Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
D-302924 1 Evolve Ceiling Sensor Wireless Z-Wave Digital Ceiling Mount PIR detector Installation Instructions 1. INTRODUCTION The Evolve Ceiling Sensor is the smallest 360 ceiling mounted passive infrared detector presently marketed. The Evolve Ceiling Sensor is a microprocessor-controlled wireless digital PIR detector, designed for easy installation. The Evolve Ceiling Sensor provides a nearly conical pattern of maximum 10.5 m (36 ft) diameter, when installed on a 3.6 m (12ft) ceiling. The advanced True Motion Recognition algorithm (patented) allows it to distinguish between the true motion of an intruder and any other disturbances which may cause false alarms. False alarms caused by environmental disturbances are virtually eliminated with alternate polarity pulse counter signal processing and a low-noise pyroelectric detector. The Evolve Ceiling Sensor includes the following features: Provides multiple beams coverage. Incorporates a Z-Wave transmitter. Sophisticated frequency domain digital signal processing. Programmable motion event counter. Very low current consumption Tamper switch for detector opening. White light protection. Elegantly styled, sturdy case. Figure 1 – External View 2. SPECIFICATIONS Detector Type: Dual element low-noise pyroelectric sensor. ELECTRICAL Internal Battery: 3V Lithium battery, type CR-123A. For UL installations, use Panasonic, Sanyo or GP only. Nominal Battery Capacity: 1400 mA/h. Battery Life (with LED on): Typically over 3 years. Battery Power Test: Performed immediately upon battery insertion and periodically after every several hours. FUNCTIONAL True Motion Event Verification: 2 position selector - 1 (OFF) or 2 (ON) motion events. Visual Indications: LED Lights for about 3 seconds upon transmission of alarm & tamper messages and upon motion detection in the walk test mode. LED Flashes during the power-up stabilization period, or after restoring (pressing) the tamper switch. LED does not light upon transmission of supervision messages. Rearm Timer: Rearms the detector 2 minutes after the last motion detection. The detector reverts to the initial state if there is no movement during 2 minutes. The timer is disabled in the walk test mode. WIRELESS Frequency (MHz): 908. Transmission Sequence: 3 data bursts at variable / random intervals within 3 seconds. Encoding: Over 16 million possible combinations. MOUNTING Ceiling Mounting: Maximum mounting height 3.6 m (12 ft) ENVIRONMENTAL RFI Protection: >10 V/m up to 2000 MHz. Operating Temperatures: -10°C to 50°C (14°F to 122°F). Storage Temperatures: -20°C to 60°C (-4°F to 140°F). Compliance with Standards: USA @ 908 MHz: complies with CFR 47 part 15 (FCC) and RSS210. PHYSICAL Dimensions (diam. x H) : 86 x 24 mm (3-3/8 x 15/16 in). Weight: 64 grams (2 oz) Color: White. PATENTS U.S. Patents 5,693,943 6,818,881 (other patents pending). Figure 2 - Evolve Ceiling Sensor PIR Coverage Pattern 2 D-302924 3. INSTALLATION 3.1 Mounting The Evolve Ceiling Sensor PIR is installed on the ceiling. The maximum installation height is 3.6m (12 ft). A. Mount the unit so that the expected motion of an intruder is perpendicular to the detector and not in the direction of the detector. Be sure to install the detector on a stable ceiling, to avoid vibrations. Note: Passive infrared detectors are sensitive to changes in infrared energy caused by an object moving across the unit's field of view. Detection of changes in infrared energy depends on the amount of infrared energy transmitted by the moving object, and the temperature difference between the object and the background. Because of this the PIR may fail to respond under certain temperature and background conditions, in which the temperature difference is too small. B. The Evolve Ceiling Sensor is extremely immune to air turbulence and RFl interference. However, to minimize possible false alarms, it is highly recommended that you avoid aiming the detector at heaters, sources of light, or windows subjected to direct sunlight. Avoid mounting the Evolve Ceiling Sensor in locations where air drafts could flow from the ceiling or from close walls. Also avoid installation close to high power electrical cables. Figure 3 - Removing the Cover C. Hold the unit base as shown in Figure 3. Rotate the cover counter clockwise until it stops. Separate the cover from the base. Note: If the cover does not separate easily from the base, insert a 1/8" screwdriver between a tab (on the cover) and a slot (on the base). Lower the screwdriver handle until the base separates from the cover and removes easily. D. Mount the base (equipped with the printed circuit board) in the location selected for optimum coverage. Using the two mounting holes at the back of the base fasten the unit firmly to the mounting surface to avoid possible vibrations. (Figure 4). Line up the 3 tabs on the cover with the 3 slots on the base. Fit the cover over the base. Rotate the cover clockwise until it stops. Figure 4 – Installing the Cover 3.2 LED Functions After battery insertion and rear cover closure, the LED flashes for 2 minutes approximately until the detector stabilizes. After stabilization, the detector enters automatically walk-test period of 15 minutes (see section 3.6 Walk Test below). In this mode the LED lights and the unit sends an RF alarm signal on every detection (regardless of LED jumper position). After the walk-test period, the LED operates according to the LED jumper setting, as follows: LED Jumper Position LED Activity in "Normal Mode" ON LED lights during alarm transmission. OFF LED does not light during alarm transmission. After the first 15 minutes, following every motion detection and alert transmission, the detector disarms itself to save battery power. It rearms (reverts to the ready state) if there is no subsequent detection during the following 2-minute period. Therefore, if you want to check the detector, you have to exit the room for at least 2 minutes and then enter the roo…
Text truncated - open the document above for the full version.
