FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hytera Communications Corporation Limited/
  3. YAMMD65XU2

YAMMD65XU2Digital Mobile Radio

Hytera Communications Corporation Limited

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Dec 21, 2014
Application Purpose
Original Equipment
Date of Application
Dec 21, 2014
Equipment Note
Digital Mobile Radio
Frequency Range
450.00000000 - 527.00000000
Company
Hytera Communications Corporation Limited
Country
China

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—
β†—
β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—
β†—

Internal Photos

β†—

Test Report

β†—
β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

811MD65000010 L07157 Z07639 C10524   2013 Hytera Corp., Ltd . : !" #$%:&'(): - - :.. 9108 518057 400 830 7020 http //www hytera com 2014 *+,/01 OWNER'SMANUAL DIGITAL MOBILE RADIO 23456 Hytera Communications Corporation Limited. Hytera Communications Corporation Limited. Preface Thanks for your favor in our product. This manual is helpful for you to quickly know how to use the product. Please refer to the corresponding Feature Book for detailed features and operations. This manual is applicable to the following product: MD65X Digital Mobile Radio (X may represent 2, 5, 6 or 8) Instructional Icons : Indicates functions that are available on digital channel only. : Indicates functions that are available on analog channel only. Functions marked with neither the above icons are available on both analog and digital channels. Disclaimer Hytera Communications Corporation Limited (the Company) endeavors to achieve the accuracy and completeness of this manual, but no warranty of accuracy or reliability is given. All the specifications and designs are subject to change without notice due to continuous technology development. No part of this manual may be copied, modified, translated, or distributed in any manner without th e express written permission of us. We do not guarantee, for any particular purpose, the accuracy, validity, timeliness, legitimacy or completeness of the Third Party products and contents involved in this manual. If you have any suggestions or would like to learn more details, please visit our website at: http://www.hytera. com. RF Radiation Information This product must be restricted to operations in an occupational/controlled RF exposure environment. Users must be fully aware of the hazards of the exposure and able to exercise control over their RF exposure to qualify for the higher exposure limits. RF Radiation Profile Radio Frequency (RF) is a frequency of electromagnetic radiation in the range at which radio signals are transmitted. RF technology is widely used in communication, medicine, food processing and other fields. It may generate radiation during use. RF Radiation Safety In order to ensure user health, experts from relevant industries including science, engineering, medicine and health work with international organizations to develop standards for safe exposure to RF radiation. These standards consist of: ● United States Federal Communications Commission, Code of Federal Regulations; 47CFR part 2 sub-part J; ● American National Standards Institu te (ANSI)/ Institute of Electrical and Electronic Engineers (IEEE) C95. 1-1992; ● Institute of Electrical and Electronic Engineers (IEEE) C95.1-1999; ● International Commission on Non-Ionizing Radiation Protection (ICNIRP) 1998. FCC Regulations Federal Communication Commission (FCC) requires that all radio communication products should meet the requirements set forth in the above standards before they can be marketed in the U.S, and the manufacturer shall post a RF label on the product to inform users of operational instructions, so as to enhance their occupational health against exposure to RF energy. Operational Instructions and Training Guidelines To ensure optimal performance and compliance with the occupational/controlled environment RF energy exposure limits in the above standards and guidelines, users should transmit not more than 50% of the time and always adhere to the following procedures: ● Antenna gain must not exceed 5dBi. ● The antenna installation must comply with the requirements of manufacturer or supplier, and it must be 1. meter away from human body. EU Regulatory Conformance As certified by the qualified laboratory, the product is in compliance with the essential requirements and other relevant provisions of the Directive 1999/5/EC. Please note that the above information is applicable to EU countries only. 1 Contents Items in the Package ------------------------------------------------------------------- 2 Product Overview ----------------------------------------------------------------------- 3 Radio Unit -------------------------------------------------------------------------- 3 Remote Speaker Microphone ------------------------------------------------ 3 Installation------------------------------------------------- -------------------------------- 3 Instructions ------------------------------------------------------------------------ 3 Installation Tools ----------------------------------------------------------------- 3 Installation Procedure ---------------------------------------------------------- 3 Status Indication ------------------------------------------------------------------------ 4 LCD Icon -------------- -------------------------------------------------------------- 4 LED Indicator ---------------------------------------------------------------------- 4 Basic Operations ------------------------------------------------------------------------ 5 Powering On/Off ----------------------------------------------------------------- 5 Adjusting the Volume ----------------------------------------------------------- 5 Selecting a Zone ----------------------------------------------------------------- 5 Selecting a Channel ------------------------------------------------------------- 5 Setting TX Power Level -------------------------------------------------------- 5 Call Services ----------------------------------------------------------------------------- 5 Calls on Digital Channel ------------------------------------------------- 5 Calls on Analog Channel (No Signaling) ---------------------------- 5 Features ----------------------------------------------------------------------------------- 6 Troubleshooting ------------------------------------------------------------------------- 6 Care and Cleaning ---------------------------------------------------------------------- 7 Optional Accessories ------------------------------------------------------------------ 7 2 Items in…

