FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zylux Acoustic Corporation/
  3. XN6-SB2020NJ6

XN6-SB2020NJ620-Inch Sound Bar 2.0 System

Zylux Acoustic Corporation
20-Inch Sound Bar 2.0 System - FCC ID XN6-SB2020NJ6 - Zylux Acoustic Corporation
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jan 21, 2021
Application Purpose
Original Equipment
Date of Application
Jan 21, 2021
Equipment Note
20-Inch Sound Bar 2.0 System
Frequency Range
2402.00000000 - 2480.00000000
Company
Zylux Acoustic Corporation
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Please read this guide before using the product. USER MANUALUSER MANUAL Model: SB2021n-H6 VIZIO 20" 2.0 Channel Sound Bar with Wireless Subwoofer and Bluetooth Model: SB2020n-J6 English - ii Your Unit is designed and manufactured to operate within defined design limits, and misuse may result in electric shock or fire. To prevent your Unit from being damaged, the following rules should be observed for its installation, use, and maintenance. Please read the following safety instructions before operating your Unit. Keep these instructions in a safe place for future reference. • Read these instructions. • Keep these instructions. • Heed all warnings. • Follow all instructions. • Do not use this apparatus near water. • Clean only with a dry cloth. • Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. • Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. • Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. • Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. • Only use attachments/accessories specified by the manufacturer. • Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. • Unplug this apparatus during lightning storms or when unused for long periods of time. • Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as when the power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. • To reduce the risk of electric shock or component damage, switch off the power before connecting other components to your Unit. • Unplug the power cord before cleaning your Unit. A damp cloth is sufficient for cleaning. Do not use a liquid or a spray cleaner on your Unit. Do not use abrasive cleaners. • Always use the accessories recommended by the manufacturer to insure compatibility. • When moving your Unit from an area of low temperature to an area of high temperature, condensation may form in the housing. Wait before turning on your Unit to avoid causing fire, electric shock, or component damage. • Slots and openings in the back and bottom of the cabinet are provided for ventilation. To ensure reliable operation of your Unit and to protect it from overheating, be sure these openings are not blocked or covered. Do not place your Unit in a bookcase or cabinet unless proper ventilation is provided. • Never push any object into the slots and openings on your Unit enclosure. Do not place any objects on the top of your Unit. Doing so could short circuit parts causing a fire or electric shock. Never spill liquids on your Unit. • WARNING: Exposure to loud sounds can damage your hearing causing hearing loss and tinnitus (ringing or buzzing in the ears). With continued exposure to loud noises, ears may become accustomed to the sound level, which may result in permanent damage to hearing without any noticeable discomfort. • When connected to a power outlet, power is always flowing into your Unit. To totally disconnect power, unplug the power cord. • Do not overload power strips and extension cords. Overloading can result in fire or electric shock. IMPORTANT SAFETY INSTRUCTIONS English - iii • The wall socket should be located near your Unit and be easily accessible • Keep your Unit away from moisture. Do not expose your Unit to rain or moisture. If water penetrates into your Unit, unplug the power cord and contact your dealer. Continuous use in this case may result in fire or electric shock. • Do not use your Unit if any abnormality occurs. If any smoke or odor becomes apparent, unplug the power cord and contact your dealer immediately. Do not try to repair your unit yourself. • Avoid using dropped or damaged appliances. If your Unit is dropped and the housing is damaged, the internal components may function abnormally. Unplug the power cord immediately and contact your dealer for repair. Continued use of your Unit may cause fire or electric shock. • Do not install your Unit in an area with heavy dust or high humidity. Operating your Unit in environments with heavy dust or high humidity may cause fire or electric shock. • Ensure that the power cord and any other cables are unplugged before moving your Unit. • When unplugging your Unit, hold the power plug, not the cord. Pulling on the power cord may damage the wires inside the cord and cause fire or electric shock. When your Unit will not be used for an extended period of time, unplug the power cord. • To reduce risk of electric shock, do not touch the connector with wet hands. • Insert the remote control batteries in accordance with instructions. Incorrect polarity may cause the battery to leak which can damage the remote control or injure the operator. • See the important note and rating located on the back of the unit. • WARNING - This equipment is not waterproof. To prevent a fire or shock hazard, do not place any container filled with liquid near the equipment (such as a vase or flower pot) or expose it to dripping, splashing, rain, or moisture. • CAUTION - Danger of explosion or fire if batteries are mistreated. Replace only with the same or specified type. • Do not leave the batteries exposed to direct sunlight for a…

Text truncated - open the document above for the full version.

External Photos

Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 1 of 7 Report No.: 201022KH17 External Photos of the EUT Model: SB2020n-J6 Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 2 of 7 Report No.: 201022KH17 Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 3 of 7 Report No.: 201022KH17 Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 4 of 7 Report No.: 201022KH17 Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 5 of 7 Report No.: 201022KH17 Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 6 of 7 Report No.: 201022KH17 Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 7 of 7 Report No.: 201022KH17

ID Label/Location Info

ZYLUX Acoustic Corporation DRAWER.:COLOR. DESIGN.CHECKED.APPROVAL. NO.MATERIAL. SCALE: PART NO.: TITLE. DATE: MODEL.: SHEETREV CHANGE RECORDSDATEREVISER PROJECTION 3RD ANGLE ABCDE 5 4 3 1 2 1 2 3 5 4 CABDE ISS B C A E D PROTOTYPE-A4 2020/10/20 LIANGQIAO LIANGQIAO LIANGQIAO Soundbar產品標籤 黑底白字印刷 100#合成紙+啞膜 亞克力膠 K1203-0008804 A1/1 N/A POBBYYONG 1 : 1 TS-0000102AB SB2020n-J6 TOLERANCES ±0.3 ±0.6 ±0.25 ±0.1 ±0.2 16~63 150~250 250~500 63~150 ~16 ±0.05 ±0.4 ±0.2 ±0.1 ±0.15 A ±0.6 ±0.8 ±0.2 ±0.4 ±0.5 BC ±1 ±1.5 ±0.4 ±0.6 ±0.8 D ANGLE ± ` ± 1` ± 10` ± 15` ± 30` 2020/10/20 NOTE : 1. IF TOLERANCE FOR EACH DIMENSIONS NOT SHOWN, REFER TO TABLE <B> TABLE FOR TOLERANCE. 2. USE R=1.0MM FOR ALL RADII NOT SPECIFIED. 3. UNACCEPTABLE CONDITIONS: FLASH, SHRINKAGE, DEFORMATION, AND/OR SPOTS. 4. REPRESENTS REVISIONS OR NEW DIMENSIONS. 5. REPRESENTS CRITICAL AREAS TO BE MEASURED. ALL OTHER DIMENSIONS ARE FOR REFERANCE. 6. THE MOULD NUMBER: NO 7. TEXTURE NUMBER: NO 8. ALL SUBSTANCE NEED TO MEET THE ROHS2.0 / REACH REQUIREMENTS. DETAILS REFER TO ZYLUX'S PROCEDURE "QMI-P40-01". 9. WILL USE ±0.05MM INNER DIAMETER FOR THE SCREW WHICH NOT SPECIFIED THE DETAILED DIMENSION. FCC ID: XN6-SB2020NJ6 For DTS patents, see http://patents.dts.com. 80±0.2mm 50.1±0.2mm R=2.6mm R=2.1mm R=2.6mm R=2.1mm 39 Tesla, Irvine, CA 92618 www.vizio.com Model No. : SB2020n-J6 Made in China Input : 100-240V , 50/60Hz, 10W Label Location

Internal Photos

Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 1 of 13 Report No.: 201022KH17 Internal photos of the EUT Model: SB2020n-J6 Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 2 of 13 Report No.: 201022KH17 Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 3 of 13 Report No.: 201022KH17 Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 4 of 13 Report No.: 201022KH17 Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 5 of 13 Report No.: 201022KH17 BT ANT BT Module Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 6 of 13 Report No.: 201022KH17 Power board: DSP120-120100W Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 7 of 13 Report No.: 201022KH17 Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 8 of 13 Report No.: 201022KH17 Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 9 of 13 Report No.: 201022KH17 Power board:CS12J120100FO Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 10 of 13 Report No.: 201022KH17 Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 11 of 13 Report No.: 201022KH17 Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 12 of 13 Report No.: 201022KH17 Remote controller Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 13 of 13 Report No.: 201022KH17

RF Exposure Info

Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 1 of 6 Report No.: 201022KH17-FE RF Exposure Report FCC ID: XN6-SB2020NJ6 Applicant: Zylux Acoustic Corporation Address: 7F, 70, Rui Guang Road, Neihu District, Taipei 114, Taiwan Manufacturer Zylux Acoustic Corporation Address 7F, 70, Rui Guang Road, Neihu District, Taipei 114, Taiwan Product: 20" Sound Bar 2.0 System Brand: Test Model(s): SB2020n-J6 Series Model(s): N/A Test Date: Dec.24, 2020 ~ Jan. 08, 2021 Issued By: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China FCC Designation No.: CN1255 Standards: FCC Part 2 (Section 2.1091) KDB 447498 D01 IEEE C95.1 The above equipment has been tested by Hwa-Hsing (Dongguan) Testing Co., Ltd., and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report Prepared by : Date: Jan. 12, 2021 Scott He/Engineer Approved by : Date: Jan. 15, 2021 Harry Li/ Supervisor This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any agency of the federal government. The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 2 of 6 Report No.: 201022KH17-FE Table of contents Release control record ................................................................................................ 3 1 General Information of EUT ............................................................................. 4 2 RF exposure limit ............................................................................................. 5 3 Calculation result of maximum conducted power ............................................. 5 Appendix – Information on the Testing Laboratories ................................................... 6 Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 3 of 6 Report No.: 201022KH17-FE Release control record Issue No. Reason for change Date issued 201022KH17-FE Original release Jan. 15, 2021 Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 4 of 6 Report No.: 201022KH17-FE 1 General Information of EUT Product 20" Sound Bar 2.0 System Brand Test Model(s) SB2020n-J6 Series Model(s) N/A FCC ID: XN6-SB2020NJ6 Status of EUT Engineering prototype Power Supply Rating AC100-240V~50/60Hz, 10W Modulation Type GFSK, π/4DQPSK,8DPSK Modulation technology FHSS Transfer Rate 1/2/3 Mbps Operating Frequency 2402 ~ 2480 MHz Number of Channel 79 Maximum Output Power 4.82dBm Antenna Type PCB Antenna Max. Peak ANT Gain 4.1dBi Antenna Connector N/A Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications or the user's manual. 2. For the test results, the EUT had been tested with all conditions. But only the worst case was shown in test report. 3. Please refer to the EUT photo document for detailed product photo (Reference No.: 201022KH17). 4. For the test results, the EUT had been tested with all power board, the worst case was show in test report. Power board difference: Manufacturer Model Input Output DONGGUAN DONGSONG ELECTRONIC CO., LTD DSP120-120100W 100-240Vac 50/60Hz 0.5A max. 12Vdc, 1.0A Chou Sen Electronics Co., LTD CS12J120100FO 100-240Vac 50/60Hz 0.5A max. 12Vdc, 1.0A Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 5 of 6 Report No.: 201022KH17-FE 2 RF exposure limit Limits for maximum permissible exposure (MPE) Limits for general population / uncontrolled exposure Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Average time (minutes) 300-1500 ... ... F/1500 30 1500-100,000 ... ...…

Text truncated - open the document above for the full version.

Test Report

Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 1 of 52 Report Version: V1.1.1 Test Report No.: 201022KH17-FR Test Report FCC ID: XN6-SB2020NJ6 Applicant: Zylux Acoustic Corporation Address: 7F, 70, Rui Guang Road, Neihu District, Taipei 114, Taiwan Manufacturer: Zylux Acoustic Corporation Address: 7F, 70, Rui Guang Road, Neihu District, Taipei 114, Taiwan Product: 20" Sound Bar 2.0 System Brand: Test Model(s): SB2020n-J6 Series Model(s): N/A Test Date: Dec.25, 2020 ~ Jan. 08, 2021 Issued By: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China FCC Designation No.: CN1255 Standards: 47 CFR FCC Part 15, Subpart C (Section 15.247) ANSI C63.10:2013 The above equipment has been tested by Hwa-Hsing (Dongguan) Testing Co., Ltd., and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. Prepared by : Date: Jan. 12, 2021 Scott He/ Project Engineer Approved by : Date: Jan. 15, 2021 Harry Li/ Technical Director This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any agency of the federal government. The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Hwa-Hsing (Dongguan) Testing Co., Ltd. No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Page 2 of 52 Report Version: V1.1.1 Test Report No.: 201022KH17-FR Table of Contents Release Control Record .................................................................................................................................. 4 1 Summary of Test Results ........................................................................................................................... 5 1.1 Measurement Uncertainty ..................................................................................................................... 5 1.2 Modification Record .............................................................................................................................. 5 2 General Information ................................................................................................................................... 6 2.1 General Description of EUT .................................................................................................................. 6 2.2 Description of Test Modes ..................................................................................................................... 7 2.2.1 Test Mode Applicability and Tested Channel Detail .................................................................... 8 2.3 Description of Support Units ................................................................................................................. 9 2.3.1 Configuration of System under Test ........................................................................................... 9 2.4 General Description of Applied Standards .......................................................................................... 10 3 Test Types and Results ............................................................................................................................. 11 3.1 Radiated Emission and Bandedge Measurement ............................................................................... 11 3.1.1 Limits of Radiated Emission and Bandedge Measurement ...................................................... 11 3.1.2 Test Instruments ....................................................................................................................... 12 3.1.3 Test Procedures ........................................................................................................................ 13 3.1.4 Deviation from Test Standard ................................................................................................... 13 3.1.5 Test Setup ................................................................................................................................. 14 3.1.6 EUT Operating Conditions ........................................................................................................ 15 3.1.7 Test Results ........…

Text truncated - open the document above for the full version.

Test Setup Photos

Hwa-Hsing(Dongguan)Testing Co.,Ltd. No.101,BldN1,Yuyuan2Rd,YuyuanIndustrial Park,HuangJiangTown,Dongguan,China Tel:0769-83078199 Web.:www.hwa-hsing.com E-Mail:[email protected] Page 1 of 3 ReportNo.:201022KH17 RadioTestSetPhotos ConductedEmissions Hwa-Hsing(Dongguan)Testing Co.,Ltd. No.101,BldN1,Yuyuan2Rd,YuyuanIndustrial Park,HuangJiangTown,Dongguan,China Tel:0769-83078199 Web.:www.hwa-hsing.com E-Mail:[email protected] Page 2 of 3 ReportNo.:201022KH17 RF-Radiatedemissionbelow1GHz Hwa-Hsing(Dongguan)Testing Co.,Ltd. No.101,BldN1,Yuyuan2Rd,YuyuanIndustrial Park,HuangJiangTown,Dongguan,China Tel:0769-83078199 Web.:www.hwa-hsing.com E-Mail:[email protected] Page 3 of 3 ReportNo.:201022KH17 RF-Radiatedemission>1GHz

Contact Information

Applicant

Rita Chang(Director)
[email protected]+886-2-26587878Fax: +886-2-26562997

Test Firm

Hwa-Hsing (Dongguan) Testing Co., Ltd.David Chen
[email protected]0769-83078199

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz3.03 mW
Confidentiality
Long Term
Grant Notes
RF output power is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Zylux Acoustic Corporation

XN6-SL514MW1006

5.1.4 Soundbar System

Jan 28, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2.1 Soundbar System - FCC ID XN6-SV210D0806 - Zylux Acoustic Corporation
XN6-SV210D0806

2.1 Soundbar System

Apr 01, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
30-Inch Sound Bar 5.1 System - FCC ID XN6-V514XK6 - Zylux Acoustic Corporation
XN6-V514XK6

30-Inch Sound Bar 5.1 System

Jul 17, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
30-Inch Sound Bar 2.0 System - FCC ID XN6-V20XK6 - Zylux Acoustic Corporation
XN6-V20XK6

30-Inch Sound Bar 2.0 System

Jun 07, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
XN6-M215AJ6

36-Inch Sound Bar 2.1 System

Jul 07, 2021

Equipment Class

DTS - Digital Transmission System