Y85FCT-2400MRF fuel control terminal

E.J. Ward, Inc.
RF fuel control terminal - FCC ID Y85FCT-2400M - E.J. Ward, Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 08, 2011
Application Purpose
Original Equipment
Date of Application
May 08, 2011
Equipment Note
RF fuel control terminal
Frequency Range
2410.00000000 - 2410.00000000
Company
E.J. Ward, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—

External Photos

β†—
β†—

ID Label/Location Info

β†—
β†—
β†—

Internal Photos

β†—
β†—

Test Report

β†—

Test Setup Photos

β†—
β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

E. J. WARD INC. Fuel Control Terminal Service Guide Advanced Technology with Proven Performance 7/28/2010 1-1 NOTICE The following terms are used throughout this service guide to call attention to the presence of hazards of various risk levels, or to other important information concerning the product: DANGER indicates the presence of a hazard which will cause death, severe personal injury, or substantial property damage if ignored. WARNING indicates the presence of a hazard which can cause death, severe personal injury, or substantial property damage if ignored. CAUTION indicates the presence of a hazard which will or can cause minor personal injury or substantial property damage if ignored. NOTICE indicates special instructions not related to personal injury hazards. It is important that this service guide be thoroughly read and understood before attempting any service on the FUEL CONTROL TERMINAL (FCT). THESE TERMS ARE IMPORTANT AND ARE TO BE TAKEN SERIOUSLY - READ THEM! FAILURE TO FOLLOW THESE GUIDELINES CAN RESULT IN DEATH, SEVERE PERSONAL INJURY, OR SUBSTANTIAL PROPERTY DAMAGE! 1-3 IMPORTANT This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation. NOTE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at owner’s own expense. DANGER Hazardous voltages are present inside the FCT cabinet. Remove all power before servicing! WARNING Consult this service manual before attempting any service procedures on the FCT. Any servicing of the FCT must be performed solely by personnel who are trained and qualified to do so. WARNING Take all necessary precautions when working around hazardous materials and in hazardous areas. Follow applicable electrical codes. Do not use electrically powered tools or equipment when in a hazardous location. If you are unsure of actions, consult local authorities. WARNING Failure to comply with all safety requirements can result in death, severe personal injury, or substantial property damage. NOTICE Specifications and/or installation instructions are subject to change. 1-4 Table of Contents 1. INTRODUCTION .................................................................................................................................6 2. FUEL CONTROL TERMINAL WARRANTY..................................................................................7 3. FUEL SYSTEM OVERVIEW .............................................................................................................8 THE FUELING SYSTEM......................................................................................................................................8 3.1 HOST COMPUTER.................................................................................................................................9 3.2 FUEL SITE.............................................................................................................................................9 3.3 ELECTRONIC ACCESS MEDIA.............................................................................................................10 3.4 COMMUNICATIONS.............................................................................................................................10 3.5 DOWNLOAD PARAMETERS.................................................................................................................11 3.6 FUELING PROCESS..............................................................................................................................12 3.7 FUELING AUTHORIZATION.................................................................................................................13 3.8 PUMP LOGIC.......................................................................................................................................14 3.9 THE FUEL CONTROL TERMINAL.........................................................................................................16 4. FCT POWER REQUIREMENTS .....................................................................................................19 4.1 FCT POWER SPECIFICATION - 120VAC .............................................................................................19 4.2 GROUND.............................................................................................................................................19 4.3 AC VOLTAGE CHECK PROCEDURE.....................................................................................................21 4.4 DC VOLTAGE CHECK PROCEDURE.....................................................................................................22 4.5 POWER SUPPLY TROUBLESHOOTING..................................................................................................23 5. FCT START-UP ..................................................................................................................................24 5.1 START-UP MESSAGES ON FCT’S WITHOUT AN OPERATING SYSTEM ...........................................24 5.2 DOWNLOADING AN OPERATING SYSTEM .....................................................................................26 6. CARD TYPES.............................................................................................................…

Text truncated - open the document above for the full version.

ID Label/Location Info

Please review and make any necessary changes! Note: The colors shown are for visualization purposes only and are not intended as a color match on the finished parts. 091060 MAKE CHANGES: ANOTHER PROOF REQUIRED NO FURTHER PROOF REQUIRED MAKE CHANGES INDICATED: SIGNATURE REQUIREDDATE PROOF APPROVED SIGNATURE REQUIREDDATE YOUR APPROVAL INDICATES COMPLETE ACCEPTANCE OF THE JOB BEING PROOFED. PROOF Background: reflex blue Copy: silver material SCALE: 100% revised 7-12-10 070083.pdf FORM 663 R 11/16/05 070083revA 070083revA 6.000" R 0.187" 2.000" 0.188"5.625" 1.625" 0.188" Ø 0.170" TM POWER REQUIREMENTS: 120V/240V AC, 60 H z, 3A OR 12V DC, 3A 2.500" TM POWER REQUIREMENTS: 120V/240V AC, 60 H z, 3A OR 12V DC, 3A

Test Report

EMC Report for EJ Ward on the model: RT Automated Fuel Control Terminal File: 100086465DAL-001 Page 1 of 25 TEST REPORT Report Number: 100086465DAL-001 Project Number: G100086465 Testing performed on the RT Automated Fuel Control Terminal (2.41GHz) FCC ID: to 47 CFR Part 15. 247:2008 For EJ Ward Test Performed by: Test Authorized by: Intertek 1809 10th Street Suite 400 Plano, TX 75035 EJ Ward 8801 Tradeway St San Antonio, TX 78217 Prepared by: Date: June 10, 2010 William Cullen, Assoc EMC Engineer Reviewed by: Date: June 10, 2010 Jeremy Pickens, EMC Lab Manager This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. This report must not be used to claim product endorsement by A2LA, NIST nor any other agency of the U.S. Government. EMC Report for EJ Ward on the model: RT Automated Fuel Control Terminal File: 100086465DAL-001 Page 2 of 25 Report No. 100086465DAL-001 Equipment Under Test: RT Automated Fuel Control Terminal Trade Name: Automated Fuel Control Terminal Model No.: RT FCC ID: Applicant: EJ Ward Contact: Mr. Eric Scrivner Address: 8801 Tradeway St San Antonio, TX 78217 Country USA Tel. Number: 210-824-7383 Fax number: --- Applicable Regulation: FCC Part 15, Subpart C Section 15.247 Test Site Location: Intertek 1809 10 th Street Plano, TX 75035 Date of Test: April 12 to May 28, 2010 We attest to the accuracy of this report: William Cullen Assoc EMC Engineer Jeremy Pickens EMC Lab Manager EMC Report for EJ Ward on the model: RT Automated Fuel Control Terminal File: 100086465DAL-001 Page 3 of 25 Table of Contents 1.0 Introduction.................................................................................................................................. 4 1.1 Summary of Tests............................................................................................................ 4 2.0 General Description.................................................................................................................... 5 2.1 Product Description.......................................................................................................... 5 2.2 Related Submittal(s) Grants........................................................................................... 5 2.3 Test Methodology............................................................................................................. 6 2.4 Test Facility....................................................................................................................... 6 3.0 System Test Configuration....................................................................................................... 7 3.1 Support Equipment.......................................................................................................... 7 3.2 Block Diagram of Test Setup.......................................................................................... 7 3.3 Justification........................................................................................................................ 9 3.4 Software Exercise Program............................................................................................ 9 3.5 Mode of Operation During Test...................................................................................... 9 3.6 Modifications Required for Compliance........................................................................ 9 4.0 Measurement Results.............................................................................................................. 10 4.1 6-dB Bandwidth.............................................................................................................. 10 4.2 Occupied Bandwidth......................................................................................................12 4.3 Conducted Output Power.............................................................................................. 14 4.4 Power Spectral Density................................................................................................. 15 4.5 Out of Band Emissions.................................................................................................. 17 4.6 Restricted Bands............................................................................................................ 19 4.8 AC Line Conducted Emission....................................................................................... 23 5.0 List of test equipment.............................................................................................................. 24 6.0 Document History........................................................................................................................ 25 EMC Report for EJ Ward on the model: RT Automated Fuel Control Terminal File: 100086465DAL-001 Page 4 of 25 1.0 Introduction The Equipment under Test (EUT) is a transceiver operating at 2.41GHz This report is designed to show compliance of the 2.41GHz transceiver with FCC Part 15.247 requirements. 1.1 Summary of Tests TEST REFERENCE FCC 17.247 RESULTS 6-dB Bandwidth 15.247(a)(2) Complies 20-dB Bandwidth 15.215(c) Complies Peak Conducted Output Power (< 1W) 15.24…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Paul Witt(Engineering Director)
[email protected]210.824.7383Fax: 210.824.2031

Technical Contact

EJ Ward, IncPaul Witt
[email protected]210-824-7381

8801 Tradeway Β· San Antonio, Texas Β· United States

Non-Technical Contact

EJ Ward, IncEric Scrivner
[email protected]210-824-7383

Test Firm

Intertek Testing Services NA, Inc.Paul Coghill
[email protected]330-405-3552Fax: 972 238 1860

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.41 GHz4.00 mW
Confidentiality
Long Term

Other Applications from E.J. Ward, Inc.

RF fuel control terminal - FCC ID Y85FCT-900M - E.J. Ward, Inc.
Y85FCT-900M

RF fuel control terminal

Jul 21, 2011

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
RF House Module - FCC ID Y85HM-900M - E.J. Ward, Inc.
Y85HM-900M

RF House Module

Apr 07, 2011

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
RF House Module - FCC ID Y85HM-2400M - E.J. Ward, Inc.
Y85HM-2400M

RF House Module

Apr 07, 2011

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter