FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zhongshan Donlim Weili Electrical Appliances Co., Ltd./
  3. YI4DW20UX43

YI4DW20UX43Microwave Oven

Zhongshan Donlim Weili Electrical Appliances Co., Ltd.
Microwave Oven - FCC ID YI4DW20UX43 - Zhongshan Donlim Weili Electrical Appliances Co., Ltd.
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Jun 04, 2020
Application Purpose
Original Equipment
Date of Application
Jun 04, 2020
Equipment Note
Microwave Oven
Frequency Range
2450.00000000 - 2450.00000000
Company
Zhongshan Donlim Weili Electrical Appliances Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

MICROWAVE OVEN INSTRUCTION MANUAL 20UX43-L IMPORTANT SAFETY INSTRUCTIONS READ CAREFULLY AND KEEP FOR FUTURE REFERENCE Household use only SAVE THESE INSTRUCTIONS 1 .IMPORTANT SAFEGUARDS............。。.................. ......... .. When using electrical appliances basic safety precautions should be followed, including the following: WARNING – To reduce the risk of burns, electric shock, fire, injury to persons, or exposure to excessive microwave energy: 1. Read all instructions before using the appliance. 2. Read and follow the specific "PRECAUTIONS TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY" found on page 7. 3. This appliance must be grounded. Connect only to properly grounded outlet. See "GROUNDING INSTRUCTIONS" found on page 8. 4. Install or locate this appliance only in accordance with the provided installation instructions. 5. Some products such as whole eggs and sealed containers – for example, closed glass jars – are able to explode and should not be heated in this oven. 6. Use this appliance only for its intended use as described in the manual. Do not use corrosive chemicals or vapors in this appliance. This type of oven is specifically designed to heat, cook, or dry food. It is not designed for industrial or laboratory use. 7. As with any appliance, close supervision is necessary when used by children. 8. Do not operate this appliance if it has a damaged cord or plug, if it is not working properly, or if it has been damaged or dropped. 9. This appliance should be serviced only by qualified service personnel. Contact nearest authorized service facility for examination, repair, or adjustment. 10. Do not cover or block any openings on the appliance. 11. Do not store this appliance outdoors. Do not use this product near water – for example, near a kitchen sink, in a wet basement, near a swimming pool, or similar locations. 2 12. Do not immerse cord or plug in water. 13. Keep cord away from heated surfaces. 14. Do not let cord hang over edge of table or counter. 15. When cleaning surfaces of door and oven that comes together on closing the door, use only mild, nonabrasive soaps, or detergents applied with a sponge or soft cloth. 16. To reduce the risk of fire in the oven cavity: a. Do not overcook food. Carefully attend appliance when paper, plastic, or other combustible materials are placed inside the oven to facilitate cooking. b. Remove wire twist-ties from paper or plastic bags before placing bag in oven. c. If materials inside the oven ignite, keep oven door closed, turn oven off, and disconnect the power cord, or shut off power at the fuse or circuit breaker panel. d. Do not use the cavity for storage purposes. Do not leave paper products, cooking utensils, or food in the cavity when not in use. 17. Liquids, such as water, coffee, or tea are able to be overheated beyond the boiling point without appearing to be boiling. Visible bubbling or boiling when the container is removed from the microwave oven is not always present. THIS COULD RESULT IN VERY HOT LIQUIDS SUDDENLY BOILING OVER WHEN THE CONTAINER IS DISTURBED OR A UTENSIL IS INSERTED INTO THE LIQUID. 18. Notice for extension cord: a. A short power-supply cord is provided to reduce the risks resulting from becoming entangled in or tripping over a longer cord. b. Longer cord sets or extension cords are available and may be used if care is exercised in their use. c. If a long cord or extension cord is used: 1) The marked electrical rating of the cord set or extension cord should be at least as great as the electrical rating of the appliance; 3 2) The extension cord must be a grounding-type 3-wire cord; and 3) The longer cord should be arranged so that it will not drape over the counter top or tabletop where it can be pulled on by children or tripped over unintentionally. This device complies with Part 18 of the FCC Rule. The following basic precautions should always be followed when using electrical appliance: 1. Read all instructions before using. 2. Make sure the voltage in your living area corresponding to the one shown on the rating label of the appliance. And the wall socket is properly grounded. 3. TO reduce the risk of fire in the oven cavity: a. DO not overcook the food. b. Remove wire twist -ties from paper or plastic bags before placing bags in the oven. c. Do not heat oil or fat for deep drying as the temperature of oil cannot be controlled. d. After use wipe the waveguide cover with a damp cloth, followed by dry cloth to remove any food splashes and grease. Built -up grease may overheat and begin to cause smoke or catch fire. e. If materials inside the oven should smoke or ignite, keep oven door closed, turn oven off and disconnect the power supply. f. Close supervision is necessary when using disposable containers made from plastic, paper or other combustible material. 4. TO reduce the risk of explosion and sudden boiling: a. Do not place sealed containers in the oven. Baby bottles fitted with a screw cap or teat are considered to be sealed containers. b. When boiling liquid in the oven, use the wide -mouthed container and stand about 20 seconds at the end of 4 cooking to avoid delayed eruptive boiling of liquids. c. Potatoes, sausage and chestnut should be peeled or pierced before cooking. Eggs in their shell, whole hard -boiled eggs should not be heated in microwave ovens since they may explode, even after microwave heating has ended. d. The cooked liquid should not be removed out immediately. Several moments should be waited before removing. In order to avoid possible hazards caused by delayed eruptive boiling of 1iquids. e. The contents of feeding bottles and baby food jars are to be stirred or shaken and the temperature is to be checked before consumption, in order to avoid burns. 5. Never operate the oven further if the door or door seals is damaged or the oven is malfunctioned or supply cord is damaged. Return the appliance to the nearest authorised service center for repair and maintenance. Nev…

Text truncated - open the document above for the full version.

Cover Letter(s)

Zhongshan Donlim Weili Electrical Appliances Co.,Ltd. Add:Fusha Industrial Park, Fusha Town, Zhongshan, China. Tel:0760-22507145 Fax: 0760-22507100-1080 Email:[email protected] FCC Authorization 04/09/2020 FE DERAL COM MU NICATIO NS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, Zhongshan Donlim Weili Electrical Appliances Co.,Ltd ., the undersigned, hereby authorize Bay Area Compliance Laboratories Corporation to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratory Corporation on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: Print Name: Jianli Yang Titel: Engineer QA-FR-170-B

Cover Letter(s)

FCC Con f iden tial Authorization FEDERAL COMMUNICAT IONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, ( ). hereby requ ests long-term confidential treatment of information accompanying this application as outlined below:  Block Diagram  Schematics  Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Z h o n g s h a n Donlim Weili Electrical Appliances Co.,Ltd. Add:Fusha Industrial Park, Fusha Town, Zhongshan, China. Tel:0760-22507145 Fax: 0760-22507100-1080 Email:[email protected] 04 /09/2020 FCC ID: YI4DW20UX43 Sincere l y Y o ur s, Sign ature: Print Name: Jianli Yang Titel: Engineer Donlim Weili Electrical Appliances Co.,Ltd. Zhongshan

External Photos

EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS

ID Label/Location Info

EXHIBIT A - FCC ID LABEL AND LOCATION FCC ID Label FCC ID Label Location Information UTStarcom Telecom Co.,Ltd. FCC ID: O6Y-F1000G Report # ID Label and Label Location.doc Page 2 of 65 FCC PART 15.247 Report Specifications: Text is Black or white in color and is left justified. Labels are printed in indelible ink on permanent adhesive backing or silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT.

Internal Photos

EXHIBIT C - EUT INTERNAL PHOTOGRAPHS

Test Report

Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal Government. This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “★”. BACL is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with an asterisk ’*’. Customer model name, addresses, names, trademarks etc. are not considered data. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. FCC PART 18 TEST REPORT For Zhongshan Donlim Weili Electrical Appliances Co., Ltd. Fusha Industrial Park, Fusha Town, Zhongshan, China R e p o r t T y p e : O r i gi n a l R e p o r t P r o d u c t T y p e: M i c r o w a ve O ve n Report Number: RSZ200409551-00 Report Date: 2020-04-23 Reviewed By: Joson Xiao EMC Engineer Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone, Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn FCC ID: YI4DW20UX43 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200409551-00 FCC Part 18 Page 2 of 23 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 3 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 3 OBJECTIVE ................................................................................................................................................................... 3 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................. 3 TEST METHODOLOGY .................................................................................................................................................. 3 MEASUREMENT UNCERTAINTY .................................................................................................................................... 3 TEST FACILITY ............................................................................................................................................................. 4 OPERATING CONDITION/TEST CONFIGURATION .......................................................................................... 5 JUSTIFICATION ............................................................................................................................................................. 5 EUT EXERCISE SOFTWARE .......................................................................................................................................... 5 SPECIAL ACCESSORIES ................................................................................................................................................. 5 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 5 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 5 EXTERNAL CABLE LIST AND DETAILS ......................................................................................................................... 5 CONFIGURATION OF TEST SETUP ................................................................................................................................. 5 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 6 SUMMARY OF TEST RESULT ................................................................................................................................. 7 TEST EQUIPMENT LIST ........................................................................................................................................... 8 CONDUCTED EMISSIONS ...................................................................................................................................... 10 APPLICABLE STANDARD ............................................................................................................................................ 10 EUT SETUP ................................................................................................................................................................ 10 EMI TEST RECEIVER SETUP ....................................................................................................................................... 10 TEST PROCEDURE ...................................................................................................................................................... 11 TEST RESULTS SUMMARY .......................................................................................................................................... 11 TEST DATA ................................................................................................................................................................ 11 RADIATION HAZARD MEASUREMENT ............................................................................................................. 14 APPLICABLE STANDARD ............................................................................................................................................ 14 ENVIRONMENTAL CONDITIONS .................................................................................................................................. 14 RADIATION HAZARD MEASUREMENT .......................…

Text truncated - open the document above for the full version.

Test Setup Photos

EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emissions - Front View Conducted Emissions - Side View Radiated Emissions - Front View (30 MHz – 1 GHz) Radiated Emissions - Rear View (30 MHz – 1 GHz) Radiated Emissions - Front View (Above 1 GHz) Radiated Emissions - Rear View (Above 1 GHz)

Contact Information

Applicant

Jianli Yang(Engineer)
[email protected]0760-22507145Fax: 0760-22507100-1080

Test Firm

Bay Area Compliance Laboratories Corp. (Shenzhen)Well Wang
[email protected]+86 (0) 755 33320018

Technical Specifications

#Rule PartsFrequency RangePower Output
1182.45 GHz - 2.45 GHz-
Confidentiality
Long Term
Grant Notes
Magnetron: SUNBOW M24B111H

Other Applications from Zhongshan Donlim Weili Electrical Appliances Co., Ltd.

Microwave Oven - FCC ID YI4DWC42PXP34 - Guangdong Welly Electrical Appliances Co., Ltd
YI4DWC42PXP34

Microwave Oven

Aug 21, 2026

Equipment Class

8CC - Part 18 Consumer Device
YI4DWT25PXP62

Microwave Oven

Mar 20, 2026

Equipment Class

8CC - Part 18 Consumer Device
Microwave Oven - FCC ID YI4DWT30PXP24 - Guangdong Welly Electrical Appliances Co., Ltd
YI4DWT30PXP24

Microwave Oven

Mar 20, 2026

Equipment Class

8CC - Part 18 Consumer Device
Microwave Oven - FCC ID YI4DWT30PXP68 - Guangdong Welly Electrical Appliances Co., Ltd
YI4DWT30PXP68

Microwave Oven

Dec 18, 2025

Equipment Class

8CC - Part 18 Consumer Device
Microwave Oven - FCC ID YI4DWF20UXP33 - Guangdong Welly Electrical Appliances Co., Ltd
YI4DWF20UXP33

Microwave Oven

Dec 18, 2025

Equipment Class

8CC - Part 18 Consumer Device