FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zhongshan Donlim Weili Electrical Appliances Co., Ltd./
  3. YI4DWE25UXP09

YI4DWE25UXP09Household Microwave Oven

Zhongshan Donlim Weili Electrical Appliances Co., Ltd.
Household Microwave Oven - FCC ID YI4DWE25UXP09 - Zhongshan Donlim Weili Electrical Appliances Co., Ltd.
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Nov 07, 2023
Application Purpose
Original Equipment
Date of Application
Nov 07, 2023
Equipment Note
Household Microwave Oven
Frequency Range
2450.00000000 - 2450.00000000
Company
Zhongshan Donlim Weili Electrical Appliances Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

MICROWAVE OVEN INSTRUCTION MANUAL E25UXP09-A90 IMPORTANT SAFETY INSTRUCTIONS READ CAREFULLY AND KEEP FOR FUTURE REFERENCE Household use only SAVE THESE INSTRUCTIONS 2 .IMPORTANT SAFEGUARDS............。。.................. ......... .. When using electrical appliances basic safety precautions should be followed, including the following: WARNING – To reduce the risk of burns, electric shock, fire, injury to persons, or exposure to excessive microwave energy: 1. Read all instructions before using the appliance. 2. Read and follow the specific "PRECAUTIONS TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY" found on page 7. 3. This appliance must be grounded. Connect only to properly grounded outlet. See "GROUNDING INSTRUCTIONS" found on page 8. 4. Install or locate this appliance only in accordance with the provided installation instructions. 5. Some products such as whole eggs and sealed containers – for example, closed glass jars – are able to explode and should not be heated in this oven. 6. Use this appliance only for its intended use as described in the manual. Do not use corrosive chemicals or vapors in this appliance. This type of oven is specifically designed to heat, cook, or dry food. It is not designed for industrial or laboratory use. 7. As with any appliance, close supervision is necessary when used by children. 8. Do not operate this appliance if it has a damaged cord or plug, if it is not working properly, or if it has been damaged or dropped. 9. This appliance should be serviced only by qualified service personnel. Contact nearest authorized service facility for 3 examination, repair, or adjustment. 10. Do not cover or block any openings on the appliance. 11. Do not store this appliance outdoors. Do not use this product near water – for example, near a kitchen sink, in a wet basement, near a swimming pool, or similar locations. 12. Do not immerse cord or plug in water. 13. Keep cord away from heated surfaces. 14. Do not let cord hang over edge of table or counter. 15. When cleaning surfaces of door and oven that comes together on closing the door, use only mild, nonabrasive soaps, or detergents applied with a sponge or soft cloth. 16. To reduce the risk of fire in the oven cavity: a. Do not overcook food. Carefully attend appliance when paper, plastic, or other combustible materials are placed inside the oven to facilitate cooking. b. Remove wire twist-ties from paper or plastic bags before placing bag in oven. c. If materials inside the oven ignite, keep oven door closed, turn oven off, and disconnect the power cord, or shut off power at the fuse or circuit breaker panel. d. Do not use the cavity for storage purposes. Do not leave paper products, cooking utensils, or food in the cavity when not in use. 17. Liquids, such as water, coffee, or tea are able to be overheated beyond the boiling point without appearing to be boiling. Visible bubbling or boiling when the container is removed from the microwave oven is not always present. THIS COULD RESULT IN VERY HOT LIQUIDS SUDDENLY BOILING OVER WHEN THE CONTAINER IS DISTURBED OR A UTENSIL IS INSERTED INTO THE 4 LIQUID. 18. Notice for extension cord: a. A short power-supply cord is provided to reduce the risks resulting from becoming entangled in or tripping over a longer cord. b. Longer cord sets or extension cords are available and may be used if care is exercised in their use. c. If a long cord or extension cord is used: 1) The marked electrical rating of the cord set or extension cord should be at least as great as the electrical rating of the appliance; 2) The extension cord must be a grounding-type 3-wire cord; and 3) The longer cord should be arranged so that it will not drape over the counter top or tabletop where it can be pulled on by children or tripped over unintentionally. The following basic precautions should always be followed when using electrical appliance: 1. Read all instructions before using. 2. Make sure the voltage in your living area corresponding to the one shown on the rating label of the appliance. And the wall socket is properly grounded. 3. TO reduce the risk of fire in the oven cavity: a. DO not overcook the food. b. Remove wire twist -ties from paper or plastic bags before placing bags in the oven. c. Do not heat oil or fat for deep drying as the temperature of oil cannot be controlled. 5 d. After use wipe the waveguide cover with a damp cloth, followed by dry cloth to remove any food splashes and grease. Built -up grease may overheat and begin to cause smoke or catch fire. e. If materials inside the oven should smoke or ignite, keep oven door closed, turn oven off and disconnect the power supply. f. Close supervision is necessary when using disposable containers made from plastic, paper or other combustible material. 4. TO reduce the risk of explosion and sudden boiling: a. Do not place sealed containers in the oven. Baby bottles fitted with a screw cap or teat are considered to be sealed containers. b. When boiling liquid in the oven, use the wide -mouthed container and stand about 20 seconds at the end of cooking to avoid delayed eruptive boiling of liquids. c. Potatoes, sausage and chestnut should be peeled or pierced before cooking. Eggs in their shell, whole hard -boiled eggs should not be heated in microwave ovens since they may explode, even after microwave heating has ended. d. The cooked liquid should not be removed out immediately. Several moments should be waited before removing. In order to avoid possible hazards caused by delayed eruptive boiling of 1iquids. e. The contents of feeding bottles and baby food jars are to be stirred or shaken and the temperature is to be checked before consumption, in order to avoid burns. 5. Never operate the oven further if the door or door seals is damaged or the oven is malfunctioned or supply cord is 6 damaged. Return the appliance to the nearest authorised service center for repair and maintenance. Never try to adjust or repair the oven yourself.…

Text truncated - open the document above for the full version.

Attestation Statements

U.S. AGENT LETTER OF ATTESTATION 2023-8-23 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(7) Filing FCC ID: Zhongshan Donlim Weili Electrical Appliances Co.,Ltd. certifies that, as of the date of the filing of the application, Emerson Radio Corp. is our designated U.S. agent for service of process for the above referenced FCC ID. Zhongshan Donlim Weili Electrical Appliances Co.,Ltd. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Emerson Radio Corp. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Emerson Radio Corp. Address: 959 Route 46 East, Suite 210,2 nd Floor, Parsippany, NJ 07054 FRN: 0026321828 Tel.: +1(973)4282436 Email: [email protected] Signed by (printed name): Brian Leung Signature: Applicant: Zhongshan Donlim Weili Electrical Appliances Co.,Ltd. Address: Fusha Industrial Park, Fusha Town, Zhongshan, China FRN: 0019939883 Tel: 0760-22507145 Email: [email protected] Signed by (printed name): Jianli Yang Signature: YI4DWE25UXP09

Attestation Statements

Zhongshan Donlim Weili Electrical Appliances Co.,Ltd. Fusha Industrial Park, Fusha Town, Zhongshan, China TEL: 0760-22507145 Email: [email protected] Date: 2023-08-24 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for FCC ID: YI4DWE25UXP09 Zhongshan Donlim Weili Electrical Appliances Co.,Ltd. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Signature: Print Name: Jianli Yang Titel: Engineer Zhongshan Donlim Weili Electrical Appliances Co.,Ltd. Fusha Industrial Park, Fusha Town, Zhongshan, China TEL: 0760-22507145 Email: [email protected] Date: 2023-08-24 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for FCC ID: YI4DWE25UXP09 Zhongshan Donlim Weili Electrical Appliances Co.,Ltd. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Print Name: Jianli Yang Titel: Engineer

Cover Letter(s)

Zhongshan Donlim Weili Electrical Appliances Co.,Ltd. Address: Fusha Industrial Park, Fusha Town, Zhongshan, China Tel: 0760-22507145 Email: [email protected] Fax: 0760‐22507100‐1080 FCC Confidential Authorization 2023-8-23 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: YI4DWE25UXP09 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Zhongshan Donlim Weili Electrical Appliances Co., Ltd. hereby requests long-term confidential treatment of information accompanying this application as outlined below:  Block Diagram  Schematics  Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature: Print Name: Jianli Yang Title: Engineer

Cover Letter(s)

Zhongshan Donlim Weili Electrical Appliances Co.,Ltd. Address: Fusha Industrial Park, Fusha Town, Zhongshan, China Tel: 0760-22507145 Email: [email protected] Date: 2023-08-24 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, Zhongshan Donlim Weili Electrical Appliances Co.,Ltd. the undersigned, hereby authorize China Certification ICT Co., Ltd (Dongguan)to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Print Name: Jianli Yang Titel: Engineer

External Photos

China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-EXP Page 1 of 4 EUT EXTERNAL PHOTOGRAPHS China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-EXP Page 2 of 4 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-EXP Page 3 of 4 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-EXP Page 4 of 4

ID Label/Location Info

Label Location

Internal Photos

China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-INP Page 1 of 11 EUT INTERNAL PHOTOGRAPHS China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-INP Page 2 of 11 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-INP Page 3 of 11 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-INP Page 4 of 11 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-INP Page 5 of 11 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-INP Page 6 of 11 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-INP Page 7 of 11 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-INP Page 8 of 11 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-INP Page 9 of 11 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-INP Page 10 of 11 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-INP Page 11 of 11

RF Exposure Info

China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-00A1 Page 29 of 31 5. RF EXPOSURE EVALUATION 5.1 Maximum Permissible Exposure (MPE) 5.1.1 Applicable Standard According to subpart §1.1310, systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. 5.1.2 Limits Maximum Permissible Exposure (MPE) (§1.1310, §2.1091) (B) Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f²) 30 30–300 27.5 0.073 0.2 30 300–1500 / / f/1500 30 1500–100,000 / / 1.0 30 f = frequency in MHz; * = Plane-wave equivalent power density; According to §1.1310 and §2.1091 RF exposure is calculated. 5.1.3 Measurement Radiation leakage was measured in the as-received condition with the oven door closed using a microwave leakage meter. A 275 mL water load was placed in the center of the oven and the oven was operated at maximum output power. There was no microwave leakage exceeding a power level of 0.1mW/cm 2 observed at any point 5 cm or more from the external surface of the oven. A maximum of 1.0 mW/cm 2 is allowed in accordance with the applicable Federal Standards. Hence, microwave leakage in the as-received condition with the oven door closed was below the maximum allowed.

Test Report

TEST REPORT Applicant: Zhongshan Donlim Weili Electrical Appliances Co.,Ltd Address: Fusha Industrial Park, Fusha Town, Zhongshan City, Guangdong Province, China FCC ID: YI4DWE25UXP09 Product Name: Household Microwave Oven Model Number: E25UXP09-A90 Standard(s): FCC PART 18 FCC MP-5:1986 The above device has been tested and found compliant with the requirement of the relative standards by China Certification ICT Co., Ltd (Dongguan) Report Number: CR230742267-00A1 Date Of Issue: 2023/8/15 Reviewed By: Calvin Chen Title: RF Engineer Approved By: Sun Zhong Title: Manager Test Laboratory: China Certification ICT Co., Ltd (Dongguan) No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China Tel: +86-769-82016888 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-00A1 Page 2 of 32 Test Facility The Test site used by China Certification ICT Co., Ltd (Dongguan) to collect test data is located on the No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China. The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 442868, the FCC Designation No. : CN1314. The lab has been recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements, the CAB identifier: CN0123. Declarations China Certification ICT Co., Ltd (Dongguan) is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol “▲”. Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk “★”. China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-00A1 Page 3 of 32 CONTENTS DOCUMENT REVISION HISTORY ......................................................................................................................... 4 1. GENERAL INFORMATION ................................................................................................................................... 5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ............................................................................... 5 1.2 DESCRIPTION OF TEST CONFIGURATION ................................................................................................................ 6 1.2.2 Support Equipment List and Details .............................................................................................................. 6 1.2.3 Support Cable List and Details ...................................................................................................................... 6 1.2.4 Block Diagram of Test Setup ......................................................................................................................... 7 1.3 MEASUREMENT UNCERTAINTY .............................................................................................................................. 8 2. SUMMARY OF TEST RESULTS ........................................................................................................................... 9 3. REQUIREMENTS AND TEST PROCEDURES ................................................................................................. 10 3.1 AC LINE CONDUCTED EMISSIONS ........................................................................................................................ 10 3.1.1 EUT Setup.................................................................................................................................................... 10 3.1.2 EMI Test Receiver Setup ............................................................................................................................. 10 3.1.3 Test Procedure ............................................................................................................................................. 11 3.1.4 Corrected Amplitude & Margin Calculation ................................................................................................ 11 3.2 RADIATION SPURIOUS EMISSIONS ........................................................................................................................ 12 3.2.1 EUT Setup.................................................................................................................................................... 12 3.2.2 EMI Test Receiver Setup ............................................................................................................................. 13 3.2.3 Test Procedure ............................................................................................................................................. 13 3.2.4 Corrected Amplitude & Margin Calculation ................................................................................................ 13 3.3 RADIATION HAZARD MEASUREMENT .................................................................................................................. 14 3.3.1 Applicable Standard ..................................................................................................................................... 14 3.3.2 Test Procedure ............................................................................................................................................. 14 1) Input Power ...................................................................................................................................................... 14 2) RF Output …

Text truncated - open the document above for the full version.

Test Setup Photos

China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-00A1-TSP TEST SETUP PHOTOGRAPHS Conducted Emissions Front View Conducted Emissions Side View China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-00A1-TSP Radiated Emission Below 1GHz Front View Radiated Emission Below 1GHz Rear View China Certification ICT Co., Ltd (Dongguan) Report No.: CR230742267-00A1-TSP Radiated Emission Above 1GHz Front View Radiated Emission Above 1GHz Rear View

Contact Information

Applicant

Yanjun Gao(Engineer)
[email protected]0760-22507015Fax: 0760-22507100-1080

Test Firm

CHINA CERTIFICATION ICT CO., LTD (DONGGUAN)Tanie Ou
[email protected]0086 0769 86858888

Technical Specifications

#Rule PartsFrequency RangePower Output
1182.45 GHz - 2.45 GHz-
Confidentiality
Long Term

Other Applications from Zhongshan Donlim Weili Electrical Appliances Co., Ltd.

Microwave Oven - FCC ID YI4DWC42PXP34 - Guangdong Welly Electrical Appliances Co., Ltd
YI4DWC42PXP34

Microwave Oven

Aug 21, 2026

Equipment Class

8CC - Part 18 Consumer Device
YI4DWT25PXP62

Microwave Oven

Mar 20, 2026

Equipment Class

8CC - Part 18 Consumer Device
Microwave Oven - FCC ID YI4DWT30PXP24 - Guangdong Welly Electrical Appliances Co., Ltd
YI4DWT30PXP24

Microwave Oven

Mar 20, 2026

Equipment Class

8CC - Part 18 Consumer Device
Microwave Oven - FCC ID YI4DWT30PXP68 - Guangdong Welly Electrical Appliances Co., Ltd
YI4DWT30PXP68

Microwave Oven

Dec 18, 2025

Equipment Class

8CC - Part 18 Consumer Device
Microwave Oven - FCC ID YI4DWF20UXP33 - Guangdong Welly Electrical Appliances Co., Ltd
YI4DWF20UXP33

Microwave Oven

Dec 18, 2025

Equipment Class

8CC - Part 18 Consumer Device