Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 23, 2011
Application Purpose
Original Equipment
Date of Application
Mar 23, 2011
Equipment Note
HD wireless video transmitter
Frequency Range
5750.00000000 - 5825.00000000
Company
Shenzhen Crystal Video Technology Co.,LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

Neutron Engineering Inc. Project No.: 1102C069 Page 2 of 13 1102C069 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 2 of 13 1102C069 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 3 of 13 1102C069 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 3 of 13 1102C069 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 4 of 13 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 5 of 13 1102C069 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 5 of 13 1102C069 1102C069

ID Label/Location Info

FCC ID:Y3HCB880120110222 20mm 9mm 2:1 Shen Zhen Crystal Video TechnologyCo.’Ltd FCC ID:Y3HCB880120110222 Shen Zhen Crystal Video TechnologyCo.’Ltd FCC ID:Y3HCB880120110222 Shen Zhen Crystal Video TechnologyCo.’Ltd

Internal Photos

Neutron Engineering Inc. Project No.: 1102C069 Page 6 of 13 1102C069 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 6 of 13 1102C069 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 7 of 13 1102C069 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 7 of 13 1102C069 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 8 of 13 1102C069 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 8 of 13 1102C069 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 9 of 13 1102C069 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 9 of 13 1102C069 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 10 of 13 1102C069 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 10 of 13 1102C069 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 11 of 13 1102C069 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 11 of 13 1102C069 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 12 of 13 1102C069 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 12 of 13 1102C069 1102C069 Neutron Engineering Inc. Project No.: 1102C069 Page 13 of 13 1102C069

RF Exposure Info

Neutron Engineering Inc. FCC RF EXPOSURE REPORT FCC ID: Y3HCB880120110222 Project No. : 1102C069 Equipment : HD wireless video transmitter Model : CB8801;CV8801;8801/6620;8801/5801 Applicant : Shenzhen Crystal Video Technology Co., LTD Address : F13, F518 Idea Land, Baoyuan Roda, Baoan Central Area, Shenzhen, China According: : FCC Guidelines for Human Exposure IEEE C95.1 Neutron Engineering Inc. No.3, Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China. TEL : (0769) 8318-3000 FAX : (0769) 8319-6000 Neutron Engineering Inc. GENERAL CONCULUSION: No evaluation required if power is below this threshold: F(GHz) P(mW) Low 5750 High 5825 10.37 Maximum measured transmitter power: Average Output Power (dBm) Average Output Power (mW) Conducted Power4.92 3.1046 EIRP Power 6.92 4.9204 Note: Table for Filed Antenna Ant. Brand Model Name Antenna TypeConnector Gain (dBi) 1 Jiaxing Jiali LA5220P5510-A1 5 Multi-layer Ceramics N/A 2.0 Threshold for no SAR evaluation is 10.37mW. Transmitter power is 3.1046 mW. Conclusion: No SAR evaluation required since transmitter power is below FCC threshold

Test Report

Neutron Engineering Inc. Report No.: NEI-FCCP-1-1102C069 Page 2 of 54 Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of CHINA, or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutron shall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Neutron Engineering Inc. Report No.: NEI-FCCP-1-1102C069 Page 3 of 54 Table of Contents Page 1 . CERTIFICATION 5 2 . SUMMARY OF TEST RESULTS 6 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3 . GENERAL INFORMATION 8 3.1 GENERAL DESCRIPTION OF EUT 8 3.2 DESCRIPTION OF TEST MODES 10 3.3 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING 10 3.4 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 3.5 DESCRIPTION OF SUPPORT UNITS 12 4 . EMC EMISSION TEST 13 4.1 CONDUCTED EMISSION MEASUREMENT 13 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 13 4.1.2 MEASUREMENT INSTRUMENTS LIST AND SETTING 13 4.1.3 TEST PROCEDURE 14 4.1.4 DEVIATION FROM TEST STANDARD 14 4.1.5 TEST SETUP 14 4.1.6 EUT OPERATING CONDITIONS 14 4.1.7 TEST RESULTS 15 4.2 RADIATED EMISSION MEASUREMENT 17 4.2.1 RADIATED EMISSION LIMITS 17 4.2.2 MEASUREMENT INSTRUMENTS LIST ANS SETTING 18 4.2.3 TEST PROCEDURE 19 4.2.4 DEVIATION FROM TEST STANDARD 19 4.2.5 TEST SETUP 20 4.2.6 EUT OPERATING CONDITIONS 20 4.2.7 TEST RESULTS (BETWEEN 30 – 1000 MHZ) 21 4.2.8 TEST RESULTS (ABOVE 1000 MHZ) 23 5 . BANDWIDTH TEST 35 5.1 APPLIED PROCEDURES / LIMIT 35 5.1.1 MEASUREMENT INSTRUMENTS LIST 35 5.1.2 TEST PROCEDURE 35 5.1.3 DEVIATION FROM STANDARD 35 5.1.4 TEST SETUP 35 5.1.5 EUT OPERATION CONDITIONS 35 5.1.6 TEST RESULTS 36 Neutron Engineering Inc. Report No.: NEI-FCCP-1-1102C069 Page 4 of 54 Table of Contents Page 6 . PEAK OUTPUT POWER TEST 38 6.1 APPLIED PROCEDURES / LIMIT 38 6.1.1 MEASUREMENT INSTRUMENTS LIST 38 6.1.2 TEST PROCEDURE 38 6.1.3 DEVIATION FROM STANDARD 38 6.1.4 TEST SETUP 38 6.1.5 EUT OPERATION CONDITIONS 38 6.1.6 TEST RESULTS 39 7 . ANTENNA CONDUCTED SPURIOUS EMISSION 41 7.1 APPLIED PROCEDURES / LIMIT 41 7.1.1 MEASUREMENT INSTRUMENTS LIST 41 7.1.2 TEST PROCEDURE 41 7.1.3 DEVIATION FROM STANDARD 41 7.1.4 TEST SETUP 41 7.1.5 EUT OPERATION CONDITIONS 41 7.1.6 TEST RESULTS 42 8 . POWER SPECTRAL DENSITY TEST 47 8.1 APPLIED PROCEDURES / LIMIT 47 8.1.1 MEASUREMENT INSTRUMENTS LIST 47 8.1.2 TEST PROCEDURE 47 8.1.3 DEVIATION FROM STANDARD 47 8.1.4 TEST SETUP 47 8.1.5 EUT OPERATION CONDITIONS 47 8.1.6 TEST RESULTS 48 9 . RF EXPOSURE TEST 52 10 . EUT TEST PHOTO 53 Neutron Engineering Inc. Report No.: NEI-FCCP-1-1102C069 Page 5 of 54 1. CERTIFICATION E q u i p m e n t : HD wireless video transmitter Brand Name : N/A Model Name : CB8801; CV8801; 8801/6620; 8801/5801 A p p l i c a n t : Shenzhen Crystal Video Technology Co.,LTD Date of Test : Feb. 22, 2011 ~ Mar. 06, 2011 T e s t I t e m : ENGINEERING SAMPLE Standards : FCC Part15, Subpart C(15.247) / ANSI C63.4 : 2003 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FCCP-1-1102C069) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality assessment standard and technical standard(s). Neutron Engineering Inc. Report No.: NEI-FCCP-1-1102C069 Page 6 of 54 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.247) , Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS 15.247(d) Antenna conducted Spurious EmissionPASS 15.247(a)(2) 6dB Bandwidth PASS 15.247(b)(3) Peak Output Power PASS 15.209/15.205 Radiated Spurious Emission PASS 15.247(e) Power Spectral Density PASS 15.203 Antenna Requirement PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Neutron Engineering Inc. Report No.: NEI-FCCP-1-1102C069 Page 7 of 54 2.1 TEST FACILITY The test facilities used to collect the test data in this report is DG-CB03/DG-C02 at the location of No.3,Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China.523792 Neutron's test firm number is 319330 2.2 MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2: The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 A. Conducted Measurement : Test Site Method Measurement Frequency Range U,(dB) NOTE DG-C02 CISPR 150 KHz ~ 30MHz 1.94 B. Radiated Measurement : Test Site Method Measurement Frequency Ra…

Text truncated - open the document above for the full version.

Test Setup Photos

Neutron Engineering Inc. Report No.: NEI-FCCP-1-1102C069 Page 54 of 55 10. EUT TEST PHOTO Conducted Measurement Photos Neutron Engineering Inc. Report No.: NEI-FCCP-1-1102C069 Page 54 of 55 10. EUT TEST PHOTO Conducted Measurement Photos Neutron Engineering Inc. Report No.: NEI-FCCP-1-1102C069 Page 55 of 55 Radiated Measurement Photos Neutron Engineering Inc. Report No.: NEI-FCCP-1-1102C069 Page 55 of 55 Radiated Measurement Photos

Contact Information

Applicant

Zhang Zude(Majordomo)
[email protected]86-755-26716030Fax: 86-755-23496331

Technical Contact

Neutron Engineering, Inc.Steven Lu
[email protected]+86-769-83183000

No.3,Jinshagang 1st Rd, ShiXia,Dalang · Dongguan City · China

Non-Technical Contact

Neutron Engineering, Inc.Cathy Wang
[email protected]+86-769-83183000

Test Firm

BTL Inc.Daisy Dai
[email protected]008676983183000Fax: 0086 769 83196000

Technical Specifications

#Rule PartsFrequency RangePower Output
115C5.75 GHz - 5.83 GHz29.00 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted (peak). This is a portable device. End-users must be provided with specific operating conditions for satisfying RF exposure compliance.

Other Applications from Shenzhen Crystal Video Technology Co.,LTD.

AURORA - FCC ID Y3H712031202022 - Shenzhen Crystal Video Technology Co.,LTD.
Y3H712031202022

AURORA

Aug 28, 2022

Equipment Class

NII - Unlicensed National Information Infrastructure TX
wireless video transmitter system - FCC ID Y3H710331032004 - Shenzhen Crystal Video Technology Co.,LTD.
Y3H710331032004

wireless video transmitter system

May 18, 2020

Equipment Class

NII - Unlicensed National Information Infrastructure TX
HD wireless video transmitter - FCC ID Y3HCC898020150202 - Shenzhen Crystal Video Technology Co.,LTD.
Y3HCC898020150202

HD wireless video transmitter

Feb 15, 2015

Equipment Class

NII - Unlicensed National Information Infrastructure TX
HD Wireless Video Transmission System - FCC ID Y3HCH731020141102 - Shenzhen Crystal Video Technology Co.,LTD.
Y3HCH731020141102

HD Wireless Video Transmission System

Dec 28, 2014

Equipment Class

NII - Unlicensed National Information Infrastructure TX
HD Wireless Video Transmission System - FCC ID Y3HCH797020141101 - Shenzhen Crystal Video Technology Co.,LTD.
Y3HCH797020141101

HD Wireless Video Transmission System

Dec 28, 2014

Equipment Class

NII - Unlicensed National Information Infrastructure TX