Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Signcomplex Limited 401,Mingfeng Bulding, No.2 Xikeng Road, Xinhe Community, Fucheng street, Longhua, Shenzhen, Guangdong, China Attestation Statements Not Covered Entity Applicant & Not Covered Equipment To: Federal Communications Commission Date: Mar. 4, 26 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) & (ii) FCC ID: ZR3-DL107RG Signcomplex Limited (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List, established pursuant to § 1.50002 of reference chapter, as an entity producing “covered” communication equipment. The equipment for which authorization is sought is not “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List that prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely yours, Applicant Signature Printed Name: jing hua liu Title: R&D Manager Address: 401,Mingfeng Bulding, No.2 Xikeng Road, Xinhe Community, Fucheng street, Longhua, Shenzhen, Guangdong, China Tel.: 0750-8389786 Email: [email protected]
Signcomplex Limited 401,Mingfeng Bulding, No.2 Xikeng Road, Xinhe Community, Fucheng street, Longhua, Shenzhen, Guangdong, China 1 | P a g e Attestation Statements To: Federal Communications Commission Date: Mar. 4, 26 7435 Oakland Mills Road, Columbia, MD 21046, USA Subject: Attestation of Compliance with FCC Covered List Software Requirements FCC ID: ZR3-DL107RG Product Name: LED recessed downlight This letter serves as an attestation that the equipment identified above ☐ is / ☒ is not (select one) "covered" software as defined under the Federal Communications Commission (FCC) Covered List requirements, as outlined in FCC 22-84 and KDB 986446. Specifically, the undersigned certifies that the equipment for which authorization is sought: 1. Does not contain cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors, assignees, parents, subsidiaries, affiliates, or any entity that has rebranded or relabeled software produced by the aforementioned entities. 2. Does not have the capability to store, run, or deliver any software identified on the FCC Covered List, including but not limited to cybersecurity and anti-virus software. To support this attestation, the appendix evaluation documentation has been prepared and is included in the certification filing. This attestation is based on a thorough evaluation of the device's design, functionality, and software environment. The undersigned affirms that the information provided is accurate and complete to the best of their knowledge. Sincerely yours, Applicant Signature Printed Name: jing hua liu Title: R&D Manager Address: 401,Mingfeng Bulding, No.2 Xikeng Road, Xinhe Community, Fucheng street, Longhua, Shenzhen, Guangdong, China Tel.: 0750-8389786 Email: [email protected] Signcomplex Limited 401,Mingfeng Bulding, No.2 Xikeng Road, Xinhe Community, Fucheng street, Longhua, Shenzhen, Guangdong, China 2 | P a g e Evaluation regarding to the Covered List Software: Compliance Methodology Evaluation Process Results Device is Inherent compliance ☒ The Chipset(s) used is limited to run the Cybersecurity or anti-virus software. Compliance ☒ The Memory used is limited to run the Cybersecurity or anti-virus software. Compliance ☒ There is storage capacity limitation for store or install the Cybersecurity or anti-virus software. Compliance ☒ Operating system used is limited to run, install or deliver the Cybersecurity or anti-virus software. Compliance Device is not Inherent compliance ☐ Evaluation Based on Software Bill of Materials (SBoM) See attached “SBoM“ Note:The SBoM content is limited to the scope of covered list software (e.g. antivirus and cybersecurity software). ☐ Evaluation Based on Scan for Software on the device ☐ Evaluation Based on Filesystem scan ☐ Evaluation Based on Running software check
CFR 47 §2.911(d)(7)Agent Designation Attestation Date:4-3-2025 FCC ID: ZR3-DL107RG FRN:0021027628 To:Federal Communications Commission 7435OaklandMillsRoad Columbia,MD21046 USA Picus Advisors US LLC("theagent")asrequiredbysection 2.911(d)(7),willalsoserveas the agent for serviceofprocess fortheabovereferencedFCCID. Signcomplex Limited("the applicant") acknowledges that they will maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of anyCommission-related proceeding involving the equipment.The applicant furtheracknowledges theirresponsibility to inform the FCC whenever the agent information changes. USAgentinformation: Contact Person:lvan Wang Company Name:Picus Advisors US LLC Company US Address:5855 SOVEREIGN DRSTE B-1, HOUSTON, TX 77036, USA Telephone: +1(713) 391-4488 FRN: 0034336891 E-mail:[email protected] Signature: Applicant: Contact Person: jing hua liu Company Name: Signcomplex Limited Company Address: 401, Mingfeng Building, No.2, Xikeng Road, Xinhe Community, Fucheng Street, Longhua, Shenzhen, Guangdong, China Email: [email protected] Telephone: 0750-8389786
Signcomplex Limited 401,Mingfeng Bulding, No.2 Xikeng Road, Xinhe Community, Fucheng street, Longhua, Shenzhen, Guangdong, China Date: 2026/3/4 Dear Sir/Madam, We, Signcomplex Limited, Hereby declares the following statement, The "YY": can be 70,80, 90,represent LED Color Rendering Index 70, 80, 90. The "XX"can be two characters denotes commercial code for commercial use. The "ZZ "can be any numbers form 01 to 99 which is for commercial use. Product name: LED recessed downlight FCC ID: ZR3-DL107RG Model no.: DL107RG-8-40W-CCT-R90-0001, DL107RG-8-40W-CCT-RYY-XXZZ, DL107R-8-40W- CCT-RYY-XXZZ, DL107RG-8-40W-5CCT-RYY-XXZZ, DL107R-8-40W-5CCT-RYY-XXZZ, DL107RG-6-30W-CCT-RYY-XXZZ, DL107R-6-30W-CCT-RYY-XXZZ, DL107RG-6-30W-5CCT- RYY-XXZZ, DL107R-6-30W-5CCT-RYY-XXZZ Sincerely, Name/Title: jing hua liu / R&D Manager Company: Signcomplex Limited Address: 401,Mingfeng Bulding, No.2 Xikeng Road, Xinhe Community, Fucheng street, Longhua, Shenzhen, Guangdong, China Phone: 0750-8389786 Fax: 0755-27608651 E-Mail: [email protected]
Signcomplex Limited 401,Mingfeng Bulding, No.2 Xikeng Road, Xinhe Community, Fucheng street, Longhua, Shenzhen, Guangdong, China March 4, 2026 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request for: FCC ID: ZR3-DL107RG Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request permanent confidential treatment of the exhibits accompanying this certification application as outlined below : ⎯ Block Diagram ⎯ Schematics ⎯ Operational Description The above exhibits contain trade secrets and/or proprietary information that are not publicly available and materials that the Applicant has spent considerable efforts in developing. Public disclosure of these may be harmful to the Applicant and give an unfair advantage to competitors on the market. Pursuant to DA 04-1705, the applicant also requests temporary confidential treatment of the exhibits outlined below for a period of 45 days from the date of equipment authorization and prior to marketing in the United States to prevent the premature release of any sensitive information. Applicant is aware of their responsibility to notify DERYCOM in the event information regarding the product or the product is made available to the public before the requested period has expired. ⎯ User Manual ⎯ Internal Photos Sincerely, Title: R&D Manager Address: 401,Mingfeng Bulding, No.2 Xikeng Road, Xinhe Community, Fucheng street, Longhua, Shenzhen, Guangdong, China Tel.: 0750-8389786 Email: [email protected]
Signcomplex Limited 401,Mingfeng Bulding, No.2 Xikeng Road, Xinhe Community, Fucheng street, Longhua, Shenzhen, Guangdong, China March 31, 2026 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization for FCC ID: ZR3-DL107RG I, the undersigned, hereby authorize Attestation of Global Compliance (Shenzhen) Co., Ltd. to act on our behalf in all matters relating to this application for equipment certification. Any act carried out by Attestation of Global Compliance (Shenzhen) Co., Ltd. shall have the same effect as our own and I acknowledge that all responsibility for complying with the terms and conditions of certification, as specified by DERYCOM CERTIFICATION SERVICES, INC., still resides with Signcomplex Limited. We certify that we are not subject to a denial of federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862, and that no party to the application, as defined in 47 CFR §1.2002(b), is subject to a denial of federal benefits that includes FCC benefits pursuant to that section. Sincerely, jing hua liu R&D Manager Tel: 0750-8389786 Fax: 0755-27608651 Email: [email protected]
ReportNo.:AGC10211260314AP02 Page 1 of 3 Figure1 Figure2 ReportNo.:AGC10211260314AP02 Page 2 of 3 Figure3 Figure4 ReportNo.:AGC10211260314AP02 Page 3 of 3 Figure5 Figure6 ****************************************EndofReport*************************************
Label Location FCC ID: ZR3-DL107RG
Page1of10 RFExposureReport ReportNo.:AGC10211260314FH01 FCCID: ZR3-DL107RG APPLICATIONPURPOSE: OriginalEquipment PRODUCTDESIGNATION: LEDrecesseddownlight BRANDNAME: SIGNCOMPLEX MODELNAME: DL107RG-8-40W-CCT-R90-0001, DL107RG-8-40W-CCT-RYY-XXZZ, DL107R-8-40W-CCT-RYY-XXZZ, DL107RG-8-40W-5CCT-RYY-XXZZ, DL107R-8-40W-5CCT-RYY-XXZZ, DL107RG-6-30W-CCT-RYY-XXZZ, DL107R-6-30W-CCT-RYY-XXZZ, DL107RG-6-30W-5CCT-RYY-XXZZ, DL107R-6-30W-5CCT-RYY-XXZZ APPLICANT: SigncomplexLimited DATEOFISSUE: Mar.22,2026 STANDARD(S): FCCKDB447498D04InterimGeneralRFExposure Guidancev01 REPORTVERSION:V1.0 AttestationofGlobalCompliance(Shenzhen)Co.,Ltd ReportNo.:AGC10211260314FH01 Page 2 of 10 ReportReviseRecord ReportVersionReviseTimeIssuedDateValidVersionNotes V1.0/Mar.22,2026ValidInitialRelease ReportNo.:AGC10211260314FH01 Page 3 of 10 TableofContents 1.GeneralInformation..........................................................................................................................................4 2.ProductInformation..........................................................................................................................................5 2.1ProductTechnicalDescription....................................................................................................................5 3.TestEnvironment..............................................................................................................................................6 3.1AddressOfTheTestLaboratory.................................................................................................................6 3.2TestFacility..................................................................................................................................................6 3.3EnvironmentalConditions...........................................................................................................................7 4.EvaluationMethodandLimit...........................................................................................................................8 5.MeasurementResults.......................................................................................................................................9 ReportNo.:AGC10211260314FH01 Page 4 of 10 1.GeneralInformation ApplicantSigncomplexLimited Address 401,MingfengBuilding,No.2,XikengRoad,XinheCommunity,FuchengStreet, Longhua,Shenzhen,Guangdong,China Manufacturer SIGNCOMPLEXLIMITED Address No.70HexiangWestRoad,HeshanIndustrialParkHeshan,Guangdong,China ProductDesignation LEDrecesseddownlight BrandName SIGNCOMPLEX TestModel DL107RG-8-40W-CCT-R90-0001 SeriesModel(s) DL107RG-8-40W-CCT-RYY-XXZZ,DL107R-8-40W-CCT-RYY-XXZZ, DL107RG-8-40W-5CCT-RYY-XXZZ,DL107R-8-40W-5CCT-RYY-XXZZ, DL107RG-6-30W-CCT-RYY-XXZZ,DL107R-6-30W-CCT-RYY-XXZZ, DL107RG-6-30W-5CCT-RYY-XXZZ,DL107R-6-30W-5CCT-RYY-XXZZ DifferenceDescription 1.The"YY":canbe70,80,90,representLEDColorRenderingIndex70,80,90. 2.The"XX"canbetwocharactersdenotescommercialcodeforcommercialuse. 3.The"ZZ"canbeanynumbersform01to99whichisforcommercialuse. Dateofreceiptoftestitem Mar.09,2026 DateofTest Mar.09,2026~Mar.22,2026 DeviationfromStandard Noanydeviationfromthetestmethod ConditionofTestSample Normal TestResult Pass TestReportFormNo AGCER-FCC-RFExposure-V1 Note:Thetestresultsofthisreportrelateonlytothetestedsampleidentifiedinthisreport. PreparedBy CoolCheng (ProjectEngineer) Mar.22,2026 ReviewedBy BiboZhang (Reviewer) Mar.22,2026 ApprovedBy AngelaLi (AuthorizedOfficer) Mar.22,2026 ReportNo.:AGC10211260314FH01 Page 5 of 10 2.ProductInformation 2.1ProductTechnicalDescription FrequencyBand(Operating)Bluetooth:2.402GHz~2.480GHz HardwareVersionV1.0 SoftwareVersionV1.0 ModulationTypeBLEGFSK1MbpsGFSK2Mbps DeviceCategory Portable(<20cmseparation) Mobile(>20cmseparation) Others: AntennaDiversity Singleantenna Multipleantennas Txdiversity Rxdiversity Tx/Rxdiversity MinimumAssessmentDistance200mm EvaluationApplied MPEEvaluation SAREvaluation ReportNo.:AGC10211260314FH01 Page 6 of 10 3.TestEnvironment 3.1AddressOfTheTestLaboratory Laboratory:AttestationofGlobalCompliance(Shenzhen)Co.,Ltd. Address:1-2/F,Building19,JunfengIndustrialPark,ChongqingRoad,HepingCommunity,FuhaiStreet, Bao'anDistrict,Shenzhen,Guangdong,China 3.2TestFacility Thetestfacilityisrecognized,certified,oraccreditedbythefollowingorganizations: CNAS-LabCode:L5488 AttestationofGlobalCompliance(Shenzhen)Co.,Ltd.hasbeenassessedandprovedtofollowCNAS-CL01 AccreditationCriteriaforTestingandCalibrationLaboratories(identicaltoISO/IEC17025:2017General RequirementsfortheCompetenceofTestingandCalibrationLaboratories.) A2LA-LabCert.No.:5054.02 AttestationofGlobalCompliance(Shenzhen)Co.,Ltd.EMCLaboratoryhasbeenaccreditedbyA2LAfor technicalcompetenceinthefieldofelectricaltesting,andprovedtofollowISO/IEC17025:2017General RequirementsfortheCompetenceofTestingandCalibrationLaboratoriesandanyadditionalprogram requirementsintheidentifiedfieldoftesting. FCC-RegistrationNo.:975832 AttestationofGlobalCompliance(Shenzhen)Co.,Ltd.EMCLaboratoryhasbeenregisteredandfully describedinareportfiledwiththeFCC(FederalCommunicationsCommission).Theacceptanceletterfromthe FCCismaintainedinourfileswithRegistration975832. IC-RegistrationNo.:24842(CABidentifier:CN0063) AttestationofGlobalCompliance(Shenzhen)Co.,Ltd.EMCLaboratoryhasbeenregisteredandfully describedinareportfiledwiththeCertificationandEngineeringBureauofIndustryCanada.Theacceptance letterfromtheICismaintainedinourfileswithRegistration24842. ReportNo.:AGC10211260314FH01 Page 7 of 10 3.3EnvironmentalConditions NormalConditions Temperaturerange(°C) 15-35 Relativehumidityrange 20%-75% Pressurerange(kPa) 86-106 ReportNo.:AGC10211260314FH01 Page 8 of 10 4.EvaluationMethodandLimit AccordingtosectionB.4of447498D04InterimGeneralRFExposureGuidancev01 SAR-basedthresholdsarederivedbasedonfrequency,power,andseparationdistanceoftheRFsource. Theformuladefinesthethresholdsingeneralforeitheravailablemaximumtime-averagedpoweror maximumtime-averagedERP,whiche…
Text truncated - open the document above for the full version.
天线规格书 Antenna Specific 制造商(Manufacturer) : Shenzhen Ouchao Technology Co., Ltd 地址(address) : 303, Building 34, Longzhu Garden, Xixiang Street, Bao’an District, Shenzhen, China. 产品种类:Internal Antenna Product Type: Internal Antenna 产品技术指标(Technical parameter) Electronic Parameter 频率范围(Frequency Range) 2400~2500MHz 输入阻抗(input impedance) 50Ω 驻波比(VSWR) ≤2 增益(Gain) Max 0.0dBi Physical Parameter 材料(Material) PCB/Cu 工作温度(operation temperature) -30°C~+80°C 储存温度(store temperature) -30°C~+80°C 产品规格图(Antenna Specification chart) Test Result: Frequency Gain.dBi Frequency Efficiency 2400MHz -0.31 2400MHz 28% 2450MHz 0.0 2450MHz 31% 2500MHz -0.71 2500MHz 36% Direction: Smith Chart: VSWR:
Page 1 of 62 FCCTestReport ReportNo.:AGC10211260314FR02 FCCID: ZR3-DL107RG APPLICATIONPURPOSE: OriginalEquipment PRODUCTDESIGNATION:LEDrecesseddownlight BRANDNAME:SIGNCOMPLEX MODELNAME: DL107RG-8-40W-CCT-R90-0001, DL107RG-8-40W-CCT-RYY-XXZZ, DL107R-8-40W-CCT-RYY-XXZZ, DL107RG-8-40W-5CCT-RYY-XXZZ, DL107R-8-40W-5CCT-RYY-XXZZ, DL107RG-6-30W-CCT-RYY-XXZZ, DL107R-6-30W-CCT-RYY-XXZZ, DL107RG-6-30W-5CCT-RYY-XXZZ, DL107R-6-30W-5CCT-RYY-XXZZ APPLICANT:SigncomplexLimited DATEOFISSUE:Mar.22,2026 STANDARD(S):FCCPart15SubpartC§15.247 REPORTVERSION:V1.0 AttestationOfGlobalCompliance(Shenzhen)Co.,Ltd ReportNo.:AGC10211260314FR02 Page2of62 ReportReviseRecord ReportVersionReviseTimeIssuedDateValidVersionNotes V1.0/Mar.22,2026ValidInitialRelease ReportNo.:AGC10211260314FR02 Page3of62 TableofContents 1.GeneralInformation..........................................................................................................................................5 2.ProductInformation..........................................................................................................................................6 2.1ProductTechnicalDescription....................................................................................................................6 2.2TestFrequencyList.....................................................................................................................................6 2.3RelatedSubmittal(S)/Grant(S).................................................................................................................7 2.4TestMethodology........................................................................................................................................7 2.5SpecialAccessories....................................................................................................................................7 2.6EquipmentModifications.............................................................................................................................7 2.7AntennaRequirement.................................................................................................................................7 3.TestEnvironment..............................................................................................................................................8 3.1AddressoftheTestLaboratory...................................................................................................................8 3.2TestFacility..................................................................................................................................................8 3.3EnvironmentalConditions...........................................................................................................................9 3.4MeasurementUncertainty...........................................................................................................................9 3.5ListofEquipmentUse...............................................................................................................................10 4.SystemTestConfiguration.............................................................................................................................12 4.1EUTConfiguration....................................................................................................................................12 4.2EUTExercise............................................................................................................................................12 4.3ConfigurationofTestedSystem................................................................................................................12 4.4EquipmentUsedInTestedSystem..........................................................................................................12 4.5SummaryofTestResults..........................................................................................................................13 5.DescriptionofTestModes.............................................................................................................................14 6.DutyCycleMeasurement...............................................................................................................................15 7.RFOutputPowerMeasurement....................................................................................................................19 7.1ProvisionsApplicable................................................................................................................................19 7.2MeasurementProcedure..........................................................................................................................19 7.3MeasurementSetup(BlockDiagramofConfiguration)...........................................................................19 7.4MeasurementResult.................................................................................................................................20 8.6dBBandwidthMeasurement.......................................................................................................................24 8.1ProvisionsApplicable................................................................................................................................24 8.2MeasurementProcedure..........................................................................................................................24 8.3MeasurementSetup(BlockDiagramofConfiguration)...........................................................................24 8.4MeasurementResults...............................................................................................................................25 9.PowerSpectralDensityMeasurement.........................................................................................................31 9.1ProvisionsApplicable......................................................................................…
Text truncated - open the document above for the full version.
ReportNo.:AGC10211260314FR02 Page37of62 BLE_1M-Ant1-2402-1000~26500-PASS BLE_1M-Ant1-2440-0~Reference-PASS ReportNo.:AGC10211260314FR02 Page38of62 BLE_1M-Ant1-2440-30~1000-PASS BLE_1M-Ant1-2440-1000~26500-PASS ReportNo.:AGC10211260314FR02 Page39of62 BLE_1M-Ant1-2480-0~Reference-PASS BLE_1M-Ant1-2480-30~1000-PASS ReportNo.:AGC10211260314FR02 Page40of62 BLE_1M-Ant1-2480-1000~26500-PASS BLE_2M-Ant1-2402-0~Reference-PASS ReportNo.:AGC10211260314FR02 Page41of62 BLE_2M-Ant1-2402-30~1000-PASS BLE_2M-Ant1-2402-1000~26500-PASS ReportNo.:AGC10211260314FR02 Page42of62 BLE_2M-Ant1-2440-0~Reference-PASS BLE_2M-Ant1-2440-30~1000-PASS ReportNo.:AGC10211260314FR02 Page43of62 BLE_2M-Ant1-2440-1000~26500-PASS BLE_2M-Ant1-2480-0~Reference-PASS ReportNo.:AGC10211260314FR02 Page44of62 BLE_2M-Ant1-2480-30~1000-PASS BLE_2M-Ant1-2480-1000~26500-PASS ReportNo.:AGC10211260314FR02 Page45of62 TestGraphsofBandEdgeEmissionsinNon-RestrictedFrequencyBands BLE_1M-Ant1-2402-PASS BLE_1M-Ant1-2480-PASS ReportNo.:AGC10211260314FR02 Page46of62 BLE_2M-Ant1-2402-PASS BLE_2M-Ant1-2480-PASS ReportNo.:AGC10211260314FR02 Page47of62 11.RadiatedSpuriousEmission 11.1MeasurementLimit FCCPart15.209Limitinthebelowtabletobefollowed Frequencies (MHz) FieldStrength (microvolts/meter) MeasurementDistance (meters) 0.009~0.4902400/F(kHz)300 0.490~1.70524000/F(kHz)30 1.705~30.03030 30~881003 88~2161503 216~9602003 Above9605003 Note:Allmodesweretestedforrestrictedbandradiatedemission,thetestrecordsreportedbelowaretheworst resultcomparedtoothermodes. 11.2MeasurementProcedure 1.TheEUTwasplacedonthetopoftheturntable0.8or1.5meteraboveground.Thephasecenterofthe receivingantennamountedonthetopofaheight-variableantennatowerwasplaced3metersfaraway fromtheturntable. 2.PowerontheEUTandallthesupportingunits.Theturntablewasrotatedby360degreestodeterminethe positionofthehighestradiation. 3.Theheightofthebroadbandreceivingantennawasvariedbetweenonemeterandfourmetersabove groundtofindthemaximumemissionsfieldstrengthofbothhorizontalandverticalpolarization. 4.Foreachsuspectedemission,theantennatowerwasscan(from1Mto4M)andthentheturntablewas rotated(from0degreeto360degrees)tofindthemaximumreading. 5.Setthetest-receiversystemtoPeakorCISPRquasi-peakDetectFunctionwithspecifiedbandwidthunder MaximumHoldMode. 6.Foremissionsabove1GHz,insertthe2.4GfilterbetweenthereceivingantennaandthePre-amplifier(only forRadiatedSpuriousEmission).Use1MHzRBWand3MHzVBWforpeakreading.Placethe measurementantennaawayfromeachareaoftheEUTdeterminedtobeasourceofemissionsatthe specifiedmeasurementdistance,whilekeepingthemeasurementantennaaimedatthesourceof emissionsateachfrequencyofsignificantemissions,withpolarizationorientedformaximumresponse. ThemeasurementantennamayhavetobehigherorlowerthantheEUT,dependingontheradiation patternoftheemissionandstayingaimedattheemissionsourceforreceivingthemaximumsignal.The finalmeasurementantennaelevationshallbethatwhichmaximizestheemissions.Themeasurement antennaelevationformaximumemissionsshallberestrictedtoarangeofheightsoffrom1mto4m abovethegroundorreferencegroundplane. 7.Whentheradiatedemissionslimitsareexpressedintermsoftheaveragevalueoftheemissions,and pulsedoperationisemployed,themeasurementfieldstrengthshallbedeterminedbyaveragingoverone completepulsetrain,includingblankingintervals,aslongasthepulsetraindoesnotexceed0.1seconds. ReportNo.:AGC10211260314FR02 Page48of62 8.Asanalternative(providedthetransmitteroperatesforlongerthan0.1seconds)orincaseswherethe pulsetrainexceeds0.1seconds,themeasuredfieldstrengthshallbedeterminedfromtheaverage absolutevoltageduringa0.1secondintervalduringwhichthefieldstrengthisatitsmaximumvalues. 9.IftheemissionsleveloftheEUTinpeakmodewas3dBlowerthantheaveragelimitspecified,then testingwillbestoppedandpeakvaluesofEUTwillbereported,otherwise,theemissionswhichdonot have3dBmarginwillberepeatedonebyoneusingthequasi-peakmethodforbelow1GHz. 10.Fortestingabove1GHz,theemissionsleveloftheEUTinpeakmodewaslowerthanaveragelimit(that meanstheemissionslevelinpeakmodealsocomplieswiththelimitinaveragemode),thentestingwillbe stoppedandpeakvaluesofEUTwillbereported,otherwise,theemissionswillbemeasuredinaverage modeagainandreported. 11.Incasetheemissionislowerthan30MHz,loopantennahastobeusedformeasurementandtherecorded datashouldbeQPmeasuredbyreceiver.High-Lowscanisnotrequiredinthiscase. Thefollowingtableisthesettingofspectrumanalyzerandreceiver. SpectrumParameterSetting Start~StopFrequency9kHz~150kHz/RB200HzforQP Start~StopFrequency150kHz~30MHz/RB9kHzforQP Start~StopFrequency30MHz~1000MHz/RB120kHzforQP Start~StopFrequency 1GHz~26.5GHz 1MHz/3MHzforPeak,1MHz/3MHzforAverage ReceiverParameterSetting Start~StopFrequency9kHz~150kHz/RB200HzforQP Start~StopFrequency150kHz~30MHz/RB9kHzforQP Start~StopFrequency30MHz~1000MHz/RB120kHzforQP ReportNo.:AGC10211260314FR02 Page49of62 Quasi-PeakMeasurementsbelow1GHz 1.Analyzercenterfrequencywassettothefrequencyoftheradiatedspuriousemissionofinterest 2.Spanwassetgreaterthan1MHz 3.RBW=asshowninthetableabove 4.Detector=CISPRquasi-peak 5.Sweeptime=autocouple 6.Tracewasallowedtostabilize PeakMeasurementsabove1GHz 1.Analyzercenterfrequencywassettothefrequencyoftheradiatedspuriousemissionofinterest 2.RBW=1MHz 3.VBW=3MHz 4.Detector=peak 5.Sweeptime=autocouple 6.Tracemode=maxhold 7.Tracewasallowedtostabilize AverageMeasurementsabove1GHz 1.Analyzercenterfrequencywassettothefrequencyoftheradiatedspuriousemissionofinterest 2.RBW=1MHz 3.VBW≥[3×RBW] 4.Detector=Poweraveraging(rms) 5.Averagingtype=power(i.e.,rms) 6.Sweeptime=auto 7.Performatraceaverageofatleast100traces. 8.Theapplicablecorrectionfactoris[10*log(1/D)],whereDisthedutycycle.Thefactorhadbeeneditedin the“InputCorrection”oftheSpectrumAnalyzer. ReportNo.:AGC10211260314FR02 Page50of62 11.3MeasurementSetup(BlockDiagramofConfiguration) RadiatedEmissionTestSetup9kHz-30MHz RadiatedEmissionTestSetup30MHz-1000MHz RadiatedEmissionTestSetupAbove1000MHz ReportNo.:AGC10211260314FR02 Page51of62 11.4MeasurementResult RadiatedEmissionBelow30MHz Theamplitudeofspuriousemis…
Text truncated - open the document above for the full version.
ReportNo.:AGC10211260314AP01 Page 1 of 2 TESTSETUPPHOTOS RADIATEDEMISSIONTESTSETUPBELOW1GHz RADIATEDEMISSIONTESTSETUPABOVE1GHz ReportNo.:AGC10211260314AP01 Page 2 of 2 ACCONDUCTEDEMISSIONTESTSETUP ****************************************EndofReport*************************************
5855 SOVEREIGN DRSTE B-1 · HOUSTON, Texas, 77036 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.40 mW |

LED light
Equipment Class
DTS - Digital Transmission System
LED Retrofit Downlight
Equipment Class
DTS - Digital Transmission SystemLED Camera Motion Security Lights
Equipment Class
NII - Unlicensed National Information Infrastructure TX
LED Camera Motion Security Lights
Equipment Class
DTS - Digital Transmission System
Smart LED Downlight
Equipment Class
DTS - Digital Transmission System