ZP912696450999Robot Vacuum Cleaner

Alfred Kaercher GmbH & Co. KG

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 07, 2024
Application Purpose
Original Equipment
Date of Application
May 05, 2024
Equipment Note
Robot Vacuum Cleaner
Frequency Range
2412.00000000 - 2462.00000000
Company
Alfred Kaercher GmbH & Co. KG
Country
Germany

Documents & Files

Select a file to view

Attestation Statements

↗

Cover Letter(s)

ID Label/Location Info

RF Exposure Info

↗

Test Report

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

RF Exposure Info

1 Safety Human Exposure 1.1 Radio Frequency Exposure Compliance 1.1.1 Electromagnetic Fields RESULT: Pass Report Number : CN24YGJN 003 Test Specification Test item : Robot Vacuum Cleaner Identification / Type No. : RCV 5 FCC ID : ZP912696450999 IC: 9752A-12696450999 Test standard : CFR47 FCC Part 2: Section 2.1091 CFR47 FCC Part 1: Section 1.1310 FCC KDB Publication 447498 D01 v06 FCC KDB Publication 865664 D02 v01r02 RSS-102 Issue 5 February 2021 1.1.1.1 RF Exposure Compliance Requirement for FCC FCC requirement: Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess limit for maximum permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a mobile device whereby a distance of 20cm normally can be maintained between the user and the device. Max 2.23 dBi for 2.4GHz Wi-Fi ➢ Radio Frequency Exposure Limit Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm²) 300-1,500 -- -- f/1500 1,500-100,000 -- -- 1.0 ➢ Radio Frequency Exposure Calculation Formula a) RF Exposure Evaluation standalone operations (worse case) Mode *Measured RF Output Power (dBm) EIRP (dBm) Distance (cm) Power Density (mW/cm²) FCC Limit (mW/cm²) 2.4G Wi-Fi 20.73 22.96 20 0.039 1.0 *Note:2.4GHz Band RF Output Power: Refer to CN24YGJN 002 ➢ Conclusion Therefore, the maximum calculations result of above are meet the requirement of Radio Frequency Exposure (MPE) limit. 1.1.1.2 RF Exposure Compliance Requirement for IC The EUT shall comply with the requirement of RSS-102 section 2.5.2. Exemption from Routine Evaluation Limits – RF Exposure Evaluation RF exposure evaluation is required if the separation distance between the user and/or bystander and the device’s radiating element is greater than 20 cm, except when the device operates as follows: at or above 300 MHz and below 6 GHz and the source-based, time-averaged maximum e.i.r.p. of the device is equal to or less than 1.31 x 10 -2 ƒ 0.6834 W (adjusted for tune-up tolerance), where ƒ is in MHz; • RF exposure evaluation exempted power for 2.4GHz: 2.67 W The nominal maximum conducted output power specified: Max 2.23 dBi for 2.4GHz Wi-Fi The Max. e.i.r.p. for 2.4GHz Wi-Fi: 22.96 dBm = 0.196 W e.i.r.p. for the 2.4GHz Wi-Fi is less than the RF exposure evaluation exempted power. So RF exposure evaluation is not required. “RF Radiation Exposure Statement Caution: This Transmitter must be installed to provide a separation distance of at least 20 cm from all persons.” geprüft von: tested by: X Signed by: Chris Chen Datum: Date: 2024-03-21 Stellung / Position Department Manager

Contact Information

Applicant

Steffen Reiser(Manager Regulatory Affairs & Certification)
[email protected]+49(7195)14Fax: +49(7195)901-1014

Technical Contact

Alfred Kaercher SE & Co. KGSteffen Reiser
[email protected]+49(7195)14

Alfred-Karcher-Str. 28-40, 71364 Winnenden, German · Germany

Test Firm

TUV Rheinland (Shenzhen) Co., Ltd.Gina Yang
[email protected]86 755 8268 1497

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz118.30 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter evaluation procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This device has 20/40MHz bandwidth modes.

Other Applications from Alfred Kaercher GmbH & Co. KG

Control panel with RFID reader - FCC ID ZP966831810999 - Alfred Kaercher GmbH & Co. KG
ZP966831810999

Control panel with RFID reader

Jun 11, 2013

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Platine Bedienfeld B80 - FCC ID ZP940353910999 - Alfred Kaercher GmbH & Co. KG
ZP940353910999

Platine Bedienfeld B80

Aug 27, 2012

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
RF-ID Modul - FCC ID ZP940360540999 - Alfred Kaercher GmbH & Co. KG
ZP940360540999

RF-ID Modul

Mar 22, 2012

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter