Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1 G50 Plus USER MANUAL FCC ID:YHLBLUG50PS 2 Table of Contents Safety Information .................................................................................................... 4 Appearance and Key Function ................................................................................ 7 Introduction .............................................................................................................. 10 Call Functions ......................................................................................................... 12 Notifications Bar ...................................................................................................... 14 Contacts ................................................................................................................... 16 Messaging ............................................................................................................... 18 Bluetooth & Wi-Fi .................................................................................................... 19 3 Downloads ................................................................................ 错误!未定义书签。 Opera Mini ................................................................................. 错误!未定义书签。 Gmail ........................................................................................................................ 23 Play Store ................................................................................................................ 24 Camera .................................................................................................................... 25 Music ........................................................................................................................ 28 FM Radio ................................................................................................................. 30 Sound Recorder ...................................................................................................... 31 File Manager ........................................................................................................... 33 Calendar .................................................................................................................. 34 Alarm Clock ............................................................................................................. 35 Settings .................................................................................................................... 36 4 Storage ..................................................................................................................... 41 Troubleshooting ...................................................................................................... 42 Safety Information Please carefully read the terms below: Use Safely Do not use the phone in situations where it might cause danger. Transportation Safety Please observe all transportation laws and regulations. Please drive with both hands on the wheel. PLEASE DRIVE RESPONSIBLY - DO NOT TEXT AND DRIVE Hospital Safety Please follow hospital rules and limitations. Please turn off your mobile phone when near medical instruments. Airport Safety Remember to follow all airport and flight safety regulations. 5 Please do not use your phone during flight. Chemical Warning Do not use your mobile phone around fuels or chemicals. Temperature Warning Do not subject your phone to extreme temperature conditions. Water Hazard Your phone is not waterproof. Keep your phone away from water or liquid to avoid damage. Emergency Calls Make sure your mobile phone is switched on and in a service area. In home screen, tap the phone key and dial the emergency number. Accessories and Batteries Use only Blu authorized batteries and accessories. Information Backup Remember to keep a written record of all important information. Battery Safety and Precautions - For better performance and longer battery life, it is recommended that you charge the battery fully before using the mobile phone for the first time. 6 - The optimum performance of a new battery is typically achieved after two or three complete charge cycles. Note: Keep in mind that continuous overcharging will affect long term battery life. - While charging, keep the mobile phone out the reach of children. - Store the battery in a cool and dry place away from direct sunlight and water. - Do not expose batteries to extreme temperatures (below -8°C (18°F) or above 43°C (110°F). - Immediately stop using the battery if it produces an odor, cracks and leaks, overheats, distorts or has any other type of physical damage. - Avoid using the charger near or around liquids. If the charger comes in contact with water or any liquids, immediately unplug it from the outlet to reduce the risk of overheating, charger malfunction, electric shock or fire. Warning: Please be careful with the disposal of used batteries. Do not throw away batteries with daily waste. Please follow local environmental laws and guidelines for proper waste disposal. Cleaning and Maintenance - Avoid using the handset and accessories in excessively moist areas to avoid malfunction. - Use a soft, dry cloth to clean the handset, battery and charger. - Do not use alcohol, thinner, benzene or any other solvent to clean the handset. 7 Appearance and Key Function 8 Volume Power Back Home Menu Front Camera 9 Rear Camera Flash Speaker Fingerprint sensor 10 Introduction Installation of the SIM Card Warning: Please keep the SIM card out of the reach of children. The SIM card and its contact are easily damaged due to scratching or bending. Please use caution when carrying, installing or taking out the SIM card. NB: Please contact your cellular phone service provider directly to obtain your SIM card. To insert SIM card: 1. Remove the card slot. Insert the SIM card. 2. Insert the SD card. (For additional storage capacity) 3.Insert card slot, and power on phone. 11 Slot 2 & Memory card Slot 1 12 Power …
Text truncated - open the document above for the full version.
Date: 2020/04/20 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 Re: BLU Products, Inc. FCC ID: YHLBLUG50PS Confidentiality Request Gentlemen: This letter is to comply with 47 CFR 0.457 and 0.459 pertaining to confidentiality material. BLU Products, Inc. requests that the following documents regarding this submission for FCC ID: Y HLBLUG50PS be kept confidential: Exhibit Type File Name Block Diagram Block Diagram.pdf Schematics Schematic.pdf Operational Description Operational description.pdf Part list BOM.pdf T hose documents contain detailed system and equipment description and related information about the product which BLU Products, Inc. considers to be confidential proprietary, a custom design and, otherwise, not releasable to the general public. Since this design is a basis form which future technological products will evolve, BLU Products, Inc. considers this information would be of benefit to its competitors, and that the disclosure of the information in these documents would give competitors an unfair advantage in the market. Yours Sincerely, Contact name: Wei Zeng Title: Senior Manager Tel: 3057157171 Email: [email protected] Company name: BLU Products, Inc.
BLU Products, Inc. Date: 2020/04/20 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 To whom it may concern, T he BLU Products, Inc., the undersigned, hereby authorizes Mrs. Wendy Zhan from Shenzhen Moriah Communications Technology Co., Ltd., to act on the behalf of the BLU Products, Inc. solely in matters relating to the application for an FCC equipment authorization for FCC ID: YHLBLUG50PS including the signing of documents in connection with this Application. Necessary acts carried out Shenzhen Moriah Communications Technology Co., Ltd. on our behalf of the BLU Products, Inc. in connection with the Application shall have the same effect as acts of the BLU Products, Inc .. BLU Products, Inc. also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. T hank you for your attention to this matter. Yours Sincerely, Signatory: Contact name: Wei Zeng Ti tle: Senior Manager Tel: 3057157171 Email: [email protected] Company name: BLU Products, Inc.
FCC ID:YHLBLUG50PS External Photos 1.EUT front view 2.EUT rear view 3.EUT left side view 4.EUT right side view 5.EUT top view 6.EUT bottom view 7.Accessories
BLU Products, Inc. Label Label Location
FCC ID:YHLBLUG50PS Internal Photos 1.EUT uncover view 2.Antenna view GSM/WCDMA/LTE Antenna BT/Wi-Fi Antenna LTE Diversity Antenna
MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Te l : 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.:SZ19120148S01 Annex B Test Setup Photos Head Right Cheek Right Tilt MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Te l : 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.:SZ19120148S01 Left Cheek Left Tilt MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Te l : 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.:SZ19120148S01 Body Front Side (Test distance: 10mm, Thickness of EU T: 9mm Back Side (Test distance: 10mm, Thickness of EU T: 9mm) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Te l : 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.:SZ19120148S01 Left Side (Test distance: 10mm, Thickness of EUT: 9mm) Right Side (Test distance: 10mm, Thickness of EUT: 9mm) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Te l : 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.:SZ19120148S01 To p Side (Test distance: 10mm, Thickness of EUT: 9mm) Bottom Side (Test distance: 10mm, Thickness of EUT: 9mm)
MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Te l : 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.:SZ19120148S01 Annex C Plots of System Performance Check Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd. Date: 2020.04.05 System Check_750MHz_Head Communication System: UID 0, CW (0); Frequency: 750 MHz;Duty Cycle: 1:1 Medium: HSL_750 Medium parameters used: f = 750 MHz; σ = 0.891 S/m; ε r = 42.234; ρ = 1000 kg/m 3 Ambient Temperature:23.2 °C; Liquid Temperature:22.1 °C DASY5 Configuration: - Probe: ES3DV3 - SN3154; ConvF(6.34, 6.34, 6.34); Calibrated: 2019.07.16; - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2019.04.11 - Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1471 - Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331) CW750/Area Scan (81x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 3.22 W/kg CW750/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 52.18 V/m; Power Drift = -0.04 dB Peak SAR (extrapolated) = 3.26 W/kg SAR(1 g) = 2.06 W/kg; SAR(10 g) = 1.35 W/kg Maximum value of SAR (measured) = 2.22 W/kg 0 dB = 2.22 W/kg Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd. Date: 2020.04.06 System Check_835MHz_Head Communication System: UID 0, CW (0); Frequency: 835 MHz;Duty Cycle: 1:1 Medium: HSL_835 Medium parameters used: f = 835 MHz; σ = 0.915 S/m; ε r = 41.261; ρ = 1000 kg/m 3 Ambient Temperature:23.2 °C; Liquid Temperature:22.2 °C DASY5 Configuration: - Probe: EX3DV4 - SN3823; ConvF(9.3, 9.3, 9.3); Calibrated: 2020.01.03; - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2019.04.11 - Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1471 - Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331) CW835/Area Scan (81x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 2.66 W/kg CW835/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,dz=5mm Reference Value = 54.45 V/m; Power Drift = 0.09 dB Peak SAR (extrapolated) = 3.59 W/kg SAR(1 g) = 2.36 W/kg; SAR(10 g) = 1.53 W/kg Maximum value of SAR (measured) = 2.88 W/kg 0 dB = 2.88 W/kg Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd. Date: 2020.04.07 System Check_1750MHz_Head Communication System: UID 0, CW (0); Frequency: 1750 MHz;Duty Cycle: 1:1 Medium: HSL_1750 Medium parameters used: f = 1750 MHz; σ = 1.367 S/m; ε r = 39.512; ρ = 1000 kg/m 3 Ambient Temperature:23.1 °C; Liquid Temperature:22.4 °C DASY5 Configuration: - Probe: EX3DV4 - SN3823; ConvF(7.99, 7.99, 7.99); Calibrated: 2020.01.03; - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2019.04.11 - Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1471 - Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331) CW1750/Area Scan (81x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 11.02 W/kg CW1750/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 86.11 V/m; Power Drift = 0.07 dB Peak SAR (extrapolated) = 17.21 W/kg SAR(1 g) = 9.31 W/kg; SAR(10 g) = 5.09 W/kg Maximum value of SAR (measured) = 10.24 W/kg 0 dB = 10.24 W/kg Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd. Date: 2020.04.08 System Check_1900MHz_Head Communication System: UID 0, CW (0); Frequency: 1900 MHz;Duty Cycle: 1:1 Medium: HSL_1900 Medium parameters used: f = 1900 MHz; σ = 1.388 S/m; ε r = 40.461; ρ = 1000 kg/m 3 Ambient Temperature:23.4 °C; Liquid Temperature:22.3 °C DASY5 Configuration: - Probe: EX3DV4 - SN3823; ConvF(7.74, 7.74, 7.74); Calibrated: 2020.01.03; - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2019.04.11 - Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1471 - Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331) CW1900/Area Scan (81x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 10.12 W/kg CW1900/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 89.24 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 17.6 W/kg SAR(1 g) = 9.88 W/kg; SAR(10 g) = 5.16 W/kg Maximum value of SAR (measured) = 10.12 W/kg 0 dB = 10.12 W/kg Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd. Date: 2020.04.09 System Check_2450MHz_Head Communication System: UID 0, CW (0); Frequency: 2450 MHz;Duty Cycle: 1:1 Medium: HSL_2450 Medium parameters used: f = 2450 MHz; σ = 1.799 S/m; ε r = 38.872; ρ = 1000 kg/m 3 Ambient Temperature:23.2 °C; Liquid Temperature:22.3 °C DASY5 Configuration: - Probe: EX3DV4 - SN3823; ConvF(7.3, 7.3, 7.3); Calibrated: 2020.01.03; - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2019.04.11 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331) CW2450/Area Scan (101x101x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 16.23 W/kg CW2450/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 92.25 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 31.34 W/kg SAR(1 g) = 13.14 W/kg; SAR(10 g) = 6.11 W/kg Maximum value of SAR (measured) = 16.23 W/kg 0 dB = 16.23 W/kg Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd. Date: 2020.04.16 System Check_2600MHz_Head Communication System: UID 0, CW (0); Frequency: 2600 MHz;Duty Cycle: 1:1 Medium: HSL_2600 Medium parameters used: f = 2600 MHz; σ = 1.962 S/m; ε r = 38.996; ρ = 1000 kg/m 3 Ambient Temperature:23.3 °C; L…
Text truncated - open the document above for the full version.
MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Te l : 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.:SZ19120148S01 Annex D Plots of Maximum SAR Test Results Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd. Date: 2020.04.06 GSM850_GPRS(2 TX slots)_Right Cheek_Ch189 Communication System: UID 0, GSM850(class 10) (0); Frequency: 836.4 MHz;Duty Cycle: 1:4.15 Medium: HSL_835 Medium parameters used: f = 836.4 MHz; σ = 0.904 S/m; ε r = 41.033; ρ = 1000 kg/m 3 Ambient Temperature:23.2 °C; Liquid Temperature:22.2 °C DASY5 Configuration: - Probe: EX3DV4 - SN3823; ConvF(9.3, 9.3, 9.3); Calibrated: 2020.01.03; - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2019.04.11 - Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1471 - Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331) Ch189/Area Scan (71x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.276 W/kg Ch189/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 5.271 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 0.318 W/kg SAR(1 g) = 0.261 W/kg; SAR(10 g) = 0.202 W/kg Maximum value of SAR (measured) = 0.275 W/kg 0 dB = 0.275 W/kg Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd. Date: 2020.04.08 GSM1900_GPRS(2 TX slots)_Left Cheek_Ch661 Communication System: UID 0, PCS1900(Class 10) (0); Frequency: 1880 MHz;Duty Cycle: 1:4.15 Medium: HSL_1900 Medium parameters used: f = 1880 MHz; σ = 1.321 S/m; ε r = 41.384; ρ = 1000 kg/m 3 Ambient Temperature:23.4 °C; Liquid Temperature:22.3 °C DASY5 Configuration: - Probe: EX3DV4 - SN3823; ConvF(7.74, 7.74, 7.74); Calibrated: 2020.01.03; - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2019.04.11 - Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1471 - Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331) Ch661/Area Scan (71x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.107 W/kg Ch661/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 3.683 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 0.150 W/kg SAR(1 g) = 0.097 W/kg; SAR(10 g) = 0.060 W/kg Maximum value of SAR (measured) = 0.101 W/kg 0 dB = 0.101 W/kg Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd. Date: 2020.04.08 WCDMA Band II_RMC 12.2Kbps_Left Cheek_Ch9400 Communication System: UID 0, UMTS-FDD (0); Frequency: 1880 MHz;Duty Cycle: 1:1 Medium: HSL_1900 Medium parameters used: f = 1880 MHz; σ = 1.321 S/m; ε r = 41.384; ρ = 1000 kg/m 3 Ambient Temperature:23.4 °C; Liquid Temperature:22.3 °C DASY5 Configuration: - Probe: EX3DV4 - SN3823; ConvF(7.74, 7.74, 7.74); Calibrated: 2020.01.03; - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2019.04.11 - Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1471 - Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331) Ch9400/Area Scan (71x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.139 W/kg Ch9400/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 4.198 V/m; Power Drift = -0.07 dB Peak SAR (extrapolated) = 0.192 W/kg SAR(1 g) = 0.125 W/kg; SAR(10 g) = 0.080 W/kg Maximum value of SAR (measured) = 0.130 W/kg 0 dB = 0.130 W/kg Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd. Date: 2020.04.07 WCDMA Band IV_RMC 12.2Kbps_Left Cheek_Ch1413 Communication System: UID 0, UMTS-FDD (0); Frequency: 1732.6 MHz;Duty Cycle: 1:1 Medium: HSL_1750 Medium parameters used: f = 1733 MHz; σ = 1.382 S/m; ε r = 39.453; ρ = 1000 kg/m 3 Ambient Temperature:23.1 °C; Liquid Temperature:22.4 °C DASY5 Configuration: - Probe: EX3DV4 - SN3823; ConvF(7.99, 7.99, 7.99); Calibrated: 2020.01.03; - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2019.04.11 - Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1471 - Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331) Ch1413/Area Scan (71x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.186 W/kg Ch1413/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 4.206 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 0.252 W/kg SAR(1 g) = 0.174 W/kg; SAR(10 g) = 0.116 W/kg Maximum value of SAR (measured) = 0.180 W/kg 0 dB = 0.180 W/kg Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd. Date: 2020.04.06 WCDMA Band V_RMC 12.2Kbps_Right Cheek_Ch4183 Communication System: UID 0, UMTS-FDD (0); Frequency: 836.6 MHz;Duty Cycle: 1:1 Medium: HSL_900 Medium parameters used: f = 837 MHz; σ = 0.923 S/m; ε r = 43.415; ρ = 1000 kg/m 3 Ambient Temperature:23.2 °C; Liquid Temperature:22.2 °C DASY5 Configuration: - Probe: EX3DV4 - SN3823; ConvF(9.3, 9.3, 9.3); Calibrated: 2020.01.03; - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2019.04.11 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331) Ch4183/Area Scan (71x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.184 W/kg Ch4183/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 3.870 V/m; Power Drift = 0.18 dB Peak SAR (extrapolated) = 0.220 W/kg SAR(1 g) = 0.176 W/kg; SAR(10 g) = 0.136 W/kg Maximum value of SAR (measured) = 0.184 W/kg 0 dB = 0.184 W/kg Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd. Date: 2020.04.08 LTE Band 2_20MHz_QPSK_1RB_0Offset_Left Cheek_Ch18900 Commun…
Text truncated - open the document above for the full version.
MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Te l : 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.:SZ19120148S01 Annex E DASY Calibration Certificate
Add: No.5 1 Xueyuan Road, HaTel: +86-10-62304633-2079 dichna N CALIBRATION1In1` N411114 11191V CNAS L0570d' Fax '+86110-b23046002 04 China E-mail: cttlachinattl com http://www.chinattl.en C lient KEHU Certificate No: Z1860194 CAL-1Li1N CERTIFICATE Object D750V3-SN: 1173 Calibration Procedure(s) FF-Z11-003-01 Calibration Procedures for dipole validation kits Calibration date: June 21, 2018 This calibration Certificate documents the traceab ility to national standards, which real ize the physical un its of measurements(S I). The measurements and the uncertainties with confidence probabi-ity are g iven on the fo llowing pages and are part of the certificate. A ll cal ibrations have been conducted in the c losed laboratory facility: environment temperature(223)C and hum idity<70%. Cal ibration Equipment used (M&TE critica-for calibration) Primary Standards ID # Cal Date(Calibrated by, Certificate No.) Schedu ed Calibration Power Meter NRVD Power sensor NRV-Z5 Reference Probe EX3DV4 DAE4 Secondary Standards 102083 01-Nov-17 (CTTL, No.J17X08756) Oct-18 100542 01-Nov-17 (CTTL, No.J17X08756) Oct-18 SN 7464 12-Sep1 7(S PEAG, No. EX3-7464-Sep17) Sep-18 SN 1525 02ct-17(SPEAG,No.DAE4-1525ctl7) Oct-18 ID # Ca Date(Ca librated by, Certificate No.) Schedu ed Ca libration S igna l Generator E4438C NetworkAnalyzer E5071 C MY49071430 23-Jan-18 (CTTL, No.JI8X00560) Jan-19 MY46110673 24-Jan-18 (CTTL, No.J18X00561) Jan-19 Name Function . Signature Calibrated by Reviewed by Approved by Issued: June 26, 2018 Th is calibration certificate sha l l not be reproduced except in full without written approval of the laboratory. Certificate No: Z 18-60194 Page 1 of8 In Collaboration with CAUBRA71ON LABORATORY Add: N 51 Xueyuan Road, Haidian District, Beijing, 100191, China Tel86-10-62304633-2079 Fax86-10-62304633-2504 E-mail: [email protected] http://www.chinatti.cn Gssary: TSL tissue s-mu lating quid ConvF sensitivity in TSL I NORMx,y,z N/A not app licable or not measured Calibration is Performed According to the Following Standards: a) IEEE Std 1528-2013, "IEEE Recommended Practice for Determining the Peak SpatiaAveraged Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techn ques", June 2013 b) IEC 62209-1, "Measurement procedure for assessment of specific absorption rate of human exposure to rad io frequency fields from hand-held and body-mounted wireless communication devices- Part 1: Device used next to the ear (Frequency range of 300MHz to 6GHz)", July 2016 c) IEC 62209-2, "Procedure to measure the Specific Absorption Rate (SAR) For wireless communication devices used in close proxim ity to the human body (frequency range of 30MHz to 6GHz)", March 2010 d) KDB865664, SAR Measurement Requirements for 100 MHz to 6 GHz Additional Documentation: e) DASY4/5 System Handbook Methods Applied and Interpretation of Parameters: . Measurement Conditions: Further deta i ls are avai lable from the Validation Report at the end of the certificate. Al l figures stated in the certificate are val id at the frequency ind cated. . Antenna Parameters with TSL: The dipole is mounted with the spacer to position its feed point exactly below the center marking of the flat phantom section, with the arms oriented para l lel to the body axis. . Feed Point Impedance and Return Loss: These parameters are measured with the d ipole positioned under the liquid fi l led phantom The impedance stated s transformed from the measurement at the SMA connector to the feed point. The Return Loss ensures low reflected power. No uncertainty requ ired . Electrical Delay: One-way delay between the SMA connector and the antenna feed point. No uncertainty required. SAmeasured: SAR measured at the stated antenna input power. SAnormalized: SAR as measured, normal ized to an input power of 1 W at the antenna connector. SAR for nominal TSL parameters: The measured TSL parameters are used to calculate the nom inal SAR resu lt. The reported uncertainty of measurement is stated as the standard uncerta inty of Measurement mu ltip lied by the coverage factor k=2, wh ich for a normal distribution Corresponds to a coverage probability of approximately 95% Certificate No: Z18-60194 Page 2 of 8 -n Collaboration win ;m1l Add: No.51 Xueyuan Road, Haidian District, Beijing, 100191, China Tel86-10-62304633-2079 Fax86-1062304633-2504 E-mail: [email protected] http://www.chinattl.cn Measurement Conditions 99Df1P99D9 DASY Version DASY52 52.10.1.1476 4 Extrapolation Advanced Extrapolation Phantom Triple F lat Phantom 5.1C 4 Distance Dipole Center - TSL 15 mm with Spacer 4 Zoom Scan Resolution dx, dy, dz = 5 mm Frequency 750 MHz 1 MHz I I 1 Head TSL parameters SAR result with Head TSL SAR averaged over 1 cm3 (1 g) of Head TSL Cond ition SAR measured 250 mW input power 2.02mW/g SAR for nom ina l Head TSL parameters norma l ized to 1W 8.26mW/g18.8 % (k=2) SAR averaged over 10 cm3 (10 g) of Head TSL Condition SAR measured 250 mW input power 1.34mW/g SAR for nom inal Head TSL parameters normalized to 1W 5.45 mW /g18.7 % (k=2 Body TSL parameters SAR result with Body TSL SAR averaged over 1 Cm3 (1 g) of Body TSL Condition SARmeasured 25mW Inputpwer 2 13mWg SAR for nomina Body TSL parameters normalized to 1W 1 8.65 mW /g18.8 % (k=2) I SAR averaged over 10 cm3 (10 g) of Body TSL SAR measured 250 mW input power 1.41 mW / g SAR for nom ina l Body TSL parameters Certificate No: Z18-60194 Page 3 of 8 In Collaboration with cAu IA Add: No.5 1 Xueyuan Road, Haidian District, Beijing, 100191, China Tel86 10-62304633-2079 Fax86-10-62304633-2504 E-mail: [email protected] http://www.chinattl.cn Appendix (Additional assessments outside the scope of CNAS L0570) Antenna Parameters with Head TSL Impedance, transformed to feed point55.20-3.01j0 Return Loss -24.9dB Antenna Parameters with Body TSL Impedance, transformed to feed point52.30-4.51j0 Return Loss -26.1 dB General Antenna Parameters and Design Electrical Delay (one d irection) 900 ns After long ter…
Text truncated - open the document above for the full version.
3 Add: No.5 I Xueyuan Road, HaTel: +86-10-62304633-2079 dan District, Beijing, 100191, China vnuorvt i ivnFax: +86-10-62304633-2504 11111h, CNAS L0570 E-mail: [email protected] http://www.chinattl.cn Cl ient KEHU Certificate No: Z18-60195 CALIBRATN CERTIFICATE Object D835V2 SN: 4d227 Ca l ibration Procedure(s) Calibration Procedures for d ipole validation kits Calibration date: June 22, 2018 This ca-ibration Certificate documents the traceabi lity to national standards, which realize the physical units of measurements(S I). The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate. All calibrations have been conducted in the closed laboratory facility: environment temperature(223)C and humidity<70%. Cal ibration Equipment used (M&TE critical for ca ibration) Primary Standards D # Ca l Date(Calibrated by, Certificate No.) Scheduled Calibration Power Meter NRVD Power sensor NRV-Z5 Reference Prob…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 10.00 mW |
Smart Phone
Equipment Class
CXX - Communications Rcvr for use w/ licensed Tx and CBsSmart Phone
Equipment Class
DTS - Digital Transmission SystemTablet
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Smart phone
Equipment Class
CXX - Communications Rcvr for use w/ licensed Tx and CBsSmart Phone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter