
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Important Product Information Guide This Important Product Information Guide contains safety, handling, regulatory, and software license information, as well as the one-year limited warranty for nabi. Important Safety and Handling Information WARNING: Failure to follow these safety instructions could result in fire, electric shock, or other injury or damage to nabi or other property. Carrying and Handling nabi. nabi contains sensitive components. Do not drop, disassemble, open, crush, bend, deform, puncture, shred, microwave, incinerate, paint, or insert foreign objects into nabi. Avoiding Water and Wet Locations. Do not use nabi in rain or other wet locations. Take care not to spill any food or liquid on nabi. In case nabi gets wet, unplug all cables, turn off nabi (press and hold the Power button, and then select OK in the Power Off window) before cleaning, and allow it to dry thoroughly before turning it on again. Do not attempt to dry nabi with an external heat source, such as a microwave oven or hair dryer. A nabi that has been damaged as a result of exposure to liquids is not serviceable and not covered under warranty. Repairing or Modifying nabi. Never attempt to repair or modify nabi yourself. Disassembling nabi may cause damage that is not covered under the warranty. nabi does not contain any user-serviceable parts. Service should only be provided by a Fuhu Authorized Service Provider. If nabi has been in contact with liquids, punctured, or subjected to a severe fall, do not use it until you take it to a Fuhu Authorized Service Provider. For service information, please visit: www.nabitablet.com/support. Battery Replacement. The rechargeable battery in nabi should be replaced only by Fuhu. For more information about battery replacement service, please visit: www.nabitablet.com/support. Charging nabi. To charge nabi, only use the nabi Power Adapter. The nabi Power Adapter may become warm during normal use. Always allow adequate ventilation around the nabi Power Adapter. Do not connect or disconnect the nabi Power Adapter with wet hands. Unplug the nabi Power Adapter if any of the following conditions exist: • The power cord or plug has become frayed or damaged. • The adapter is exposed to rain, liquid, or excessive moisture. • The adapter case has become damaged. • You suspect the adapter needs service or repair. • You want to clean the adapter. Read all safety instructions for any products and accessories before using with nabi. Fuhu is not responsible for the operation of third-party accessories or their compliance with safety and regulatory standards. Avoiding Hearing Damage. Permanent hearing loss may occur if headphones are used at high volume. Set the volume to a safe level. You can adapt over time to a higher volume of sound that may sound normal but can be damaging to your hearing. If you experience ringing in your ears or muffled speech, stop listening and have your hearing checked. The louder the volume, the less time is required before your hearing could be affected. Hearing experts suggest that to protect your hearing: • Limit the amount of time you use earbuds, headphones, speakers, or earpieces at high volume. • Avoid turning up the volume to block out noisy surroundings. • Turn the volume down if you can’t hear people speaking near you. Driving and Riding Safely. Use of nabi alone or with headphones (even if used only in one ear) while driving a vehicle or riding a bicycle is not recommended and is illegal in some areas. Check and obey the laws and regulations on the use of mobile devices like nabi in the areas where you drive or ride. Be careful and attentive while driving or riding a bicycle. If you decide to use nabi while driving, keep in mind the following guidelines: • Give full attention to driving or riding and to the road. Using a mobile device while driving or riding may be distracting. If you find it disruptive or distracting while operating any type of vehicle, riding a bicycle, or performing any activity that requires your full attention, safely pull off the road and park if driving conditions allow. • Do not email, take notes, or perform any other activities that require your attention while driving. Composing or reading emails or jotting down a to-do list takes attention away from your primary responsibility, driving safely. Seizures, Blackouts, and Eyestrain. A small percentage of people may be susceptible to blackouts or seizures (even if they have never had one before) when exposed to flashing lights or light patterns such as when playing games or watching video. If you have experienced seizures or blackouts or have a family history of such occurrences, you should consult a physician before playing games or watching videos on your nabi. Discontinue use of nabi and consult a physician if you experience headaches, blackouts, seizures, convulsion, eye or muscle twitching, loss of awareness, involuntary movement, or disorientation. To reduce risk of headaches, blackouts, seizures, and eyestrain, avoid prolonged use, hold nabi some distance from your eyes, use nabi in a well-lit room, and take frequent breaks. Glass Parts. The outside cover of the nabi screen is made of glass. This glass could break if nabi is dropped on a hard surface or receives a substantial impact. If the glass chips or cracks, do not touch or attempt to remove the broken glass and stop using nabi. Glass cracked due to misuse or abuse is not covered under the warranty. Choking Hazards. nabi contains small parts, which may present a choking hazard to small children. Keep nabi and its accessories away from small children. Repetitive Motion. When you perform repetitive activities such as typing or playing games on nabi, you may experience occasional discomfort in your hands, arms, shoulders, neck, or other parts of your body. Take frequent breaks and if you have discomfort during or after such use, stop use and see a physician. Potentially Explosive Atmospheres. Turn off nabi (press an…
Text truncated - open the document above for the full version.
KEEN HIGH HOLDING (HK) LIMITED May 4, 2011 To whom it may concern, Request for Permanent Confidentiality Under FCC Part 15 Certification FCC ID: ZYQ-NABI2-NV7A Request is hereby submitted by KEEN HIGH HOLDING (HK) LIMITED to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR § 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential and KEEN HIGH HOLDING (HK) LIMITED reserves the right to discern which parties can obtain access to these information: Schematics Detailed Block diagrams Detailed Operational/Functional Description The rationale for request for confidentiality is as followings: This information represents intellectual property of KEEN HIGH HOLDING (HK) LIMITED and it is subject to competition. We have invested considerable time and materials in research and development to produce the referenced product. Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us. If you have questions or need further information, please contact the undersigned. Regards, Michael.chang / Marketing & Technology Director KEEN HIGH HOLDING (HK) LIMITED
External Photos Front Back
Label Artwork and Location
Internal Photos
SZ12050092S01 Page 2 of 65 DIRECTORY TESTING LABORATORY.............................................................................................................4 1.1. Identification of the Responsible Testing Laboratory................................................................. 4 1.2. Identification of the Responsible Testing Location.....................................................................4 1.3. Accreditation Certificate..............................................................................................................4 1.4. List of Test Equipments...............................................................................................................4 2. TECHNICAL INFORMATION..................................................................................................5 2.1. Identification of Applicant...........................................................................................................5 2.2. Identification of Manufacturer.....................................................................................................5 2.3. Equipment Under Test (EUT)......................................................................................................5 2.3.1. Photographs of the EUT............................................................................................................5 2.3.2. Identification of all used EUT...................................................................................................5 2.4. Applied Reference Documents.................................................................................................... 6 2.5. Device Category and SAR Limits................................................................................................6 2.6. Test Environment/Conditions......................................................................................................7 3. SPECIFIC ABSORPTION RATE (SAR)...................................................................................8 3.1. Introduction..................................................................................................................................8 3.2. SAR Definition............................................................................................................................ 8 4. SAR MEASUREMENT SETUP..................................................................................................9 4.1. The Measurement System............................................................................................................9 4.2. Probe............................................................................................................................................ 9 4.3. Probe Calibration Process..........................................................................................................11 4.3.1 Dosimetric Assessment Procedure...........................................................................................11 4.3.2 Free Space Assessment Procedure...........................................................................................11 4.3.2 Temperature Assessment Procedure........................................................................................11 4.4. Phantom..................................................................................................................................... 12 4.5. Device Holder............................................................................................................................12 5. TISSUE SIMULATING LIQUIDS........................................................................................... 13 6. UNCERTAINTY ASSESSMENT............................................................................................. 14 6.1. UNCERTAINTY EVALUATION FOR HANDSET SAR TEST............................................ 14 6.2. UNCERTAINTY FOR SYSTEM PERFORMANCE CHECK................................................ 15 7. SAR MEASUREMENT EVALUATION................................................................................. 17 SZ12050092S01 Page 3 of 65 7.1. System Setup..............................................................................................................................17 7.2. Validation Results......................................................................................................................18 8. OPERATIONAL CONDITIONS DURING TEST..................................................................19 8.1. Body-worn Configurations........................................................................................................ 19 8.2. Measurement procedure.............................................................................................................19 8.3. Description of interpolation/extrapolation scheme....................................................................20 8.4. Measurement Of Conducted Peak Output Power......................................................................21 9. TEST RESULTS LIST...............................................................................................................22 ANNEX A EUT SETUP PHOTOS................................................................................................23 ANNEX B GRAPH TEST RESULTS...........................................................................................27 Change History IssueDateReason for change 1.0May 20 ,2012First edition 2.0May 24 ,2012Add the distance of antenna to edges. SZ12050092S01 Page 4 of 65 Testing Laboratory 1.1. Identification of the Responsible Testing Laboratory Company Name:Shenzhen Morlab Communications Technology Co., Ltd. Department:Morlab Laboratory Address:3/F, Electronic Testing Building, Shahe Road, Nanshan District, Shenzhen, 518055 P. R. China Responsible Test Lab Manager:Mr. Shu Luan Telephone:+86 755 86130268 Facsimile:+86 755 86130218 1.2. Identification of the Responsible …
Text truncated - open the document above for the full version.
Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report 1 COMOSAR E-FIELD PROBE CALIBRATION REPORT Prepared By: LUC Jérôme, SATIMO Project Description: SAR TEST BENCH Prepared For (End User): Shenzhen Morlab Communication Technology This document is issued by SATIMO, in confidence and is not to be reproduced in whole or in part without the prior written permission. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or in part without the prior written permission of SATIMO. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report 2 COMOSAR SEPT ISOTROPIC E-FIELD PROBE CALIBRATION REPORT DATE: 12/02/2009 REFERENCE: SN 37/08 EP80 OBJECT: COMOSAR SEPT ISOTROPIC E-FIELD PROBE MANUFACTURER: SATIMO SERIAL NUMBER: SN 37/08 EP80 CUSTOMER: Shenzhen Morlab Communication Technology CONTRACT: PF2130108b_SAR_Morlab DATE OF CALIBRATION: 24/09/20 WARRANTY: This Calibration certificate may not be reproduced other than in full. Calibration certificates without signature and seal are not valid. This documentation contains property information which is protected by copyright. All right are reserved. No part of this document may be photocopied, reproduced without the prior written agreement of SATIMO. SATIMO shall not be liable for errors contained herein or for incidental or consequential in connection with the furnishing, performance or use of this material. Warranty doesn’t apply to Normal wear, Normal tear, Improper use, Improper maintain, Improper installation. Date SAR TEAM MANAGER Date SAR TEAM MANAGER Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report 3 PRODUCT DESCRIPTION Frequency Range 100 MHz - 30 GHz Probe length 330 mm Length of one dipole 4.5 mm Maximum external diameter 8 mm Probe extremity diameter 6.5 mm Distance between dipoles/probe extremity < 2.7 mm Resistance of the three dipole (at the connector) Dipole 1: R1=1.4382 MΩ Dipole 2: R2=1.4894 MΩ Dipole 3: R3=1.4683 MΩ Connector (HIROSE series SR30) 6 wire male (Hirose SR30series) The probe could be checked by measuring the resistance of the three dipoles. CALIBRATION TEST EQUIPMENT TYPE IDENTIFICATION Calibration bench CALISAR Multimeter Keithley 2000 Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report 4 MEASUREMENT PROCEDURE Probe calibration is realized, in compliance with CENELEC EN 50361 and IEEE 1528 std, with CALISAR, Antennessa proprietary calibration system. The calibration is performed with the EN 50361 annexe technique using reference guide at the five frequencies. Where : P fw = Forward Power P bw = Backward Power a and b = Waveguide dimensions = Skin depth Keithley configuration: Rate = Medium; Filter =ON; RDGS=10; FILTER TYPE =MOVING AVERAGE; RANGE AUTO After each calibration, a SAR measurement is performed on a validation dipole and compared with a NPL calibrated probe, to verify it. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report 5 PROBE UNCERTAINTIES Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report 6 1. Calibration at 450.00 MHz A. Calibration parameters. Label GSM450 Epsilon 43.33 Sigma 0.84 S/m Temperature 21°C Antenna gain 2.03 dB Antenna S11 -10.50 dB Low limit detection (CW) Calibration curves ei=f(V) (i=1,2,3) allow to obtain E-field value using the formula: EEEE= The following tables represent the calibration curves linearization by curve segment in CW signal. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report 7 Calibration coefficients for the three dipoles in CW: v1 e1 v2 e2 v3 e3 0.584004 419.557857 -0.696059 435.622023 0.541191 412.830715 0.467833 339.207465 -0.556278 351.381991 0.469757 336.297240 0.376994 276.348283 -0.452232 288.647980 0.378826 274.224190 0.302778 224.954643 -0.359005 232.397390 0.305842 224.365698 0.241038 182.154071 -0.286978 188.889931 0.246562 183.825274 0.192549 148.484090 -0.230386 154.650994 0.195712 148.993075 0.154033 121.674762 -0.185412 127.378480 0.157543 122.783107 0.123397 100.276479 -0.147311 104.193802 0.125866 100.956090 0.099878 83.770361 -0.118637 86.660489 0.101471 84.063863 0.081165 70.553219 -0.095250 72.263937 0.082289 70.694342 0.065166 59.152028 -0.076788 60.795323 0.066427 59.538957 0.051916 49.592416 -0.061280 51.041514 0.053353 50.232492 0.041968 42.297602 -0.048746 43.022565 0.042906 42.675214 0.033724 36.126757 -0.039149 36.748110 0.034686 36.605243 0.021855 26.962568 -0.024798 27.024723 0.022272 27.149463 0.018405 23.975145 -0.020856 24.085809 0.018755 24.141334 0.015467 21.515985 -0.017534 21.515985 0.015767 21.615299 0.013018 19.309065 -0.014750 19.398191 0.013276 19.487731 0.010938 17.408496 -0.012392 17.529166 0.011157 17.569575 0.009022 15.586953 -0.010228 15.658899 0.009215 15.676938 0.007353 13.956010 -0.008328 13.988181 0.007484 14.020428 0.005989 12.466979 -0.006801 12.495719 0.006111 12.567858 0.004890 11.214019 -0.005573 11.265779 0.005003 11.330818 0.004019 10.133541 -0.004570 10.121882 0.004099 10.168601 0.003279 9.094132 -0.003739 9.157170 0.003352 9.125596 0.002660 8.095827 -0.003041 8.293946 0.002769 8.265350 0.002126 7.324219 -0.002453 7.366500 0.002188 7.358024 0.001685 6.565400 -0.001947 6.580536 0.001724 6.542765 0.001300 5.784440 -0.001511 5.718225 0.001334 5.757862 0.001123 5.245191 -0.001307 5.269400 0.001174 5.275471 0.000891 4.701768 -0.001057 4.723470 0.000924 4.728912 0.000704 4.209798 -0.000850 4.226839 0.000736 4.243862 0.000574 3.790376 -0.000689 3.791428 0.000603 3.830551 0.000457 3.396200 -0.000570 3.434303 0.000483 3.421852 0.000365 3.050686 -0.000463 3.078014 0.000389 3.079630 0.000292 2.745766 -0.000369 2.726866 0.00031…
Text truncated - open the document above for the full version.
COMOSAR Dipole 2450 MHz Calibration Report Ref: CR-280-7-08-SATB-A Page: 1/8Issue: BDate: 2011/9/23 DIPOLE 2450 MHZ CALIBRATION REPORT Prepared By:LUC Jérôme, SATIMO Project Description:SAR TEST BENCH Prepared For (End User):Shenzhen Morlab Communication Technology This document is issued by SATIMO, in confidence and is not to be reproduced in whole or in part without the prior written permission. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or in part without the prior written permission of SATIMO. COMOSAR Dipole 2450 MHz Calibration Report Ref: CR-280-7-08-SATB-A Page: 2/8Issue: BDate: 2011/9/23 DIPOLE 2450 MHz CALIBRATION REPORT DATE: 19/02/2009 REFERENCE: SN 36/08 DIPJ103 OBJECT: COMOSAR IEEE REFERENCE DIPOLE MANUFACTURER:SATIMO SERIAL NUMBER: SN 36/08 DIPJ103 CUSTOMER: Shenzhen Morlab Communication Technology CONTRACT: PF2130108b_SAR_Morlab DATE OF CALIBRATION: 23/09/2011 WARRANTY: This Calibration certificate may not be reproduced other than in full. Calibration certificates without signature and seal are not valid. This documentation contains property information which is protected by copyright. All right are reserved. No part of this document may be photocopied, reproduced without the prior written agreement of SATIMO. SATIMO shall not be liable for errors contained herein or for incidental or consequential in connection with the furnishing, performance or use of this material. Warranty doesn’t apply to Normal wear, Normal tear, Improper use, Improper maintain, Improper installation. COMOSAR Dipole 2450 MHz Calibration Report Ref: CR-280-7-08-SATB-A Page: 3/8Issue: BDate: 2011/9/23 PRODUCT DESCRIPTION Dimension: L=161 mm/ h=89.8mm / d=3.6 mm CALIBRATION TEST EQUIPMENT TYPEIDENTIFICATIONDATE OF CALIBRATIO Vector Network Analyzer HP8753D (SN: 5410A08882)10-05-2011 MEASUREMENT PROCEDURE We placed the dipole under the flat part of SAM phantom fill with 2450 MHz head and body liquid. COMOSAR Dipole 2450 MHz Calibration Report Ref: CR-280-7-08-SATB-A Page: 4/8Issue: BDate: 2011/9/23 Calibration was performed according to IEEE Std P1528-2003 and OET bulletin 65 Supplement C (Ed. 01-01) VSWRat2450MHz:-33.09dB. COMOSAR Dipole 2450 MHz Calibration Report Ref: CR-280-7-08-SATB-A Page: 5/8Issue: BDate: 2011/9/23 SAR MEASUREMENT EQUIPEMENT Head VoltmeterKeithley (2000, SN:1000572)Date of calibration: 01-07-2011 Signal generatorRohde&Schwarz (SML_03, SN:101868) Date of calibration: 15-11-2010 Power amplifierNuclétudes (ALB216, SN:10800)Date of calibration: 24-10-2010 Power meterRohde&Schwarz (NRVD, SN:101066)Date of calibration: 04-07-2011 Probe SATIMO Bretagne (SN:EP37) CF (30.41,29.18,32.33) Date of calibration: 19-06-2011 SAR MEASUREMENT CONDITION SoftwareOpenSAR V3 PhantomSATIMO Bretagne (SN: SN_20_07_SAM42) Liquid SATIMO Bretagne (Last Calibration: 18 09 11) Head Liquid Values: eps’ : 39,80 sigma : 1,88 Distance between the center of the dipole and the liquid (set with a spacer) 15 mm Area scan resolutiondx=8mm/dy=8mm Zoom scan resolutiondx=8mm/dy=8m/dz=5mm Frequency2450 MHz Input power30 dBm Expanded uncertainty (K=1) 8.09% SAR MEASUREMENT RESULT 10g1g SAR measured Liquid : HL Input power : 1W 23,61 W/Kg -1,63 % 53,85W/Kg +2,77% COMOSAR Dipole 2450 MHz Calibration Report Ref: CR-280-7-08-SATB-A Page: 6/8Issue: BDate: 2011/9/23 SAR MEASUREMENT PLOTS Head: COMOSAR Dipole 2450 MHz Calibration Report Ref: CR-280-7-08-SATB-A Page: 7/8Issue: BDate: 2011/9/23 SAR MEASUREMENT EQUIPEMENT Body VoltmeterKeithley (2000, SN:1000572)Date of calibration: 01-07-2011 Signal generatorRohde&Schwarz (SML_03, SN:101868) Date of calibration: 15-11-2010 Power amplifierNuclétudes (ALB216, SN:10800)Date of calibration: 24-10-2010 Power meterRohde&Schwarz (NRVD, SN:101066)Date of calibration: 04-07-2011 Probe SATIMO Bretagne (SN:EP37) CF (30.41,29.18,32.33) Date of calibration: 19-06-2011 SAR MEASUREMENT CONDITION SoftwareOpenSAR V3 PhantomSATIMO Bretagne (SN: SN_20_07_SAM42) Liquid SATIMO Bretagne (Last Calibration: 18 09 11) Body Liquid Values: eps’ : 52,50 sigma : 1,78 Distance between the center of the dipole and the liquid (set with a spacer) 15 mm Area scan resolutiondx=8mm/dy=8mm Zoom scan resolutiondx=8mm/dy=8m/dz=5mm Frequency835 MHz Input power30 dBm Expanded uncertainty (K=1) 8.09% SAR MEASUREMENT RESULT 10g1g SAR measured Liquid : HL Input power : 1W 21,45 W/Kg +1,66% 50,82 W/Kg -3,01 % COMOSAR Dipole 2450 MHz Calibration Report Ref: CR-280-7-08-SATB-A Page: 8/8Issue: BDate: 2011/9/23 SAR MEASUREMENT PLOTS Body:
• The test results reported in this test report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample m ay be said to have been obtained. • This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results referenced from this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. • For Terms And Conditions of the services, it can be provided upon request. • The evaluation data of the report will be kept for 3 years from the date of issuance. TRF no.: FCC 15C_Txa F CC ID: ZYQ-NABI2-NV7A I ntertek Testing Services Shenzhen Ltd. Kejiyuan Branch 6F, D Block, Huahan Building, Langshan Road, Nanshan District, Shenzhen, P. R. China Tel: (86 755) 8601 6288 Fax: (86 755) 8601 6751 Website: www.china.intertek-etlsemko.com KEEN HIGH HOLDING(HK) LIMITED Application For Certification Mobile Internet Device (WiFi Transceiver) (FCC ID: ZYQ-NABI2-NV7A) Model: NABI2-NV7A A dditional Model: MT799 Report No.: SZ12050093-1 Prepared and Checked by: Approved by: Billy Li Team Leader May 16, 2012 Shawn Xing Manager Date: 18 May, 2012 INTERTEK TESTING SERVICE TRF no.: FCC 15C_TXa FCC ID: ZYQ-NABI2-NV7A i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1: Summary of Tests EXHIBIT 2: General Description EXHIBIT 3: System Test Configuration EXHIBIT 4: Measurement Results EXHIBIT 5: Equipment Photographs EXHIBIT 6: Product Labeling EXHIBIT 7: Technical Specifications EXHIBIT 8: Instruction Manual EXHIBIT 9: Miscellaneous Information EXHIBIT 10: Test Equipment List INTERTEK TESTING SERVICES TRF No.: FCC 15C_TXa FCC ID: ZYQ-NABI2-NV7A ii MEASUREMENT/TECHNICAL REPORT KEEN HIGH HOLDING(HK) LIMITED - MODEL: NABI2-NV7A Additional Model: MT799 FCC ID: ZYQ-NABI2-NV7A This report concerns (check one) Original Grant X Class II Change Equipment Type: DTS - Part 15 Digital Transmission Systems (WiFi transmitter portion) Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? Yes No X If yes, defer until : date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37? Yes No X If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR [10-01-11 Edition] provision. Report prepared by: Shawn Xing Intertek Testing Services Shenzhen Ltd. Kejiyuan Branch 6F, Block D, Huahan Building, Langshan Road, Nanshan District, Shenzhen, P. R. China Phone: (86 755) 8601 6288 Fax: (86 755) 8601 6751 INTERTEK TESTING SERVICES TRF No.: FCC 15C_TXa FCC ID: ZYQ-NABI2-NV7A iii Table of Contents 1.0 Summary of test results...............................................................................2 2.0 General Description................................................................................................4 2.1 Product Description ....................................................................................... 4 2.2 Related Submittal(s) Grants .......................................................................... 5 2.3 Test Methodology.......................................................................................... 5 2.4 Test Facility ................................................................................................... 5 3.0 System Test Configuration ................................................................................. 7 3.1 Justification ................................................................................................... 7 3.2 EUT Exercising Software............................................................................... 7 3.3 Details of EUT and Description of Peripherals ............................................... 8 3.4 Measurement Uncertainty.............................................................................. 8 3.5 Equipment Modification ................................................................................. 8 3.6 Support Equipment List and Description....................................................... 9 4.0 Measurement Results.......................................................................................... 11 4.1 Maximum Conducted Output Power at Antenna Terminals.......................... 11 4.2 Minimum 6dB RF Bandwidth ....................................................................... 16 4.3 Maximum Power Density ................................................................................22 4.4 Out of Band Conducted Emissions ...............................................................28 4.5 Out of Band Radiated Emissions ................................................................. 38 4.6 Transmitter Radiated Emissions in Restricted Bands................................... 39 4.7 Field Strength Calculation............................................................................ 40 4.8 Radiated Spurious Emission...........................................................................41 4.9 Conducted Emission .......................................................................................52 4.10 Radiated Emission from Digital Section of Transc…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 115.60 mW |

Tablet
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
TABLET
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Tablet
Equipment Class
DTS - Digital Transmission System
Mobile Internet Device
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Mobile Internet Device
Equipment Class
DTS - Digital Transmission System