Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 13, 2020
Application Purpose
Original Equipment
Date of Application
Sep 13, 2020
Equipment Note
Thermal Transfer Label Printer
Frequency Range
2402.00000000 - 2480.00000000
Company
Phoenix Contact GmbH & Co. KG
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

PHOENIX CONTACT GmbH & Go. KG Agent Authorization Company: PHOENIX CONTACT GmbH & Co. KG Address: Flachsmarkstr. 8 32825 Blomberg, Germany Product Name: Thermal Transfer Label Printer Model Number(s): THERMOMARK cO Product Description: Thermal Transfer Label Printer with Bluetooth function We authorize M|CO to act on our belhalf equipment. M Labs lnc., 575 Boulder Court, Pleasanton, California 94566, USA, on all matters concerning the certification of above named We declare that M|COM Labs lnc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. PHOENIX CONTACT GnrbH & Co. KG j"/."r Flachsmarktstr. I D-32825 Blomberg Date: 2O2OtOglOg Dipl.-lnq. IFH) Florian Din ger Signature: Name: Tiile: Company: Director Product Compliance PHOENIX CONTACT GmbH & Co. KG ¿h

Cover Letter(s)

PHOENIX CONTACT GmbH & Co. KG Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Dale:2020/09/03 Subject; Request for Confidentiality FCC lD: YG3-TMGO To Whom lt May Concern, Pursuant to the provisions of the Commission's rules Tille 47 Sections 50.457 and $0.45g, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. x X u Schematic Diagram Block Diagram Parts List ln additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR 52.803 and the importation rules in Tille 47 CFR 52.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos X lnternal Photos X User Manual fl for 45 days, pursuant to Public Notice DA O4-1705. OR I for 180 days pursuant to KDB 726920 DO1. It is our understanding that all measurement test reports, FCC lD labelformat and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, X Operational Description n Tune-up Procedure PHOEN|X CONTACT GmbH & Co. KG ;4=-c_¡ J,;;å;îi:ïîå Signature Name: Dipl.-lng. (FH) Florian Dinger Title: Director Product Compliance //¿

External Photos

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. Appendix I External Photographs MODEL NUMBER: THERMOMARK GO Page 2 of 5 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . . All View of EUT Front View of EUT-1 Page 3 of 5 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . . Back View of EUT-1 Top View of EUT Page 4 of 5 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . . Bottom View of EUT Left View of EUT-1 Page 5 of 5 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . . Right View of EUT

ID Label/Location Info

印刷颜色: 审核制图变更内容 图纸规格:A4 单 位:mm 比 例: 页 数: U L: 版本 内部参阅 严禁外传 文件编号: SHM-PM-07-13 制作日期 三维视图: 内部料号: 新制成 A2020.05.12 1:1 1/1 PP000273 田郴 是否排废: 覆 膜: 模具编号: 模切方式:半切 排列方式:1行1列 客户名称: 印刷材料: 开料宽度: 包装方式: 客户料号: 48 打印机 L07405 卷装 是 最小包装: 1500pcs/包 AJ221 N 背 胶: N X.±0.5mm X.X±0.2mm X.XX±0.1 mm 未标注公差尺寸: 93 42.0 R2.0

Internal Photos

Appendix II Internal Photographs MODEL NUMBER: THERMOMARK GO Page 2 of 16 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Open View of EUT Internal View of EUT-1 Page 3 of 16 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Internal View of EUT-2 Internal View of EUT-3 Page 4 of 16 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Internal View of EUT-4 Internal View of EUT-5 Page 5 of 16 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Internal View of EUT-6 Internal View of EUT-7 Page 6 of 16 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Internal View of EUT-8 Internal View of EUT-9 Page 7 of 16 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Internal View of EUT-10 Internal View of EUT-11 Page 8 of 16 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Internal View of EUT-12 Internal View of EUT-13 Page 9 of 16 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Internal View of EUT-14 Internal View of EUT-15 Page 10 of 16 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Internal View of EUT-16 Internal View of EUT-17 Page 11 of 16 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Internal View of EUT-18 Internal View of EUT-19 Page 12 of 16 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Internal View of EUT-20 Internal View of EUT-21 Page 13 of 16 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Internal View of EUT-22 Internal View of EUT-23 Page 14 of 16 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Adapter-1 Adapter-2 Page 15 of 16 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Adapter-3 Adapter-4 Page 16 of 16 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . RF Module & Antenna

RF Exposure Info

The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. This report does not imply that the product(s) has met the criteria for certification. FCC RF EXPOSURE REPORT For Thermal Transfer Label Printer MODEL NUMBER: THERMOMARK GO FCC ID: YG3-TM-GO IC ID: 4720B-TM-GO PROJECT NUMBER: 4789342611 REPORT NUMBER: 4789342611-2 ISSUE DATE: May. 09, 2020 Prepared for PHOENIX CONTACT GmbH & Co. KG Prepared by UL-CCIC COMPANY LIMITED No. 2, Chengwan Road, Suzhou Industrial Park, People’s Republic of China Tel: +86 512 6808 6400 Fax: +86 512 6808 4099 Website: www.ul.com REPORT No.: 4789342611-2 Page 2 of 6 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 3 2. TEST METHODOLOGY ..................................................................................................... 4 3. FACILITIES AND ACCREDITATION ................................................................................. 4 4. REQUIREMENT ................................................................................................................. 5 REPORT No.: 4789342611-2 Page 3 of 6 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: PHOENIX CONTACT GmbH & Co. KG Address: Flachsmarktstr. 8 32825 Blomberg, Germany Manufacturer Information Company Name: PHOENIX CONTACT GmbH & Co. KG Address: Flachsmarktstr. 8 32825 Blomberg, Germany Factory Information Company Name: VARICUT (SHANGHAI) ELECTRONICS COMPONENT Co., LTD. Address: No.655, Fengmao Rd, Malu Town, Jiading District, Shanghai, China EUT Description EUT Name: Thermal Transfer Label Printer Model: THERMOMARK GO Sample Status: Normal Sample Received Date: Mar. 30, 2020 Date of Tested: Apr. 23, 2019 ~ Apr 30, 2020 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC Guidelines for Human Exposure IEEE C95.1 Complies Prepared By: Reviewed By: Tom Tang Chris Zhong Engineer Project Associate Senior Project Engineer Authorized By: Scholl Zhang Laboratory Leader REPORT No.: 4789342611-2 Page 4 of 6 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.. 2. TEST METHODOLOGY The tests documented in this report were performed in accordance with KDB 447498 D01 General RF Exposure Guidance v06 and FCC Guidelines for Human Exposure IEEE C95.1. 3. FACILITIES AND ACCREDITATION Accreditation Certificate A2LA (Certificate No.: 4829.01) UL-CCIC COMPANY LIMITED has been assessed and proved to be in compliance with A2LA. FCC (FCC Designation No.: CN1247) UL-CCIC COMPANY LIMITED has been recognized to perform compliance testing on equipment subject to the Commission's Declaration of Conformity (DoC) and Certification rules. IC (IC Designation No.: 25056) UL-CCIC COMPANY LIMITED has been recognized to perform compliance testing on equipment subject to the Commission's Declaration of Conformity (DoC) and Certification rules. Note 1: All tests measurement facilities use to collect the measurement data are located at No. 2, Chengwan Road, Suzhou Industrial Park, Suzhou 215122, People’s Republic of China Note 2: For below 30MHz, lab had performed measurements at test anechoic chamber and comparing to measurements obtained on an open field site. These measurements below 30MHz had been correlated to measurements performed on an OATS. Note 3: The test anechoic chamber in UL-CCIC COMPANY LIMITED had been calibrated and compared to the open field sites and the test anechoic chamber is shown to be equivalent to or worst case from the open field site. REPORT No.: 4789342611-2 Page 5 of 6 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.. 4. REQUIREMENT LIMIT Limits for General Population/Uncontrolled Exposure Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Time |E| 2 , |H| 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f2)* 30 30-300 27.5 0.073 0.2 30 300-1500 -- -- f/150 30 1500-100,000 -- -- 1.0 30 Note 1: f = frequency in MHz, * means Plane-wave equivalent power density Note 2: General population/uncontrolled exposures apply in situations in which the general public may be exposed, or in which persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot exercise control over their exposure. Note 3: The limit value 1.0mW/cm 2 is available for this EUT. MPE CALCULATION METHOD S =PG/(4πR 2 ) where: S = power density (in appropriate units, e.g. mW/ cm2) P = power input to the antenna (in appropriate units, e.g., mW) (the measured power value see Report: F12124 Section 6.6) G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna (appropriate units, e.g., cm) REPORT No.: 4789342611-2 Page 6 of 6 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.. CALCULATED RESULTS Radio Frequency Radiation Exposure Evaluation BLE (Worst case) Max. Tune up Power Antenna Gain Power Density Limit Test Result (dBm) (mW) (dBi) (Numeric) (mW/cm2) (mW/cm2) -- 4.5 2.82 0.5 1.12 0.0006 1 Complies Note: the …

Text truncated - open the document above for the full version.

Test Report

The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. This report does not imply that the product(s) has met the criteria for certification. CFR 47 FCC PART 15 SUBPART C ISED RSS-247 ISSUE 2 CERTIFICATION TEST REPORT For Thermal Transfer Label Printer MODEL NUMBER: THERMOMARK GO FCC ID: YG3-TMGO IC: 4720B-TMGO PROJECT NUMBER: 4789342611 REPORT NUMBER: 4789342611-1 ISSUE DATE: May. 09, 2020 Prepared for PHOENIX CONTACT GmbH & Co. KG Prepared by UL-CCIC COMPANY LIMITED No. 2, Chengwan Road, Suzhou Industrial Park, People’s Republic of China Tel: +86 512 6808 6400 Fax: +86 512 6808 4099 Website: www.ul.com REPORT No.: 4789342611-1 Page 2 of 62 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. Revision History Rev. Issue Date Revisions Revised By V0 05/09/2020 Initial Issue REPORT No.: 4789342611-1 Page 3 of 62 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. Summary of Test Results Clause Test Items FCC/IC Rules Test Results 1 6db DTS Bandwidth and 99% Bandwidth FCC Part 15.247 (a) (2) RSS-247 Clause 5.2 (a) ISED RSS-Gen Clause 6.7 Pass 2 Peak Conducted Output Power FCC Part 15.247 (b) (3) RSS-247 Clause 5.4 (d) Pass 3 Power Spectral Density FCC Part 15.247 (e) RSS-247 Clause 5.2 (b) Pass 4 Conducted Bandedge and Spurious Emission FCC Part 15.247 (d) RSS-247 Clause 5.5 Pass 5 Radiated Bandedge and Spurious Emission FCC Part 15.247 (d) FCC Part 15.209 FCC Part 15.205 RSS-247 Clause 5.5 RSS-GEN Clause 8.9 Pass 6 Conducted Emission Test For AC Power Port FCC Part 15.207 RSS-GEN Clause 8.8 Pass 7 Antenna Requirement FCC Part 15.203 RSS-GEN Clause 6.8 Pass Remark: The measurement result for the sample received is <Pass> according to < ANSI C63.10-2013, FCC CFR 47 Part 2, FCC CFR 47 Part 15C> when <Accuracy Method> decision rule is applied. REPORT No.: 4789342611-1 Page 4 of 62 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 5 2. TEST METHODOLOGY ..................................................................................................... 6 3. FACILITIES AND ACCREDITATION ................................................................................. 6 4. CALIBRATION AND UNCERTAINTY ................................................................................ 7 4.1. MEASURING INSTRUMENT CALIBRATION .............................................................. 7 4.2. MEASUREMENT UNCERTAINTY ............................................................................... 7 5. EQUIPMENT UNDER TEST ............................................................................................... 8 5.1. DESCRIPTION OF EUT .............................................................................................. 8 5.2. MAXIMUM OUTPUT POWER...................................................................................... 8 5.3. CHANNEL LIST ........................................................................................................... 9 5.4. TEST CHANNEL CONFIGURATION ........................................................................... 9 5.5. THE WORSE CASE CONFIGURATIONS ................................................................... 9 5.6. DESCRIPTION OF AVAILABLE ANTENNAS .............................................................. 9 5.7. THE WORSE CASE CONFIGURATIONS ..................................................................10 5.8. DESCRIPTION OF TEST SETUP ...............................................................................11 6. MEASURING INSTRUMENT AND SOFTWARE USED ....................................................12 7. ANTENNA PORT TEST RESULTS ...................................................................................13 7.1. ON TIME AND DUTY CYCLE .....................................................................................13 7.2. 6 dB DTS BANDWIDTH AND 99% OCCUPIED BANDWIDTH ...................................15 7.3. PEAK CONDUCTED OUTPUT POWER .....................................................................20 7.4. POWER SPECTRAL DENSITY ..................................................................................23 7.5. CONDUCTED BANDEDGE AND SPURIOUS EMISSIONS ........................................26 8. RADIATED TEST RESULTS .............................................................................................35 8.1. RESTRICTED BANDEDGE ........................................................................................41 8.2. SPURIOUS EMISSIONS (1~18GHz) ..........................................................................46 8.3. SPURIOUS EMISSIONS (18~26GHz) ........................................................................52 8.4. SPURIOUS EMISSIONS (0.03 ~ 1 GHz) ....................................................................54 8.5. SPURIOUS EMISSIONS BELOW 30M .......................................................................56 9. AC POWER LINE CONDUCTED EMISSIONS ..................................................................59 10. ANTENNA REQUIREMENTS ........................................................................................62 REPORT No.: 4789342611-1 Page 5 of 62 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. 1. ATTESTATION OF TEST RESULTS Applicant Info…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 4 Appendix III Setup Photographs MODEL NUMBER: THERMOMARK GO Page 2 of 4 RADIATED RF MEASUREMENT SETUP (9KHz ~ 30 MHz) RADIATED RF MEASUREMENT SETUP (30MHz ~ 1 GHz) Page 3 of 4 RADIATED RF MEASUREMENT SETUP (ABOVE 1 GHz- X axis) RADIATED RF MEASUREMENT SETUP (ABOVE 1 GHz- Y axis) Page 4 of 4 RADIATED RF MEASUREMENT SETUP (ABOVE 1 GHz- Z axis) POWERLINE CONDUCTED EMISSIONS MEASUREMENT SETUP

Contact Information

Applicant

Dinger Florian(Director Product Compliance)
[email protected]+49-5235312000Fax: +495235312999

Technical Contact

PHOENIX CONTACT GmbH & Co. KG
[email protected]

Germany

Test Firm

Guangdong Dongdian Testing Service Co., Ltd.Mr. Jamy Yu
[email protected]+86-0769-89201646

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.36 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Phoenix Contact GmbH & Co. KG

Ultra Short Range Communication Device (USRD) - FCC ID YG32000R - Phoenix Contact GmbH & Co. KG
YG32000R

Ultra Short Range Communication Device (USRD)

May 03, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless Power Transfer - FCC ID YG3300R - Phoenix Contact GmbH & Co. KG
YG3300R

Wireless Power Transfer

May 03, 2026

Equipment Class

JAB - Part 15 Class B Digital Device
Wireless Power Transfer - FCC ID YG3300B - Phoenix Contact GmbH & Co. KG
YG3300B

Wireless Power Transfer

May 03, 2026

Equipment Class

8CC - Part 18 Consumer Device
Wireless Power Transfer - FCC ID YG3200R - Phoenix Contact GmbH & Co. KG
YG3200R

Wireless Power Transfer

May 03, 2026

Equipment Class

JAB - Part 15 Class B Digital Device
Wireless Power Transfer - FCC ID YG3200B - Phoenix Contact GmbH & Co. KG
YG3200B

Wireless Power Transfer

May 03, 2026

Equipment Class

8CC - Part 18 Consumer Device