External Photos
Internal Photos
BUREAU VERITAS TESTREPORTNo.: (5212)153-1455 To:EVOLVEGUESTCONTROLS,INC. TESTREPORT To: 85 DentonAve. New HydePark,NY 11040 Attn: Address: E-mail: Fax: Attn: DavidKorcz Fax: MEW-12MY430ETHS-8-A Address: E-mail: FolderNo.: Factoryname: Location: WirelessCeilingMountPIR detector ModelNo.: PIR-100 Product: SampleNo: HK120528/013 Test Date(s): July 18,2012 Test Requested:FCC Part 15 - 2011 Test Method: ANSIC63.4- 2009 FCC10: Y3K-PIR-100 The resultsgivenin this reportare relatedto the testedspecimenof the describedelectricalapparatus. CONCLUSION:The submittedsamplewas foundto COMPLYwith requirementof FCC Part 15 SubpartC. AuthorizedSignature: BUREAUVERITASHONGKONGLlMITED- KowloonBay Office 1/FPacificTradeCentre, 2 Kai HingRoad,KowloonBay, Kowloon,HONGKONG Tel:+85223310888 Fax: +85223310889 www.cps.bureauveritas.com Thisreportis intendedfor yourexclusiveuse.Anycopyingor replicationof thisreponto or for anyotherpersonor entity,or use of ournameOftrademark,is permittedonlywithourpriorwrittenpermission.Ourreportis limitedto thetestsamplesidentified herem.Theresultsset forthinthisreportarenotnecessarilyindicativeorrepresentativeof thestatisticalqualityor characteristicsof thelot fromwhicha lestsamplewastakenor anysimilaror identicalproductunlessspecificallyandexpresslynoted.Ourreport Includesall of thetestsrequestedbyyouandtheresultsthereofYoushallhavethirtydaysfromreceiptof thisreportto request additionaltestingof thesamplesor to notifyus of anyerrorsor omissionsrelatingto ourreport,provided.however,suchnotice shallbe in writingandshallspecificallyaddresstheissueyouwishto raise.A failureto raisesuchissuewithintheprescribedume shallconstituteyourunqualifiedacceptanceof thecompletenessof thisreport.thetestsconductedandthecorrectnessof thereport contents. Page1 of 17 TEST REPORT No.: (5212)153-1455 BUREAU VERITAS HONG KONG LIMITED – Kowloon Bay Office 1/F Pacific Trade Centre, 2 Kai Hing Road, Kowloon Bay, Kowloon,HONG KONG Tel: +852 2331 0888 Fax: +852 2331 0889 www.cps.bureauveritas.com This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Page 2 of 17 Test Result Summary EMISSION TEST Test requirement: FCC Part 15 - 2011 Test Condition Test Method Test Result Pass Failed Radiated Emission Test, 9kHz to 40GHz ANSI C63.4 Report Revision & Sample Re-submit History: -- TEST REPORT No.: (5212)153-1455 BUREAU VERITAS HONG KONG LIMITED – Kowloon Bay Office 1/F Pacific Trade Centre, 2 Kai Hing Road, Kowloon Bay, Kowloon,HONG KONG Tel: +852 2331 0888 Fax: +852 2331 0889 www.cps.bureauveritas.com This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Page 3 of 17 Test Laboratory & Test Instruments List Radiated and Conducted emissions measurements are investigated and taken pursuant to the procedures of ANSI C63.4 – 2009. An Open Area Test Site and Full Anechoic Chamber (FCC Listed Site, Registration No. 642151) are set up for investigation and located at : BUREAU VERITAS HONG KONG LIMITED, EMC CENTRE No. 2106-2107, 21/F., Westin Centre, 26 Hung To Road, Kwun Tong, Kowloon, Hong Kong Test Instrument List Radiated Emission EQUIPMENT MANUFACTURER MODEL NO. SERIAL NO. CALIBRATION DUE EMI TEST RECEIVER R&S ESCI 100379 18-OCT-2012 LOOP ANTENNA ETS-LINDGREN 6502 00102266 07-AUG-2012 BILOG ANTENNA SCHAFFNER CBL6112D 25229 16-SEP-2012 HORN ANTENNA SCHWARZBECK BBHA9120D 9120D-692 16-SEP-2012 PREAMPLIFIER SCHWARZBECK BBV9718 9718-152 16-SEP-2012 OPEN AREA TEST SITE BVCPS N/A N/A 10-JUL-2013 ANECHOIC CHAMBER ALBATROSS M-CDC 80374004499B 01-DEC-2012 COAXIAL CABLE SUHNER N/A N/A 06-OCT-2012 Remarks: - N/A: Not Applicable or Not Available The measurement instrumentation uncertainty would be taking into consideration on each of the test result TEST REPORT No.: (5212)153-1455 BUREAU VERITAS HONG KONG LIMITED – Kowloon Bay Office 1/F Pacific Trade Centre, 2 Kai Hing Road, Kowloon Bay, Kowloon,HONG KONG Tel: +852 2331 0888 Fax: +852 2331 0889 www.cps.bureauveritas.com This report is intended for…
Text truncated - open the document above for the full version.
Test Set Up Photo
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 908.39 MHz - 908.39 MHz | - |

908 MHz Transceiver
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
2.4GHz ZigBee router for connecting 3 USNAP devices
Equipment Class
DTS - Digital Transmission System
908.4MHz Z-Wave Module in a USNAP form factor
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter