
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RFID Reader KCPU 1 PD CDR-E 2013-01-10 1/2 Installer Instructions for RFID-Module KCPU 1 The module KCPU 1 consists of a control panel prepared for installation in the control panel receptacle of a Kärcher power sweeper of the KM105/110 R & family series. It contains a RFID reader for reading authorization codes from tags embedded in user keys and for writing authorization code changes. The user keys can be inserted into a key receptacle in the control panel. The user keys and the key receptacle use a design which was specifically developed for Kärcher cleaning appliances. Changes or modifications made to the equipment not explicitly approved by Alfred Kärcher GmbH & Co. KG may void the FCC / IC authorization to operate this equipment. The use of the transceiver in mobile or fixed devices other than the Kärcher power sweeping appliance KM105 & family is authorized taking into account the conditions listed below: • The OEM integrator has to ensure that the end user manual may not contain any information about the way to install or remove the module from the final product. • Depending on final host configuration additional authorization requirements for the non-transmitter functions on the transmitter module may be required (i.e., verification, or declaration of conformity). The OEM integrator is responsible for ensuring that after the module is installed and operational in the host, it continues to be compliant with the Part 15B unintentional radiator requirements. • The information on label and user manual for the module is required to be incorporated in the user manual of the final system. See 47 CFR15 requirements for more details (e.g. 15.19 / 15.21 / 15.101 / 15.105 / RSS-GEN / ICES) • An additional label with the text ‘Contains FCC ID: ZP966831810999’ and ‘Contains IC: 9752A-66831810999' shall be applied and visible from the outside of the end product. • The module must be installed and used in strict accordance with the manufacturer’s instructions as described in the user documentation that comes with the product. • The antenna of the module may not be removed, replaced nor modified. The antenna must not be co-located or operating in conjunction with any other antenna or transmitter. No additional antenna must be used. • The module must comply with RF exposure requirements according to CFR Part 15, RSS-210 Issue 8 Annex 2.6 and RSS-102 when it is installed in the host device. • The radio elements of the module RFID KM105 do not have the radio frequency circuitry shielded. For this reason the shielding must be provided by the module host. • The module has a microcontroller for buffered data input. The module is connected to the host by RS485-bus. • The module contains a voltage regulator for power supply. The input voltage of the module supplied by the host must be in the range from 13 V to 15 V. RFID Reader KCPU 1 PD CDR-E 2013-01-10 2/2 NOTICE: This device complies with Part 15 of the FCC Rules and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le onctionnement. NOTICE: Changes or modifications made to this equipment not expressly approved by Alfred Kärcher GmbH & Co. KG may void the FCC authorization to operate this equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.
Test report no.: 1-5610/12-01-03_AnnexA 2013-05-28 Page 1 of 5 Annex A This test report annex is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report annex authorised: Marco Bertolino Testing Manager Test report no.: 1-5610/12-01-03_AnnexA 2013-05-28 Page 2 of 5 External photos of the EUT Photo documentation: Photo 1: Photo 2: Test report no.: 1-5610/12-01-03_AnnexA 2013-05-28 Page 3 of 5 Photo 3: Photo 4: Test report no.: 1-5610/12-01-03_AnnexA 2013-05-28 Page 4 of 5 Photo 5: Test report no.: 1-5610/12-01-03_AnnexA 2013-05-28 Page 5 of 5 Document history Version Applied changes Date of release 1.0 Initial release 2013-05-28
Test report no.: 1-5610/12-01-03_AnnexB 2013-05-28 Page 1 of 4 Annex B This test report annex is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report annex authorised: Marco Bertolino Testing Manager Test report no.: 1-5610/12-01-03_AnnexB 2013-05-28 Page 2 of 4 Internal photos of the EUT Photo documentation: Photo 1: Photo 2: Test report no.: 1-5610/12-01-03_AnnexB 2013-05-28 Page 3 of 4 Photo 3: Photo 4: Test report no.: 1-5610/12-01-03_AnnexB 2013-05-28 Page 4 of 4 Document history Version Applied changes Date of release 1.0 Initial release 2013-05-28
2013-05-28 Page 1 of 23 TEST REPORT Test report no.: 1-5610/12-01-03-A Testing laboratory Applicant CETECOM ICT Services GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: http://www.cetecom.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2005) by the Deutsche Akkreditierungsstelle GmbH (DAkkS) The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12076-01-01 Area of Testing: Radio/Satellite Communications Alfred Kärcher GmbH & Co. Alfred-Kärcher-Str. 28-40 71364 Winnenden / GERMANY Phone: +49 7195 14-0 Fax: +49 7195 14-3458 Contact: Dieter Plachke e-mail: [email protected] Phone: +49 7195 14-2374 Manufacturer Technic-Center Frankenberg/Sa Engineering GmbH Lerchenstraße 25 09669 Frankenberg/Sa / GERMANY Test standard/s 47 CFR Part 15 Title 47 of the Code of Federal Regulations; Chapter I Part 15 - Radio frequency devices RSS - 210 Issue 8 Spectrum Management and Telecommunications - Radio Standards Specification Low-power Licence-exempt Radiocommunication Devices (All Frequency Bands): Category I Equipment For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: Master CPU with integrated RFID unit Model name: KCPU 1 FCC ID: ZP966831810999 IC: 9752A-66831810999 Frequency: 13.56 MHz Technology tested: RFID Antenna: Integrated loop antenna Power Supply: 14 V DC by external power supply Temperature Range: -20°C to +50°C This test report is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorised: Test performed: Christoph Schneider Marco Bertolino Expert Testing Manager Test report no.: 1-5610/12-01-03-A 2013-05-28 Page 2 of 23 1 Table of contents 1 Table of contents ............................................................................................................................................ 2 2 General information ....................................................................................................................................... 3 2.1 Notes and disclaimer .......................................................................................................................... 3 2.2 Application details ............................................................................................................................... 3 3 Test standard/s ............................................................................................................................................... 3 4 Test environment ............................................................................................................................................ 4 5 Test item .......................................................................................................................................................... 4 5.1 Additional comments .......................................................................................................................... 4 6 Test laboratories sub-contracted ................................................................................................................. 4 7 Summary of measurement results ............................................................................................................... 5 8 Description of the test setup ......................................................................................................................... 6 8.1 Radiated measurements ..................................................................................................................... 6 8.2 AC conducted ...................................................................................................................................... 7 8.3 Conducted measurements ................................................................................................................. 8 9 RSP100 test report cover sheet / performance test data ........................................................................... 9 10 Measurement results ............................................................................................................................ 10 10.1 Timing of the transmitter ............................................................................................................... 10 10.2 Field strength of the fundamental ................................................................................................ 11 10.3 99 % emission bandwidth ............................................................................................................. 12 10.4 Field strength of the harmonics and spurious ........................................................................... 13 10.5 Frequency tolerance ...................................................................................................................... 17 10.6 AC line conducted ......................................................................................................................... 18 11 Test equipment and ancillaries used for tests ................................................................................... 20 12 Observations ......................................................................................................................................... 21 Annex A Document history .......................................................................................................................... 22 Annex B Further information ........................................................................................................................ 22 Annex C Accreditation Certificate ...........................…
Text truncated - open the document above for the full version.
Test report no.: 1-5610/12-01-03_AnnexC 2013-05-28 Page 1 of 5 Annex C This test report annex is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report annex authorised: Marco Bertolino Testing Manager Test report no.: 1-5610/12-01-03_AnnexC 2013-05-28 Page 2 of 5 Photos of the Test Setup Photo documentation: Photo 1: Photo 2: Test report no.: 1-5610/12-01-03_AnnexC 2013-05-28 Page 3 of 5 Photo 3: Photo 4: Test report no.: 1-5610/12-01-03_AnnexC 2013-05-28 Page 4 of 5 Photo 5: Test report no.: 1-5610/12-01-03_AnnexC 2013-05-28 Page 5 of 5 Document history Version Applied changes Date of release 1.0 Initial release 2013-05-28
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |
Robot Vacuum Cleaner
Equipment Class
DTS - Digital Transmission System
Platine Bedienfeld B80
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RF-ID Modul
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter