FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hong Kong China Electric Manufacture Co., Ltd/
  3. ZJF-HH002

ZJF-HH002HH002

Hong Kong China Electric Manufacture Co., Ltd
HH002 - FCC ID ZJF-HH002 - Hong Kong China Electric Manufacture Co., Ltd
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jun 19, 2013
Application Purpose
Original Equipment
Date of Application
May 27, 2013
Equipment Note
HH002
Frequency Range
315.00000000 - 315.00000000
Company
Hong Kong China Electric Manufacture Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

6 SPEEDS UP & DOWN LIGHT DC MOTOR CONTROL USER MANUAL Caution: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.

Cover Letter(s)

4$0DQDJHU

Cover Letter(s)

4$0DQDJHU

External Photos

FCC ID: ZJF-HH002 Page 1 of 2 External Picture FCC ID: ZJF-HH002 Page 2 of 2

ID Label/Location Info

FCC ID:ZJF-HH002 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The label will be not removalbe.

Internal Photos

FCC ID: ZJF-HH002 Page 1 of 2 Internal Picture FCC ID: ZJF-HH002 Page 2 of 2

Test Report

FCC ID: ZJF-HH002 Page 1 of 17 EMC TEST REPORT No. 130200692SHA-001 Applicant : HONG KONG CHINA ELECTRIC APPLIANCE MANUFACTURE CO.,LTD. 12/F., Mongkok Harbour Centre 638 Shanghai Street, Mongkok, Kowloon, Hongkong Manufacturer : HONG KONG CHINA ELECTRIC APPLIANCE MANUFACTURE CO.,LTD. 12/F., Mongkok Harbour Centre 638 Shanghai Street, Mongkok, Kowloon, Hongkong Equipment : Remote controller Type/Model : HH002 SUMMARY The equipment complies with the requirements according to the following standard(s): 47CFR Part 15 (2011): Radio Frequency Devices ANSI C63.4 (2003): American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz Date of issue: May 23, 2013 Prepared by: Reviewed by: Endman Zhao (Project Engineer) Daniel Zhao (Reviewer) FCC ID: ZJF-HH002 Page 2 of 17 Description of Test Facility Name: Intertek Testing Services Limited Shanghai Address: Building No.86, 1198 Qinzhou Road(North), Shanghai 200233, P.R. China FCC Registration Number: 236597 IC Assigned Code: 2042B-1 Name of contact: Steve Li Tel: +86 21 64956565 ext. 214 Fax: +86 21 54262335 ext. 214 FCC ID: ZJF-HH002 Page 3 of 17 Content SUMMARY.......................................................................................................................................................... 1 DESCRIPTION OF TEST FACILITY......................................................................................................................... 2 1. GENERAL INFORMATION............................................................................................................................ 4 1.1 Applicant Information..................................................................................................... 4 1.2 Identification of the EUT ................................................................................................ 4 1.3 Technical specification ................................................................................................... 5 1.4 Mode of operation during the test / Test peripherals used.............................................. 5 2. TEST SPECIFICATION.................................................................................................................................. 6 2.1 Instrument list ................................................................................................................. 6 2.2 Test Standard .................................................................................................................. 6 3. FUNDAMENTAL & SPURIOUS EMISSION & RESTRICT BAND RADIATED EMISSION................................... 8 3.1 Test limit ......................................................................................................................... 8 3.2 Test Configuration .......................................................................................................... 9 3.3 Test procedure and test setup .......................................................................................... 9 3.4 Test protocol ................................................................................................................. 10 4. DEACTIVATING TIME................................................................................................................................ 11 4.1 Test limit ....................................................................................................................... 11 4.2 Test Configuration ........................................................................................................ 12 4.3 Test procedure and test setup ........................................................................................ 12 4.4 Test protocol ................................................................................................................. 12 5. POWER LINE CONDUCTED EMISSION........................................................................................................ 13 5.1 Limit.............................................................................................................................. 13 5.2 Test configuration ......................................................................................................... 13 5.3 Test procedure and test set up ....................................................................................... 14 5.4 Test protocol ................................................................................................................. 15 6. EMISSION BANDWIDTH............................................................................................................................. 16 6.1 Test limit ....................................................................................................................... 16 6.2 Test Configuration ........................................................................................................ 16 6.3 Test procedure and test setup ........................................................................................ 16 6.4 Test protocol ................................................................................................................. 17 FCC ID: ZJF-HH002 Page 4 of 17 1. General Information 1.1 Applicant Information Applicant: HONG KONG CHINA ELECTRIC APPLIANCE MANUFACTURE CO.,LTD. 12/F., Mongkok Harbour Centre 638 Shanghai Street, Mongkok, Kowloon, Hongkong Manufacturer: HONG KONG CHINA ELECTRIC APPLIANCE MANUFACTURE CO.,LTD. 12/F., Mongkok Harbour Centre 638 Shanghai Street, Mongkok, Kowloon, Hongkong Sample received date: April 27, 2013 Sample Identification No : 0130427-68-001 Date of test : April 27~ May 2, 2013 1.2 Identification of the EUT Equipment: Remote controller Type/model: HH002 FCC ID: ZJF-HH002 FCC ID: ZJF-HH002 Page 5 of 17 1.3 Technical specification Operation Frequency Band: 315MHz Modulation: ASK Antenna Designation: Integral ante…

Text truncated - open the document above for the full version.

Test Report

FCC ID: ZJF-HH002 Page 1 of 7 Test Data FCC ID: ZJF-HH002 Page 2 of 7 1. Fundamental & Spurious Emission & Restrict band radiated emission Horizontal 30-1000MHz 0 10 20 30 40 50 60 70 80 Level [dB礦/m] 30M50M70M100M200M300M500M700M1G Frequency [Hz] x xx x x x x x x x x MES EZ0423-H1_red MES EZ0423-H1_pre Frequency Level Transd Limit Margin MHz dBμ V/m dB dBμ V/m dB 30.000000 23.40 21.0 40.0 16.6 43.607214 16.00 13.7 40.0 24.0 74.709419 16.00 9.3 40.0 24.0 117.474950 19.50 15.4 43.5 24.0 146.633267 19.60 14.4 43.5 23.9 179.679359 17.40 12.3 43.5 26.1 315.751503 74.40 15.8 46.0 -28.4 471.262525 24.90 19.6 46.0 21.1 630.661323 52.50 21.6 46.0 -6.5 945.571142 49.40 24.5 46.0 -3.4 FCC ID: ZJF-HH002 Page 3 of 7 1000-3000MHz 0 10 20 30 40 50 60 70 80 Level [dB 礦/m] 1G1.5G2G2.5G3G Frequency [Hz] x x x MES EZ0423-HH2_red MES EZ0423-HH2_pre Frequency Level Transd MHz dBμ V/m dB 1260.521042 44.06 -8.6 2414.829659 42.60 -7.6 FCC ID: ZJF-HH002 Page 4 of 7 Vertical 30-1000MHz 0 10 20 30 40 50 60 70 80 Level [dB 礦/m] 30M50M70M100M200M300M500M700M1G Frequency [Hz] x x x x x x x x x x x MES EZ0423-V1_red MES EZ0423-V1_pre Frequency Level Transd Limit Margin MHz dBμ V/m dB dBμ V/m dB 30.000000 23.30 21.0 40.0 16.7 43.607214 16.40 13.7 40.0 23.6 74.709419 15.80 9.3 40.0 24.2 119.418838 19.40 15.5 43.5 24.1 134.969940 19.80 15.0 43.5 23.7 195.230461 17.80 12.7 43.5 25.7 315.751503 62.70 15.8 46.0 -16.7 486.813627 24.00 19.8 46.0 22.0 630.661323 51.60 21.6 46.0 -5.6 945.571142 33.30 24.5 46.0 12.7 FCC ID: ZJF-HH002 Page 5 of 7 1000-3000MHz 0 10 20 30 40 50 60 70 80 Level [dB 礦/m] 1G1.5G2G2.5G3G Frequency [Hz] x x x MES EZ0423-HV1_red MES EZ0423-HV1_pre Frequency Level Transd Limit Margin MHz dBμ V/m dB dBμ V/m dB 1260.521042 43.77 -8.6 2342.685371 40.82 -7.6 FCC ID: ZJF-HH002 Page 6 of 7 2. Deactivating time FCC ID: ZJF-HH002 Page 7 of 7 3. Emission bandwidth Emission bandwidth = 25.375 + 38.625 = 64 kHz

Test Setup Photos

Page 1 of 5 Test Setup Page 2 of 5 1. Radiated Emission 30MHz-1000MHz, X axis 30MHz-1000MHz, Y axis Page 3 of 5 30MHz-1000MHz, Z axis Page 4 of 5 Higher than 1GHz, X axis Higher than 1GHz, Y axis Page 5 of 5 Higher than 1GHz, Z axis

Contact Information

Applicant

For Cheung(Asst. Quality Manager)
[email protected]852-23909368Fax: 852-23910880

Technical Contact

Intertek Testing Services Limited ShanghaiEndman Zhao
[email protected]86-21-61278444

Building No.86, 1198 Qinzhou Road(North) · Shanghai · China

Test Firm

Intertek Testing Services Limited ShanghaiJonny Jing
[email protected]86-21-61278271Fax: 86-21-54262353

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231315 MHz - 315 MHz-
Confidentiality
Long Term

Other Applications from Hong Kong China Electric Manufacture Co., Ltd

Fan Remoter - FCC ID ZJF-RT01A - Hong Kong China Electric Manufacture Co., Ltd
ZJF-RT01A

Fan Remoter

Nov 02, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
HHDCL002 - FCC ID ZJF-HHDCL002 - Hong Kong China Electric Manufacture Co., Ltd
ZJF-HHDCL002

HHDCL002

Jul 21, 2013

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
Ceiling suspended fan - FCC ID ZJF-DCM70-5B-2L - Hong Kong China Electric Manufacture Co., Ltd
ZJF-DCM70-5B-2L

Ceiling suspended fan

Aug 17, 2011

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
Ceiling suspended fan - FCC ID ZJF-HH-YK-A008 - Hong Kong China Electric Manufacture Co., Ltd
ZJF-HH-YK-A008

Ceiling suspended fan

Aug 03, 2011

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter