  1. Home/
  2. Zhongshan Donlim Weili Electrical Appliances Co., Ltd./
  3. YI4DW20UX79L

YI4DW20UX79LMicrowave Oven

Zhongshan Donlim Weili Electrical Appliances Co., Ltd.
Microwave Oven - FCC ID YI4DW20UX79L - Zhongshan Donlim Weili Electrical Appliances Co., Ltd.
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Jul 17, 2013
Application Purpose
Original Equipment
Date of Application
Jul 17, 2013
Equipment Note
Microwave Oven
Frequency Range
2450.00000000 - 2450.00000000
Company
Zhongshan Donlim Weili Electrical Appliances Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

MICROWAVE OVEN INSTRUCTION MANUAL 20UX79-L Please read this booklet carefully before fixing and using, and keep it for future reference 1 Installation 1. Take out all the packing. if there is a safe film over the oven, tear it off before Use. Check carefully for damage. if any, immediately notify dealer or send to the manufacturer’s service center. 2. Microwave ovens must be placed under dry and non-corrosiveness environments, kept away from heat and humidity, such as gas burner or water tank. 3. to ensure sufficient ventilation, the distance of the back of microwave to the wall should be at least 10 cm, the side to the wall should be at least 5 cm, the free distance above the top surface at least 20 cm. the distance of the microwave to the ground should be at least 85 cm. 4. the position of the oven shall be such that it is far from the TV, Radio or antenna as picture disturbance. Or noise may occur. 5. the appliance must be positioned so that the plug is accessible, and must ensure a good grounding in case leakage, ground loop can be formed to avoid electric shock. 6. The microwave oven must be operated with the door closed. 7. The microwave oven shall not be placed in a cabinet. 8. The back of the oven must be placed against a wall. 9. As there is manufacturing residue or oil remained on the oven cavity or heat element, it usually would smell the odor, even a slight smoke, It is normal case and would not occur after several times use, keep the door or window open to ensure good ventilation. So it is strongly recommended to place a cup of water in the turntable, setting at high power and operate for several times. IMPORTANT SAFEGUARDS The following basic precautions should always be followed when using electrical appliance : 1 . Read all instructions before using . 2 . Make sure the voltage in your living area corresponding to the one shown on the rating label of the appliance . And the wall socket is properly grounded . 3 . TO reduce the risk of fire in the oven cavity : a . DO not overcook the food . b . Remove wire twist - ties from paper or plastic bags before placing bags in the oven . c . Do not heat oil or fat for deep drying as the temperature of oil cannot be controlled . d . After use wipe the waveguide cover with a damp cloth , followed by dry cloth to remove any food splashes and grease . Built -up grease may overheat and begin to cause smoke or catch fire . e . If materials inside the oven should smoke or ignite , keep oven door closed, turn oven off and disconnect the power supply . f .Close supervision is necessary when using disposable containers made from plastic, paper or other combustible material . 4 . TO reduce the risk of explosion and sudden boiling : a . Do not place sealed containers in the oven . Baby bottles fitted with a screw cap or teat are considered to be sealed containers . b . When boiling liquid in the oven , use the wide -mouthed container and stand about 20 seconds at the end of cooking to avoid delayed eruptive boiling of 2 liquids . c . Potatoes ,sausage and chestnut should be peeled or pierced before cooking . Eggs in their shell , whole hard -boiled eggs should not be heated in microwave ovens since they may explode , even after microwave heating has ended . d . The cooked liquid should not be removed out immediately . Several moments should be waited before removing. In order to avoid possible hazards caused by delayed eruptive boiling of 1iquids . e . The contents of feeding bottles and baby food jars are to be stirred or shaken and the temperature is to be checked before consumption , in order to avoid burns . 5 . Never operate the oven further if the door or door seals is damaged or the oven is malfunctioned or supply cord is damaged . Return the appliance to the nearest authorised service center for repair and maintenance . Never try to adjust or repair the oven yourself . 6 . If the supply cord is damaged ,it must be replaced by the manufacturer or its service agent or a qualified technician in order to avoid a shock hazard . 7 . After cooking , the container is very hot . Using gloves to take out the food and avoid steam burns by directing steam away from the face and hands . 8 . Slowly lift the furthest edge of dishes cover and microwave plastic wrap and carefully open popcorn and oven cooking bags away from the face . 9 . TO prevent the turntable from breaking : a . Let the turntable cool down before cleaning . b . Do not place hot foods or utensils on the cold turntable . c . Do not place frozen foods or utensils on the hot turntable . 10. Make sure the utensils do not touch the interior walls during cooking . 11. Failure to maintain the oven in a clean condition could lead to deterioration of the surface that could adversely affect the life of the appliance and possibly result in a hazardous situation . 12 .Only use utensils that are suitable for use in microwave ovens . 13 . Do not store food or any other things inside the oven . 14 . Do not operate the oven without any liquid or food inside the oven . This would do damage the oven . 15 . This appliance is not intended for using by young children or infirm persons without supervision . 16 . When the appliance is operated in the combination mode , children should only use the oven under adult supervision due to the temperatures generated . 17 . Any accessories not recommended by the manufacturer may cause injuries to persons . 18 . Do not use outdoors . 19 . Save these instructions . 20 . WARNING : If the door or door seals are damaged , the oven must not be operated until it has been repaired by a competent person ; 21 . WARNING : It is hazardous for anyone other than a competent person to carry out any service or repair operation that involves the removal of a cover which gives protection against exposure to microwave energy ; 22.WARNING:Liquids and other foods must not be heated sealed container since they are liable to explode; 23. WARNING: Only allow children to use the oven with…

Text truncated - open the document above for the full version.

Cover Letter(s)

Zhongshan Donlim Weili Electrical Appliances Co.,Ltd Add:Fusha Industrial Park, Fusha Town, Zhongshan City, Guangdong Province,P.R.China. Tel:0760-22507145 Fax: 0760-22507100-1080 FCC Authorization 2013-5-16 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, Zhongshan Donlim Weili Electrical Appliances Co.,Ltd,the undersigned, hereby authorizes Bay Area Compliance Laboratories Corporation to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: Jianli Yang QC manager

Cover Letter(s)

Zhongshan Donlim Weili Electrical Appliances Co.,Ltd Add:Fusha Industrial Park, Fusha Town, Zhongshan City, Guangdong Province,P.R.China. Tel:0760-22507145 Fax: 0760-22507100-1080 FCC Confidential Authorization 2013-5-16 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Confidentiality Request regarding application for certification of FCC ID: YI4DW20UX79L Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: ƒ Block Diagram--- (Long term) ƒ Circuit Description--- (Long term) ƒ Detailed Circuit Schematics of EUT--- (Long term) The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the grant for this application. Sincerely Yours, Signature: Jianli Yang QC manager

External Photos

EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS EUT – Front View EUT – Open View EUT – Rear View EUT – Top View EUT – Bottom View EUT – Left Side View EUT – Right Side View

ID Label/Location Info

EXHIBIT A - FCC ID LABEL AND LOCATION FCC ID Label Proposed FCC ID Label Location Specifications : Text is Black or white in color and is left justified. Labels are printed in indelible ink on permanent adhesive backing or silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. Label here

Internal Photos

EXHIBIT C - EUT INTERNAL PHOTOGRAPHS EUT – Cover off View EUT – Main Board Cover off View EUT – Main Board Top View EUT – Main Board Bottom View EUT – Main Board Left View EUT – Main Board Right View EUT – Power Board Top View EUT – Power Board Bottom View EUT – Fan Front View EUT – Fan Rear View EUT – Magnetron Front View EUT – Magnetron Rear View EUT – Magnetron Side View EUT – Power Transformer Top View EUT – Power Transformer Side View EUT – H.V. Capacitor View EUT – Motor View EUT – RG303 View EUT – Light View

Test Report

Note: This test report is prepared for the customer shown above and for the equipment described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. FCC PART 18 TEST REPORT For Zhongshan Donlim Weili Electrical Appliances Co., Ltd. Fusha Industrial Park ,Fusha Town ,Zhongshan City, Guangdong Province, P.R. China FCC ID: YI4DW20UX79L Report Type: Original Product Name: Microwave Oven Test Engineer: Joson Xiao Report Number: RSZ130523550-00 Report Date: 2013-07-01 Reviewed By: Dick Zhang EMC Leader Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ130523550-00 FCC Part 18 Page 2 of 20 TABLE OF CONTENTS GENERAL INFORMATION.......................................................................................................................................3 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3 OBJECTIVE...................................................................................................................................................................3 RELATED SUBMITTAL(S)/GRANT(S).............................................................................................................................3 TEST METHODOLOGY..................................................................................................................................................3 TEST FACILITY.............................................................................................................................................................3 OPERATING CONDITION/TEST CONFIGURATION..........................................................................................4 JUSTIFICATION.............................................................................................................................................................4 EQUIPMENT MODIFICATIONS.......................................................................................................................................4 EXTERNAL CABLE LIST AND DETAILS.........................................................................................................................4 CONFIGURATION OF TEST SETUP.................................................................................................................................4 BLOCK DIAGRAM OF TEST SETUP................................................................................................................................4 CONDUCTED EMISSIONS ........................................................................................................................................5 APPLICABLE STANDARD..............................................................................................................................................5 MEASUREMENT UNCERTAINTY....................................................................................................................................5 EUT SETUP..................................................................................................................................................................5 EMI TEST RECEIVER SETUP.........................................................................................................................................6 TEST PROCEDURE........................................................................................................................................................6 TEST EQUIPMENT LIST AND DETAILS...........................................................................................................................6 TEST RESULTS SUMMARY............................................................................................................................................6 TEST DATA..................................................................................................................................................................7 RADIATION HAZARD MEASUREMENT ...............................................................................................................9 APPLICABLE STANDARD..............................................................................................................................................9 ENVIRONMENTAL CONDITIONS....................................................................................................................................9 TEST EQUIPMENT LIST AND DETAILS...........................................................................................................................9 RADIATION HAZARD MEASUREMENT..........................................................................................................................9 INPUT POWER.............................................................................................................................................................10 LOAD FOR MICROWAVE OVENS.................................................................................................................................10 RF OUTPUT POWER MEASUREMENT..........................................................................................................................10 OPERATING FREQUENCY MEASUREMENT..................................................................................................................11 RADIATED EMISSIONS...........................................................................................................................................15 APPLICABLE STANDARD................................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

EXHIBIT D - TEST SETUP PHOTOGRAPHS Conduction Emissions - Front View Conduction Emissions - Side View Radiated Emissions - Front View (9 kHz – 30 MHz) Radiated Emissions - Rear View (9 kHz – 30 MHz) Radiated Emissions - Front View (30 MHz – 1 GHz) Radiated Emissions - Rear View (30 MHz – 1 GHz) Radiated Emissions - Front View (Above 1 GHz) Radiated Emissions - Rear View (Above 1 GHz)

Contact Information

Applicant

Yanjun Gao(Engineer)
[email protected]0760-22507015Fax: 0760-22507100-1080

Test Firm

Bay Area Compliance Laboratory Corp. (Shenzhen)John Chan
[email protected]08675533320018Fax: 08675533320008

Technical Specifications

#Rule PartsFrequency RangePower Output
1182.45 GHz - 2.45 GHz-
Confidentiality
Long Term
Grant Notes
Magnetron: SUNBOW-2M219J

Other Applications from Zhongshan Donlim Weili Electrical Appliances Co., Ltd.

Microwave Oven - FCC ID YI4DWC42PXP34 - Guangdong Welly Electrical Appliances Co., Ltd
YI4DWC42PXP34

Microwave Oven

Aug 21, 2026

Equipment Class

8CC - Part 18 Consumer Device
YI4DWT25PXP62

Microwave Oven

Mar 20, 2026

Equipment Class

8CC - Part 18 Consumer Device
Microwave Oven - FCC ID YI4DWT30PXP24 - Guangdong Welly Electrical Appliances Co., Ltd
YI4DWT30PXP24

Microwave Oven

Mar 20, 2026

Equipment Class

8CC - Part 18 Consumer Device
Microwave Oven - FCC ID YI4DWT30PXP68 - Guangdong Welly Electrical Appliances Co., Ltd
YI4DWT30PXP68

Microwave Oven

Dec 18, 2025

Equipment Class

8CC - Part 18 Consumer Device
Microwave Oven - FCC ID YI4DWF20UXP33 - Guangdong Welly Electrical Appliances Co., Ltd
YI4DWF20UXP33

Microwave Oven

Dec 18, 2025

Equipment Class

8CC - Part 18 Consumer Device