EMKUT0036-02 1 Consert ® Tru Smart Energy Gateway 2.0 Data Sheet Overview The Consert ® Tru Smart Energy Gateway (SEG) creates the only real-time data profile model of residential properties and small commercial businesses. Easily installed within smart meters, the SEG provides high-speed, two-way communications between the Consert Data Center and HAN devices located inside a customer’s premises. Achieved through customer consent, this data collection creates a symbiotic relationship between a utility and its customer providing benefits and rewards for both, such as remote data acquisition, demand response, load control, meter management, and home energy management. Features and Benefits • Two-way, high-speed communications with Smart Energy Profile (SEP) 1.0 Home Area Network (HAN) devices • Collects data directly from AMI meters, Consert Tru Load Device Controllers and a variety of SEP 1.0 compliant Programmable Computing Thermostats (PCT) • Two-way, high-speed, real-time communications with Consert Data Center • WAN Communications slot supports: EVDO • Fully redundant data path to Consert Tru Load Device Controllers via wireless ZigBee ® and HomePlug ® AV powerline • Embedded Linux environment with self-contained memory and battery backup capabilities • Complete security with encrypted two-way communications that meets or exceeds today’s stringent requirements • ANSI-compliant with partnership of variety meter manufacturers (I am not aware of any ANSI testing that has been performed.) • Firmware upgradeable over the air Environment • Industrial temperature rated parts (-40 C to +65 C) Electrical • Supports supply voltages from 110 to 240 volts Communications • ZigBee ® 100mW ERP radio (2.4 GHz) • HomePlug A/V • CDMA EVDO Rev. A/HSPA modem • Secure two-way communications EMKUT0036-02 2 Regulatory Information USA-Federal Communications Commission (FCC) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. • Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. • Caution: Exposure to Radio Frequency Radiation. To comply with FCC RF exposure compliance requirements, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons. This device must not be co-located or operating in conjunction with any other antenna or transmitter. Consert Inc. 4700 Falls of Neuse Road, Suite 340 Raleigh, North Carolina 27609 www.consert.com P 919-855-1060 / F 919-713-0058 © 2009–2010 Consert Inc. All rights reserved. Consert, Communicate-Control-Conserve, and Virtual Peak Plant are either registered trademarks or service marks of Consert Inc. ZigBee ® is a registered trademark of the ZigBee Alliance. HomePlug ® is a registered trademark of the HomePlug Alliance.
Underwriters Laboratories Inc. 12 Laboratory Dr. Research Triangle Park, NC 27709 www.ul.com/emc (919) 549-1400 Report Number: 10CA28335-FCC Project Number: 10CA28335 File Number: MC16580 Date: July 30, 2010 Model: CMGYZHPECD 3.0 (Gateway for GE Series I-210 meter) Electromagnetic Compatibility Test Report for Consert Inc. Raleigh, NC Copyright 2010 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety. Underwriters Laboratories Inc. A not-for-profit organization dedicated to public safety and committed to quality service for over 100 years 12 Laboratory Dr. Research Triangle Park, NC 27709 Tel: (919) 549-1400 Project Number: 10CA28335 File Number: MC16580 Page 2 of 66 Model Number: CMGYZHPECD 3.0 (Gateway for GE I-210 series meter) Client Name: Consert Inc. FCC ID: YJ4CMGYZHPECD30 Test Report Details Tests Performed By: Underwriters Laboratories Inc. 12 Laboratory Dr. Research Triangle Park, NC 27709 Tests Performed For: Consert Inc. 4700 Falls of the Neuse Rd Raleigh, NC 27612 Applicant Contact: Thi Phan Phone: (919) 855-1069 E-mail: [email protected] Test Report Date: 07/30/2010 Product Type: Spread-Spectrum Transmitter Product standards FCC Part 15, Subpart C, Section 15.247 Model Number: CMGYZHPECD 3.0 Sample Serial Number: 2410-00000034 EUT Category: Low-Powered Transmitter Testing Start Date: 06/29/2010 Date Testing Complete: 07/06/2010 (Follow-up measurement on 07/29/2010) Overall Results: Compliant Underwriters Laboratories Inc. reports apply only to the specific samples tested under stated test conditions. All samples tested were in good operating condition throughout the entire test program. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. Underwriters Laboratories Inc. shall have no liability for any deductions, inferences or generalizations drawn by the client or others from Underwriters Laboratories Inc. issued reports. This report shall not be used to claim, constitute or imply product certification, approval, or endorsement by NVLAP, NIST, A2LA, or any agency of the US government. This report may contain test results that are not covered by the NVLAP or A2LA accreditation. The scope of accreditation is limited to the specific tests that are listed on the NVLAP and/or A2LA websites referenced at the end of this report. Underwriters Laboratories Inc. 12 Laboratory Dr. Research Triangle Park, NC 27709 USA Tel.: 919 549-1400 Rev. No 1.0 EMC Report 2007 Project Number: 10CA28335 File Number: MC16580 Page 3 of 66 Model Number: CMGYZHPECD 3.0 (Gateway for GE I-210 series meter) Client Name: Consert Inc. FCC ID: YJ4CMGYZHPECD30 Report Directory 1.0 G E N E R A L - Product Description..................................................................................................................4 1.1 Equipment Description...................................................................................................................................4 1.2 Equipment Marking Plate...............................................................................................................................4 1.3 Device Configuration During Test..................................................................................................................5 1.3.1 Equipment Used During Test:....................................................................................................................5 1.3.2 Input/Output Ports:.....................................................................................................................................5 1.3.3 EUT Internal Operating Frequencies:........................................................................................................5 1.3.4 Power Interface:.........................................................................................................................................5 1.4 Block Diagram:...............................................................................................................................................6 1.5 EUT Configurations........................................................................................................................................6 1.6 EUT Operation Modes....................................................................................................................................6 2.0 Summary............................................................................................................................................................7 2.1 Deviations from standard test methods..........................................................................................................7 2.2 Device Modifications Necessary for Compliance...........................................................................................7 2.3 Reference Standards.....................................................................................................................................8 2.4 Results Summary...........................................................................................................................................8 3.0 Calibration of Equipment Used for Measurement..............................................................................................9 4.0 Emissions Test Results......................................................................................................................................9 4.1 Test Conditions and Results – CONDUCTED POWER.............................................................................10 4.2 Test Conditions and Results – SPURIOUS EMISSIONS – Antenna Port Conducted...............................13 4.3 Test Conditions and Results – SPURIOUS EMISSIONS – Radiated (>1 GHz).........................................20 4.4 Test C…
Text truncated - open the document above for the full version.
Project Number: 10CA28335 File Number: MC16580 Page 1 of 3 Model Number: CMGYZHPECD 3.0 (Gateway for GE I-210 series meter) Client Name: Consert Inc. FCC ID: YJ4CMGYZHPECD30 Test setup for CONDUCTED POWER / SPURIOUS EMISSIONS at0 Antenna Port Conducted Measurement Setup (EUT removed from case for port access) Underwriters Laboratories Inc. 12 Laboratory Dr. Research Triangle Park, NC 27709 USA Tel.: 919 549-1400 Rev. No 1.0 EMC Report 2007 Project Number: 10CA28335 File Number: MC16580 Page 2 of 3 Model Number: CMGYZHPECD 3.0 (Gateway for GE I-210 series meter) Client Name: Consert Inc. FCC ID: YJ4CMGYZHPECD30 Test setup for RADIATED SPURIOUS EMISSIONS EUT Upright (On Bottom) EUT On Side EUT on Back (Flat) Underwriters Laboratories Inc. 12 Laboratory Dr. Research Triangle Park, NC 27709 USA Tel.: 919 549-1400 Rev. No 1.0 EMC Report 2007 Project Number: 10CA28335 File Number: MC16580 Page 3 of 3 Model Number: CMGYZHPECD 3.0 (Gateway for GE I-210 series meter) Client Name: Consert Inc. FCC ID: YJ4CMGYZHPECD30 Underwriters Laboratories Inc. 12 Laboratory Dr. Research Triangle Park, NC 27709 USA Tel.: 919 549-1400 Rev. No 1.0 EMC Report 2007 Figure 1 Test Setup for Conducted Emissions
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 11.50 mW |

Stand Alone Gateway
Equipment Class
DTS - Digital Transmission System
Zigbee Modular Device
Equipment Class
DTS - Digital Transmission System