FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Kichler Lighting LLC/
  3. YNE-65GENTR

YNE-65GENTRGentry LED 65in Fan

Kichler Lighting LLC
Gentry LED 65in Fan - FCC ID YNE-65GENTR - Kichler Lighting LLC
Click to zoom

Application Details

Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Date of Grant
May 18, 2021
Application Purpose
Original Equipment
Date of Application
May 18, 2021
Equipment Note
Gentry LED 65in Fan
Frequency Range
303.87200000 - 303.87200000
Company
Kichler Lighting LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

65" G @ TRY INSTRUCTION MANUAL Product images may vary slightly from actual product. REV 12-MAY-2021 Net Weight:12.65KGS Gross Weight:15.40KGS cUL Model:300265/CP183212/65-GENT TABLE OF CONTENTS SAFET Y RULES .......................................................................... 4 55 6 7 10 11 13 1414 TOOLS REQUIRED .................................................................... PACKAGE CONTENTS ............................................................. MOUNTING OPTIONS ............................................................. HANGING THE FAN .................................................................. INSTALLATION OF SAFET Y SUPPORT .......................... ELECTRICAL CONNECTIONS ............................................. FINISHING THE INSTALLATION ........................................ INSTALLING THE LIGHT PLATE ........................................ INSTALLING THE LED LIGHT KITAND GLASS SHADE ASSEMBLY ...................................... 15 16 17 18 19 20 21 CONTROL SYSTEM SET-UP ............................................... BUTTON INSTRUCTION ........................................................ INSTALLING THE WALL CONTROLSYSTEM WALL PLATE ........................................................... OPERATION INSTRUCTIONS ............................................ TROUBLESHOOTING ............................................................ 65" GENTRY | 3 ATTACHING THE FAN BLADES .......................................... SENSORLESS DC CONTROL PAIRING PROCEDURES ........................................................................... 2 Ě ! ƣ*@!FT?^*F@ .... ƇƇƇ ........................................................ 4 | KICHLER.COM  before installation. 15. All set screws must be checked, and retightened where necessary                                         your fan. WARNING: make sure the power is disconnected before cleaning should be performed by a qualified licensed electrian. ANSI/NFPA 70 and local electrical codes. Electrical installation should All wiring must be in accordance with the National Electrical Code Use only with light kits marked suitable for damp location.  !     "      #$                        The fan must be mounted with a minimum of 2.1m(7 feet)  6. 14. Suitable for damp location. 13. 4. X!^tƣTb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hilips screw driverBlade screw driver11 mm wrenchStep ladderWire cutters PACKAGE CONTENTS i j k f gh b c d e Unpack your fan and check the contents. You should have the following items: ~Ƈ Fan blades (9) ‰Ƈ Blade support plates (9) ŠƇ Canopy & Ceiling mounting bracket Ƈ Ball/downrod assembly ”Ƈ Coupling cover žƇ Fan motor assembly ŸƇ Light plate ¤Ƈ 1 ğ W LED light kit §Ƈ Glass shade assembly ³Ƈ Wall Transmitter k. Part bag contents1) Mounting hardware: star washers (2), wire nuts (3), machine screws (2), washers (2), screws (2) 2) Blade attachment hardware: screws (29) 3) Safety cable hardware: wood screw, lock washer, flat washer 4) Balance Kit a 65" GENTRY | 5 6 | KICHLER.COM MOUNTING OPTIONS If there isn't an existing UL (cUL for Canadian Installation) listed mounting box, then read the following instructions. Disconnect the power by removing fuses or turning off circuit breakers.Secure the outlet box directly to the building structure. Use appropriate fasteners and building materials. The outlet box and its support must be able to fully support the žä¹¹ weight of the fan (at least 50 lbs). Do not use plastic outlet boxes.Figures 1, 2 and 3 are examples of different ways to mount the outlet box.NOTE: If you are installing the ceiling fan on a sloped (vaulted) ceiling, …

Text truncated - open the document above for the full version.

Attestation Statements

Kichler Lighting 7711 East Pleasant Valley Road, Cleveland, Ohio, 44131, United States Tel.: 216.573.1005 Extension: 6543 Fax: 216.901.5611 Statement We Kichler Lighting Hereby Declare that The product Gentry LED 65in Fan models no. 300265, CP183212 and 65-GENT are all identical in interior structure, electrical circuits and components, and model names are different for the marketing requirement. The device have left and right earphones ,the left and right earphones are electrically identical. Your assistance on this matter is highly appreciated. Yours sincerely, Signature: Company Name: Kichler Lighting

Cover Letter(s)

May 17, 2021 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Shenzhen Timeway Testing Laboratories/ Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China. (Name of Agent company name and address) to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with Kichler Lighting/ 7711 East Pleasant Valley Road, Cleveland, Ohio, 44131, United States Dated this May 17, 2021 Agency agreement expiration date:Usually Give 8 -12 Months By: Gregory Prosser Si gnature Printed Title: Manager Product Specifications and Compliance On behalf of : Kichler Lighting Telephone: 216.573.1005 Extension: 6543

Cover Letter(s)

May 17, 2021 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: YNE-65GENTR Product Name: Gentry LED 65in Fan Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: • Schematics • Block diagram • Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature>: Name:Gregory Prosser Title:Manager Product Specifications and Compliance Company:Kichler Lighting

ID Label/Location Info

6 5 - G E N T . R O O L F O T S E D A B L K S I R E C U D E R O : T - T N I A , M S N O S R E P O T Y R J U I N O F 6 6 4 3 1 - A 2 9 3 6 1 H 5 1 50.00 mm 3 0 . 0 0 m m YNE-65GENTR

ID Label/Location Info

Label Location

Test Report

Report No.: TW2104063-01E File Reference No.: 2021-04-23 Applicant: Kichler Lighting Product: Gentry LED 65in Fan Brand Name: KICHLER Model No.: 300265, CP183212, 65-GENT Test Standards: FCC Part 15 Subpart B Test Result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.4&FCC Part 15 regulations for the evaluation of electromagnetic compatibility Approved By Terry Tong Manager Dated: April 23, 2021 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TESTING LABORATORIES. Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China Tel (755) 83448688 Fax (755) 83442996 Email: [email protected] Report No.: TW2104063-01E Page 2 of 27 Date: 2021-04-23 "The report refers only to the sample tested and does not apply to the bulk production. This report is issued in confidential to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for illegal purpose. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES reserves the rights to withdraw it and to adopt any other remedies which may be appropriate." Special Statement: The testing quality ability of our laboratory meet with "Quality Law of People's Republic of China" Clause 19. The testing quality system of our laboratory meet with ISO/IEC-17025 requirements, which is approved by CNAS. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAS-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAS-CL01 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:2005 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 744189 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 744189. Industry Canada (IC) —Registration No.:5205A The EMC Laboratory has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 5205A. A2LA (Certification Number:5013.01) The EMC Laboratory has been accredited by the American Association for Laboratory Accreditation (A2LA). Certification Number:5013.01 Report No.: TW2104063-01E Page 3 of 27 Date: 2021-04-23 "The report refers only to the sample tested and does not apply to the bulk production. This report is issued in confidential to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for illegal purpose. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES reserves the rights to withdraw it and to adopt any other remedies which may be appropriate." Content 1.0 General Details ................................................................................................................................................ 4 1.1 Test Lab Details ........................................................................................................................................ 4 1.2 Applicant Details ...................................................................................................................................... 4 1.4 Submitted Sample: 1 Sample .................................................................................................................... 4 1.5 Test Duration ............................................................................................................................................ 4 1.6 Test Uncertainty ........................................................................................................................................ 4 1.7 Test Engineer ............................................................................................................................................ 4 2.0 List of Measurement Equipment ................................................................................................................... 5 2.1 Conducted Emission Test .......................................................................................................................... 5 2.2 Radiated electromagnetic disturbance test ................................................................................................ 5 2.3 Auxiliary Equipment ................................................................................................................................ 5 3.0 Technical Details ............................................................................................................................................. 6 3.1 Investigations Requested .......................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted Emission Test Setup: Radiated Emission Test Setup:

Contact Information

Applicant

John Noble(Lead Certification Engineer)
[email protected]216.573.1005Fax: NA

Test Firm

Shenzhen Timeway Testing LaboratoriesTerry Tang
[email protected]+86-755-83448688

Technical Specifications

#Rule PartsFrequency RangePower Output
115B303.872 MHz - 303.872 MHz-
Confidentiality
Long Term

Other Applications from Kichler Lighting LLC

CEILING FAN WALL CONTROL - FCC ID YNE-000170-12 - Kichler Lighting LLC
YNE-000170-12

CEILING FAN WALL CONTROL

Aug 12, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
CEILING FAN REMOTE CONTROL - FCC ID YNE-000170-04 - Kichler Lighting LLC
YNE-000170-04

CEILING FAN REMOTE CONTROL

Sep 20, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Landscape Smart Transformer - FCC ID YNE-000081-001 - Kichler Lighting LLC
YNE-000081-001

Landscape Smart Transformer

Jun 05, 2023

Equipment Class

DTS - Digital Transmission System
Gentry XL  LED 85in Fan - FCC ID YNE-85GENTR - Kichler Lighting LLC
YNE-85GENTR

Gentry XL LED 85in Fan

May 19, 2021

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
SMART WIFI SOCKET - FCC ID YNE16085BK - Kichler Lighting LLC
YNE16085BK

SMART WIFI SOCKET

Feb 04, 2021

Equipment Class

DTS - Digital Transmission System