Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1 Description NearFi coupler for contactless power and data transmission NEARFI... © Phoenix Contact Data sheet The NearFi coupler transmits power and real-time Ether- net data contactlessly over an air gap in the centimeter range. For contactless transmission, you will need at least two devices: a base and one or more remote couplers. The base coupler transmits the energy inductively to the remote coupler. Ethernet transmission is bidirectional between the base and the remote. In maintenance-intensive applications, such as tool changes on robots, this enables wear-prone connections to be replaced easily and minimizes downtime costs. The base and remote couplers are both available in three versions: âPower and data transmission (NEARFI PD...) âOnly power transmission (NEARFI P...) âOnly data transmission (NEARFI D...) Features âContactless - and therefore no wear and no mainte- nance âProtocol-independent, latency-free Ethernet real- time communication with 100 Mbps (full duplex) âHigh power in a compact housing âAll-round visible diagnostics with light ring on the housing âHigh degree of mounting freedom with flexible prox- imity options âPlug and Play - as easy as a plug âDegree of protection IP65 âProtocol-transparent transmission of all standard Ethernet protocols Observe this note Make sure you always use the latest documentation. It can be downloaded at: phoenixcontact.com/product/1234224 This document is valid for the products listed in the âOrdering dataâ chapter. 109708_en_04 2024-07-25 NEARFI... 109708_en_04Phoenix Contact2 / 39 2 Table of contents 1Description.................................................................................................................................1 2Table of contents.......................................................................................................................2 3Ordering data.............................................................................................................................3 4Technical data............................................................................................................................7 5Safety regulations and installation notes...............................................................................13 6Functional principle................................................................................................................19 7Transport and unpacking........................................................................................................20 8Product description.................................................................................................................20 9Installation..............................................................................................................................26 10Connecting the cables.............................................................................................................31 11Maintenance and disposal......................................................................................................33 12Troubleshooting......................................................................................................................34 13Derating...................................................................................................................................37 NEARFI... 109708_en_04Phoenix Contact3 / 39 DescriptionTypeItem no.Pcs./Pkt. NearFi, base coupler for contactless power and real- time Ethernet transmission in the centimeter range, 24 V DC, 2 A, 100 Mbps, full duplex, M12 connection technology, IP65 type of protection. A remote coupler is required for operation. NEARFI PD 2A ETH B12342241 NearFi, remote coupler for contactless power and real- time Ethernet transmission in the centimeter range, 24 V DC, 2 A, 100 Mbps, full duplex, M12 connection technology, IP65 type of protection. A base coupler is re- quired for operation. NEARFI PD 2A ETH R12342251 NearFi, base coupler for contactless power transmission in the centimeter range, 24 V DC, 2 A, M12 connection technology, IP65 type of protection. A remote coupler is required for operation. NEARFI P 2A B12342261 NearFi, remote coupler for contactless power transmis- sion in the centimeter range, 24 V DC, 2 A, M12 connec- tion technology, IP65 type of protection. A base coupler is required for operation. NEARFI P 2A R12342291 NearFi, base coupler for contactless real-time Ethernet transmission in the centimeter range, 100 Mbps, full du- plex, M12 connection technology, IP65 type of protec- tion. A remote coupler is required for operation. NEARFI D ETH B12342321 NearFi, remote coupler for contactless real-time Ether- net transmission in the centimeter range, 100 Mbps, full duplex, M12 connection technology, IP65 type of pro- tection. A base coupler is required for operation. NEARFI D ETH R12342341 3 Ordering data AccessoriesTypeItem no.Pcs./Pkt. Sensor/actuator cable, 5-position, PUR, black-gray RAL 7021, free cable end, on Socket straight M12 SPEEDCON, coding: A, cable length: 2 m SAC-5P- 2,0-186/FS SCO15183681 Sensor/actuator cable, 5-position, PUR, black-gray RAL 7021, free cable end, on Socket straight M12 SPEEDCON, coding: A, cable length: 5 m SAC-5P- 5,0-186/FS SCO15183711 Sensor/actuator cable, 5-position, PUR, black-gray RAL 7021, free cable end, on Socket straight M12 SPEEDCON, coding: A, cable length: 10 m SAC-5P-10,0-186/FS SCO15183841 Sensor/actuator cable, 5-position, PUR, black-gray RAL 7021, free cable end, on Socket straight M12 SPEEDCON, coding: A, cable length: 15 m SAC-5P-15,0-186/FS SCO15183971 Sensor/actuator cable, 5-position, PUR, black-gray RAL 7021, Plug straight M12 SPEEDCON, coding: A, on Socket straight M12 SPEEDCON, coding: A, cable length: 1 m SAC-5P-MS/ 1,0-186/FS SCO15184231 NEARFI... 109708_en_04Phoenix Contact4 / 39 Sensor/actuator cable, 5-position, PUR, black-gray RAL 7021, Plug straight M12 SPEEDCON, coding: A, on Socket straight M12 SPEEDCON, coding: A, âŠ
Text truncated - open the document above for the full version.
Phoenix Contact GmbH & Co. KG FlachsmarktstraĂe 8, 32825 Blomberg, Germany Fax +49-(0)5235-341200, Phone +49-(0)5235-300 phoenixcontact.com DE Einbauanweisung fĂŒr die Elektrofachkraft EN Installation notes for electrically skilled persons FR Instructions d'installation pour l'Ă©lectricien qualifiĂ© 2022-10-11 © Phoenix Contact 2022 Induktive Koppler 1 Sicherheitshinweise âąDie Installation, Bedienung und Wartung ist von elektrotechnisch qualifiziertem Fachpersonal durchzufĂŒh- ren. Befolgen Sie die beschriebenen Installationsanweisungen. âąHalten Sie die fĂŒr das Errichten und Betreiben geltenden Bestimmungen und Sicherheitsvorschriften (auch nationale Sicherheitsvorschriften) sowie die allgemein anerkannten Regeln der Technik ein. âąBeachten Sie die Sicherheitsinformationen, Bedingungen und Einsatzgrenzen in der Produktdokumentati- on. Halten Sie diese ein. âąDie Montage und elektrische Installation muss dem Stand der Technik entsprechen. âąĂffnen oder VerĂ€ndern des GerĂ€ts ist nicht zulĂ€ssig. Reparieren Sie das GerĂ€t nicht selbst, sondern erset- zen Sie es durch ein gleichwertiges GerĂ€t. Reparaturen darf nur der Hersteller vornehmen. Der Hersteller haftet nicht fĂŒr SchĂ€den aus Zuwiderhandlung. Installation âąDas GerĂ€t ist ausschlieĂlich fĂŒr den Betrieb mit Sicherheitskleinspannung (SELV/PELV) einer "Elektrischen Energiequelle" der Klasse ES1 nach EN/IEC 62368-1 und VDE 0868-1 ausgelegt. Das GerĂ€t darf nur an GerĂ€te angeschlossen werden, die die Bedingungen der Klasse ES1 nach EN/IEC 62368-1 erfĂŒllen. âąDimensionieren und sichern Sie die primĂ€r- und sekundĂ€rseitige Verdrahtung ausreichend. âąBeachten Sie die Spannungsverluste auf der Leitung. Die GerĂ€te können bei Unterspannung nicht mehr funktionieren. âąDie Anschlussparameter wie z. B. die erforderlichen AbisolierlĂ€ngen fĂŒr die Verdrahtung entnehmen Sie den Installationshinweisen zum jeweiligen feldseitigen Rundsteckverbinder. âąDie Parallelschaltung von mehreren Remote-Kopplern ist nicht zulĂ€ssig. Einsatzort âąDas DruckgussgehĂ€use und die gerĂ€teseitigen Rundsteckverbinder erfĂŒllen die Schutzart IP65. âąVerschlieĂen Sie ungenutzte Anschlussbuchsen mit Schutzkappen, um die Schutzart IP65 sicherzustellen. âąLegen Sie den Einsatzort so aus, dass die VerlustwĂ€rme abgeleitet werden kann. Montieren Sie das Druck- gussgehĂ€use an eine Metallplatte, KĂŒhlkörper oder Ă€hnliches wĂ€rmeleitendes Material. âąDurch Induktionseffekte an den Energiespulen kann sich das GerĂ€t erhitzen. Halten Sie einen Mindest- abstand zu metallischen GegenstĂ€nden von 5 mm ein. In einem Abstand von 300 mm werden die Grenzwerte fĂŒr die elektrische und magnetische FeldstĂ€rke erfĂŒllt. Basierend auf der EU-Ratsempfehlung 1999/519/EG gilt dieser Abstand nach EN 62311 als Basisgrenzwert oder Referenzwert fĂŒr die Sicherheit von Personen in elektromagnetischen Feldern. FĂŒr Personen mit aktiven Körperhilfsmitteln (wie z. B. Herzschrittmacher) gelten unter UmstĂ€nden weitere (betriebliche) Grenzwerte. 2 Kurzbeschreibung (ï) Die NEARFI-P-Koppler ĂŒbertragen kontaktlos Energie ĂŒber einen Luftspalt im Zentimeterbereich (24 V DC, 2 A). Der Base-Koppler ĂŒbertrĂ€gt die Energie zum Remote-Koppler. 2.1 LED-Ring Befolgen Sie diese Anweisungen fĂŒr einen sicheren und ordnungsgemĂ€Ăen Gebrauch. Bewahren Sie die Anweisungen zum spĂ€teren Nachschlagen auf. Weitere Informationen finden Sie im zugehörigen Datenblatt unter phoenixcontact.net/products. VORSICHT: HeiĂe OberflĂ€che Das GehĂ€use der GerĂ€te kann heiĂ werden. Nach dem Abschalten der Versorgungsspannung kann das GerĂ€t weiterhin heiĂ sein. â Stellen Sie ausreichenden BerĂŒhrschutz sicher. â Verhindern Sie unbeabsichtigtes BerĂŒhren durch mechanische Absperrung oder durch gut sichtbare Warnhinweise. â WĂ€hlen Sie den Einsatzort so, dass keine metallischen GegenstĂ€nde in den Luftspalt zwischen Base und Remote gelangen können. WARNUNG: Elektromagnetische Felder Bei Montage und Betrieb entstehen um das GerĂ€t herum elektromagnetische Felder. â Halten Sie mindestens 300 mm Abstand von den GerĂ€ten. 1DruckgussgehĂ€use 2LED-Ring 3GehĂ€useoberteil (Energiespule mittig zentriert hinter dem Logo) 4Befestigungsmöglichkeit mit Innengewinde (2x M6, Tiefe = 7 mm) 5GehĂ€useunterseite: DIP-Schalter, QR-Code, weitere Befestigungsmöglichkeiten mit Innengewinde (4x M6, Tiefe = 7 mm) 6Befestigungsflansch mit Montagelöchern (Ă = 5,5 mm) 7M12-Rundsteckverbinder fĂŒr Eingangsspannung (Base-Koppler) oder Ausgangsspannung (Remote- Koppler) 8Funktionserdanschluss mit Innengewinde (1x M4, Tiefe = 5 mm) LED-RingStatusBaseRemote GrĂŒnEinBase und Remote gekoppelt, Ăbertragung aktiv BlinktGerĂ€t betriebsbereit, keine Ăbertra- gung, Luftspalt/Versatz zu groĂ - Remote-Spannungsausgang Ăber- last/Kurzschluss AusBase nicht betriebsbereit oder aus- geschaltet ĂŒber Steuereingang (DI PWR_CTRL) Remote nicht gekoppelt RotEinKritischer Fehler, interne Temperatur zu hoch, externe Versorgungsspan- nung gravierend auĂerhalb des Nennbereichs - Coupleur inductif 1 Consignes de sĂ©curitĂ© âąLâinstallation, lâutilisation et la maintenance doivent ĂȘtre confiĂ©es Ă un personnel spĂ©cialisĂ© dĂ»ment qualifiĂ© en Ă©lectrotechnique. Respecter les instructions d'installation. âąLors de la mise en place et de l'utilisation, respectez les dispositions et les consignes de sĂ©curitĂ© en vigueur (normes de sĂ©curitĂ© nationales comprises) ainsi que les rĂšgles relatives Ă la technique gĂ©nĂ©ralement recon- nues. âąObservez les informations relatives Ă la sĂ©curitĂ©, les conditions et limites d'utilisation comprises dans la documentation du produit. Respectez-les. âąLe montage et l'installation Ă©lectrique doivent correspondre Ă l'Ă©tat de la technique. âąIl est interdit d'ouvrir et de modifier l'appareil. L'appareil ne peut ĂȘtre rĂ©parĂ© par vos soins, mais il peut ĂȘtre remplacĂ© par un appareil Ă©quivalent. Seul le fabricant est autorisĂ© Ă effectuer des rĂ©parations. Le fabricant ne peut ĂȘtre tenu pour responsable des dommages rĂ©sultant d'infractions Ă ces consignes. Installation âąL'appareil est conçu pour ĂȘtre utilisĂ© exclusivement avec une trĂšs basse tensionâŠ
Text truncated - open the document above for the full version.
Phoenix Contact GmbH & Co.KG Flachsmarktstr. 8 D-32825 Blomberg Germany Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 2L046 USA March 30,2023 Attestation Statement according to 2.91l(dX5)(i) and 2.911(dX5XÂĄi) FCC lD: YG3P2AB TO WHOM IT MAY CONCERN: Hereby we certify that the equipment for which authorization is sought is not "covered" equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Further we certify that, as of the date of the filing of the application, Phoenix Contact GmbH & Co.KG is not identified on the Covered List as an entity producing "covered" equipment. Sincerely, PHOENIX CONTACT GmbH & Co. KG Flachsmarktstr. I D-32825 Blomberg ;" t/. (signature & company stomp) Name / Title: Dinger Florian Company: Phoenix Contact GmbH & Co. KG Address: FlachsmarktstraĂe 8 D-32825 Blomberg Phone: +4952353-43748 Fax: +4952353-41470 E-Mail: [email protected] ,1/,Âż
External photos of NEARFI P 2A B Examiner:Wolfgang KASALOWSKYRevision: 0 Date of issue: 02.06.2023Order Number: 22-110997page 1 of 6 EUT â Top view External photos of NEARFI P 2A B Examiner:Wolfgang KASALOWSKYRevision: 0 Date of issue: 02.06.2023Order Number: 22-110997page 2 of 6 EUT â Bottom view External photos of NEARFI P 2A B Examiner:Wolfgang KASALOWSKYRevision: 0 Date of issue: 02.06.2023Order Number: 22-110997page 3 of 6 EUT â Connector side External photos of NEARFI P 2A B Examiner:Wolfgang KASALOWSKYRevision: 0 Date of issue: 02.06.2023Order Number: 22-110997page 4 of 6 EUT â Mounting side External photos of NEARFI P 2A B Examiner:Wolfgang KASALOWSKYRevision: 0 Date of issue: 02.06.2023Order Number: 22-110997page 5 of 6 EUT â Side view 1 External photos of NEARFI P 2A B Examiner:Wolfgang KASALOWSKYRevision: 0 Date of issue: 02.06.2023Order Number: 22-110997page 6 of 6 EUT â Side view 2
12
PHOENIX CONTACT GmbH & Co. KG âą FlachsmarktstraĂe 8 âą 32825 Blomberg âą Germany1/3 Phone: +49-(0) 5235-3-00 âą Fax: +49-(0) 5235-3-4 12 00 âą www.phoenixcontact.com 1Internal photos transmitter parts NEARFI P_2A_B 1.1Part for Power transfer Energy top RF section for energy transfer PHOENIX CONTACT GmbH & Co. KG âą FlachsmarktstraĂe 8 âą 32825 Blomberg âą Germany2/3 Phone: +49-(0) 5235-3-00 âą Fax: +49-(0) 5235-3-4 12 00 âą www.phoenixcontact.com PCB Base bottom RF section for energy transfer PHOENIX CONTACT GmbH & Co. KG âą FlachsmarktstraĂe 8 âą 32825 Blomberg âą Germany3/3 Phone: +49-(0) 5235-3-00 âą Fax: +49-(0) 5235-3-4 12 00 âą www.phoenixcontact.com Lid with potting Power Coil for energy transfer
Internal photos of NEARFI P 2A B Examiner:Wolfgang KASALOWSKYRevision: 0 Date of issue: 02.06.2023Order Number: 22-110997page 1 of 8 NEARFI P 2A B, internal view 1, housing opened Internal photos of NEARFI P 2A B Examiner:Wolfgang KASALOWSKYRevision: 0 Date of issue: 02.06.2023Order Number: 22-110997page 2 of 8 NEARFI P 2A B, internal view 2, shielding removed Internal photos of NEARFI P 2A B Examiner:Wolfgang KASALOWSKYRevision: 0 Date of issue: 02.06.2023Order Number: 22-110997page 3 of 8 NEARFI P 2A B, internal view 3, data PCB removed Internal photos of NEARFI P 2A B Examiner:Wolfgang KASALOWSKYRevision: 0 Date of issue: 02.06.2023Order Number: 22-110997page 4 of 8 NEARFI P 2A B, internal view 4, energy PCB removed Internal photos of NEARFI P 2A B Examiner:Wolfgang KASALOWSKYRevision: 0 Date of issue: 02.06.2023Order Number: 22-110997page 5 of 8 NEARFI P 2A B, data PCB, top view Internal photos of NEARFI P 2A B Examiner:Wolfgang KASALOWSKYRevision: 0 Date of issue: 02.06.2023Order Number: 22-110997page 6 of 8 NEARFI P 2A B, data PCB, bottom view Internal photos of NEARFI P 2A B Examiner:Wolfgang KASALOWSKYRevision: 0 Date of issue: 02.06.2023Order Number: 22-110997page 7 of 8 NEARFI P 2A B, interface PCB, top view Internal photos of NEARFI P 2A B Examiner:Wolfgang KASALOWSKYRevision: 0 Date of issue: 02.06.2023Order Number: 22-110997page 8 of 8 NEARFI P 2A B, interface PCB, bottom view
Königswinkel 10 32825 Blomberg, Germany Phone: +49 (0) 52 35 / 95 00-0 Fax: +49 (0) 52 35 / 95 00-10 [email protected] www.phoenix-testlab.de Test Report Report Number: F220997E4, 2 nd version Equipment under Test (EUT): NEARFI P 2A B Applicant: PHOENIX CONTACT Electronics GmbH Manufacturer: PHOENIX CONTACT GmbH & Co.KG Examiner: Thomas KĂHN Report Number: F220997E4, 2 nd version Date of Issue: 07.08.2024 Order Number: 22-110997 Page 2 of 18 References [1] CFR 47 Rule part 1 Practice and Procedure [2] CFR 47 Rule part 2 Frequency Allocations and Radio Treaty Matters; General Rules and Regulations [3] KDB 447498 D04 Interim General RF Exposure Guidance v01 [4] KDB 680106 D01 Wireless Power Transfer v04 Test Result The requirements of the tests performed as shown in the results (clause 3) were fulfilled by the equipment under test. The complete test results are presented in the following. âPassedâ indicates that the equipment under test conforms with the relevant limits of the testing standard without taking any measurement uncertainty into account. However, the measurement uncertainty is calculated and shown in this test report. T h i s t e s t r e p o r t i s o n l y v a l i d i n i t s o r i g i n a l f o r m. Any reproduction of its contents in extracts without written permission of the accredited test laboratory PHOENIX TESTLAB GmbH is prohibited. The test results herein refer only to the tested sample. PHOENIX TESTLAB GmbH is not responsible for any generalisations or conclusions drawn from these test results concerning further samples. Any modification of the tested samples is prohibited and leads to the invalidity of this test report. Each page necessarily contains the PHOENIX TESTLAB Logo and the TEST REPORT NUMBER. Tested and written by: Signature Reviewed and approved by: Signature Examiner: Thomas KĂHN Report Number: F220997E4, 2 nd version Date of Issue: 07.08.2024 Order Number: 22-110997 Page 3 of 18 Contents: Page Identification ................................................................................................................................. 4 1.1 Applicant ................................................................................................................................................... 4 1.2 Manufacturer ............................................................................................................................................ 4 1.3 Test Laboratory ........................................................................................................................................ 4 1.4 EUT (Equipment under Test) ................................................................................................................... 5 1.5 Technical data of equipment .................................................................................................................... 5 1.6 Dates ........................................................................................................................................................ 6 Evaluation method ........................................................................................................................ 7 2.1 RF exposure test exemptions for single sources ..................................................................................... 7 2.1.1 General Exemption CFR 47 §1.1307(b)(3)(i)(A) ............................................................................. 7 2.1.2 SAR Based Exemption CFR 47 §1.1307(b)(3)(i)(B) ........................................................................ 7 2.1.3 MPE Based Exemption CFR 47 §1.1307(b)(3)(i)(C) ....................................................................... 7 2.1.4 Stand alone MPE evaluation limits .................................................................................................. 8 2.2 RF exposure test exemptions for simultaneous transmission sources .................................................... 9 2.2.1 1 mW Test Exemption for simultaneous transmission sources ....................................................... 9 2.2.2 Simultaneous transmission SAR based and MPE based test exemptions ..................................... 9 2.2.3 Test exemption based on the SAR to Peak Location Separation Ratio ........................................ 10 Results of evaluation ................................................................................................................... 11 3.1 Used evaluation methods ....................................................................................................................... 11 3.2 Evaluation Distance ................................................................................................................................ 11 3.3 Measurement of E field strength from the source without client ............................................................ 12 3.4 Measurement of H field strength from the source without client ............................................................ 13 3.5 Measurement of E field strength from the source with client at minimum distance ............................... 14 3.6 Measurement of H field strength from source with client at minimum distance ..................................... 15 3.7 Measurement of E field strength from source with client at maximum distance .................................... 16 3.8 Measurement of H field strength from the source with client at maximum distance .............................. 17 Conclusion .................................................................................................................................. 18 Test Equipment used for Tests ................................................................................................... 18 Measurement uncertainties ......................................................................................................... 18 Report History ......................................âŠ
Text truncated - open the document above for the full version.
Königswinkel 10 32825 Blomberg, Germany Phone: +49 (0) 52 35 / 95 00-0 Fax: +49 (0) 52 35 / 95 00-10 [email protected] www.phoenix-testlab.de Test Report Report Number: F220997E2, 2 nd version Equipment under Test (EUT): NEARFI P 2A B Applicant: PHOENIX CONTACT Electronics GmbH Manufacturer: PHOENIX CONTACT GmbH & Co.KG Examiner: Wolfgang KASALOWSKY Report Number: F220997E2, 2 nd version Date of Issue: 22.11.2023 Order Number: 22-110997 Page 2 of 31 References [1] FCC/OST MP-5 (1986) FCC methods of measurement of radio noise emissions from industrial, scientific and medical equipment. [2] FCC 47 CFR Part 2 General Rules and Regulations [3] FCC 47 CFR Part 18 INDUSTRIAL, SCIENTIFIC, AND MEDICAL EQUIPMENT [4] RSS-216 Issue 2 (January 2016) Amendment 1 (September 2020) Wireless Power Transfer Devices [5] RSS-Gen Issue 5 (March 2019) Amendment 1 General Requirements for Compliance of Radio Apparatus [6] ICES-001 Issue 5 (July 2020) Licence-exempt Radio Apparatus (All Frequency Bands): Category I Equipment [7] CSA CISPR 11:19 Industrial, scientific and medical equipment â Radio-frequency disturbance characteristics â Limits and methods of measurement (IEC CISPR 11:2015+A1:2016, MOD) Examiner: Wolfgang KASALOWSKY Report Number: F220997E2, 2 nd version Date of Issue: 22.11.2023 Order Number: 22-110997 Page 3 of 31 Test Result The requirements of the tests performed as shown in the overview (clause 4) were fulfilled by the equipment under test. The complete test results are presented in the following. âPassedâ indicates that the equipment under test conforms with the relevant limits of the testing standard without taking any measurement uncertainty into account. However, the measurement uncertainty is calculated and shown in this test report. T h i s t e s t r e p o r t i s o n l y v a l i d i n i t s o r i g i n a l f o r m. Any reproduction of its contents in extracts without written permission of the accredited test laboratory PHOENIX TESTLAB GmbH is prohibited. The test results herein refer only to the tested sample. PHOENIX TESTLAB GmbH is not responsible for any generalisations or conclusions drawn from these test results concerning further samples. Any modification of the tested samples is prohibited and leads to the invalidity of this test report. Each page necessarily contains the PHOENIX TESTLAB Logo and the TEST REPORT NUMBER. Tested by: OBO Signature Written by: Signature Reviewed and approved by: Signature Examiner: Wolfgang KASALOWSKY Report Number: F220997E2, 2 nd version Date of Issue: 22.11.2023 Order Number: 22-110997 Page 4 of 31 Contents: Page Identification ................................................................................................................................. 5 1.1 Manufacturer ............................................................................................................................................ 5 1.2 Test Laboratory ........................................................................................................................................ 5 1.3 EUT (Equipment under Test) ................................................................................................................... 6 1.4 Technical Data of Equipment ................................................................................................................... 6 1.5 Dates ........................................................................................................................................................ 7 Operational States ........................................................................................................................ 7 Additional Information ................................................................................................................... 7 Overview ....................................................................................................................................... 8 Results.......................................................................................................................................... 9 5.1 Test setups ............................................................................................................................................... 9 5.1.1 Radiated: Test fixture ...................................................................................................................... 9 5.1.2 Radiated: 9 kHz to 30 MHz .............................................................................................................. 9 5.1.2.1 Preliminary measurement 9 kHz to 30 MHz ........................................................................... 9 5.1.2.2 Final measurement 9 kHz to 30 MHz ................................................................................... 11 5.1.3 Preliminary and final measurement (30 MHz to 1 GHz) ................................................................ 12 5.1.4 Conducted emission: AC power line ............................................................................................. 13 5.1.5 Test setup (99 % bandwidth) ......................................................................................................... 14 5.1.1 Test method (99 % bandwidth) ...................................................................................................... 14 5.1.2 Test results (99 % bandwidth) ....................................................................................................... 15 5.2 AC power line conducted emissions ...................................................................................................... 17 5.2.1 Test setup (AC power line conducted emissions) ......................................................................... 17 5.2.2 Test method (AC power line conducted emissions) ...................................................................... 17 5.2.3 Results of conducted emission measurement on AC mains ..................âŠ
Text truncated - open the document above for the full version.
Annex A: Test setup photos Examiner:Wolfgang KASALOWSKYReport Number: F220997E2 Date of issue: 02.06.2023Order Number: 22-110997page 1 of 8 Test setup - Radiated emission (semi anechoic chamber) â base (EUT) and remote (client) unit Annex A: Test setup photos Examiner:Wolfgang KASALOWSKYReport Number: F220997E2 Date of issue: 02.06.2023Order Number: 22-110997page 2 of 8 Test setup - Radiated emission (semi anechoic chamber) â Base (EUT) unit Annex A: Test setup photos Examiner:Wolfgang KASALOWSKYReport Number: F220997E2 Date of issue: 02.06.2023Order Number: 22-110997page 3 of 8 Test setup - Radiated emission (semi anechoic chamber) 30 MHz â 1000 MHz Annex A: Test setup photos Examiner:Wolfgang KASALOWSKYReport Number: F220997E2 Date of issue: 02.06.2023Order Number: 22-110997page 4 of 8 Test setup - Radiated emission (semi anechoic chamber) Pre test 9 kHz â 30 MHz Annex A: Test setup photos Examiner:Wolfgang KASALOWSKYReport Number: F220997E2 Date of issue: 02.06.2023Order Number: 22-110997page 5 of 8 Test setup - Radiated emission (Outdoor test site) Annex A: Test setup photos Examiner:Wolfgang KASALOWSKYReport Number: F220997E2 Date of issue: 02.06.2023Order Number: 22-110997page 6 of 8 Test setup â Conducted emissions on power supply lines - base unit (EUT) Annex A: Test setup photos Examiner:Wolfgang KASALOWSKYReport Number: F220997E2 Date of issue: 02.06.2023Order Number: 22-110997page 7 of 8 Test setup â Conducted emissions on power supply lines - base (EUT) and remote (client) unit Annex A: Test setup photos Examiner:Wolfgang KASALOWSKYReport Number: F220997E2 Date of issue: 02.06.2023Order Number: 22-110997page 8 of 8 Test setup â 99% bandwidth (Test fixture) â base (EUT) and remote (client) unit
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.124 MHz - 0.124 MHz | - |

Ultra Short Range Communication Device (USRD)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless Power Transfer
Equipment Class
JAB - Part 15 Class B Digital Device
Wireless Power Transfer
Equipment Class
8CC - Part 18 Consumer Device
Wireless Power Transfer
Equipment Class
JAB - Part 15 Class B Digital Device
Wireless Power Transfer
Equipment Class
8CC - Part 18 Consumer Device