Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Cambium PMP 450 Configuration and User Guide System Release 12.0 pmp-0050 (May 2012) Accuracy While reasonable efforts have been made to assure the accuracy of this document, Cambium Networks assumes no liability resulting from any inaccuracies or omissions in this document, or from use of the information obtained herein. Cambium reserves the right to make changes to any products described herein to improve reliability, function, or design, and reserves the right to revise this document and to make changes from time to time in content hereof with no obligation to notify any person of revisions or changes. Cambium does not assume any liability arising out of the application or use of any product, software, or circuit described herein; neither does it convey license under its patent rights or the rights of others. It is possible that this publication may contain references to, or information about Cambium products (machines and programs), programming, or services that are not announced in your country. Such references or information must not be construed to mean that Cambium intends to announce such Cambium products, programming, or services in your country. Copyrights This document, Cambium products, and 3rd Party Software products described in this document may include or describe copyrighted Cambium and other 3rd Party supplied computer programs stored in semiconductor memories or other media. Laws in the United States and other countries preserve for Cambium, its licensors, and other 3rd Party supplied software certain exclusive rights for copyrighted material, including the exclusive right to copy, reproduce in any form, distribute and make derivative works of the copyrighted material. Accordingly, any copyrighted material of Cambium, its licensors, or the 3rd Party software supplied material contained in the Cambium products described in this document may not be copied, reproduced, reverse engineered, distributed, merged or modified in any manner without the express written permission of Cambium. Furthermore, the purchase of Cambium products shall not be deemed to grant either directly or by implication, estoppel, or otherwise, any license under the copyrights, patents or patent applications of Cambium or other 3rd Party supplied software, except for the normal non-exclusive, royalty free license to use that arises by operation of law in the sale of a product. Restrictions Software and documentation are copyrighted materials. Making unauthorized copies is prohibited by law. No part of the software or documentation may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, without prior written permission of Cambium. License Agreements The software described in this document is the property of Cambium and its licensors. It is furnished by express license agreement only and may be used only in accordance with the terms of such an agreement. High Risk Materials Components, units, or 3rd Party products used in the product described herein are NOT fault-tolerant and are NOT designed, manufactured, or intended for use as on-line control equipment in the following hazardous environments requiring fail-safe controls: the operation of Nuclear Facilities, Aircraft Navigation or Aircraft Communication Systems, Air Traffic Control, Life Support, or Weapons Systems (High Risk Activities). Cambium and its supplier(s) specifically disclaim any expressed or implied warranty of fitness for such High Risk Activities. © 2009 – 2012 Cambium Networks, Inc. All Rights Reserved. PMP 450 Configuration and User Guide pmp-0050 (May 2012) I Safety and regulatory information This section describes important safety and regulatory guidelines that must be observed by personnel installing or operating PMP 450 equipment. Important safety information To prevent loss of life or physical injury, observe the safety guidelines in this section. Power lines Exercise extreme care when working near power lines. Working at heights Exercise extreme care when working at heights. Grounding and protective earth PMP 450 units must be properly grounded to protect against lightning. It is the user‘s responsibility to install the equipment in accordance with national regulations. In the USA, follow Section 810 of the National Electric Code, ANSI/NFPA No.70-1984 (USA). In Canada, follow Section 54 of the Canadian Electrical Code. These codes describe correct installation procedures for grounding the outdoor unit, mast, lead-in wire and discharge unit, size of grounding conductors and connection requirements for grounding electrodes. Other regulations may apply in different countries and therefore it is recommended that installation of the outdoor unit be contracted to a professional installer. Powering down before servicing Always power down and unplug the equipment before servicing. Primary disconnect device The main power supply is the primary disconnect device. External cables Safety may be compromised if outdoor rated cables are not used for connections that will be exposed to the outdoor environment. Safety and regulatory information II pmp-0050 (May 2012) RF exposure near the antenna Strong radio frequency (RF) fields will be present close to the antenna when the transmitter is on. Always turn off the power to the PMP 450 unit before undertaking maintenance activities in front of the antenna. Minimum separation distances Install the units so as to provide and maintain the minimum separation distances from all persons. Important regulatory information The PMP 450 product is certified as an unlicensed device in frequency bands where it is not allowed to cause interference to licensed services (called primary users of the bands). Radar avoidance In countries where radar systems are the primary band users, the regulators have mandated special requirements to protect these systems from interference caused by unlicensed devices. Unlicens…
Text truncated - open the document above for the full version.
PMP 450 Configuration and User Guide pmp-0050 (May 2012) 3-1 Exposure Separation Distances To protect from overexposure to RF energy, install PMP 450 radios so as to provide and maintain the minimum separation distances from all persons shown in Table 64. Table 64 Exposure Separation Distances Module Type Separation Distance from Persons PMP 450 AP or SM At least 20 cm (approx 8 in) Details of Exposure Separation Distances Calculations and Power Compliance Margins Limits and guidelines for RF exposure come from: US FCC limits for the general population. See the FCC web site at http://www.fcc.gov, and the policies, guidelines, and requirements in Part 1 of Title 47 of the Code of Federal Regulations, as well as the guidelines and suggestions for evaluating compliance in FCC OET Bulletin 65. Health Canada limits for the general population. See Safety Code 6 on the Health Canada web site at http://www.hc-sc.gc.ca/. ICNIRP (International Commission on Non-Ionizing Radiation Protection) guidelines for the general public. See the ICNIRP web site at http://www.icnirp.de/ and Guidelines for Limiting Exposure to Time- Varying Electric, Magnetic, and Electromagnetic Fields. The applicable power density exposure limits from the documents referenced above are 10 W/m2 for RF energy in the 5.7-GHz frequency band. Peak power density in the far field of a radio frequency point source is calculated as follows: S PG 4d 2 where S = power density in W/m 2 P = RMS transmit power capability of the radio, in W G = total Tx gain as a factor, converted from dB d = distance from point source, in m Rearranging terms to solve for distance yields d PG 4S Table 65 shows calculated minimum separation distances d, recommended distances and resulting power compliance margins for each frequency band and antenna combination. Exposure Separation Distances Chapter 1: 3-2 pmp-0050 (May 2012) Table 65 Calculated Exposure Distances and Power Compliance Margins Freq. Band Antenna Variable d (calc u- lated) Recom- mended Separati on Distance Power Compliance Margin P G S 5.4 / 5.8 GHz OFDM Integrated, 9 dBi patch 0.079 W (19 dBm) .08 W (9 dBi) 10 W/m 2 or 1 mW/c m 2 8 cm 20 cm (8 in) 8 Integrated, 9 dBi patch with 9 dBi Cassegrain LENS 0.079 W (19 dBm) .05 W (18 dBi) 10 W/m 2 or 1 mW/c m 2 18 cm 50 cm (20 in) 8 Integrated, 9 dBi patch with 18 dBi Reflector Dish 0.079 W (19 dBm) .5 W (27 dBi) 10 W/m 2 or 1 mW/c m 2 56 cm 150 cm (60 in) 7 The ―Recommended Distances‖ are chosen to give significant compliance margin in all cases. They are also chosen so that an OFDM module has the same exposure distance as a Canopy module, to simplify communicating and heeding exposure distances in the field. These are conservative distances: They are along the beam direction (the direction of greatest energy). Exposure to the sides and back of the module will be significantly less. They meet sustained exposure limits for the general population (not just short term occupational exposure limits), with considerable margin. The calculated compliance distance d is overestimated because the far-field equation models the antenna as a point source and neglects the physical dimension of the antenna.
166 South Carter, Genoa City, WI 53128 Page 1 of 282 Company: Cambium Networks Model Tested: C054045C004A Report Number: 17831 i. Cover Page Code of Federal Regulations 47 Part 15 – Radio Frequency Devices Subpart C – Intentional Radiators Section 15.247 Operation within the bands 902 - 928 MHz, 2400 - 2483.5 MHz, 5725 - 5875 MHz, and 24.0 - 24.25 GHz. And Industry Canada Spectrum Management and Telecommunications Radio Standards Specification RSS-210 Issue 8 December 2010 PART I – 10 MHz Bandwidth Data THE FOLLOWING MEETS THE ABOVE TEST SPECIFICATION Formal Name: PMP450SM 5.7GHz OFDM Radio with cross-polarized antenna Kind of Equipment: Point-to-Point Digital Transmission Transceiver Frequency Range: 5.730 to 5.845 MHz (10 MHz bandwidth) 5.735 to 5.840 MHz (20 MHz bandwidth) Test Configuration: Stand-alone Model Number(s): C054045C001A, C054045C002A, C054045C003A, C054045C004A Model(s) Tested: C054045C004A Serial Number(s): 0A003EA00037 (integrated), 0A003EA00047 (connectorized) Date of Tests: April 2 nd to May 1 st , 2012 Test Conducted For: Cambium Networks 1299 E. Algonquin Road. Schaumburg, IL 60196, USA NOTICE: “This test report relates only to the items tested and must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government”. Please see the "Description of Test Sample" page listed inside of this report. © Copyright 1983 – 2012, D.L.S. Electronic Systems, Inc. COPYRIGHT NOTICE This report must not be reproduced (except in full), without the approval of D.L.S. Electronic Systems, Inc. 166 South Carter, Genoa City, WI 53128 Page 2 of 282 Company: Cambium Networks Model Tested: C054045C004A Report Number: 17831 ii. Signature Page SIGNATURE PAGE Tested By: Craig Brandt Test Engineer Reviewed By: William Stumpf OATS Manager Approved By: Brian Mattson General Manager 166 South Carter, Genoa City, WI 53128 Page 3 of 282 Company: Cambium Networks Model Tested: C054045C004A Report Number: 17831 iii. Table of Contents Table of Contents i. Cover Page ..............................................................................................................................................1 ii. Signature Page .........................................................................................................................................2 iii. Table of Contents ....................................................................................................................................3 iv. NVLAP Certificate of Accreditation .......................................................................................................4 1.0 Summary of Test Report ..................................................................................................................5 2.0 Introduction ......................................................................................................................................6 3.0 Test Facilities ...................................................................................................................................6 4.0 Description of Test Sample ..............................................................................................................6 5.0 Test Equipment ................................................................................................................................8 6.0 Test Arrangements ...........................................................................................................................9 7.0 Test Conditions ................................................................................................................................9 8.0 Modifications Made To EUT for Compliance ...............................................................................10 9.0 Additional Descriptions .................................................................................................................10 10.0 Results ............................................................................................................................................10 11.0 Conclusion .....................................................................................................................................10 Appendix A – Measurement Data ..............................................................................................................11 A1.0 26 dB Emission Bandwidth - Conducted .................................................................................. 11 A2.0 Emission Bandwidth – 6 dB bandwidth - conducted ................................................................ 30 A3.0 Fundamental Emission Output Power - Conducted .................................................................. 49 A4.0 Maximum Power Spectral Density – Conducted ...................................................................... 68 A5.0 Maximum Unwanted Emission Levels – Conducted ............................................................... 87 A6.0 Maximum Unwanted Emission Levels into Restricted Frequency Bands – Radiated ........... 196 A7.0 Maximum Unwanted Emission Levels – Conducted Band-Edge .......................................... 245 A8.0 Duty Cycle of Test Unit .......................................................................................................... 270 A9.0 AC Line Conducted Emissions ............................................................................................... 277 166 South Carter, Genoa City, WI 53128 Page 4 of 282 Company: Cambium Networks Model Tested: C054045C004A Report Number: 17831 iv. NVLAP Certificate of Accreditation 166 South Carter, Genoa City, WI 53128 Page 5 of 282 Company: Cambium Networks Model Tested: C054045C004A Report Number: 17831 1.0 Summary of Test Report It was determ ined that the Cambium Networks PMP450SM 5.7GHz OFDM Radio with cross-polarized antenna, Model C054045C004A, complies with the requirements of CFR 47 Part 15 Subpart C Section 15.247 and Indust…
Text truncated - open the document above for the full version.
166 South Carter, Genoa City, WI 53128 Page 1 of 282 Company: Cambium Networks Model Tested: C054045C004A Report Number: 17833 i. Cover Page Code of Federal Regulations 47 Part 15 – Radio Frequency Devices Subpart C – Intentional Radiators Section 15.247 Operation within the bands 902 - 928 MHz, 2400 - 2483.5 MHz, 5725 - 5875 MHz, and 24.0 - 24.25 GHz. And Industry Canada Spectrum Management and Telecommunications Radio Standards Specification RSS-210 Issue 8 December 2010 PART II – 20 MHz Bandwidth Data THE FOLLOWING MEETS THE ABOVE TEST SPECIFICATION Formal Name: PMP450SM 5.7GHz OFDM Radio with cross-polarized antenna Kind of Equipment: Point-to-Point Digital Transmission Transceiver Frequency Range: 5.730 to 5.845 MHz (10 MHz bandwidth) 5.735 to 5.840 MHz (20 MHz bandwidth) Test Configuration: Stand-alone Model Number(s): C054045C001A, C054045C002A, C054045C003A, C054045C004A Model(s) Tested: C054045C004A Serial Number(s): 0A003EA00037 (integrated), 0A003EA00047 (connectorized) Date of Tests: April 2 nd to May 1 st , 2012 Test Conducted For: Cambium Networks 1299 E. Algonquin Road. Schaumburg, IL 60196, USA NOTICE: “This test report relates only to the items tested and must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government”. Please see the "Description of Test Sample" page listed inside of this report. © Copyright 1983 – 2012, D.L.S. Electronic Systems, Inc. COPYRIGHT NOTICE This report must not be reproduced (except in full), without the approval of D.L.S. Electronic Systems, Inc. 166 South Carter, Genoa City, WI 53128 Page 2 of 282 Company: Cambium Networks Model Tested: C054045C004A Report Number: 17833 ii. Signature Page SIGNATURE PAGE Tested By: Craig Brandt Test Engineer Reviewed By: William Stumpf OATS Manager Approved By: Brian Mattson General Manager 166 South Carter, Genoa City, WI 53128 Page 3 of 282 Company: Cambium Networks Model Tested: C054045C004A Report Number: 17833 iii. Table of Contents Table of Contents i. Cover Page ..............................................................................................................................................1 ii. Signature Page .........................................................................................................................................2 iii. Table of Contents ....................................................................................................................................3 iv. NVLAP Certificate of Accreditation .......................................................................................................4 1.0 Summary of Test Report ..................................................................................................................5 2.0 Introduction ......................................................................................................................................6 3.0 Test Facilities ...................................................................................................................................6 4.0 Description of Test Sample ..............................................................................................................6 5.0 Test Equipment ................................................................................................................................8 6.0 Test Arrangements ...........................................................................................................................9 7.0 Test Conditions ................................................................................................................................9 8.0 Modifications Made To EUT for Compliance ...............................................................................10 9.0 Additional Descriptions .................................................................................................................10 10.0 Results ............................................................................................................................................10 11.0 Conclusion .....................................................................................................................................10 Appendix A – Measurement Data ..............................................................................................................11 A1.0 26 dB Emission Bandwidth - Conducted .................................................................................. 11 A2.0 Emission Bandwidth – 6 dB bandwidth - conducted ................................................................ 30 A3.0 Fundamental Emission Output Power - Conducted .................................................................. 49 A4.0 Maximum Power Spectral Density – Conducted ...................................................................... 68 A5.0 Maximum Unwanted Emission Levels – Conducted ............................................................... 87 A6.0 Maximum Unwanted Emission Levels into Restricted Frequency Bands – Radiated ........... 196 A7.0 Maximum Unwanted Emission Levels – Conducted Band-Edge .......................................... 245 A8.0 Duty Cycle of Test Unit .......................................................................................................... 270 A9.0 AC Line Conducted Emissions ............................................................................................... 277 166 South Carter, Genoa City, WI 53128 Page 4 of 282 Company: Cambium Networks Model Tested: C054045C004A Report Number: 17833 iv. NVLAP Certificate of Accreditation 166 South Carter, Genoa City, WI 53128 Page 5 of 282 Company: Cambium Networks Model Tested: C054045C004A Report Number: 17833 1.0 Summary of Test Report It was determ ined that the Cambium Networks PMP450SM 5.7GHz OFDM Radio with cross-polarized antenna, Model C054045C004A, complies with the requirements of CFR 47 Part 15 Subpart C Section 15.247 and Indus…
Text truncated - open the document above for the full version.
Company: Cambium Networks Model Tested: C054045C004A 166 South Carter, Genoa City, WI 53128 Report Numbers: 17831 & 17833 Test Setup Photos Photo Information and Test Setup: Item0: PMP450SM 5.7GHz OFDM Radio with cross-polarized antenna, Model C054045C004A Item1: Non-shielded Ethernet cable, 15 meters long with plastic connectors Radiated Emissions – Front, with Patch Antenna Company: Cambium Networks Model Tested: C054045C004A 166 South Carter, Genoa City, WI 53128 Report Numbers: 17831 & 17833 Test Setup Photos Radiated Emissions – Back, with Patch Antenna Company: Cambium Networks Model Tested: C054045C004A 166 South Carter, Genoa City, WI 53128 Report Numbers: 17831 & 17833 Test Setup Photos Radiated Emissions –with Cassegrain Lens Antenna Company: Cambium Networks Model Tested: C054045C004A 166 South Carter, Genoa City, WI 53128 Report Numbers: 17831 & 17833 Test Setup Photos Radiated Emissions –with Dish Antenna Company: Cambium Networks Model Tested: C054045C004A 166 South Carter, Genoa City, WI 53128 Report Numbers: 17831 & 17833 Test Setup Photos Radiated Emissions – above 1 GHz with Patch Antenna Company: Cambium Networks Model Tested: C054045C004A 166 South Carter, Genoa City, WI 53128 Report Numbers: 17831 & 17833 Test Setup Photos Radiated Emissions – above 1 GHz with Cassegrain Lens Antenna Company: Cambium Networks Model Tested: C054045C004A 166 South Carter, Genoa City, WI 53128 Report Numbers: 17831 & 17833 Test Setup Photos Radiated Emissions – above 1 GHz with Dish Antenna Company: Cambium Networks Model Tested: C054045C004A 166 South Carter, Genoa City, WI 53128 Report Numbers: 17831 & 17833 Test Setup Photos RF Conducted Emissions Company: Cambium Networks Model Tested: C054045C004A 166 South Carter, Genoa City, WI 53128 Report Numbers: 17831 & 17833 Test Setup Photos AC Line Conducted Emissions
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 5.73 GHz - 5.84 GHz | 79.00 mW |
X7-56X Indoor Wi-Fi 7 Tri-band 4x4 AP, 60deg
Equipment Class
6ID - 15E 6 GHz Low Power Indoor Access Point6092HH
Equipment Class
NII - Unlicensed National Information Infrastructure TX
6091HH
Equipment Class
NII - Unlicensed National Information Infrastructure TX
6084HH
Equipment Class
NII - Unlicensed National Information Infrastructure TX
6094HH
Equipment Class
NII - Unlicensed National Information Infrastructure TX