Text truncated - open the document above for the full version.

Cover Letter(s)

Hytera Communications Co.,Ltd AUTHORIZATION LETTER DATE: 2014-12-05 To whom it may concern: We, < Hytera Communications Co.,Ltd >, the undersigned, hereby authorize < Shenzhen Huatongwei International Inspection Co., LTD.> to act as our authorized agent on our behalf in all manners relating to application for FCC equipment authorization, including signing of all documents relating to these matters. Any individual within this entity may act on our behalf. Any and all acts carried out by < Shenzhen Huatongwei International Inspection Co., LTD.> on our behalf shall have the same effect as acts of our own. This authorization is valid until further written notice from <Shenzhen Huatongwei International Inspection Co., LTD.>. Sincerely, (Name and Title) Xiong Lei Signature: 2014-12-05

Cover Letter(s)

Hytera Communications Co.,Ltd FO023_FCC Confidentiality Form FO023 –FCC CONFIDENTIALITY FORM Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: This letter is to comply with Sections 0.457 and 0.459 pertaining to confidential material. Hytera Communications Co.,Ltd would like the following documents regarding this submission for FCC ID: YAMMD65XU2to be kept confidential. 1. Operation Description.pdf. 2. Block Diagram .pdf 3. Schematic Diagram.pdf 4. BOM - Part List 5. Tune up Procedures The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want these documents to be accessible to the general public. Sincerely, Hytera Communications Co.,Ltd Xiong Lei Fax: +86-755-86137130 Tel: +86-755-26972999 E-mail:[email protected]

Cover Letter(s)

Justification Letter DATE: Dec. 19, 2014 Federal Communications Commission Authorization & Evaluation Division 7435 Oakland Mills Road Colombia, Maryland 21046 FCC ID: YAMMD65XU2 Model: MD650 U(2), MD652 U(2), MD655 U(2), MD656 U(2), MD658 U(2) Dear Sir/Madam, We , Hytera Communications Corporation Ltd. acknowledge that this device will not be marketed to USA users with the frequency band which is not allowed by rule part 90.and it is a violation of FCC rules if this device is operated on unauthorised frequencies inside the U.S.A. We , Hytera Communications Corporation Ltd. acknowledge this equipment meets the requirements of FCC Rules, Parts 90.203 (e) and (g) as applicable. Programming of this product's transmit frequencies can be performed ONLY by the manufacturer or by service or maintenance personnel. The operator cannot program transmit frequencies using the equipment's external operation. Sincerely yours, Hytera Communications Corporation Ltd. Xiong Lei/ Director of management dept Fax: +86 755 8613 7130 Tel: +86 755 2697 2999 E-mail:[email protected]

Cover Letter(s)

Hytera Communications Corporation Ltd. Add: HYT Tower, Hi-Tech Industrial Park North, Nanshan District, Shenzhen China. 518057 Tel:+86-0755-26972999 Fax:+86-755-86137130 Product Similarity Declaration To Whom It May Concern, We, Hytera Communications Corporation Ltd. , hereby declare that our Digital Mobile Radio, Model Number: MD650 U(2)is the same with MD652 U(2),MD655 U(2), MD656 U(2), MD658 U(2) which was tested by SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO. LTD. They are just different in model number due to market purposes. Please contact me if you have any question. Signature: Lei Xiong General Director 2014-11-11

External Photos

Report No : TRE1411001801 Page 92 of 97 6. External and Internal Photos of the EUT External photos of the EUT Report No : TRE1411001801 Page 93 of 97 Report No : TRE1411001801 Page 94 of 97

ID Label/Location Info

Lable Location

ID Label/Location Info

6927404370536 *12912A3039* 0678 FCC ID:YAMMD65XU2 MD650 U(2) 450-527MHz DC 13.6V---8A MD650-000G00P0-000000-U2-A-C A7.00.01.001 6927404370536 *12912A3039* FCC ID:YAMMD65XU2 MD652 U(2) 450-527MHz DC 13.6V---8A MD650-000G00P0-000000-U2-A-C A7.00.01.001 6927404370536 *12912A3039* FCC ID:YAMMD65XU2 MD655 U(2) 450-527MHz DC 13.6V---8A MD650-000G00P0-000000-U2-A-C A7.00.01.001 6927404370536 *12912A3039* FCC ID:YAMMD65XU2 MD656 U(2) 450-527MHz DC 13.6V---8A MD650-000G00P0-000000-U2-A-C A7.00.01.001 6927404370536 *12912A3039* FCC ID:YAMMD65XU2 MD658 U(2) 450-527MHz DC 13.6V---8A MD650-000G00P0-000000-U2-A-C A7.00.01.001 0678 0678 0678 0678

Internal Photos

Report No : TRE1411001801 Page 95 of 97 Internal photos of the EUT Report No : TRE1411001801 Page 96 of 97 Report No : TRE1411001801 Page 97 of 97 .....................End of Report.........................

Test Report

The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. TEST REPORT Report Reference No. .................... : TRE1411001801 R/C..........: 43921 FCC ID ............................................. : YAMMD65XU2 Applicant’s name ........................... : Hytera Communications Co.,Ltd Address ............................................. : HYT Tower, Hi-Tech Industrial Park North, Nanshan District, Shenzhen China Manufacturer......................................: Hytera Communications Co.,Ltd Address...............................................: HYT Tower,Hi-Tech Industrial Park North, Nanshan District, Shenzhen China Test item description .................... : Digital Mobile Radio Trade Mark ....................................... : Hytera Model/Type reference ....................... : MD650 U(2) Listed Model(s) ................................. : MD652 U(2), MD655 U(2), MD656 U(2), MD658 U(2) Standard ......................................... : FCC Part 90/FCC Part 2/ FCC Part 15B Date of receipt of test sample...........: Nov 13, 2014 Date of testing..............................: Nov 13, 2014- Nov 27, 2014 Date of issue.................................: Nov 27, 2014 Result .................. ........................: PASS Compiled by ( position+printed name+signature) .. : File administrators Yingchun Shan Supervised by ( position+printed name+signature) .. : Project Engineer Cary Luo Approved by ( position+printed name+signature) .. : RF Manager Hans Hu Testing Laboratory Name ............. : Shenzhen Huatongwei International Inspection Co., Ltd Address ............................................. : Keji Nan No.12 Road, Hi-tech Park, Shenzhen, China Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Huatongwei International Inspection Co., Ltd is acknowledged as copyright owner and source of the material. Shenzhen Huatongwei International Inspection Co., Ltd takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Report No : TRE1411001801 Page 2 of 87 Contents 1. TEST STANDARDS AND TEST DESCRIPTION 3 1.1. Test Standards 3 1.2. Test Description 3 2. SUMMARY 4 2.1. Client Information 4 2.2. Product Description 4 2.3. EUT operation mode 5 2.4. EUT configuration 5 2.5. Related Submittal(s) / Grant (s) 5 2.6. Modifications 5 3. TEST ENVIRONMENT 6 3.1. Address of the test laboratory 6 3.2. Test Facility 6 3.3. Environmental conditions 7 3.4. Statement of the measurement uncertainty 7 3.5. Equipments Used during the Test 8 4. TEST CONDITIONS AND RESULTS 10 4.1. Conducted Emissions Test 10 4.2. Maximum Transmitter Power 19 4.3. Occupied Bandwidth and Emission Mask Test 26 4.4. Modulation Charcateristics 35 4.5. Frequency Stability Test 40 4.6. Transmitter Frequency Behavior 43 4.7. Spurious Emssion on Antenna Port 47 4.8. Transmitter Radiated Spurious Emssion 58 4.9. Receiver Radiated Spurious Emssion 70 5. TEST SETUP PHOTOS OF THE EUT 80 6. EXTERNAL AND INTERNAL PHOTOS OF THE EUT 82 Report No : TRE1411001801 Page 3 of 87 1. TEST STANDARDS AND TEST DESCRIPTION 1.1. Test Standards The tests were performed according to following standards: FCC Rules Part 90 :2014 Private land mobile radio services. TIA/EIA 603 D:June 2010 Land Mobile FM or PM Communications Equipment Measurement and Performance Standards. FCC Part 15 Subpart B:2014 Unintentional Radiators FCC Part 2: 2014 Frequency allocations and radio treaty matters, general rules and regulations. KDB579009 D01 v03r01: Questions and Answers on Re-farming Part 90 frequencies KDB 579009 D02 v01r02 :Transition Summary Table 1.2. Test Description Test specification clause Test case Verdict FCC Part 15.207 Conducted Emission PASS FCC Part 90.205 Maximum Transmitter Power PASS FCC Part 90.207 Modulation Characteristic PASS FCC Part 90.209 Occupied Bandwidth PASS FCC Part 90.210 Emission Mask PASS FCC Part 90.213 Frequency Stability PASS FCC Part 90.214 Transmitter Frequency Behavior PASS FCC Part 90.210 Transmitter Radiated Spurious Emssion PASS FCC Part 90.210 Spurious Emssion On Antenna Port PASS FCC Part 15.109 Receiver Radiated Spurious Emssion PASS Remark: 1.The measurement uncertainty is not included in the test result. Report No : TRE1411001801 Page 4 of 87 2. SUMMARY 2.1. Client Information Applicant: Hytera Communications Co.,Ltd Address: HYT Tower, Hi-tech Industrial Park North,Nanshan District, Shenzhen China Manufacturer: Hytera Communications Co.,Ltd Address: HYT Tower, Hi-tech Industrial Park North,Nanshan District, Shenzhen China 2.2. Product Description Name of EUT Digital Mobile Radio Trade Mark: Hytera Model/Type reference: MD650 U(2) Listed Model(s): MD652 U(2), MD655 U(2), MD656 U(2), MD658 U(2) Power supply: DC 13.6V Charger information: / Adapter information: / Operation Frequency: From 450MHz to 527MHz Rated Output Power: 25 Watts(43.98dBm)/1 Watts(30.00dBm) Support data rate: 9.6kbps Modilation Type: FM for Analog Voice 4FSK for Digital Voice / Digital Data Channel Separation: Analog Voice 12.5KHz,25KHz Digital Voice/Data 12.5KHz Digital Data 12.5KHz Antenna Type: External Note: The product has the same digital working characters when operating in both two digitized voice/data mode. So only one set of test results for digital modulation modes are provided in this test report. Test frequency list Modulation Type Channel Separation Test Frequency (MHz) Analog/FM 12.5KHz 450.5 488.5 526.5 25KHz 450.5 488.5 526.5 Digital/4FSK 12.5KHz 450.5 488.5 526.5 Note: In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the middle frequency, and the highest frequency of channel were selected to perform the test, please see the abo…

Text truncated - open the document above for the full version.

Test Report

MPE TEST REPORT Report Reference No. .................... : TRE1411001802 R/C..........:43921 FCC ID ............................................. : YAMMD65XU2 Applicant’s name ........................... : Hytera Communications Co.,Ltd Address ............................................. : HYT Tower, Hi-Tech Industrial Park North, Nanshan District, Shenzhen China Manufacturer......................................: Hytera Communications Co.,Ltd Address...............................................: HYT Tower,Hi-Tech Industrial Park North, Nanshan District, Shenzhen China Test item description .................... : Digital Mobile Radio Trade Mark ....................................... : Hytera Model/Type reference ....................... : MD650 U(2) Listed Model(s) ................................. : MD652 U(2), MD655 U(2), MD656 U(2), MD658 U(2) Standard ......................................... : FCC Per 47 CFR 2.1091(b) KDB447498 v05r02 Date of receipt of test sample...........: Nov 13, 2014 Date of testing..............................: Nov 13, 2014- Nov 27, 2014 Date of issue.................................: Nov 27, 2014 Result .................. ........................: PASS Compiled by ( position+printed name+signature) .. : File administrators Yingchun Shan Supervised by ( position+printed name+signature) .. : Project Engineer Cary Luo Approved by ( position+printed name+signature) .. : RF Manager Hans Hu Testing Laboratory Name ............. : Shenzhen Huatongwei International Inspection Co., Ltd Address ............................................. : Keji Nan No.12 Road, Hi-tech Park, Shenzhen, China Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Huatongwei International Inspection Co., Ltd is acknowledged as copyright owner and source of the material. Shenzhen Huatongwei International Inspection Co., Ltd takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Report No : TRE1411001802 Page 2 of 7 Contents 1. SUMMARY 3 1.1. Client Information 3 1.2. Product Description 3 1.3. EUT configuration 4 1.4. Modifications 4 2. TEST ENVIRONMENT 5 2.1. Address of the test laboratory 5 2.2. Environmental conditions 5 2.3. Statement of the measurement uncertainty 5 3. METHOD OF MEASUREMENT 6 3.1. Applicable Standard 6 3.2. Limit 6 3.3. MPE Calculation Method 6 4. CONCLUSION 7 Report No : TRE1411001802 Page 3 of 7 1. SUMMARY 1.1. Client Information Applicant: Hytera Communications Co.,Ltd Address: HYT Tower, Hi-tech Industrial Park North,Nanshan District, Shenzhen China Manufacturer: Hytera Communications Co.,Ltd Address: HYT Tower, Hi-tech Industrial Park North,Nanshan District, Shenzhen China 1.2. Product Description Name of EUT: Digital Mobile Radio Trade mark: Hytera Model/Type reference: MD650 U(2) Listed mode(s): MD652 U(2), MD655 U(2), MD656 U(2), MD658 U(2) Power supply: DC 13.6V Charger information: / Adapter information: / Operation Frequency Range: From 450 MHz to 527 MHz Rated Output Power: 25 Watts(43.98dBm)/1Watts(30.00dBm) Modilation Type: Analog Voice: FM Digital Voice/Digital Data: 4FSK Channel Separation: Analog Voice: 12.5KHz, 25 KHz Digital Voice/Digital Data: 12.5KHz Emission Designator: Analog Voice: 11K0F3E for 12.5KHz Channel Separation 16K0F3E for 25KHz Channel Separation Digital Voice: 7K60FXW Digital Data: 7K60FXD Support data rate 9.6kbps Antenna Type External Maximum Transmitter Power Analog 27.67W for 12.5 KHz Channel Separation 27.10W for 25 KHz Channel Separation Digital 27.42W for 12.5 KHz Channel Separation Note: The product has the same digital working characters when operating in both two digitized voice/data mode. So only one set of test results for digital modulation modes are provided in this test report. Test frequency list Modulation Type Test Channel Test Frequency (MHz) Analog/FM Digital/4FSK Lowest channel 450.5 Middle channel 488.5 Highest channel 526.5 Note: In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the middle frequency, and the highest frequency of channel were selected to perform the test, please see the above listed frequency for testing. Report No : TRE1411001802 Page 4 of 7 EUT operation mode The EUT has been tested under typical operating condition and The Transmitter was operated in the normal operating mode. The TX frequency was fixed which was for the purpose of the measurements. Test mode No. Description of operation mode Additional information Op 1 FM+BW12.5KHz+TX The equipment is set with FM modulation and 12.5KHz bandwidth at maximum rated power for transmitter,powered by DC 13.60V Op 2 FM+BW25KHz+TX The equipment is set with FM modulation and 12.5KHz bandwidth at maximum rated power for transmitter,powered by DC 13.60V Op 3 4FSK+BW12.5KHz+TX The equipment is set with 4FSK modulation and 12.5KHz bandwidth at maximum rated power for transmitter,powered by DC 13.60V 1.3. EUT configuration The following peripheral devices and interface cables were connected during the measurement: ● - supplied by the manufacturer β—‹ - supplied by the lab ● Power Cable Length (m) : 3.00 Shield : Unshielded Detachable : Undetachable β—‹ Multimeter Manufacturer : / Model No. : / 1.4. Modifications No modifications were implemented to meet testing criteria. Report No : TRE1411001802 Page 5 of 7 2. TEST ENVIRONMENT 2.1. Address of the test laboratory Shenzhen Huatongwei International Inspection Co., Ltd Keji Nan No.12 Road, Hi-tech Park, Shenzhen, China Phone: 86-755-26715686 Fax: 86-755-26748089 The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 (2009) and CISPR Publication 22. 2.2. Environmental conditions During the measurement the environmental conditions were within the listed ranges: Temperature: 15-35 Β° C H…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No : TRE1411001801 Page 90 of 97 5. Test Setup Photos of the EUT Report No : TRE1411001801 Page 91 of 97

Contact Information

Applicant

Ruifen Huang(Certification Engineer)
[email protected]+86-755-26972999Fax: +86-755-86139020

Test Firm

Shenzhen Huatongwei International Insp. Co., LtdMoffy Yu
[email protected]86-755-26748078Fax: 86-755-26748089

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
49450 MHz - 527 MHz25 W7K40FXW0.95 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 26.1 Watts. This transmitter must operate in push-to-talk mode with a duty factor not exceeding 50% and must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational/Controlled exposure limit and also have control of the exposure conditions of bystanders for complying with General Population/Uncontrolled exposure limit. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. The antenna(s) used for this transmitter must be installed to provide configurations and separation distances as described in this filing.

Other Applications from Hytera Communications Corporation Limited

Digital Portable Radio - FCC ID YAMBP516LF - Hytera Communications Corporation Limited
YAMBP516LF

Digital Portable Radio

Aug 15, 2022

Equipment Class

FRF - Part 95 Family Radio Face Held Transmitter
Digital Portable Radio - FCC ID YAMBP5XXVHF - Hytera Communications Corporation Limited
YAMBP5XXVHF

Digital Portable Radio

Mar 01, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
PoC Radio - FCC ID YAMPNC360S - Hytera Communications Corporation Limited
YAMPNC360S

PoC Radio

Jan 19, 2022

Equipment Class

DTS - Digital Transmission System
DIGITAL MOBILE RADIO - FCC ID YAMHM78XUVS - Hytera Communications Corporation Limited
YAMHM78XUVS

DIGITAL MOBILE RADIO

Jul 28, 2021

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Digital Portable Radio - FCC ID YAMHP6XXUMS - Hytera Communications Corporation Limited
YAMHP6XXUMS

Digital Portable Radio

Jul 22, 2021

Equipment Class

DTS - Digital Transmission System