Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Apr 23, 2013
Application Purpose
Original Equipment
Date of Application
Apr 23, 2013
Equipment Note
Industrial Cellular Router
Frequency Range
826.40000000 - 846.60000000
Company
Beijing InHand Networks Technology Co,. Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

InRouter 6X5 Series Compact Design: 4 Ethernet LAN switch ports, RS232/485 (DB9), 3G/UMTS or Ethernet WAN connection Power supply: 9-26V DC Power Terminal High security: Advanced VPN (IPSec/SSL/GRE/L2TP/PPTP) Centralized management platform: InHand Device Manager Cloud Reliable for almost all industrial conditions Smart 4 Ethernet LAN/ Serial to Ethernet WAN/HSPA+/UMTS Router Ove r vi ew InRouter6X5 series are compact designed industrial cellular routers which can help users to quickly access to high-speed Internet and support secure and reliable data transmission. The products combine together with the functions of unmanaged switch, serial server, 3G Router, IP modem, Advanced VPN client and provide with high cost-effective solution for applications in industrial automation and control, fleet monitoring, video surveillance, advertising media, and outlets networking. You can even configure it easily through the browser on your IOS or Android terminals without connection to the router by cable. Besides flexibility, InRouter6X5 series can provide reliable data link. For example, the multi-level linkage detection ensures linkage stability especially for applications in unattended areas. The outstanding performance under wide temperature and harsh electromagnetic field enables the capability to work under harsh conditions. The most amazing thing is InRouter6x5 support almost the VPN security protocols which only exist in advanced VPN Routers. It is compatible with the major VPN routers including the brands of Cisco, HuaWei, Juniper etc. S p ec if ica t i on Interfaces WAN Interfaces Ethernet WAN: Static IP/PPPoE/DHCP Client Cellular WAN: HSPA+: 21Mbps (DL)/5.76Mbps (UL) GSM/GPRS/EDGE: 850/900/1800/1900 MHz UMTS /HSPA/HSPA+: 850/900/1900/2100 MHz LAN Interfaces Auto Adaption: 4 10M/100M Ethernet ports, auto-adaptive MDI/MDI-X auto crossover Isolation Protection: 1.5KV isolation protection Power supply 9-26V DC 5.08mm 2pin Terminal power supply Serial ports Number: 1 RS232/RS485 DB9 Protocol: Modbus RTU, Transparent TCP, Virtual COM Environmental Operating temperature: -20°C~70°C Storage temperature:-40°C ~85°C Humidity: 5%~95%, no-condensing Protection grade: IP40 EMC ESD: EN61000-4-2 Surge: EN61000-4-5 EFT: EN61000-4-4 RF: EN61000-4-3 RC: EN61000-4-6 Oscillatory Wave Immunity: EN61000-4-12 Variation Magnetic Field Immunity: EN61000-4-8 Safety Anti-shock:IEC60068-2-27 Anti-drop: IEC60068-2-32 Anti-vibration: IEC60068-2-6 Reliable Network Link Built-in hardware watchdog, self-recovery PPP link detection disaster self-recovery Professional upgrades mechanism, assure upgrade safety Firewall security service State Packet Inspection, anti-DoS attacks, Filter multicast Filter ping, Access control list Configuration DB9 Console port, Telnet, and Web configuration Upgrade Remote upgrade and web upgrade, utilizing redundant backup mechanism for worry-free upgrade Network Function Network Address Translation (NAT) and Port Address Translation (PAT) Deny illegitimate host access TCP/IP Protocols ICMP, IP, TCP, UDP, DHCP, PPP, ARP, Telnet, DNS, VRRP, HTTP, HTTPS, VPN (IPSec/SSL/PPTP/L2TP/GRE) Installation Optional Wall mounting kits or DIN mounting Kits Warranty Warranty Period: 1 year, for more period please contact InHand sales Dimensions (Unit: mm) Side View Front View Back View DB9 RS232 /RS485 Port RS232 RS485 Device Manager Cloud FCC STATEMENT 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is Model IR6x5 Part Number IR6<X>5-<N>-<P>-<S> X (Option VPN) 0: standard router; 9: VPN, support IPSec/SSL/PPTP/L2TP/GRE N (Network) UE00: No wireless module WH01: UMTS/HSDPA (850/900/1900/2100 MHz) VZ16:CDMA2000 EVDO\1X( 800MHz/1900MHz/2100MHz) VZ01: EVDO(800MHz/1900MHz. for China/India only) PH01:HSPA+ (850/900/1900/2100 MHz) S (Serial port) <NA> : RS232 485 : RS485 Example IR6 9 5 WH01: UMTS/HSDPA, Support VPN(IPSec/SSL/PPTP/L2TP/GRE) , RS232 serial port O rde r I nf or ma t io n F C C War n in g St at em e nt Connecting Devices, Enabling Services [email protected] connected. Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body

Attestation Statements

Declaration letter Beijing InHand Networks Technology Co., Ltd Main model: IR615PH01 Serial Model: IR605PH01 IR695PH01 IG605PH01 IG615PH01 IG695PH01 The six models have Wi-Fi module on their PCB, but their Wi-Fi function is disabled by default and their software system don’t support Wi-Fi function settings ,so the users can’t open and use WiFi function. Signature: Printed name/title:Wangbiao/ EMC engineer Address: WestWing 11th Floor, Buiding G, Wangjing Science Park, Chaoyang District, Beijing

Cover Letter(s)

SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (current) 2.0 3.0 Jan-31-2012 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 3.0 Beijing InHand Networks Technology Co,. Ltd. _________________________________________________ 2013.4.11 To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, _____Beijing InHand Networks Technology Co,. Ltd._____hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): Product description: Industrial Cellular Router model name: IR615PH01 IR605PH01 IR695PH01 IG605PH01 IG615PH01 IG695PH01 FCC ID: ZAZIR6X5P We affirm that between SIEMIC and ____ Beijing InHand Networks Technology Co,. Ltd. ___, any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Client’s signature Client’s name / title : Jason Hu/Technology Engineer Contact information / address : Beijing InHand Networks Technology Co,. Ltd. West Wing, 11th Floor, Building G, Wang Jing Science Park, Chaoyang District, Beijing, China

Cover Letter(s)

SCS-F19: Confidentiality Request Letter Page 1 of 3 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (current) 2.0 3.0 Jan-31-2012 SCS-F19: Confidentiality Request Letter Page 2 of 3 Rev 3.0 Beijing InHand Networks Technology Co,. Ltd. _________________________________________________ 2013.4.11 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: ZAZIR6X5P We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Schematics - Operational Description - Tune up Procedure - Bom The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s signature Client’s name / title : Jason Hu/Technology Engineer Contact information / address : Beijing InHand Networks Technology Co,. Ltd. West Wing, 11th Floor, Building G, Wang Jing Science Park, Chaoyang District, Beijing, China

Cover Letter(s)

Declaration letter Beijing InHand Networks Technology Co., Ltd To: SIEMIC Nanjing (China) Laboratories No.2-1,Longcang Dadao Yuhua Economic Development Zone Nanjing,P.R.China Dear Sir, For our business issue and marketing requirement, we would like to list different models numbers on the CE/FCC certificates and reports, as following: Model No.: IR615PH01 IR605PH01 IR695PH01 IG605PH01 IG615PH01 IG695PH01 The six models are the same in these: appearance, PCB layout, and basic software function;The differences are as follows: Ia6b5PH01 【a】 【b】 R:router G:gateway 0:basic SW function 1:support VPN (IPsec/PPTP/L2TP) 9:support VPN\CA certificate\SSL 【a】, 【b】is software different only; Thank you! Signature: Printed name/title:Wangbiao/ EMC engineer Address: WestWing 11th Floor, Buiding G, Wangjing Science Park, Chaoyang District, Beijing

External Photos

Title: EMC Test Report for Industrial Cellular Router Main Model: IR615PH01 To: FCC Part 15 Subpart B: 2012, ANSI C63.4: 2009 Report No: 13020108-4-FCC-E1-V1 Issue Date: March 20, 2013 Page: 19 of 33 www.siemic.com.cn Annex B. EUT AND TEST SETUP PHOTOGRAPHS Annex B.i. Photograph 1: EUT External Photo Whole Package View Top View of EUT Title: EMC Test Report for Industrial Cellular Router Main Model: IR615PH01 To: FCC Part 15 Subpart B: 2012, ANSI C63.4: 2009 Report No: 13020108-4-FCC-E1-V1 Issue Date: March 20, 2013 Page: 20 of 33 www.siemic.com.cn Bottom View of EUT Front View of EUT Title: EMC Test Report for Industrial Cellular Router Main Model: IR615PH01 To: FCC Part 15 Subpart B: 2012, ANSI C63.4: 2009 Report No: 13020108-4-FCC-E1-V1 Issue Date: March 20, 2013 Page: 21 of 33 www.siemic.com.cn Rear View of EUT Left View of EUT Title: EMC Test Report for Industrial Cellular Router Main Model: IR615PH01 To: FCC Part 15 Subpart B: 2012, ANSI C63.4: 2009 Report No: 13020108-4-FCC-E1-V1 Issue Date: March 20, 2013 Page: 22 of 33 www.siemic.com.cn Right View of EUT

ID Label/Location Info

FCC ID Position FCC ID

Internal Photos

Title: EMC Test Report for Industrial Cellular Router Main Model: IR615PH01 To: FCC Part 15 Subpart B: 2012, ANSI C63.4: 2009 Report No: 13020108-4-FCC-E1-V1 Issue Date: March 20, 2013 Page: 23 of 33 www.siemic.com.cn Annex B.ii. Photograph 2: EUT Internal Photo Cover Off - Front View Antenna View 2G/3G Antenna Title: EMC Test Report for Industrial Cellular Router Main Model: IR615PH01 To: FCC Part 15 Subpart B: 2012, ANSI C63.4: 2009 Report No: 13020108-4-FCC-E1-V1 Issue Date: March 20, 2013 Page: 24 of 33 www.siemic.com.cn 3GModule View for IR615PH01 Main Board Front View Title: EMC Test Report for Industrial Cellular Router Main Model: IR615PH01 To: FCC Part 15 Subpart B: 2012, ANSI C63.4: 2009 Report No: 13020108-4-FCC-E1-V1 Issue Date: March 20, 2013 Page: 25 of 33 www.siemic.com.cn Main Board Rear View

RF Exposure Info

Beijing InHand Networks Technology Co,. Ltd. Industrial Cellular Router Main Model: IR615PH01 Serial Model: Please See Page5 March 20, 2013 Report No.: 13020108-4-FCC-H1 (This report supersedes NONE) Modifications made to the product : None This Test Report is Issued Under the Authority of: Deon Dai Compliance Engineer Alex Liu Technical Manager This test report may be reproduced in full only. Test result presented in this test report is applicable to the representative sample only. Title: RF Exposure Evaluation Report for Industrial Cellular Router Main Model: IR615PH01 Serial Model: Please see page 5 To: FCC 2.1091: 2012 Report No: 13020108-4-FCC-H1 Issue Date: March 20, 2013 Page: 2 of 8 www.siemic.com.cn Laboratory Introduction SIEMIC, headquartered in the heart of Silicon Valley, with superior facilities in US and Asia, is one of the leading independent testing and certification facilities providing customers with one-stop shop services for Compliance Testing and Global Certifications. In addition to testing and certification, SIEMIC provides initial design reviews and compliance management through out a project. Our extensive experience with China, Asia Pacific, North America, European, and international compliance requirements, assures the fastest, most cost effective way to attain regulatory compliance for the global markets . Accreditations for Conformity Assessment Country/Region Accreditation Body Scope USA FCC, A2LA EMC , RF/Wireless , Telecom Canada IC, A2LA, NIST EMC, RF/Wireless , Telecom Taiwan BSMI , NCC , NIST EMC, RF, Telecom , Safety Hong Kong OFTA , NIST RF/Wireless ,Telecom Australia NATA, NIST EMC, RF, Telecom , Safety Korea KCC/RRA, NIST EMI, EMS, RF , Telecom, Safety Japan VCCI, JATE, TELEC, RFTEMI, RF/Wireless, Telecom Mexico NOM, COFETEL, Caniety Safety, EMC , RF/Wireless, Telecom Europe A2LA, NIST EMC, RF, Telecom , Safety Accreditations for Product Certifications Country/Region Accreditation Body Scope USA FCC TCB, NIST EMC , RF , Telecom Canada IC FCB , NIST EMC , RF , Telecom Singapore iDA, NIST EMC , RF , Telecom EU NB EMC & R&TTE Directive Japan MIC, (RCB 208) RF , Telecom Hong Kong OFTA (US002) RF , Telecom Title: RF Exposure Evaluation Report for Industrial Cellular Router Main Model: IR615PH01 Serial Model: Please see page 5 To: FCC 2.1091: 2012 Report No: 13020108-4-FCC-H1 Issue Date: March 20, 2013 Page: 3 of 8 www.siemic.com.cn This page has been left blank intentionally. Title: RF Exposure Evaluation Report for Industrial Cellular Router Main Model: IR615PH01 Serial Model: Please see page 5 To: FCC 2.1091: 2012 Report No: 13020108-4-FCC-H1 Issue Date: March 20, 2013 Page: 4 of 8 www.siemic.com.cn CONTENTS 1. EXECUTIVE SUMMARY & EUT INFORMATION...........................................................................................5 2. TECHNICAL DETAILS ..........................................................................................................................................6 3. MAXIMUM PERMISSIBLE EXPOSURE (MPE) ..................................................................................................7 FCC §2.1091 - MAXIMUM PERMISSIBLE EXPOSURE (MPE)...................................................................................7 Title: RF Exposure Evaluation Report for Industrial Cellular Router Main Model: IR615PH01 Serial Model: Please see page 5 To: FCC 2.1091: 2012 Report No: 13020108-4-FCC-H1 Issue Date: March 20, 2013 Page: 5 of 8 www.siemic.com.cn 1. EXECUTIVE SUMMARY & EUT INFORMATION The purpose of this test programme was to demonstrate compliance of the Beijing InHand Networks Technology Co,. Ltd. Industrial Cellular Router and model: IR615PH01against the current Stipulated Standards. The Industrial Cellular Router has demonstrated compliance with the FCC 2.1091: 2012. EUT Information EUT Description : Industrial Cellular Router Main Model : IR615PH01 Serial Model IR605PH01, IR695PH01, IG605PH01, IG615PH01, IG695PH01 Antenna Gain : GSM/WCDMA: 0.8dBi Input Power : Adapter Model:AW018WR-1200 100CV Input:100-240V 50/60Hz 0.5A Output: 12V 1A EUT Power supply: 9-26V DC Power Terminal Maximum Conducted Peak Power to Antenna : GSM850:32.52dBm PCS1900:28.98dBm Classification Per Stipulated Test Standard : FCC 2.1091: 2012 Title: RF Exposure Evaluation Report for Industrial Cellular Router Main Model: IR615PH01 Serial Model: Please see page 5 To: FCC 2.1091: 2012 Report No: 13020108-4-FCC-H1 Issue Date: March 20, 2013 Page: 6 of 8 www.siemic.com.cn 2. TECHNICAL DETAILS Purpose Compliance testing of Industrial Cellular Router with stipulated standard Applicant / Client Beijing InHand Networks Technology Co,. Ltd. West Wing, 11th Floor, Building G, Wang Jing Science Park, Chaoyang District, Beijing, 100102 China Manufacturer Beijing InHand Networks Technology Co,. Ltd. West Wing, 11th Floor, Building G, Wang Jing Science Park, Chaoyang District, Beijing, 100102 China Laboratory performing the tests SIEMIC Nanjing (China) Laboratories NO.2-1,Longcang Dadao, Yuhua Economic Development Zone, Nanjing, China Tel:+86(25)86730128/86730129 Fax:+86(25)86730127 Email:[email protected] Test report reference number 13020108-4-FCC-H1 Date EUT received March 06, 2013 Standard applied FCC 2.1091: 2012 Dates of test March 15, 2013 No of Units #1 Equipment Category Spread Spectrum System/Device Trade Name N/A RF Operating Frequency (ies) GSM850 TX : 824.2 ~ 848.8 MHz; RX : 869.2 ~ 893.8 MHz PCS1900 TX : 1850.2 ~ 1909.8 MHz; RX : 1930.2 ~ 1989.8 MHz Number of Channels 299CH (PCS1900) and 124CH (GSM850) Modulation GSM / GPRS: GMSK FCC ID ZAZIR6X5P Title: RF Exposure Evaluation Report for Industrial Cellular Router Main Model: IR615PH01 Serial Model: Please see page 5 To: FCC 2.1091: 2012 Report No: 13020108-4-FCC-H1 Issue Date: March 20, 2013 Page: 7 of 8 www.siemic.com.cn 3. MAXIMUM PERMISSIBLE EXPOSURE (MPE) FCC §2.1091 - MAXIMUM PERMISSIBLE EXPOSURE (MPE) Applicable Standard According to §1.1307(b)(1), systems operating under the provisio…

Text truncated - open the document above for the full version.

Test Report

FCC RF Test Report Product Name: HSPA+ Module Model Number: EM820W Report No: SYBHZ(R)E045112010EB-2 FCC ID: QISEM820W IC ID: 6369A-EM820W Reliability Laboratory of Huawei Technologies Co., Ltd. Huawei Base, Bantian, Longgang District, Shenzhen 518129, P.R. China Tel: +86 755 28780808 Fax: +86 755 89652518 FCC Test Report of EM820W FCC ID: QISEM820W IC ID: 6369A-EM820W Report No: SYBHZ(R)E045112010EB-2 Confidential Information of Huawei. No Distribution without Written Permission Page2, Total35 Notice 1. The laboratory has obtained the accreditation of China National Accreditation Service for Conformity Assessment (CNAS), and accreditation number: L0310. 2. The laboratory has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. The site recognition number is 97456. 3. The laboratory has been listed by industry Canada to perform electromagnetic emission measurement. The site recognition number is 6369A-1. 4. The test report is invalid if not marked with "exclusive stamp for the test report". 5. The test report is invalid if not marked with the stamps or the signatures of the persons responsible for performing, revising and approving the test report. 6. The test report is invalid if there is any evidence of erasure and/or falsification. 7. If there is any dissidence for the test report, please file objection to the test centre within 15 days from the date of receiving the test report. 8. Normally, the test report is only responsible for the samples that have undergone the test. 9. Context of the test report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of the laboratory. FCC Test Report of EM820W FCC ID: QISEM820W IC ID: 6369A-EM820W Notice 2 Modification Information: Modification Information 1 2 3 4 5 6 Modification Information 7 Report No: SYBHZ(R)E045112010EB-2 Confidential Information of Huawei. No Distribution without Written Permission Page3, Total35 FCC Test Report of EM820W FCC ID: QISEM820W IC ID: 6369A-EM820W REGULATION FCC CFR47 Part 2: Subpart J; FCC CFR47 Part 22 : Subpart H; RSS-Gen Issue 2 June 2007 RSS-132 Issue 2 September 2005 START OF TEST Nov.23, 2010 END OF TEST Nov.25, 2010 Final Judgement: Pass Approved By Nov.27, 2010 Liuchunlin Date Name Signature Reviewed By Nov.27, 2010 Chenxiaohong Date Name Signature Operator Nov.27, 2010 Zhangting Date Name Signature Report No: SYBHZ(R)E045112010EB-2 Confidential Information of Huawei. No Distribution without Written Permission Page4, Total35 FCC Test Report of EM820W FCC ID: QISEM820W IC ID: 6369A-EM820W Report No: SYBHZ(R)E045112010EB-2 Confidential Information of Huawei. No Distribution without Written Permission Page5, Total35 Contents 1 Summary.................................................................................................................................................... 6 2 Product Description.................................................................................................................................. 7 2.1 PRODUCTION INFORMATION................................................................................................................... 7 2.2 MODIFICATION INFORMATION.................................................................................................................. 7 3 Test Site Description................................................................................................................................. 8 3.1 TESTING PERIOD................................................................................................................................... 8 3.2 GENERAL SET UP DESCRIPTION............................................................................................................. 8 4 Product Description.................................................................................................................................. 9 4.1 TECHNICAL CHARACTERISTICS............................................................................................................... 9 4.2 EUT IDENTIFICATION LIST.................................................................................................................... 11 5 Main Test Instruments............................................................................................................................. 12 6 Transmitter Measurements..................................................................................................................... 13 6.1 EFFECTIVE RADIATED POWER OF TRANSMITTER (ERP)......................................................................... 13 6.2 CONDUCTED POWER OF TRANSMITTER................................................................................................. 17 6.3 MODULATION CHARACTERISTICS.......................................................................................................... 20 6.4 OCCUPIED BANDWIDTH........................................................................................................................ 22 6.5 BAND EDGES COMPLIANCE.................................................................................................................. 25 6.6 SPURIOUS EMISSION AT ANTENNA TERMINAL........................................................................................ 27 6.7 FREQUENCY STABILITY........................................................................................................................ 30 7 System Measurement Uncertainty......................................................................................................... 34 8 Appendices.............................................................................................................................................. 35 FCC Test Report of EM820W FCC ID: QISEM820W IC ID: 6369A-EM820W Report No: SYBHZ(R)E045112010EB-2 Confidential Information of Huawei.…

Text truncated - open the document above for the full version.

Test Report

FCC Test Report of EM820W FCC ID: QISEM820W Report No: SYBHZ(R)E045112010EB-2 Confidential Information of Huawei. No Distribution without Permission Page1, Total4 Appendix A Modulation Characteristics According to FCC Part 2.1047 & Part22 Subpart H FCC Test Report of EM820W FCC ID: QISEM820W Report No: SYBHZ(R)E045112010EB-2 Confidential Information of Huawei. No Distribution without Permission Page2, Total4 Channel 192(TM1:GPRS/GSM) FCC Test Report of EM820W FCC ID: QISEM820W Report No: SYBHZ(R)E045112010EB-2 Confidential Information of Huawei. No Distribution without Permission Page3, Total4 Channel 192(TM2:EDGE) FCC Test Report of EM820W FCC ID: QISEM820W Report No: SYBHZ(R)E045112010EB-2 Confidential Information of Huawei. No Distribution without Permission Page4, Total4 Channel 4182(TM3: WCDMA) FCC Test Report of EM820W FCC ID: QISEM820W IC ID: 6369A-EM820W Report No: SYBHZ(R)E045112010EB-2 Confidential Information of HUAWEI. No Distribution without Permission Page1, Total10 Appendix B Occupied Bandwidth According to FCC Part 2.1049 & Part 22 Subpart H & RSS-132 FCC Test Report of EM820W FCC ID: QISEM820W IC ID: 6369A-EM820W Report No: SYBHZ(R)E045112010EB-2 Confidential Information of HUAWEI. No Distribution without Permission Page2, Total10 Channel 128(TM1:GPRS/GSM) A * * RBW 3 kHz VBW 10 kHz SWT 115 ms Offset 7.1 dB LVL Ref 35 dBmAtt 35 dB Center 824.2 MHzSpan 1 MHz100 kHz/ *1 AV MAXH -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] 23.26 dBm 824.148717949 MHz OBW246.794871795 kHz T1 Temp 1 [T1 OBW] 10.89 dBm 824.076602564 MHz T2 Temp 2 [T1 OBW] 7.27 dBm 824.323397436 MHz Date: 25.NOV.2010 07:47:45 FCC Test Report of EM820W FCC ID: QISEM820W IC ID: 6369A-EM820W Report No: SYBHZ(R)E045112010EB-2 Confidential Information of HUAWEI. No Distribution without Permission Page3, Total10 Channel 128(TM2:EDGE) A * * RBW 3 kHz VBW 10 kHz SWT 115 ms Offset 7.1 dB LVL Ref 35 dBmAtt 35 dB Center 824.2 MHzSpan 1 MHz100 kHz/ *1 AV MAXH -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] 18.05 dBm 824.220833333 MHz OBW243.589743590 kHz T1 Temp 1 [T1 OBW] 1.88 dBm 824.079807692 MHz T2 Temp 2 [T1 OBW] 1.45 dBm 824.323397436 MHz Date: 25.NOV.2010 08:08:27 FCC Test Report of EM820W FCC ID: QISEM820W IC ID: 6369A-EM820W Report No: SYBHZ(R)E045112010EB-2 Confidential Information of HUAWEI. No Distribution without Permission Page4, Total10 Channel 4132(TM3: WCDMA) A * * RBW 50 kHz VBW 500 kHz SWT 5 ms Offset 7.1 dB LVL Ref 35 dBmAtt 35 dB Center 826.4 MHzSpan 10 MHz1 MHz/ *1 RM MAXH -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] 14.74 dBm 826.992948718 MHz OBW 4.182692308 MHz T1 Temp 1 [T1 OBW] 6.32 dBm 824.316666667 MHz T2 Temp 2 [T1 OBW] 5.56 dBm 828.499358974 MHz Date: 25.NOV.2010 08:13:07 FCC Test Report of EM820W FCC ID: QISEM820W IC ID: 6369A-EM820W Report No: SYBHZ(R)E045112010EB-2 Confidential Information of HUAWEI. No Distribution without Permission Page5, Total10 Channel 192(TM1:GPRS/GSM) A Att 35 dB * * RBW 3 kHz VBW 10 kHz SWT 115 msRef 35 dBm Offset 7.1 dB LVL Center 837 MHzSpan 1 MHz100 kHz/ *1 AV MAXH -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] 23.72 dBm 837.017628205 MHz OBW245.192307692 kHz T1 Temp 1 [T1 OBW] 8.25 dBm 836.878205128 MHz T2 Temp 2 [T1 OBW] 8.62 dBm 837.123397436 MHz Date: 25.NOV.2010 07:47:59 FCC Test Report of EM820W FCC ID: QISEM820W IC ID: 6369A-EM820W Report No: SYBHZ(R)E045112010EB-2 Confidential Information of HUAWEI. No Distribution without Permission Page6, Total10 Channel 192(TM2:EDGE) A Att 35 dB * * RBW 3 kHz VBW 10 kHz SWT 115 msRef 35 dBm Offset 7.1 dB LVL Center 837 MHzSpan 1 MHz100 kHz/ *1 AV MAXH -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] 18.83 dBm 837.038461538 MHz OBW243.589743590 kHz T1 Temp 1 [T1 OBW] 2.34 dBm 836.878205128 MHz T2 Temp 2 [T1 OBW] 5.77 dBm 837.121794872 MHz Date: 25.NOV.2010 08:08:41 FCC Test Report of EM820W FCC ID: QISEM820W IC ID: 6369A-EM820W Report No: SYBHZ(R)E045112010EB-2 Confidential Information of HUAWEI. No Distribution without Permission Page7, Total10 Channel 4182(TM3: WCDMA) A Att 35 dB * * RBW 50 kHz VBW 500 kHz SWT 5 msRef 35 dBm Offset 7.1 dB LVL Center 836.4 MHzSpan 10 MHz1 MHz/ *1 RM MAXH -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] 14.42 dBm 837.489743590 MHz OBW 4.182692308 MHz T1 Temp 1 [T1 OBW] 4.92 dBm 834.332692308 MHz T2 Temp 2 [T1 OBW] 6.19 dBm 838.515384615 MHz Date: 25.NOV.2010 08:13:21 FCC Test Report of EM820W FCC ID: QISEM820W IC ID: 6369A-EM820W Report No: SYBHZ(R)E045112010EB-2 Confidential Information of HUAWEI. No Distribution without Permission Page8, Total10 Channel 251(TM1:GPRS/GSM) A Att 35 dB * * RBW 3 kHz VBW 10 kHz SWT 115 msRef 35 dBm Offset 7.1 dB LVL Center 848.8 MHzSpan 1 MHz100 kHz/ *1 AV MAXH -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] 22.86 dBm 848.796794872 MHz OBW246.794871795 kHz T1 Temp 1 [T1 OBW] 7.94 dBm 848.676602564 MHz T2 Temp 2 [T1 OBW] 5.16 dBm 848.923397436 MHz Date: 25.NOV.2010 07:48:13 FCC Test Report of EM820W FCC ID: QISEM820W IC ID: 6369A-EM820W Report No: SYBHZ(R)E045112010EB-2 Confidential Information of HUAWEI. No Distribution without Permission Page9, Total10 Channel 251(TM2:EDGE) A Att 35 dB * * RBW 3 kHz VBW 10 kHz SWT 115 msRef 35 dBm Offset 7.1 dB LVL Center 848.8 MHzSpan 1 MHz100 kHz/ *1 AV MAXH -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] 18.39 dBm 848.796794872 MHz OBW246.794871795 kHz T1 Temp 1 [T1 OBW] 0.19 dBm 848.675000000 MHz T2 Temp 2 [T1 OBW] 4.89 dBm 848.921794872 MHz Date: 25.NOV.2010 08:08:54 FCC Test Report of EM820W FCC ID: QISEM820W IC ID: 6369A-EM820W Report No: SYBHZ(R)E045112010EB-2 Confidential Information of HUAWEI. No Distribution without Permission Page1…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jason Hu(Technology Engineer)
[email protected](86) 10-64391099Fax: (86) 10-64399872

Test Firm

SIEMIC (Nanjing-China) LaboratoriesLeslie Bai
[email protected]86-25-86730128Fax: 86-25-86730127

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
422H826.4 MHz - 846.6 MHz270.00 mW4M20F9W0.05 ppm
Confidentiality
Long Term
Grant Notes
Power listed is ERP for part 22 and EIRP for part 24. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations This device is to be used only for mobile and fixed application. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

Other Applications from Beijing InHand Networks Technology Co,. Ltd.

Industrial Cellular Router - FCC ID ZAZIR6X5WAP - Beijing InHand Networks Technology Co,. Ltd.
ZAZIR6X5WAP

Industrial Cellular Router

Apr 24, 2013

Equipment Class

DTS - Digital Transmission System
Industrial Cellular Router - FCC ID ZAZIR6X5PAP - Beijing InHand Networks Technology Co,. Ltd.
ZAZIR6X5PAP

Industrial Cellular Router

Apr 23, 2013

Equipment Class

PCB - PCS Licensed Transmitter
Industrial Cellular Router - FCC ID ZAZR7X1GS - Beijing InHand Networks Technology Co,. Ltd.
ZAZR7X1GS

Industrial Cellular Router

Dec 07, 2011

Equipment Class

PCB - PCS Licensed Transmitter