1 User Manual Model: Lenovo E160C Please read this manual carefully before operating this product. Lenovo Mobile Phone 2 Thank you for choosing Lenovo products. Lenovo Mobile follows the policy of continuous development. Therefore, Lenovo Mobile reserves the right to modify and improve any products described in this document without notice in advance. Under any circumstance, Lenovo Mobile bears no responsibility for any data or income loss or any special, incidental, special or consequential loss, regardless of the reasons of such loss. Content of this document is provided to users on “as is” basis. Unless otherwise stipulated in applicable laws, no guarantee of any nature, whether express or implied, is made concerning the accuracy, reliability and content of this document, including without limitation to merchantability or suitability for a specific purpose. Lenovo Mobile reserves the right to revise or withdraw this document without notice in advance. For the information of the newest documents, please refer to http://www.lenovomobile.com. This manual aims to help you correctly use Lenovo products, but does not include any instructions for software and hardware configuration of the product. For configuration of the product, please refer to contract related to this product (if any) or consult your dealer. Images in this manual are for reference only. If some images are not consistent with actual products, the latter are seen as standard. Many network functions described in this manual are special services provided by network provider. It depends on the network provider whether these network functions can be used or not. Content of this manual is protected by copyright laws and regulations. You are not allowed to copy or transcribe this manual in any form or transfer this manual via any wireless or cable network in any form, or translate this manual into any language. “Lenovo” is registered trademark authorized by Lenovo (Beijing) Ltd. to Lenovo Mobile Communication Technology Ltd. All other names and products are or may be trademarks or registered trademarks of Lenovo and other companies. “Lenovo” is registered trademark authorized by Lenovo (Beijing) Ltd. to Lenovo Mobile Communication Technology Ltd. “Dolby” and “double-D” are registered trademark or trademark of and authorized by Dolby Laboratories Inc. to Lenovo Mobile Communication Technology Ltd. All other names and products mentioned in this Manual are or may be registered trademarks or trademarks of Lenovo or other companies. 3 目录 1. Safety and Maintenance ---------------------------------------------------------------------- 4 2. Installation and Charging -------------------------------------------------------------------- 8 2.1 INSTALL THE BATTERY .......................................................................................... 8 2.2 CHARGE THE BATTERY ......................................................................................... 8 2.3 INSTALL THE UIM CARD ........................................................................................ 9 2.4 HOW TO POWER ON/OFF ...................................................................................... 9 2.5 SECURITY PASSWORD ........................................................................................ 10 2.5.1 PIN code .................................................................................................... 10 2.5.2 PUK code .................................................................................................. 10 3. Phone Layout and Key Functions ------------------------------------------------------- 11 3.1 KEY DESCRIPTION .............................................................................................. 11 4. Main Function Guide ------------------------------------------------------------------------- 12 4.1 MAKING A CALL .................................................................................................. 12 4.2 DIALING AN EMERGENCY NUMBER ...................................................................... 12 5. Input Methods ---------------------------------------------------------------------------------- 13 5.1 PINYIN INPUT METHOD ....................................................................................... 13 5.2 STROKE INPUT METHOD ..................................................................................... 13 5.3 LETTER INPUT METHOD ...................................................................................... 13 5.4 NUMBER AND SYMBOL INPUT METHOD ................................................................ 13 5.5 SMART ENGLISH INPUT METHOD ......................................................................... 13 6. Function List ------------------------------------------------------------------------------------ 14 7. Technical Parameters ----------------------------------------------------------------------- 15 8. Important Security Information —Electromagnetic Radiation Performance Index (SAR) -------------------------------------------------------------------------- 16 9. Important Security Information —Medical Equipment --------------------------- 17 4 1. Safety and Maintenance Please follow the precautions below to use your phone: •Please read this manual carefully before using this phone. •If use of mobile phone is prohibited or will lead to interference or danger, do not power on your phone. •You are prohibited to use a mobile phone on board an aircraft, so keep it powered off. If the alarming and calendar features of your mobile phone can automatically power on your phone, check and disable these features before boarding an aircraft. •When using your mobile phone, please keep it away from heat sources or high-voltage environment, such as electric appliances and electric-heated cooking appliances. Please use your mobile phone under normal temperature, because extreme temperature (over 55°C or below -10°C) is harmful to your phone. •Guard agai…
Text truncated - open the document above for the full version.
Date: Sep 21, 2010 Subject: FCC ID: YCNE160C Attestation of USB port The USB port of this device is only used for charging, it is not available to transfer data by connect to a personal computer. Thank you for your attention to this matter. Yours Sincerely, Shouyu Qiu Manager Lenovo Mobile Communication Technology Ltd.
Date: Sep 21, 2010 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 To Whom It May Concern: The Lenovo Mobile Communication Technology Ltd., the undersigned, hereby authorizes Mr. Wu Xuewen from Shenzhen Morlab Communications Technology Co., Ltd., to act on the behalf of the Lenovo Mobile solely in matters relating to the application for an FCC equipment authorization for FCC ID # YCNE160C including the signing of documents in connection with this Application. Necessary acts carried out by Shenzhen Morlab Communications Technology Co., Ltd. on our behalf of the Lenovo Mobile in connection with the Application shall have the same effect as acts of the Lenovo Mobile. The Lenovo Mobile also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Thank you for your attention to this matter. Yours Sincerely, Shouyu Qiu Manager Lenovo Mobile Communication Technology Ltd.
Date: Sep 21, 2010 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 Re: Lenovo Mobile Communication Technology Ltd. FCC ID: YCNE160C FCC Certification Confidentiality Request Gentlemen: This letter is to comply with 47 CFR 0.457 and 0.459 pertaining to confidentiality material. Lenovo Mobile requests that the following documents regarding this submission for FCC ID: YCNE160C be kept confidential: Exhibit Type File Name Block Diagram CONF APPENDIX YCNE160C_Block Diagram.pdf Schematics CONF APPENDIX YCNE160C_Schematics.pdf Operational Description CONF APPENDIX YCNE160C_Operational Specification.pdf Part list CONF APPENDIX YCNE160C_BOM.pdf Tune-Up-Procedure CONF APPENDIX YCNE160C_Tune up procedure.pdf Those documents contain detailed system and equipment description and related information about the product which Lenovo Mobile considers to be confidential proprietary, a custom design and, otherwise, not releasable to the general public. Since this design is a basis form which future technological products will evolve, Lenovo Mobile considers this information would be of benefit to its competitors, and that the disclosure of the information in these documents would give competitors an unfair advantage in the market. Shouyu Qiu Manager Lenovo Mobile Communication Technology Ltd.
External Photos 1. Front View of EUT 2. Back View of EUT 3. Side View of EUT
Label Label Location
Date: Sep 21, 2010 Equipment Authorization Division Office of Engineering and Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Ref: FCC ID: YCNE160C Dear Sirs: Lenovo Mobile Communication Technology Ltd. requests acceptance of the labeling proposal described below for cell phone bearing FCC identifier YCNE160C. The subject cell phone are compact handheld models as shown in figure 1, authorized under 47CFR Part 22H for CDMA mobile services. Figure 1. Because the majority of the cell phone housing is composed of display, speaker, operating controls and a removable battery pack, there is extremely limited space available to attach the required label carrying the FCC identifier. Attaching the label to the battery pack is not acceptable because the battery pack is a removable item. For this reason, Lenovo Mobile proposes placing the label carrying the FCC identifier inside the battery compartment as shown in figure 2. Figure 2. The consumer packaging for these models includes the battery pack as a separate item, NOT installed on the radio. As such, the FCC identifier will be readily visible to the user before the battery pack is installed and whenever the battery pack is removed or replaced. In this location, the label will also be protected from physical abuse and remain readable for the anticipated life of the device. The consumer packaging for these models is a "gift box" which does not allow the transceiver to be seen at time of purchase. In order to meet the requirements of 47CFR Part 2.925 (d), Lenovo Mobile will add the FCC identifier "YCNE160C" to the outside of the consumer "gift box" packaging. Thank you for your attention to this matter. Yours Sincerely, Shouyu Qiu Manager Lenovo Mobile Communication Technology Ltd.
Internal Photos
Report No.: SZ10090062S01 Page 2 of 81 Contents 1. GENERAL INFORMATION....................................................................................................4 1.1. Notes.........................................................................................................................................4 1.2. Organization item....................................................................................................................4 1.3. Conclusion................................................................................................................................4 2. TESTING LABORATORY.......................................................................................................5 2.1. Identification of the Responsible Testing Laboratory..........................................................5 2.2. Identification of the Responsible Testing Location..............................................................5 2.3. Accreditation Certificate........................................................................................................5 2.4. List of Test Equipments..........................................................................................................5 3. TECHNICAL INFORMATION ...............................................................................................6 3.1. Identification of Applicant......................................................................................................6 3.2. Identification of Manufacturer..............................................................................................6 3.3. Equipment Under Test (EUT)................................................................................................6 3.3.1. Photographs of the EUT..................................................................................................7 3.3.2. Identification of all used EUTs........................................................................................7 3.4. Applied Reference Documents...............................................................................................7 3.5. Device Category and SAR Limits..........................................................................................7 3.6. Test Environment/Conditions................................................................................................8 4. SPECIFIC ABSORPTION RATE (SAR) ................................................................................9 4.1 Introduction.................................................................................................................................9 4.2 SAR Definition.............................................................................................................................9 5. SAR MEASUREMENT SETUP .............................................................................................10 5.1. The Measurement System....................................................................................................10 5.2. Probe.......................................................................................................................................11 5.3. Phantom.................................................................................................................................13 5.4. Device Holder........................................................................................................................13 6. TISSUE SIMULATING LIQUIDS .........................................................................................14 7. UNCERTAINTY ASSESSMENT ...........................................................................................16 7.1. UNCERTAINTY EVALUATION FOR HANDSET SAR TEST......................................16 Report No.: SZ10090062S01 Page 3 of 81 7.2. UNCERTAINTY FOR SYSTEM PERFORMANCE CHECK........................................17 8. SAR MEASUREMENT EVALUATION ...............................................................................19 8.1. System Setup..........................................................................................................................19 8.2. Validation Results..................................................................................................................19 9. OPERATIONAL CONDITIONS DURING TEST ................................................................20 9.1. Informations on the testing..................................................................................................20 9.2. Body-worn Configurations...................................................................................................21 9.3. Measurement procedure.......................................................................................................21 9.4. Description of interpolation/extrapolation scheme............................................................22 10. MEASUREMENT PROCEDURES........................................................................................23 10.1. Procedures Used To Establish Test Signal...........................................................................23 10.2. SAR Measurement Conditions for CDMA.........................................................................23 10.3. Output Power Verification...................................................................................................23 10.4. SAR Measurement................................................................................................................23 11. TEST RESULTS LIST .............................................................................................................25 ANNEX A ACCREDITATION CERTIFICATE................................................26 ANNEX B PHOTOGRAPHS OF THE EUT......................................................27 ANNEX C GRAPH TEST RESULTS .................................................................30 Change Hist…
Text truncated - open the document above for the full version.
Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 1/26 Issue: A Date: 2010/10/06 1 COMOSAR E-FIELD PROBE CALIBRATION REPORT Prepared By: LUC Jérôme, SATIMO Project Description: SAR TEST BENCH Prepared For (End User): Shenzhen Morlab Communication Technology This document is issued by SATIMO, in confidence and is not to be reproduced in whole or in part without the prior written permission. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or in part without the prior written permission of SATIMO. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 2/26 Issue: A Date: 2010/10/06 2 COMOSAR SEPT ISOTROPIC E-FIELD PROBE CALIBRATION REPORT DATE: 12/02/2009 REFERENCE: SN 37/08 EP80 OBJECT: COMOSAR SEPT ISOTROPIC E-FIELD PROBE MANUFACTURER: SATIMO SERIAL NUMBER: SN 37/08 EP80 CUSTOMER: Shenzhen Morlab Communication Technology CONTRACT: PF2130108b_SAR_Morlab DATE OF CALIBRATION: 24/09/20 10 WARRANTY: This Calibration certificate may not be reproduced other than in full. Calibration certificates without signature and seal are not valid. This documentation contains property information which is protected by copyright. All right are reserved. No part of this document may be photocopied, reproduced without the prior written agreement of SATIMO. SATIMO shall not be liable for errors contained herein or for incidental or consequential in connection with the furnishing, performance or use of this material. Warranty doesn’t apply to Normal wear, Normal tear, Improper use, Improper maintain, Improper installation. Date SAR TEAM MANAGER Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 3/26 Issue: A Date: 2010/10/06 3 PRODUCT DESCRIPTION Frequency Range 100 MHz - 30 GHz Probe length 330 mm Length of one dipole 4.5 mm Maximum external diameter 8 mm Probe extremity diameter 6.5 mm Distance between dipoles/probe extremity < 2.7 mm Resistance of the three dipole (at the connector) Dipole 1: R1=1.4382 MΩ Dipole 2: R2=1.4894 MΩ Dipole 3: R3=1.4683 MΩ Connector (HIROSE series SR30) 6 wire male (Hirose SR30series) The probe could be checked by measuring the resistance of the three dipoles. CALIBRATION TEST EQUIPMENT TYPE IDENTIFICATION Calibration bench CALISAR Multimeter Keithley 2000 Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 4/26 Issue: A Date: 2010/10/06 4 MEASUREMENT PROCEDURE Probe calibration is realized, in compliance with CENELEC EN 50361 and IEEE 1528 std, with CALISAR, Antennessa proprietary calibration system. The calibration is performed with the EN 50361 annexe technique using reference guide at the five frequencies. Where : P fw = Forward Power P bw = Backward Power a and b = Waveguide dimensions = Skin depth Keithley configuration: Rate = Medium; Filter =ON; RDGS=10; FILTER TYPE =MOVING AVERAGE; RANGE AUTO After each calibration, a SAR measurement is performed on a validation dipole and compared with a NPL calibrated probe, to verify it. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 5/26 Issue: A Date: 2010/10/06 5 PROBE UNCERTAINTIES Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 6/26 Issue: A Date: 2010/10/06 6 1. Calibration at 450.00 MHz A. Calibration parameters. Label GSM450 Epsilon 43.33 Sigma 0.84 S/m Temperature 21°C Antenna gain 2.03 dB Antenna S11 -10.50 dB Low limit detection (CW) 0.72 V/m (0.47 mW/kg) Calibration curves ei=f(V) (i=1,2,3) allow to obtain E-field value using the formula: 2 3 2 2 2 1 **EEEE= The following tables represent the calibration curves linearization by curve segment in CW signal. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 7/26 Issue: A Date: 2010/10/06 7 Calibration coefficients for the three dipoles in CW: v1 e1 v2 e2 v3 e3 0.584004 419.557857 -0.696059 435.622023 0.541191 412.830715 0.467833 339.207465 -0.556278 351.381991 0.469757 336.297240 0.376994 276.348283 -0.452232 288.647980 0.378826 274.224190 0.302778 224.954643 -0.359005 232.397390 0.305842 224.365698 0.241038 182.154071 -0.286978 188.889931 0.246562 183.825274 0.192549 148.484090 -0.230386 154.650994 0.195712 148.993075 0.154033 121.674762 -0.185412 127.378480 0.157543 122.783107 0.123397 100.276479 -0.147311 104.193802 0.125866 100.956090 0.099878 83.770361 -0.118637 86.660489 0.101471 84.063863 0.081165 70.553219 -0.095250 72.263937 0.082289 70.694342 0.065166 59.152028 -0.076788 60.795323 0.066427 59.538957 0.051916 49.592416 -0.061280 51.041514 0.053353 50.232492 0.041968 42.297602 -0.048746 43.022565 0.042906 42.675214 0.033724 36.126757 -0.039149 36.748110 0.034686 36.605243 0.021855 26.962568 -0.024798 27.024723 0.022272 27.149463 0.018405 23.975145 -0.020856 24.085809 0.018755 24.141334 0.015467 21.515985 -0.017534 21.515985 0.015767 21.615299 0.013018 19.309065 -0.014750 19.398191 0.013276 19.487731 0.010938 17.408496 -0.012392 17.529166 0.011157 17.569575 0.009022 15.586953 -0.010228 15.658899 0.009215 15.676938 0.007353 13.956010 -0.008328 13.988181 0.007484 14.020428 0.005989 12.466979 -0.006801 12.495719 0.006111 12.567858 0.004890 11.214019 -0.005573 11.265779 0.005003 11.330818 0.004019 10.133541 -0.004570 10.121882 0.004099 10.168601 0.003279 9.094132 -0.003739 9.157170 0.003352 9.125596 0.002660 8.095827 -0.003041 8.293946 0.002769 8.265350 0.002126 7.324219 -0.002453 7.366500 0.002188 7.358024 0.001685 6.565400 -0.001947 6.580536 0.001724 6.542765 0.001300 5.784440 -0.001511 5.718225 0.001334 5.757862 0.001123 5.245191 -0.001307 5.269400 0.001174 5.275471 0.000891 4.701768 -0.001057 4.723470 0.000924 4.728912 0.000704 4.209798 -0.000850 4.226839 0.000736 4.243862 0.000574 3.790376 -0.000689 3.791428 0.000603 3.830551 0.000457 3.396200 -0.000570 3.434303 0.000483 3.421852 0.000365 3.050686 -0.000463 3.078014 0.000389 3.079630 0.000292 2.745766 -0.000369 2.726866 0.000311 2.759206 0.000236 2.486639 -0.000312 2.489933 0.000246 2.460514 0.000…
Text truncated - open the document above for the full version.
Ref: CR-280-3-08-SATB-B COMOSAR Dipole 835 MHz Calibration Report Page: 1/6 Issue: B Date: 2010/10/05 1 DIPOLE 835 MHZ CALIBRATION REPORT Prepared By: LUC Jérôme, SATIMO Project Description: SAR TEST BENCH Prepared For (End User): Shenzhen Morlab Communication Technology This document is issued by SATIMO, in confidence and is not to be reproduced in whole or in part without the prior written permission. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or in part without the prior written permission of SATIMO. Ref: CR-280-3-08-SATB-B COMOSAR Dipole 835 MHz Calibration Report Page: 2/6 Issue: B Date: 2010/10/05 2 DIPOLE 835 MHz CALIBRATION REPORT DATE: 19/02/2009 REFERENCE: SN 36/08 DIPC99 OBJECT: COMOSAR IEEE REFERENCE DIPOLE MANUFACTURER: SATIMO SERIAL NUMBER: SN 36/08 DIPC99 CUSTOMER: Shenzhen Morlab Communication Technology CONTRACT: PF2130108b_SAR_Morlab DATE OF CALIBRATION: 2 3/09/2010 WARRANTY: This Calibration certificate may not be reproduced other than in full. Calibration certificates without signature and seal are not valid. This documentation contains property information which is protected by copyright. All right are reserved. No part of this document may be photocopied, reproduced without the prior written agreement of SATIMO. SATIMO shall not be liable for errors contained herein or for incidental or consequential in connection with the furnishing, performance or use of this material. Warranty doesn’t apply to Normal wear, Normal tear, Improper use, Improper maintain, Improper installation. Date SAR TEAM MANAGER Ref: CR-280-3-08-SATB-B COMOSAR Dipole 835 MHz Calibration Report Page: 3/6 Issue: B Date: 2010/10/05 3 PRODUCT DESCRIPTION Dimension: L=161 mm/ h=89.8mm / d=3.6 mm CALIBRATION TEST EQUIPMENT TYPE IDENTIFICATION DATE OF CALIBRATION Vector Network Analyzer HP8753D (SN: 5410A08882) 10-05-2010 MEASUREMENT PROCEDURE We placed the dipole under the flat part of SAM phantom fill with 835 MHz head liquid. Ref: CR-280-3-08-SATB-B COMOSAR Dipole 835 MHz Calibration Report Page: 4/6 Issue: B Date: 2010/10/05 4 Calibration was performed according to IEEE Std P1528-2003 and OET bulletin 65 Supplement C (Ed. 01-01) VSWR at 835 MHz: -24.77 dB. -24,77 -40 -35 -30 -25 -20 -15 -10 -5 0 0,7350,8350,935 Frequency (GHz) S11 (dB) Ref: CR-280-3-08-SATB-B COMOSAR Dipole 835 MHz Calibration Report Page: 5/6 Issue: B Date: 2010/10/05 5 SAR MEASUREMENT EQUIPEMENT Voltmeter Keithley (2000, SN:1000572) Date of calibration: 01-07-2010 Signal generator Rohde&Schwarz (SML_03, SN:101868) Date of calibration: 15-11-2009 Power amplifier Nuclétudes (ALB216, SN:10800) Date of calibration: 24-10-2009 Power meter Rohde&Schwarz (NRVD, SN:101066) Date of calibration: 04-07-20 10 Probe SATIMO Bretagne (SN:EP37) CF (30.41,29.18,32.33) Date of calibration: 19-06-2010 SAR MEASUREMENT CONDITION Software OpenSAR V3 Phantom SATIMO Bretagne (SN: SN_20_07_SAM42) Liquid SATIMO Bretagne (Last Calibration: 18 09 08) Head Liquid Values: eps’ : 41,20 sigma : 0,872 Distance between the center of the dipole and the liquid (set with a spacer) 15 mm Area scan resolution dx=8mm/dy=8mm Zoom scan resolution dx=8mm/dy=8m/dz=5mm Frequency 835 MHz Input power 30 dBm Expanded uncertainty (K=1) 8.09% SAR MEASUREMENT RESULT 10g 1g SAR measured Liquid : HL Input power : 1W 6,364 W/Kg + 2,64 % 9,805 W/Kg + 3,21 % Ref: CR-280-3-08-SATB-B COMOSAR Dipole 835 MHz Calibration Report Page: 6/6 Issue: B Date: 2010/10/05 6 SAR MEASUREMENT PLOTS
Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 1/6 Issue: B Date: 2010/10/05 1 DIPOLE 1800 MHZ CALIBRATION REPORT Prepared By: LUC Jérôme, SATIMO Project Description: SAR TEST BENCH Prepared For (End User): Shenzhen Morlab Communication Technology This document is issued by SATIMO, in confidence and is not to be reproduced in whole or in part without the prior written permission. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or in part without the prior written permission of SATIMO. Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 2/6 Issue: B Date: 2010/10/05 2 DIPOLE 1800 MHz CALIBRATION REPORT DATE: 19/02/2009 REFERENCE: SN 36/08 DIPF101 OBJECT: COMOSAR IEEE REFERENCE DIPOLE MANUFACTURER: SATIMO SERIAL NUMBER: SN 36/08 DIPF101 CUSTOMER: Shenzhen Morlab Communication Technology CONTRACT: PF2130108b_SAR_Morlab DATE OF CALIBRATION: 2 3/09/2010 WARRANTY: This Calibration certificate may not be reproduced other than in full. Calibration certificates without signature and seal are not valid. This documentation contains property information which is protected by copyright. All right are reserved. No part of this document may be photocopied, reproduced without the prior written agreement of SATIMO. SATIMO shall not be liable for errors contained herein or for incidental or consequential in connection with the furnishing, performance or use of this material. Warranty doesn’t apply to Normal wear, Normal tear, Improper use, Improper maintain, Improper installation. Date SAR TEAM MANAGER Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 3/6 Issue: B Date: 2010/10/05 3 PRODUCT DESCRIPTION Dimension: L=72 mm/ h=41.7 mm / d=3.6 mm CALIBRATION TEST EQUIPMENT TYPE IDENTIFICATION DATE OF CALIBRATION Vector Network Analyzer HP8753D (SN: 5410A08882) 10-05-2010 MEASUREMENT PROCEDURE We placed the dipole under the flat part of SAM phantom fill with 1800 MHz head liquid. Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 4/6 Issue: B Date: 2010/10/05 4 Calibration was performed according to IEEE Std P1528-2003 and OET bulletin 65 Supplement C (Ed. 01-01) VSWR at 1800 MHz: -25.09 dB -25,09 -35 -30 -25 -20 -15 -10 -5 0 1,71,81,9 Frequency (GHz) S11 (dB) Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 5/6 Issue: B Date: 2010/10/05 5 SAR MEASUREMENT EQUIPEMENT Voltmeter Keithley (2000, SN:1000572) Date of calibration: 01-07-2010 Signal generator Rohde&Schwarz (SML_03, SN:101868) Date of calibration: 15-11-2009 Power amplifier Nuclétudes (ALB216, SN:10800) Date of calibration: 24-10-2009 Power meter Rohde&Schwarz (NRVD, SN:101066) Date of calibration: 04-07-2010 Probe SATIMO Bretagne (SN:EP37) CF (35.35,34.93,37.42) Date of calibration: 19-06-2010 SAR MEASUREMENT CONDITION Software OpenSAR V3 Phantom SATIMO Bretagne (SN: SN_20_07_SAM42) Liquid SATIMO Bretagne (Last Calibration: 19 09 08) Head Liquid Values: eps’ : 39,80 sigma : 1,45 Distance between the center of the dipole and the liquid (set with a spacer) 10 mm Area scan resolution dx=8mm/dy=8mm Zoom scan resolution dx=8mm/dy=8m/dz=5mm Frequency 1800 MHz Input power 30 dBm Expanded uncertainty (K=1) 8.09% SAR MEASUREMENT RESULT 10g 1g SAR measured Liquid : HL Input power : 1W 20,05 W/Kg + 1,24 % 39,32 W/Kg + 3,20 % Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 6/6 Issue: B Date: 2010/10/05 6 SAR MEASUREMENT PLOTS
Report No.: SZ10090062E01 Page 2 of 32 TABLE OF CONTENTS 1. TEST RESULT CERTIFICATION .......................................................................................... 4 2. GENERAL INFORMATION ....................................................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 22H | 824.7 MHz - 848.31 MHz | 640.00 mW | 1M28F9W | 0.1000000000 ppm |

Lenovo Mobile Phone
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Lenovo Mobile Phone
Equipment Class
DTS - Digital Transmission System
Lenovo Mobile Phone
Equipment Class
DTS - Digital Transmission System
Lenovo Mobile Phone
Equipment Class
PCE - PCS Licensed Transmitter held to ear
Lenovo Mobile Phone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter