Model: TN-180BT Page: 89 / 97 Report No.: TMTN2202000247NR Ref. No.: Rev.: 00 Page: 90 / 97 Report No.: TMTN2202000247NR Ref. No.: Rev.: 00 Page: 91 / 97 Report No.: TMTN2202000247NR Ref. No.: Rev.: 00

Internal Photos

Page: 92 / 97 Report No.: TMTN2202000247NR Ref. No.: Rev.: 00 Internal Photo Model: TN-180BT Page: 93 / 97 Report No.: TMTN2202000247NR Ref. No.: Rev.: 00 Page: 94 / 97 Report No.: TMTN2202000247NR Ref. No.: Rev.: 00 Page: 95 / 97 Report No.: TMTN2202000247NR Ref. No.: Rev.: 00 Page: 96 / 97 Report No.: TMTN2202000247NR Ref. No.: Rev.: 00 Page: 97 / 97 Report No.: TMTN2202000247NR Ref. No.: Rev.: 00 Antenna

RF Exposure Info

Project No.: TM-2202000339P FCC ID: XEG-TN180BT-Q Page: 1 / 7 Report No.: TMWK2204001489KR Rev.: 00 No.11, Wugong 6th Rd., Wugu Dist., New Taipei City , Taiwan /新北市五股區五工六路11號 t:(886-2) 2299-9720 f:(886-2) 2299-9721 www.sgs.com.tw www.ccsrf.com Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of client’s instruction, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced, except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Compliance Certification Services Inc. 程智科技股份有限公司 Member of the SGS Group KDB 447498 D03 47 C.F.R. Part 1, Subpart I, Section 1.1310 47 C.F.R. Part 2, Subpart J, Section 2.1091 RF EXPOSURE REPORT For ANALOG TURNTABLE Model: TN-180BT Data Applies To: N/A Trade Name: TEAC Issued to TEAC CORPORATION 1-47 Ochiai, Tama-shi, Tokyo 206-8530,Japan Issued By Compliance Certification Services Inc. No.11, Wugong 6th Rd., Wugu Dist., New Taipei City 24891, Taiwan. (R.O.C.) Issued Date: May 05, 2022 Page: 2 / 7 Report No.: TMWK2204001489KR Ref. No.: T200610N03-MF Rev.: 00 REVISION HISTORY Rev. Issue Date Revisions Effect Page Revised By 00 May 05, 2022 Initial Issue ALL Angel Cheng 01 September 19, 2019 See the following note rev.01 ALL Angel Cheng Note: ※ Rev.00 Issue Date: March 15, 2022 Update for Class II Permissive Change Report (T210713N01-RP1-1 & T210713N01-RP1-2) Note: ※ Rev.00 Issue Date: August 27, 2019 Original Report ※ Rev.01 Issue Date: September 19, 2019 Revise EUT Specification. Page: 3 / 7 Report No.: TMWK2204001489KR Ref. No.: T200610N03-MF Rev.: 00 TABLE OF CONTENTS 1. LIMIT ........................................................................................................................... 4 2. EUT SPECIFICATION ............................................................................................ 5 3. TEST RESULTS ...................................................................................................... 6 4. MAXIMUM PERMISSIBLE EXPOSURE............................................................ 7 Page: 4 / 7 Report No.: TMWK2204001489KR Ref. No.: T200610N03-MF Rev.: 00 1. TEST RESULT CERTIFICATION We hereby certify that: The equipment has been tested by Compliance Certification Services Inc., and found compliance with the requirement of the applicable standards. The test record, data evaluation and Equipment under Test (EUT) configurations represented herein are true and accurate accounts of the measurement of the sample’s RF characteristics under the conditions specified in this report. APPLICABLE STANDARDS STANDARD TEST RESULT KDB 447498 D03 47 C.F.R. Part 1, Subpart I, Section 1.1310 47 C.F.R. Part 2, Subpart J, Section 2.1091 No non-compliance noted Statements of Conformity Determining compliance shall be based on the results of the compliance measurement, not taking into account measurement instrumentation uncertainty. Approved by: Kevin Tsai Deputy Manager Compliance Certification Services Inc. Page: 5 / 7 Report No.: TMWK2204001489KR Ref. No.: T200610N03-MF Rev.: 00 2. LIMIT According to §15.247(i), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission's guidelines. See § 1.1307(b)(1) of this chapter. 3. EUT SPECIFICATION EUT ANALOG TURNTABLE Model TN-180BT Brand TEAC RF Module Brito Model: MD-BLT-QR3040I Frequency band (Operating) 802.11b/g/n HT20: 2412MHz ~ 2462MHz 802.11n HT40: 2422MHz ~ 2452MHz Others 2402MHz ~ 2480MHz (BT3.0 BT 4.0 BT5.0) Device category Portable (<20cm separation) Mobile (>20cm separation) Others Exposure classification Occupational/Controlled exposure (S = 5mW/cm 2 ) General Population/Uncontrolled exposure (S=1mW/cm 2 ) Antenna Specification PCB Antenna / Gain: 1.45 dBi (Numeric gain: 1.40) worst Maximum Average output power GFSK: -0.337 dBm (0.925 mW) 8-DPSK -1.527 dBm (0.704 mW) GFSK(4.0) -4.173 dBm (0.383 mW) GFSK(5.2) -4.449 dBm (0.359 mW) Maximum Tune up Power GFSK: -0.2 dBm (0.955 mW) 8-DPSK: -1.0 dBm (0.794 mW) GFSK(4.0) -3.7 dBm (0.427 mW) GFSK(5.2) -4.0 dBm (0.398 mW) Evaluation applied MPE Evaluation* SAR Evaluation N/A Reported Date April 06, 2022 Note: RF power data reference report (TMTN2202000247NR & TMTN2202000248NR) Page: 6 / 7 Report No.: TMWK2204001489KR Ref. No.: T200610N03-MF Rev.: 00 4. TEST RESULTS No non-compliance noted. Calculation Given d GP E  = 30 & 377 2 E S= Where E = Field strength in Volts / meter P = Power in Watts G = Numeric antenna gain d = Distance in meters S = Power density in milliwatts / square centimeter Combining equations and re-arranging the terms to express the distance as a function of the remaining variables yields: 2 377 30 d GP S  = Changing to units of mW and cm, using: P (mW) = P (W) / 1000 and d (cm) = d(m) / 100 Yields () () 22 0796.0 100/377 1000/30 d GP d GP S  =   = Equation 1 Where d = Distance in cm P = Pow…

Text truncated - open the document above for the full version.

Test Report

Project No.: TM-2202000339P FCC ID: XEG-TN180BT-Q Page: 1 / 97 Report No.: TMTN2202000247NR Rev.: 00 No.8, Jiucengling, Xinhua Dist., Tainan City, Taiwan /台南市新化區礁坑里九層嶺8號 t:(886-6) 5802-201 f:(886-6) 5802-202 www.sgs.com.tw www.ccsrf.com Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of client’s instruction, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced, except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Compliance Certification Services Inc. 程智科技股份有限公司 Member of the SGS Group FCC 47 CFR PART 15 SUBPART C AND ANSI C63.10: 2013 TEST REPORT For ANALOG TURNTABLE Model: TN-180BT Brand: TEAC Issued for TEAC CORPORATION 1-47 Ochiai, Tama-shi, Tokyo 206-8530,Japan Issued by Compliance Certification Services Inc. Tainan Lab. No.8, Jiucengling, Xinhua Dist., Tainan City, Taiwan Issued Date: May 24, 2022 Note: This report shall not be reproduced except in full, without the written approval of Compliance Certification Services Inc. Ltd. This document may be altered or revised by Compliance Certification Services Inc. personnel only, and shall be noted in the revision section of the document Page: 2 / 97 Report No.: TMTN2202000247NR Ref. No.: Rev.: 00 REVISION HISTORY Rev. Issue Date Revisions Effect Page Revised By 00 May 24, 2022 Initial Issue ALL Polly Wang 01 July 27, 2021 See the following note rev.01 P.5 Polly Wang 02 July 16, 2019 See the following note rev.02 ALL Gina Lin Note: ※ Rev.00 Issue Date: July 27, 2021 Original report. ※ Rev.01 Issue Date: July 27, 2021 Revised the typo. Page: 3 / 97 Report No.: TMTN2202000247NR Ref. No.: Rev.: 00 TABLE OF CONTENTS 1. TEST REPORT CERTIFICATION ............................................................................................. 4 2. TEST RESULT SUMMARY ....................................................................................................... 5 3. EUT DESCRIPTION .................................................................................................................. 6 3.1 DESCRIPTION OF EUT & POWER ................................................................................................. 6 4. DESCRIPTION OF TEST MODES ............................................................................................ 7 5. TEST METHODOLOGY ............................................................................................................ 8 6. FACILITIES AND ACCREDITATIONS ...................................................................................... 8 6.1 FACILITIES ...................................................................................................................................... 8 6.2 EQUIPMENT .................................................................................................................................... 8 6.3 LABORATORY ACCREDITATIONS LISTINGS ............................................................................... 8 6.4 TABLE OF ACCREDITATIONS AND LISTINGS ............................................................................. 9 6.5 MEASUREMENT EQUIPMENT USED .......................................................................................... 10 7. CALIBRATION AND UNCERTAINTY ..................................................................................... 11 7.1 MEASURING INSTRUMENT CALIBRATION ................................................................................ 11 7.2 MEASUREMENT UNCERTAINTY ................................................................................................. 11 8. SETUP OF EQUIPMENT UNDER TEST ................................................................................. 12 8.1 SETUP CONFIGURATION OF EUT .............................................................................................. 12 8.2 SUPPORT EQUIPMENT ................................................................................................................ 13 8.3 EUT OPERATING CONDITION ..................................................................................................... 14 9. APPLICABLE LIMITS AND TEST RESULTS ......................................................................... 16 9.1 6DB BANDWIDTH .......................................................................................................................... 16 9.2 MAXIMUM PEAK OUTPUT POWER ............................................................................................. 22 9.3 DUTY CYCLE ................................................................................................................................. 34 9.4 POWER SPECTRAL DENSITY ..................................................................................................... 40 9.5 CONDUCTED SPURIOUS EMISSION .......................................................................................... 46 9.6 RADIATED EMISSIONS .................…

Text truncated - open the document above for the full version.

Test Setup Photos

Page: 83 / 97 Report No.: TMTN2202000247NR Ref. No.: Rev.: 00 APPENDIX I SETUP PHOTOS RADIATED EMISSION MEASUREMENT SETUP Below 1GHz Page: 84 / 97 Report No.: TMTN2202000247NR Ref. No.: Rev.: 00 Page: 85 / 97 Report No.: TMTN2202000247NR Ref. No.: Rev.: 00 RADIATED RF MEASUREMENT SETUP Page: 86 / 97 Report No.: TMTN2202000247NR Ref. No.: Rev.: 00 RF CONDUCTED SETUP Page: 87 / 97 Report No.: TMTN2202000247NR Ref. No.: Rev.: 00 CONDUCTED EMISSION MEASUREMENT SETUP MODE: NORMAL OPERATION

Contact Information

Applicant

AKIRA SEKIGUCHI(Group Leader)
[email protected]+81-42-356-9243Fax: +81-42-356-9187

Technical Contact

Compliance Certification Services Inc. Tainan Lab.Daphne Liang
[email protected]886-6-580-2201

No.8,Jiucengling, Xinhua Dist., · Taiwan

Non-Technical Contact

Compliance Certification Services Inc. Tainan Lab.Daphne Liang
[email protected]886-6-580-2201

Test Firm

Compliance Certification Services Inc.Daphne Liang
[email protected]886-6-5802201Fax: 886-6-5802202

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz400.00 µW
Confidentiality
Long Term
Grant Notes
Power Output is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End users must be provided with specific operating instructions for satisfying RF exposure compliance.

Other Applications from TEAC Corporation

Podcast Recording Console - FCC ID XEG-MIXCAST4 - TEAC Corporation
XEG-MIXCAST4

Podcast Recording Console

Nov 28, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Recorder - FCC ID XEG-MODEL24Q - TEAC Corporation
XEG-MODEL24Q

Recorder

Jan 06, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
USB DAC AMPLIFIER - FCC ID XEG-AI303 - TEAC Corporation
XEG-AI303

USB DAC AMPLIFIER

Dec 01, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Analog Turntable - FCC ID XEG-TN400BT-X - TEAC Corporation
XEG-TN400BT-X

Analog Turntable

Nov 23, 2022

Equipment Class

DTS - Digital Transmission System
ANALOG TURNTABLE - FCC ID XEG-TN400BT-Q - TEAC Corporation
XEG-TN400BT-Q

ANALOG TURNTABLE

Jun 14, 2022

Equipment Class

DTS - Digital Transmission System