FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. GreenField Direct, LCC/
  3. YBR-VP100

YBR-VP100PipeBurst Pro

GreenField Direct, LCC
PipeBurst Pro - FCC ID YBR-VP100 - GreenField Direct, LCC
Click to zoom

Application Details

Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
Dec 27, 2010
Application Purpose
Original Equipment
Date of Application
Dec 27, 2010
Equipment Note
PipeBurst Pro
Frequency Range
433.92000000 - 433.92000000
Company
GreenField Direct, LCC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

20100419_PipeBurst Pro Installation Instructions and User Manual 1 | Page General Introduction & Key Features Quick Setup Guide Installation: Precautions General Tools Needed Pipe Burst Pro - Getting Started 1 2 3 4 5 Sync/OffLine FRV/Test Water On‐Off LMM/SLA CSI/Rset ( ) ( ) (◄) (►) 1. VIP: Valve Interface Panel_ VP100 Installation Guide Quick Setup Detailed Setup Instructions (include how to connect to your alarm system, etc) LED Signals & Alerts Trouble Shooting A. Use cases will document the operation of the Valve Interface Panel (VIP) module in: 1. LAM: “Leak Active Mode” (Normal Operation with TickerValve) 2. LMM: “Leak Monitor Mode” (PB256 Notifier system w/o TickerValve) 3. Sync Mode The VIP is normally in Leak Active Mode and uses the five LEDs above their respective keys to display information about the state of the system and current settings of options. B. Leak Active Mode – Active Mode will be entered when a VIP is first powered up and is considered the Normal Mode of operation for the VIP. 1. The following will be displayed on the five LEDs in the Leak Active Mode: 1. GREEN = System OK – Sync Progress - Active Mode – All On-Line – or: Blink RED = Lost Sync – or: Blink GREEN = None Sync’d: The LED above the #1 20100419_PipeBurst Pro Installation Instructions and User Manual 2 | Page (▲) button is used to indicate the sync state. This LED is used during the sync process to indicate sync progress (defined later in this document) and also in the Leak Monitor Mode to indicate all devices are on-line (green) or that a previously sync’d FloodBug (FB) or FloTrax (FT) has gone off-line (blinking red). If no devices are sync’d with the VIP then this LED will blink green. 2. GREEN = Freeze Relief Valve (FRV) Closed. RED Blink = FRV Open. UNLIT = No FRV present in system. HOLD 7 Seconds to cycle FRV simultaneously with (TV). The second LED above the (▼) button) is used to indicate the state of the FRV (if one is installed). A red blinking LED indicates the FRV is Open and a green LED indicates the FRV is Closed (its normal operating position). An unlit LED indicates an FRV is not present in the system (determined by the cycling of the main TickerValve (TV) and FRV). The (▼) button is used to initiate an immediate test cycle of both valves (by holding down the button for more than 7 seconds). 3. GREEN = TV Open. RED = TV Closed. Green/Red Blink = No TV detected, are using Leak Monitor Mode. The center LED displays the state of the main TV (TickerValve) (green for ON, and blinking red for OFF). This large center button gives the ability to toggle the ON-OFF TV state. If no TV is detected (tested only when valve is cycled) this LED will blink red and green (as when used in Leak Monitor Mode only without a TV connected). 4. GREEN = LAM selected. Green Blink = LMM selected; Hold 7 seconds (no TV in system). Red Blink = Check SLA battery. Green/Red = No AC power. The fourth LED above the (◄) button) is used to indicate whether LAM (Leak Active Mode, normal) or LMM (Leak Monitor Mode, auxiliary) has been selected and will also display an indication of a weak or missing SLA back-up battery. 1. Under normal operation this LED will be continuously green, unless an SLA alarm condition exists. 2. When LMM has been selected by holding the (◄) button for a period of more than 7 seconds (meaning that a main TV (TickerValve is not connected to the VIP), then this LED will be blinking green. If an SLA alarm condition exists it will blink red. 3. If AC power is present and the SLA battery is weak and needs to be replaced, (or is not even present), this LED will blink red regardless of the LEAK MODE setting. 4. When AC power is lost this LED will blink red and green regardless of the LEAK MODE setting. 5. GREEN = CSI OK. Red Blink = Fault. Press 7 seconds to clear fault or to do master reset/clear system. The rightmost LED indicates the CSI (Critical System Indication) state and the (►) button gives the ability to perform a master reset of the VIP. A master reset will be performed after this button is held down for at least 7 seconds. The master reset clears (turns green) all faults including the CSI. (1) ENTER SYNC MODE: Press 2 seconds. Press 7 seconds to CLEAR ALL SYNC’D DEVICES: (Note: cannot be undone!). SYNC MODE – The VIP Sync Mode can be initiated using a remote FloTrax (FT), to perform either a FT sync or a FloodBug (FB) sync, or from the VIP by pressing the (▲) button for more than 2 seconds; but not more than 7 seconds for a FB sync. 20100419_PipeBurst Pro Installation Instructions and User Manual 3 | Page (4) IN SYNC MODE: Red Blink until sync request is received. Red/Green + Chirp = sync confirmed. Repeat for each device. 5 minute timeout. Once the VIP is in sync mode the (◄) LED will blink red until it receives a Sync Request Message. Once the VIP receives a Sync Request Message it will send a Sync Pending Message to the device’s (FB or FT) serial number it received during the Sync Request Message. The VIP will then begin to blink this LED red and green and also audibly “chirp” before a Sync Complete Message is sent. The VIP will then return to its previous monitor mode (default is LAM). A. If no Sync Request Message is received within 5 minutes of initiating the sync, the sync process will be aborted. Then the sync LED (◄) will blink red for 10 seconds and the VIP will return to previous monitor mode. B. The (▲) button is also used to clear all sync information from the VIP, FT, and FB. This clear sync function is accessed by pressing the sync button (▲) for more than 7 seconds. Print for VIP Faceplate – Quick Reference Guide 1. ▲ GREEN = System OK – Sync Progress - Active Mode – All On-Line – or: Blink RED = Lost Sync – or: Blink GREEN = None Sync’d. ENTER SYNC MODE: Press 2 seconds. Press 7 seconds to CLEAR ALL SYNC’D DEVICES: (Note: cannot be undone!). 2. ▼ GREEN = Freeze Relief Valve (FRV) Closed. RED Blink = FRV Open. UNLIT = No FRV present in system. HOLD 7 Seconds to cycle FRV si…

Text truncated - open the document above for the full version.

Cover Letter(s)

Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521-5376 Phone: 402.472.5880 Fax: 402.472.5881 Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521-5376 Phone: 402.472.5880 Fax: 402.472.5881 04/07/09 - 3 Request for Confidentiality Date: 17 June 2010 Subject: Confidentiality Request for FCC ID: YBR-FB100, YBR-FT100, YBR-VP100 IC ID: 8924A-FB100, 8924A-FT100, 8924A-VP100 Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Permanent* 3 Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Schematics Short Term Test Setup Photos Short Term Permanent* User’s Manual *Note: ______(Insert Explanation as Necessary)______ Greenfield Direct, LLC has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of ___(specify number of days not to exceed 180 ) 4 ___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ATCB in the event information regarding the product or the product is made available to the public. ATCB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, By: __________________________ Nic Johnson, Test Engineer (signing on behalf of Greenfield Direct as an agent) (Signature/Title (Print name) 3 - The asterisked items (*) require further justification before permanent confidentiality will be allowed. These also currently require review by the FCC under their Permit-But-Ask policy before the grant is issued and can delay completion of an application. Further justification should be added to the note above. One such example for a potted device would be: “The EUT is FULLY potted using a non-removable epoxy based material. Removal of potting material causes irreparable damage to internal circuitry. See photographs exhibits that outline the device before and after potting.” 4 - Please refer to http://atcb.com/publicdocs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details.

External Photos

NCEE Labs FCC ID: YBR‐VP100 External Photos: VIP IC ID: 8924A‐VP100 NCEE Labs External P s Photos: VIP F IC FCC ID: YBR‐V C ID: 8924A‐V VP100 VP100

ID Label/Location Info

Model Number on Label Model Number on Label FCC Label Placement – Valve Interface Panel and FloodBug John Ostrander 12/8/10 Valve Interface Panel (VIP) – GF9002 The VIP will ship with the power plugs unconnected. System startup will require the power to be connected to the printed circuit board on the inside front face of the VIP. The VIP face plate will have to be removed to connect the sealed lead acid battery and the AC power which will reveal the FCC label. The sealed lead acid battery is connected to the VIP through the 4‐terminal receptacle, and the AC power is connected to the VIP through the 2‐terminal receptacle, as shown in the figures below. The VIP section of the PipeBurst Pro Installation and User’s Manual includes the text, “The FCC label is located on the inside lower surface of the VIP case, visible during the AC power and battery backup installation ” to notify the user of its existence and location. Figure 1 ‐ VIP as shipped with the face plate installed Figure 2 ‐ VIP back showing DC cord entry point Figure 3 ‐ Power connection points on the VIP circuit board Figure 4 ‐ Power connection points connected on VIP circuit board and FCC ID Label location

Internal Photos

NCEE Labs FCC ID: YBR‐VP100 Internal Photos: VIP IC ID: 8924A‐VP100 NCEE Labs FCC ID: YBR‐VP100 Internal Photos: VIP IC ID: 8924A‐VP100 NCEE Labs FCC ID: YBR‐VP100 Internal Photos: VIP IC ID: 8924A‐VP100 NCEE Labs FCC ID: YBR‐VP100 Internal Photos: VIP IC ID: 8924A‐VP100 NCEE Labs FCC ID: YBR‐VP100 Internal Photos: VIP IC ID: 8924A‐VP100 NCEE Labs FCC ID: YBR‐VP100 Internal Photos: VIP IC ID: 8924A‐VP100

Test Report

Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521-5376 Phone: 402.472.5880 Fax: 402.472.5881 Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521-5376 Phone: 402.472.5880 Fax: 402.472.5881 The Nebraska Center for Excellence in Electronics (NCEE) authorizes the above named company to reproduce this report provided it is reproduced in its entirety for use by the company’s employees only. Any use that a third party makes of this report, or any reliance on or decisions made based on it, are the responsibility of such third parties. NCEE accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. This report applies only to the items tested. NCEE is a FCC and Industry Canada registered lab. FCC #100875, IC #4294 Amended Test Report Company: Greenfield Direct, LLC 14015 238 th St. Greenwood, NE 68003 Contact: Scott Miner Product: VIP FCC ID: YBR-VP100 IC ID: 8924A-VP100 Test Report No: R031510-01-03A APPROVED BY: Nic Johnson _________________________ Test Engineer DATE: 14 December 2010 Total Pages: 27 NCEE Labs R031510-01-03A FCC ID:YBR-VP100 IC ID:8924A-VP100 Page 2 of 27 1.0 Summary of test results 1.1 Test Results 1.2 Reason for amendment 2.0 Description 2.1 Equipment under test 2.2 Laboratory description 2.3 Description of test modes 2.4 Applied standards 2.5 Configuration of system under test 2.6 Duty Cycle Calculation 3.0 Test equipment used 4.0 Detailed Results 4.1 15.207 Conducted Emissions 4.2 15.209, 15.231 Radiated emissions 4.3 15.231 Bandwidth Appendix A – Test photos Appendix B – Table of figures NCEE Labs R031510-01-02A FCC ID:YBR-FT100 IC ID:8924A-FT100 Page 3 of 27 1.0 Summary of test results 1.1 Test Results The EUT has been tested according to the following specifications: APPLIED STANDARDS: 47 CFR Part 15 & RSS-210 Standard Section Test Type and Limit Result Remark 15.207 RSS-Gen Conducted AC Mains Emissions Pass Meets the requirement of the limit. 15.209, 15.231 RSS-Gen Radiated Emissions Peak Output Field Strength Limit: 80.83dBμV/m Pass Meets the requirement of the limit. 15.231 RSS-210 Issue 7 Bandwidth Pass Meets the requirement of the limit. 1.2 Test Results The report was amended to make the addition of section 2.6 to show measurements of the EUTs duty cycle in alarm mode, which is the highest possible transmitting rate that the EUT can operate in. This report, R031510-01-03A is meant to amend and replace report R031510-01-03. NCEE Labs R031510-01-02A FCC ID:YBR-FT100 IC ID:8924A-FT100 Page 4 of 27 2.0 Description 2.1 Equipment under test The VIP (Valve Interface Panel) is the heart of the Pipe Burst Pro system. This assembly maintains all setting and state information for itself as well as for the FloTrax and the FloodBug components in the system. The VIP receives and processes alarm and status messages from all other system components and also controls other system components including the FloTrax, the Ticker Valve, the Pressure Release Valve, and any attached alarm system. The VIP also can maintain a battery backup, keeping an SLA battery charged and periodically testing quality of the SLA battery and indicating when to replace it. The VIP also maintains system time through the use of an onboard real time clock chip. The VIP is powered using an external 18 VDC power adapter. The 18 VDC input is connected to the to the main power buss thru a diode isolated battery backup switch circuit. The internal 12 VDC SLA battery is also connected to this circuit and will automatically power the main buss if the external 18 VDC power is lost. The EUT is supplied with a 18VDC Tech Power Int. power supply, ETSA40- 180222TI. EUT Received Date: 4/21/2010 EUT Tested Date: 4/21/2010 MODEL VIP POWER SUPPLY 18VDC Ac-DC Adapter MODULATION TYPE FSK FREQUENCY RANGE 433.92MHz NUMBER OF CHANNELS 1 MAXIMUM OUTPUT POWER 77.04dBμV/m at 3m (Average over 2sec) ANTENNA TYPE Internal dipole I/O PORTS None ASSOCIATED DEVICES FloTrax, FloodBug NOTE: 1. For more detailed features description, please refer to the manufacturer's specifications or User's Manual. 2.2 Laboratory description All testing was performed at the NCEE Lincoln facility, which is a FCC and IC registered lab. This site has been fully described in previously submitted reports. Laboratory environmental conditions varied slightly throughout the tests: Relative humidity of 45 ± 4% Temperature of 20 ± 3° Celsius NCEE Labs R031510-01-02A FCC ID:YBR-FT100 IC ID:8924A-FT100 Page 5 of 27 2.3 Description of test modes The EUT was modified by the manufacturer to transmit continuously for testing purposes. It was set to transmit one packet after another with 20ms in between transmissions 2.4 Applied standards The EUT is a low-power transmitter device operating on one frequency at 433.92MHz. According to the specifications of the manufacturer, it must comply with the requirements of the following standards: FCC Part 15.207, 15.209 and 15.231 using ANSI/IEEE C63.4: 2003 Industry Canada, RSS 210, Issue 7, Category I Equipment All test items have been performed and recorded as per the above standards. 2.5 Configuration of system under test The EUT was set to transmit at a rate much higher than normal use for the purpose of testing. The EUT was also tested in a mode of operation in which it ran in its normal operating condition, waiting to receive data. The EUT was tested with the 18VDC power supply. 2.6 Duty Cycle Calculation A transmitter activated automatically shall cease transmission within 5 seconds after activation The VIP is designed to have no regular transmissions. The only time the VIP transmits is in response to (acknowledgement of) alarm and control transmissions made by the FloodBugs and FloTrax. When the FloTrax sends the VIP control signals in response to changes in operating parameters initiated by the consumer or when the FloodBug sends alarm transmissions the VIP responds by sending ne…

Text truncated - open the document above for the full version.

Test Setup Photos

NCEE Labs FCC ID: YBR‐VP100 Test Photos: VIP IC ID: 8924A‐VP100 NCEE Labs FCC ID: YBR‐VP100 Test Photos: VIP IC ID: 8924A‐VP100

Contact Information

Applicant

Scott Morgan(CFO)
[email protected]402-944-2767Fax: 402 944 2402

Technical Contact

NCEE LabsNic Johnson
[email protected]402-472-5880

4740 Discovery Dr. · Lincoln, Nebraska · United States

Test Firm

Nebraska Center for Excellence in ElectronicsNic Johnson
[email protected]4023236233Fax: 4024725881

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from GreenField Direct, LCC

Wireless Water Detector Sensor - FCC ID YBR-FB-2 - GreenField Direct, LCC
YBR-FB-2

Wireless Water Detector Sensor

Oct 18, 2011

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Automatic Water Protection System - FCC ID YBR-FB100 - GreenField Direct, LCC
YBR-FB100

Automatic Water Protection System

Dec 27, 2010

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
PipeBurst Pro - FCC ID YBR-FT100 - GreenField Direct, LCC
YBR-FT100

PipeBurst Pro

Jul 14, 2010

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver