FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. WOW Tech Canada Ltd./
  3. ZUE18000

ZUE18000Wand by We-Vibe

WOW Tech Canada Ltd.
Wand by We-Vibe - FCC ID ZUE18000 - WOW Tech Canada Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 16, 2020
Application Purpose
Original Equipment
Date of Application
Mar 16, 2020
Equipment Note
Wand by We-Vibe
Frequency Range
2402.00000000 - 2480.00000000
Company
WOW Tech Canada Ltd.
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Warning: Changes or modifications to this unit not e xpressly approved by theparty responsible for compliance could void the user’s authority to o perate theequipment. NOTE: This equipment has been tested and found to c omply with the limits fora Class B digital device, pursuant to Part 15 of the FCC Rules. These limits aredesigned to provide reasonable protection agains t harmful interference in aresidential installation. This equipment generates , uses and can radiate radiofrequency energy and, if not installed and use d in accordance with theinstructions, may cause harmful interference to radio communications. However, there is no guarantee that interference wi ll not occur in a particularinstallation. If this equipment does caus e harmful interference to radio ortelevision reception, which can be determin ed by turning the by one or more of thefollowing measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and r eceiver. the receiver is connected. Consult the dealer or an experienced radio/TV techn ician for help The device must not be co-located or operating in c onjunction with any other antenna or transmitter. This device complies with Industry Canada license-e xempt RSS standard(s). Operation is subject to the following two condition s: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le pr ésent appareil est conforme aux CNR d’Industrie Can ada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :(1) l’appareil ne doit pas pr oduire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brou illage radioélectrique subi, même si le brouillage est susceptible d’en comprome ttre le fonctionnement. The device is compliance with RF field strength limi ts, users can obtain Canadian information on RF exposure and compliance.Le présent appareil est conforme de ce matériel aux conformités ou aux limites d’intensité de champ RF, les utilisateurs p euvent sur l’exposition aux radiofréquences et la conformité d’acquérir les inf ormations correspondante. This Class B digital apparatus complies with Canadi an ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.CAN ICES-3 (B)/NMB-3(B) FCC ID: ZUE18000This device complies with Part 15 of the FCC Rules, Operation is subject t o the following two conditions: (1) this device may n ot cause harmful interference, and (2) this device must accept any i nterference received, including interference that may cause undesired ope ration. If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its ser vice agent. The appliance has a heated surface. Persons insensi tive to heat must be careful when using the appliance.This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental ca pabilities or lack of experience and knowledge if they have been given su pervision or instruction concerning use of the appliance in a safe way and u nderstand the hazards involved. Children shall not play with the applianc e. Cleaning and user maintenance shall not be made by children without s upervision.

Cover Letter(s)

SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 6.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (obsolete) 2.0 3.0 Jan-31-2012 Updated letter information (obsolete) 3.0 4.0 May-23-2014 Added FCC ID field (obsolete) 4.0 5.0 Sep-16-2014 Updated company name & logo (current) 5.0 6.0 Jun-27-2018 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 6.0 WOW Tech Canada Ltd. 2020.3.11 To: BVCPS, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Product Certification Representative Authorization Letter We, _____ WOW Tech Canada Ltd. __ hereby authorize Bureau Veritas Consumer Product Services, Inc. to act as a Certification Body for certifying for the following project(s): FCC ID: ZUE18000 Product Description: Wand by We-Vibe Model: 18000 Sincerely, Client’s signature Client’s name: Eyal Bar-or Title : Quality Engineer Contact information / address 330-1130 Morrison Drive, Ottawa ON Canada K2H 9N6

Cover Letter(s)

SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 6.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (obsolete) 2.0 3.0 Jan-31-2012 Added IC confidentiality letter form (obsolete) 3.0 4.0 March-26-2015 Corrections to STC form. Added reference to KDB (obsolete) 4.0 5.0 Nov-19-2015 Updated company logo (current) 5.0 6.0 Jun-26-2019 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 6.0 WOW Tech Canada Ltd. 2020.3.12 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: ZUE18000 Pursuant to sections 0.457 and 0.459 of CFR 47, we respectfully request permanent confidential treatment of the following Exhibits accompanying this application as: - Block Diagram - Schematics - Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s signature Client’s name: Eyal Bar-or Title : Quality Engineer Contact information / address 330-1130 Morrison Drive, Ottawa ON Canada K2H 9N6

External Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 3 Report Version 1 Reference No.: 191212N029 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 3 Report Version 1 Reference No.: 191212N029 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 3 Report Version 1 Reference No.: 191212N029

ID Label/Location Info

The label stamped to the equipment by permanent adhesive.

Internal Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 6 Report Version 1 Reference No.: 191212N029 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 6 Report Version 1 Reference No.: 191212N029 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 6 Report Version 1 Reference No.: 191212N029 RF ANT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 6 Report Version 1 Reference No.: 191212N029 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 6 Report Version 1 Reference No.: 191212N029 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 6 of 6 Report Version 1 Reference No.: 191212N029

RF Exposure Info

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 6 Report Version 1 Test Report No.: FM191212N029 RF EXPOSURE REPORT Applicant WOW Tech Canada Ltd. Address 330-1130 Morrison Drive, Ottawa ON Canada K2H 9N6 Manufacturer or Supplier Zhuhai WINGPOW Erotic & Novelty manufacturing CO. LTD Address No. 35 first road, Zhuhai Baijiao New Technology & Industrial Park, Zhuhai, Guangdong China Product Wand by We-Vibe Brand Name We Vibe Model 18000 Additional Model & Model Difference N/A Date of tests Dec. 12, 2019 ~ Jan. 07, 2020 FCC Part 2 (Section 2.1093) KDB 447498 D01 IEEE C95.1 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Breeze Jiang Senior Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Mar. 09, 2020 This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 6 Report Version 1 Test Report No.: FM191212N029 TABLE OF CONTENTS RELEASE CONTROL RECORD ................................................................................ 3 1. CERTIFICATION .............................................................................................. 4 2. RF EXPOSURE DEFINE ................................................................................. 5 3. CLASSIFICATION ........................................................................................... 5 4. SAR TEST EXCLUSION THRESHOLDS ........................................................ 6 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 6 Report Version 1 Test Report No.: FM191212N029 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED FM191212N029 Original release Mar. 09, 2020 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 6 Report Version 1 Test Report No.: FM191212N029 1. CERTIFICATION FCC ID: ZUE18000 PRODUCT: Wand by We-Vibe BRAND NAME: We Vibe MODEL NO.: 18000 ADDITIONAL NO.: N/A TEST SAMPLE: Engineering Sample APPLICANT: WOW Tech Canada Ltd. STANDARDS: FCC Part 2 (Section 2.1093) KDB 447498 D01 IEEE C95.1 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 6 Report Version 1 Test Report No.: FM191212N029 2. RF EXPOSURE DEFINE The corresponding SAR Exclusion Threshold condition, listed below: 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[ √f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,16 where  ï‚· f(GHz) is the RF channel transmit frequency in GHz  ï‚· Power and distance are rounded to the nearest mW and mm before calculation  ï‚· The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. 2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is determined according to the following: a) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)] mW, at 100MHz to 1500 MHz b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤ 6 GHz 3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion. a) The threshold at the correspondin…

Text truncated - open the document above for the full version.

Test Report

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 34 Report Version 1 Test Report No.: RF191212N029 TEST REPORT Applicant WOW Tech Canada Ltd. Address 330-1130 Morrison Drive, Ottawa ON Canada K2H 9N6 Manufacturer or Supplier Zhuhai WINGPOW Erotic & Novelty manufacturing CO. LTD Address No. 35 first road, Zhuhai Baijiao New Technology & Industrial Park, Zhuhai, Guangdong China Product Wand by We-Vibe Brand Name We Vibe Model 18000 Additional Model & Model Difference N/A Date of tests Dec. 12, 2019 ~ Jan. 07, 2020 the tests have been carried out according to the requirements of the following standard: FCC Part 15, Subpart C, Section 15.247 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Breeze Jiang Senior Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Mar. 09, 2020 This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 34 Report Version 1 Test Report No.: RF191212N029 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................ 4 1 SUMMARY OF TEST RESULTS .................................................................................................... 5 2 MEASUREMENT UNCERTAINTY ................................................................................................. 5 3 GENERAL INFORMATION ............................................................................................................ 6 3.1 GENERAL DESCRIPTION OF EUT ............................................................................................. 6 3.2 DESCRIPTION OF TEST MODES ............................................................................................... 7 3.2.1. CONFIGURATION OF SYSTEM UNDER TEST ............................................................... 7 3.2.2. TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL .................................... 7 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................................ 10 3.4 DESCRIPTION OF SUPPORT UNITS ....................................................................................... 10 4 TEST TYPES AND RESULTS .......................................................................................................11 4.1 RADIATED EMISSION MEASUREMENT ................................................................................... 11 4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT ..................................................... 11 4.1.2 TEST INSTRUMENTS ..................................................................................................... 12 4.1.3 TEST PROCEDURES ..................................................................................................... 13 4.1.4 DEVIATION FROM TEST STANDARD ........................................................................... 14 4.1.5 TEST SETUP ................................................................................................................... 14 4.1.6 EUT OPERATING CONDITIONS .................................................................................... 15 4.1.7 TEST RESULTS .............................................................................................................. 16 4.2 6dB BANDWIDTH MEASUREMENT .......................................................................................... 21 4.2.1 LIMITS OF 6dB BANDWIDTH MEASUREMENT ............................................................ 21 4.2.2 TEST INSTRUMENTS ..................................................................................................... 21 4.2.3 TEST PROCEDURE ........................................................................................................ 22 4.2.4 DEVIATION FROM TEST STANDARD ........................................................................... 22 4.2.5 TEST SETUP ................................................................................................................... 23 4.2.6 EUT OPERATING CONDITIONS ........................…

Text truncated - open the document above for the full version.

Test Setup Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 2 Report Version 1 Reference No.: 191212N029 SET-UP FOR RADIATED EMISSION TEST Frequency Range< 30MHz~1GHz > Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 2 Report Version 1 Reference No.: 191212N029 Frequency Range< Above 1GHz >

Contact Information

Applicant

Eyal Bar-Or(Quality Engineer)
[email protected]004930959993814Fax: 613-828-0168

Test Firm

Bureau Veritas Shenzhen Co., Ltd. Dongguan BranchEdwin Ye
[email protected]86-20-8714 8549

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz605.00 µW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power.

Other Applications from WOW Tech Canada Ltd.

ZUEAND2A

Thruster

Mar 10, 2026

Equipment Class

DTS - Digital Transmission System
ZUEMND2A

Orbit

Mar 02, 2026

Equipment Class

DTS - Digital Transmission System
ZUEPRK2A

Prostate Massager

Oct 07, 2024

Equipment Class

DTS - Digital Transmission System
ZUERWVG3B

5 button universal remote

Sep 09, 2024

Equipment Class

DTS - Digital Transmission System
Wearable Vibrator - FCC ID ZUEJIV2B - WOW Tech Canada Ltd.
ZUEJIV2B

Wearable Vibrator

Oct 30, 2023

Equipment Class

DTS - Digital Transmission System